05000458/FIN-2011002-02
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Failure to Determine the Appropriate Preventive Maintenance Strategy and Task Frequency for the Reactor Core Isolation Cooling System Turbine Lube Oil Cooler Inlet Pressure Control Valve |
| Description | The inspectors reviewed a self-revealing noncited violation of Technical Specification 5.4.1 for the licensees failure to determine the appropriate preventive maintenance strategy and task frequency for the reactor core isolation cooling system turbine lube oil cooler inlet pressure control valve (E51-PCVF015). The vendor manual for the pressure control valve recommends that non-metallic parts (including diaphragms) be replaced after 5 years in service. On October 13, 2010, after being in service for more than ten years without diaphragm replacement, the valve developed a leak that rendered the reactor core isolation cooling system inoperable. The licensee replaced the damaged diaphragm and created a preventive maintenance activity for its periodically replacement. This issue was entered into the licensees corrective action program as Condition Report CR-RBS-2010-05224. This finding was more than minor because it was associated with the equipment performance attribute of the Mitigating Systems Cornerstone and adversely affected the associated cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the subject performance deficiency allowed a failure to occur that rendered the reactor core isolation cooling system inoperable for approximately 14 hours1.62037e-4 days <br />0.00389 hours <br />2.314815e-5 weeks <br />5.327e-6 months <br />. Because this finding occurred while the unit was operating at full power, the inspectors used Inspection Manual Chapter 0609, Attachment 4, Phase 1 - Initial Screening and Characterization of Findings, to assess its risk significance. The reactor core isolation cooling diaphragm failure was determined to have occurred when the pump was secured; that is, the pump could have operated for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> if it had not been shut down at that time. Therefore, the exposure time was equal to the repair time, which was 15.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />. The finding involved a loss of safety system function and therefore did not screen in Phase 1, requiring a Phase 2 evaluation. The inspectors used the Phase 2 pre-solved spreadsheet with a duration of 0-3 days to determine that the issue had very low significance (Green). The inspectors concurred with the licensees determination that a lack of technical rigor had been the reason why the preventive maintenance evaluation of valve E51-PCVF015 had been incorrect, and was therefore the major contributor to the finding. The inspectors considered that this contributor does not reflect current licensee performance because this contributor is a human performance error that occurred in September 2006, and because in 2007, the licensee developed corrective actions to address a substantive crosscutting issue in human performance. Those actions are described in Condition Report CR-RBS-2007-00835 and included activities that changed the licensees human performance program such that the human performance error that occurred in September of 2006 is not likely to re-occur. This finding therefore does not have a crosscutting aspect (Section 1R12). |
| Site: | River Bend |
|---|---|
| Report | IR 05000458/2011002 Section 1R12 |
| Date counted | Mar 31, 2011 (2011Q1) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | Self-revealing |
| Inspection Procedure: | IP 71111.12 |
| Inspectors (proximate) | T Farina L Ricketson P Elkmann B Tharakan R Kopriva D Stearns A Barrett G Larkin V Gaddy D Strickland |
| INPO aspect | |
| ' | |