IR 05000458/2011002
| ML110380088 | |
| Person / Time | |
|---|---|
| Site: | River Bend |
| Issue date: | 02/07/2011 |
| From: | Thomas Farnholtz Region 4 Engineering Branch 1 |
| To: | Mike Perito Entergy Operations |
| References | |
| IR-11-002 | |
| Download: ML110380088 (6) | |
Text
February 7, 2011
SUBJECT:
RIVER BEND STATION - NRC INTEGRATED INSPECTION REPORT 05000458/2011002
Dear Mr. Perito:
The purpose of this letter is to notify you that the U.S. Nuclear Regulatory Commission (NRC)
Region IV staff will conduct a triennial heat sink inspection at your facility. The inspection will be comprised of one reactor inspector from the NRC Region IV office. The inspection will be conducted in accordance with Inspection Procedure 71111.07T, "Heat Sink Performance."
The schedule for the inspection is as follows: onsite inspection: March 14-18, 2011
Experience has shown that this inspection is resource intensive both for the NRC inspectors and your staff. In order to minimize the impact to your onsite resources and to ensure a productive inspection, we have enclosed a request for documents needed for this inspection.
Please note that the documents are requested to be provided by March 4, 2011. We request, that during the onsite inspection week, you ensure that copies of analyses, evaluations, or documentation regarding the implementation and maintenance of your heat exchanger program are available. Of specific interest are those documents that establish that your heat exchanger program satisfies NRC regulatory requirements and conforms to applicable NRC guidance.
Also, appropriate personnel knowledgeable of safety-related heat exchangers should be available to support the inspector at the site during the inspection.
We have discussed the schedule for this inspection activity with your staff and understand that our regulatory contact for this inspection will be Ms. Kristi Huffstatler of your licensing organization. If there are any questions about this inspection or the material requested, please contact the lead inspector, Ronald A. Kopriva, at 817-860-8104 or by email, ron.kopriva@nrc.gov. In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
UNITED STATES NUCLEAR REGULATORY COMMISSION R E GI ON I V 612 EAST LAMAR BLVD, SUITE 400 ARLINGTON, TEXAS 76011-4125
Entergy Operations, Inc.
- 2 -
Sincerely,
/RA/
Thomas R. Farnholtz, Chief Engineering Branch 1 Division of Reactor Safety
Docket: 50-458 License: NPF-47
Enclosure: Heat Exchanger/Heat Sink Inspection Documentation Request
cc w/enclosure:
Senior Vice President and COO Entergy Operations, Inc P. O. Box 31995 Jackson, MS 39286-1995
Vice President, Oversight Entergy Operations, Inc.
P. O. Box 31995 Jackson, MS 39286-1995
Senior Manager, Nuclear Safety & Licensing Entergy Nuclear Operations P. O. Box 31995 Jackson, MS 39286-1995
Manager, Licensing Entergy Operations, Inc.
5485 US Highway 61N St. Francisville, LA 70775
Attorney General State of Louisiana P. O. Box 94005 Baton Rouge, LA 70804-9005
Ms. H. Anne Plettinger 3456 Villa Rose Drive Baton Rouge, LA 70806
Entergy Operations, Inc.
- 3 -
President of West Feliciana Police Jury P. O. Box 1921 St. Francisville, LA 70775
Mr. Brian Almon Public Utility Commission William B. Travis Building P. O. Box 13326 Austin, TX 78701-3326
Mr. Jim Calloway Public Utility Commission of Texas 1701 N. Congress Avenue Austin, TX 78711-3326
Louisiana Department of Environmental Quality Radiological Emergency Planning and Response Division P. O. Box 4312 Baton Rouge, LA 70821-4312 Joseph A. Aluise Associate General Counsel - Nuclear Entergy Services, Inc.
639 Loyola Avenue New Orleans, LA 70113
Chief, Technological Hazards Branch FEMA Region VI 800 N. Loop 288 Denton, TX 76209-3606
Entergy Operations, Inc.
- 4 -
Electronic distribution by RIV:
Regional Administrator (Elmo.Collins@nrc.gov )
Deputy Regional Administrator (Art.Howell@nrc.gov )
DRP Director (Kriss.Kennedy@nrc.gov )
DRP Deputy Director (Troy.Pruett@nrc.gov )
DRS Director (Anton.Vegel@nrc.gov )
DRS Deputy Director (Vacant)
Senior Resident Inspector (Grant.Larkin@nrc.gov )
Branch Chief, DRP/C (Vincent.Gaddy@nrc.gov )
RBS Administrative Assistant (Lisa.Day@nrc.gov )
Senior Project Engineer, DRP/C (Bob.Hagar@nrc.gov )
Project Engineer, DRP/C (Rayomand.Kumana@nrc.gov )
Public Affairs Officer (Victor.Dricks@nrc.gov)
Public Affairs Officer (Lara.Uselding@nrc.gov )
Project Manager (Alan.Wang@nrc.gov )
Branch Chief, DRS/TSB (Michael.Hay@nrc.gov )
RITS Coordinator (Marisa.Herrera@nrc.gov )
Regional Counsel (Karla.Fuller@nrc.gov )
Congressional Affairs Officer (Jenny.Weil@nrc.gov )
OEMail Resource
Inspection Reports/MidCycle and EOC Letters to the following:
ROPreports
Only inspection reports to the following:
OEDO RIV Coordinator (James.Trapp@nrc.gov )
DRS/TSB STA (Dale.Powers@nrc.gov )
File located:
ML110380088 SUNSI Rev Compl.
X Yes No ADAMS X Yes No Reviewer Initials
Publicly Avail X Yes No Sensitive Yes X No Sens. Type Initials
RIV: DRS/EB1/SRI
C: EB1 R. Kopriva
TFarnholtz
/RA/
/RA/
01/06/11
01/07/11 OFFICIAL RECORD COPY T=Telephone E=E-mail F=Fax
- 1 -
Enclosure ENCLOSURE
Heat Exchanger/Heat Sink Inspection Documentation Request
The following heat exchangers/heat sinks have been selected for inspection:
- Residual Heat Removal Heat Exchanger B, Component ID: E12-EB001B
- Reactor Water Cleanup - Regenetive Heat Exchanger C, Component ID: G33-EB001C
- Residual Heat Removal Room Cooler B, Component ID: HVR-UC9 BLOWER
Please provide the following documentation prior to the onsite inspection week, preferably no later than March 4, 2011.
Test Documents
Copies of the last two heat exchanger tests for the selected heat exchangers (original test data in work orders or filled in test procedures) and copies of condition reports associated with the heat exchanger testing
List of condition reports, with descriptions, associated with heat exchanger testing for the past 3 years (all safety-related heat exchangers)
Copies of applicable heat exchanger test procedures for the selected heat exchangers, including test conditions and acceptance criteria
Copies of chemistry control procedures and results of chemistry sampling and a list of condition reports concerning service water chemistry problems for the past 3 years
Documents that show the as-found results are recorded, evaluated, and appropriately dispositioned such that the as-left condition is acceptable
Cleaning Documents
Copies of the last two heat exchanger cleaning results for the selected heat exchangers, original data (found in filled test procedures or work orders) and condition reports associated with heat exchanger cleaning
Cleaning procedures with acceptance criteria for the selected heat exchangers
List of condition reports, with descriptions, associated with heat exchanger cleaning for the past 3 years (all safety-related heat exchangers)
Show that as-found results are recorded, evaluated, and appropriately dispositioned such that the as-left condition is acceptable
- 2 -
Enclosure Design Documents
Copies of vendor data sheets and design basis data for the selected heat exchangers
The design margin of the heat exchangers (the maximum heat transfer rate achievable at design basis conditions compared to the vendors design heat transfer rate)
Copies of calculations which show the heat exchangers will meet their design basis requirements under worst case conditions. Calculation for the maximum allowable number of tubes plugged and how many tubes are currently plugged
For room coolers, calculations of the maximum room temperature under accident conditions and determination that the coolers can maintain less than the maximum temperature under design conditions
Documents that show that the heat exchangers have been evaluated for potential water hammer
Instrument uncertainties of the instruments used during testing
Corrective action reports concerning cavitation noise in any heat exchanger system
The most recent audit report of heat exchanger testing and cleaning
The most recent service water flow balance test results, both as-found and as-left
Corrective Action Documents
List of corrective action documents, with descriptions, for the past 3 years for all safety-related heat exchangers
Inspector Contact Information:
Ronald A. Kopriva Senior Reactor Inspector 817-860-8104 Ron.kopriva@nrc.gov.
Mailing Address:
US NRC Region IV Attn: Ron Kopriva 612 East Lamar Blvd., Suite 400 Arlington, TX 76011-4125