MONTHYEARML1025906042010-09-16016 September 2010 Acceptance Review E-mail License Amendment Request, Revise License Condition and Approve Cyber Security Plan Project stage: Acceptance Review ML1100300792010-12-30030 December 2010 Response to Request for Additional Information Regarding License Amendment Request LDCN 10-0022 Project stage: Response to RAI ML1106301182011-03-0404 March 2011 Request for Additional Information Related to License Amendment Request to Revise License Condition and Approve Cyber Security Plan Project stage: RAI ULNRC-05778, Response to NRC Request for Additional Information Regarding Request for Approval of Security Plan (License Amendment Request LDCN 10-0022, TAC No. ME45362011-04-0101 April 2011 Response to NRC Request for Additional Information Regarding Request for Approval of Security Plan (License Amendment Request LDCN 10-0022, TAC No. ME4536 Project stage: Response to RAI ML1108309782011-04-14014 April 2011 Request for Additional Information for the Review of the South Texas Project, License Renewal Application, Fire Protection and Component Integrity (TAC Nos. ME4536 ME4637 Project stage: RAI ULNRC-05790, Facility Operating License NPF-30, Cyber Security Plan Supplement (Lcdn 10-0022 Suppl 1)2011-06-14014 June 2011 Facility Operating License NPF-30, Cyber Security Plan Supplement (Lcdn 10-0022 Suppl 1) Project stage: Supplement ULNRC-05805, Supplement to Request for Approval of the Cyber Security Plan2011-06-29029 June 2011 Supplement to Request for Approval of the Cyber Security Plan Project stage: Supplement ML1121400872011-08-17017 August 2011 Issuance of Amendment No. 203, Revise License Condition and Approve Cyber Security Plan and Associated Implementation Schedule Project stage: Approval ULNRC-06208, Request for Approval of a Change to the Security Plan Implementation Date (License Amendment Request LDCN 15-0009)2015-04-29029 April 2015 Request for Approval of a Change to the Security Plan Implementation Date (License Amendment Request LDCN 15-0009) Project stage: Request 2011-04-14
[Table View] |
|
---|
Category:Letter
MONTHYEARULNRC-06853, Submittal of 2023 Fitness for Duty Performance Data Per Per 10 CFR 26.7172024-01-29029 January 2024 Submittal of 2023 Fitness for Duty Performance Data Per Per 10 CFR 26.717 IR 05000483/20230042024-01-19019 January 2024 Integrated Inspection Report 05000483/2023004 ML24008A0552024-01-19019 January 2024 Acceptance of Requested Licensing Action - Proposed Alternative to the Requirements of the ASME Code (EPID L-2023-LLR- 0061) ML23353A1712024-01-18018 January 2024 Issuance of Amendment No. 237 to Clarify Support System Requirements for the Residual Heat Removal System and Control Room Air Conditioning System Under Technical Specifications 3.4.8, 3.7.11, and 3.9.6 ML23317A0012024-01-12012 January 2024 Audit Summary Regarding LAR to Clarify Support System Requirements for the Residual Heat Removal and Control Room Air Conditioning System Under Technical Specifications 3.4.8, 3.7.11, and 3.9.6 ML23347A1212024-01-11011 January 2024 Issuance of Amendment No. 236 to Adopt TSTF-501, Revision 1, Relocate Stored Fuel Oil and Lube Volume Values to Licensee Control EPID L-2023-LLA-0046) ML24011A1492024-01-11011 January 2024 Notification of Post-Approval Site Inspection for License Renewal and Request for Information (05000483/2024011) ULNRC-06847, Supplement to Relief Request from Requirements of ASME BPV Code, Section XI, Subsection Iwl Regarding Examination and Testing of the Unbonded Post-Tensioning System (Relief Request C3R-01)2023-12-21021 December 2023 Supplement to Relief Request from Requirements of ASME BPV Code, Section XI, Subsection Iwl Regarding Examination and Testing of the Unbonded Post-Tensioning System (Relief Request C3R-01) ULNRC-06849, License Renewal Resolution for Commitments 34 and 35 Perform Evaluation of Crack Initiation and Propagation in Steam Generator Divider Plate and Tube-To-Tubesheet Welds2023-12-20020 December 2023 License Renewal Resolution for Commitments 34 and 35 Perform Evaluation of Crack Initiation and Propagation in Steam Generator Divider Plate and Tube-To-Tubesheet Welds ML23346A0392023-12-14014 December 2023 Supplemental Information Needed for Acceptance of Requested Licensing Action Request for Relief from Requirements of ASME Code, Section Xl, Examination and Testing Unbonded Post-Tensioning System ULNRC-06844, Request for Exemption from Specific Requirements in 2023 Security Rule, Enhanced Weapons, Firearms Background Checks, and Security Event Notification2023-12-0707 December 2023 Request for Exemption from Specific Requirements in 2023 Security Rule, Enhanced Weapons, Firearms Background Checks, and Security Event Notification 05000483/LER-2023-001, Submittal of LER 2023-001-00 for Callaway, Unit 1, Inoperable Instrument Tunnel Sump Level Indication Resulted in Condition Prohibited by Technical Specifications2023-11-29029 November 2023 Submittal of LER 2023-001-00 for Callaway, Unit 1, Inoperable Instrument Tunnel Sump Level Indication Resulted in Condition Prohibited by Technical Specifications ULNRC-06827, Supplement to License Amendment Request Regarding Support System Requirements for Residual Heat Removal and Control Room Air Conditioning Systems Under Technical Specifications 3.4.8, 3.7.11, and 3.9.6 (LDCN 22-0029)2023-11-20020 November 2023 Supplement to License Amendment Request Regarding Support System Requirements for Residual Heat Removal and Control Room Air Conditioning Systems Under Technical Specifications 3.4.8, 3.7.11, and 3.9.6 (LDCN 22-0029) IR 05000483/20230102023-11-15015 November 2023 NRC License Renewal Phase 1 Inspection Report 05000483 2023010 IR 05000483/20233012023-11-0909 November 2023 NRC Examination Report 05000483-2023301 ML23311A2082023-11-0909 November 2023 Reassignment of U.S. Nuclear Regulatory Commission Branch Chief in the Division of Operating Reactor Licensing for Plant Licensing Branch IV ML23297A2502023-11-0606 November 2023 Individual Notice of Consideration of Issuance of Amendment to Renewed Facility Operating License, Proposed No Significant Hazards Consideration Determination and Opportunity for a Hearing (EPID L-2022-LLA-0176) - Letter IR 05000483/20240122023-10-24024 October 2023 Information Request for the Cybersecurity Baseline Inspection, Notification to Perform Inspection (05000483/2024012) ML23293A2652023-10-24024 October 2023 3rd Quarter 2023 Integrated Inspection Report ML23240A3692023-10-0505 October 2023 Issuance of Amendment No. 235 to Revise Technical Specifications to Use of Framatome Gaia Fuel (EPID L-2022-LLA-0150) (Non-Proprietary) ML23234A1522023-10-0505 October 2023 Exemption from the Requirements of 10 CFR Part 50, Section 50.46, and Appendix K Regarding Use of M5 Cladding Material (EPID L-2022-LLE-0030) (Letter) ML23305A0942023-10-0202 October 2023 10-CW-2023-09 Post-Exam Submittal ML23270B9662023-09-27027 September 2023 10 CFR 50.55a(z)(I) Request for Relief from ASME OM Code Pump and Valve Testing Requirements for Fifth 120-Month Inservice Testing Interval ML23228A0252023-09-25025 September 2023 Issuance of Amendment No. 234 to Revise Technical Specification 5.5.16, Containment Leakage Rate Testing Program, for Permanent Extension of Type a and Type C Leak Rate Test Frequencies ML23261C3852023-09-25025 September 2023 Safety Evaluation for Operating Quality Assurance Manual Revision 36A ML23166B0882023-09-20020 September 2023 Issuance of Amendment No. 233 for Adoption of Alternative Source Term and Revision of Technical Specifications ML23206A1992023-09-15015 September 2023 Regulatory Audit Summary Regarding License Amendment and Regulatory Exemptions Request for Fuel Transition to Framatome Gaia Fuel (Epids L-2022-LLA-0150 and L-2022-LLE-0030) IR 05000483/20234012023-09-13013 September 2023 NRC Security Baseline Inspection Report 05000483/2023401 ML23240A7572023-08-31031 August 2023 NRC Initial Operator Licensing Examination Approval 05000483/2023301 IR 05000483/20230052023-08-23023 August 2023 Updated Inspection Plan for Callaway Nuclear Power Plant, Unit 1 (Report 05000483/2023005) - Mid Cycle Letter 2023 ULNRC-06824, Response to Request for Additional Information Regarding Operating Quality Assurance Manual (Oqam) Revision 36A2023-08-17017 August 2023 Response to Request for Additional Information Regarding Operating Quality Assurance Manual (Oqam) Revision 36A ML23219A1392023-08-15015 August 2023 Request for Withholding Information from Public Disclosure ULNRC-06830, Transmittal of Updated Technical Specification Markup and Clean Pages for License Amendment Request to Revise Technical Specification 5.5.16, Containment Leakage Rate Testing Program, for Permanent Extension of Type a and Type C Leak2023-08-15015 August 2023 Transmittal of Updated Technical Specification Markup and Clean Pages for License Amendment Request to Revise Technical Specification 5.5.16, Containment Leakage Rate Testing Program, for Permanent Extension of Type a and Type C Leak ML23215A1972023-08-0303 August 2023 Supplement to License Amendment and Exemption Request Regarding Use of Framatome Gaia Fuel (LDCN 22-0002) ULNRC-06223, Minor Correction to License Amendment Request to Revise Technical Specification 5.5.16, Containment Leakage Rate Testing Program, for Permanent Extension of Type a and Type C Leak Rate Test Frequencies (LDCN 2020-0004)2023-07-25025 July 2023 Minor Correction to License Amendment Request to Revise Technical Specification 5.5.16, Containment Leakage Rate Testing Program, for Permanent Extension of Type a and Type C Leak Rate Test Frequencies (LDCN 2020-0004) ULNRC-06799, Submittal of Licensee Event Report 2022-003-01, Class 1E Electrical Air Conditioning System Thermal Expansion Valve Failure Resulted in Condition Prohibited by Technical Specifications2023-07-13013 July 2023 Submittal of Licensee Event Report 2022-003-01, Class 1E Electrical Air Conditioning System Thermal Expansion Valve Failure Resulted in Condition Prohibited by Technical Specifications IR 05000483/20230022023-07-10010 July 2023 Integrated Inspection Report 05000483/2023002 ML23174A1272023-06-23023 June 2023 Cw FFD Document Request List 2023 ML23171A9942023-06-22022 June 2023 Acceptance of Request for Approval of Operating Quality Assurance Manual Revision 36a ULNRC-06821, Post-Audit Follow-Up Information in Support of Callaway'S License Amendment Request and Proposed Exemption to Allow Use of Framatome Gaia Fuel (LDCN 22-0002) (EPID L-2022-LLA-0150 and EPID L-2022-LLE-00301)2023-06-21021 June 2023 Post-Audit Follow-Up Information in Support of Callaway'S License Amendment Request and Proposed Exemption to Allow Use of Framatome Gaia Fuel (LDCN 22-0002) (EPID L-2022-LLA-0150 and EPID L-2022-LLE-00301) IR 05000483/20230112023-06-15015 June 2023 Comprehensive Engineering Team Inspection (CETI) Inspection Report 05000483/2023011 ULNRC-06822, Additional Information Regarding Request for NRC Approval of Operating Quality Assurance Manual (Oqam) Revision 36a2023-06-14014 June 2023 Additional Information Regarding Request for NRC Approval of Operating Quality Assurance Manual (Oqam) Revision 36a ML23158A1462023-06-13013 June 2023 Notification of Post-Approval Site Inspection for License Renewal and Request for Information Inspection (05000483/2023010) ULNRC-06815, Request for NRC Approval of Operating Quality Assurance Manual, Revision 36a2023-06-0505 June 2023 Request for NRC Approval of Operating Quality Assurance Manual, Revision 36a ULNRC-06818, Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specification 5.5.16, Containment Leakage Rate Testing Program, for Permanent Extension of Type a and Type C Leak Rate .2023-06-0505 June 2023 Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specification 5.5.16, Containment Leakage Rate Testing Program, for Permanent Extension of Type a and Type C Leak Rate . ML23093A0952023-05-10010 May 2023 Issuance of Amendment No. 232 Regarding Technical Specification Changes for Spent Fuel Storage ULNRC-06816, Withdrawal of Previously Submitted Enclosures Regarding License Amendment Request for Adoption of Alternative Source Term and Revision of Technical Specifications (LDCN 21-0015)2023-05-0909 May 2023 Withdrawal of Previously Submitted Enclosures Regarding License Amendment Request for Adoption of Alternative Source Term and Revision of Technical Specifications (LDCN 21-0015) ML23129A7942023-05-0909 May 2023 Post-Audit Supplement to License Amendment Request and Exemption to Allow Use of Framatome Gaia Fuel (LDCN 22-0002) (Iepid L-2022-LLA-0150 and EPID L-2022-LLE-0030) ML23122A3172023-05-0808 May 2023 Review of the Spring 2022 Steam Generator Tube Inservice Inspections ML23118A3492023-05-0808 May 2023 Request for Withholding Information from Public Disclosure 2024-01-29
[Table view] |
Text
~~
WAmeren Callaway Plant MISSOURI December 30,2010 ULNRC-05758 u.s. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 10 CFR 50.90 Ladies and Gentlemen:
DOCKET NUMBER 50-483 CALLAWAY PLANT UNIT 1 UNION ELECTRIC CO.
FACILITY OPERATING LICENSE NPF-30 REQUEST FOR APPROVAL OF THE CALLAWAY PLANT CYBER SECURITY PLAN (LICENSE AMENDMENT REQUEST LDCN 10-0022, TAC NO. ME4536)
References:
- 1. AmerenUE Letter ULNRC-05719, "Request for Approval of the Callaway Plant Cyber Security Plan (License Amendment Request LDCN 10-0022),"
dated August 12,2010
- 2. Electronic Request for Additional Information (RAI) from NRC dated November 30, 2010 By letter dated August 12, 2010 (Reference 1), Union Electric Company (db a AmerenUE, now Ameren Missouri) submitted a request to amend the Facility Operating License (No. NPF-30) for Callaway Plant Unit 1. Specifically, AmerenUE requested NRC approval of Callaway's Cyber Security Plan, provided a proposed Cyber Security Plan Implementation Schedule, and included a proposed revision to the Facility Operating License to incorporate the provisions for implementing and maintaining in effect the provisions of the approved Cyber Security Plan. The license amendment request and proposed Cyber Security Plan were developed in concert with other licensees and the Nuclear Energy Institute (NEI) in accordance with a template( s) developed by NEI.
Per Reference 2 the NRC staff requested additional information in regard to the provisions or requirements of a particular section within the proposed Cyber Security Plan. The attachment hereto provides the requested information.
Th~ conclusions of the licensing evaluations submitted in Reference 1 remain valid and unchanged. In addition, it should be noted that this letter does not contain new commitments.
PO Box 620 Fulton, MO 65251 AmerenMissouri.com
ULNRC-05758 December 30, 2010 Page 2 If there are any questions regarding this letter or the attached information, please contact me at (573) 676-8719 or Mr. Thomas Elwood at (314) 225-1905.
I declare under penalty of perjury that the foregoing is true and correct.
Sincerely, Executed on: I 'L' ", () I .1D l D ;(Jc\)c{ A. ~/
Scott A. Maglio Regulatory Affairs Manager : Response to NRC Request for Additional Information (RAI)
Regarding License Amendment Request LDCN 10-0022 El\1F
VLNRC-05758 December 30,2010 Page 3 cc: U.S. Nuclear Regulatory Commission (Original and 1 copy)
Attn: Document Control Desk Washington, DC 20555-0001 Mr. Elmo E. Collins, Jr.
Regional Administrator U.S. Nuclear Regulatory Commission Region IV 612 E. Lamar Blvd., Suite 400 Arlington, TX 76011-4125 Senior Resident Inspector Callaway Resident Office U. S. Nuclear Regulatory Commission 8201 NRC Road Steedman, MO 65077 Mr. Mohan C. Thadani (2 copies)
Senior Project Manager, Callaway Plant Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Mail Stop 0-8G 14 Washington, DC 20555-2738 Mr. James Polickoski Project Manager, Callaway Plant Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Mail Stop 0-8B 1A Washington, DC 20555-2738
ULNRC-05758 December 30, 2010 Page 4 Index and send hardcopy to QA File A160.0761 Hardcopy:
Certrec Corporation 4200 South Hulen, Suite 422 Fort Worth, TX 76109 (Certrec receives ALL attachments as long as they are non-safeguards and may be publicly disclosed.)
Electronic distribution for the following can be made via Tech Spec ULNRC Distribution:
A. C. Heflin F. M. Diya C. O. Reasoner ill L. S. Sandbothe S. A. Maglio S. L. Gallagher T. L. Woodward (NSRB)
T. B. Elwood E. MFast A. M. Lowry E. A. Wildgen Ms. Diane M. Hooper (WCNOC)
Mr. Tim Hope (Luminant Power)
Mr. Ron Barnes (APS)
Mr. Tom Baldwin (PG&E)
Mr. Wayne Harrison (STPNOC)
Ms. Linda Conklin (SCE)
Mr. John O'Neill (pillsbury Winthrop Shaw Pittman LLP)
Missouri Public Service Commission Mr. Dru Buntin (DNR)
Page lof2 RESPONSE TO NRC REQUEST FOR ADDITIONAL INFORMATION (RAI)
REGARDING LICENSE AMENDMENT REQUEST LDCN 10-0022 Question:
Title 10 of the Code of Federal Regulations (10 CFR) 73.54(b)(I) requires licensees to analyze digital computer and communication systems and networks, and identify those assets that must be protected against cyber attacks. 10 CFR 73.54(e)(I) requires that the cyber security plan must describe how the requirements of this section will be implemented and must account for the site-specific conditions that affect implementation.
The Callaway Plant, Unit 1, Cyber Security Plan (CSP), Section 3.l.5, "Tabletop Reviews and Validation Testing," describes tabletop review and validation activities for the Cyber Security Assessment Team. The CSP further states that the "activities are validated for Critical Digital Assets through a combination of table top reviews and walk-downs."
The purpose of performing physical and electronic walk-downs is to validate that available plant documentation is up to date, accurate and comprehensive. Thus, a walk down, unlike a table top review, can identify and correct documentation issues found by the walkdowns.
Explain the conditions under which the Licensee will use table top reviews rather than conducting actual walk-downs. Please fully identify and document networks and site-specific conditions, to provide assurance that the table top reviews will provide an acceptable level of confidence in validation as the walk-downs would.
Response
F or context, the referenced section is copied below. The text where Ameren deviated from the NEI template is underlined. The sentence containing that text is the subject of the RAI and this response.
(Note: "CDA" in the text below is short for "critical digital asset.")
3.1.5 Tabletop Reviews and Validation Testing The CSAT conducts a tabletop review and validation activities.
Results of table top reviews and validation reviews are documented.
For each CDAlCDAgroup, the CSAT:
- Confirms direct and indirect connectivity pathways;
- Confirms infrastructure interdependencies;
- Reviews any CDA assessment documentation;
- Reviews the defensive strategies; Page 2 of2
- Reviews the defensive models;
- Confirms the implementation of plant-wide physical and cyber security policies and procedures that secure the CDAs from a cyber attack, including attack mitigation, and incident response and recovery;
- Confirms that staff members working with the CDAs are trained to a level of cyber security knowledge commensurate with their assigned responsibilities; and
- Identifies and documents the CDA cyber security exposures including specific attack/threat vectors to be assessed for mitigation using the method in Section 3. 1.6.
The above activities are validated for CDAs through a combination of table top reviews and walk-downs.
Ameren intends to physically walk-down every CDA in accordance with NRC expectations. Ameren believes, however, that it is not possible to validate some items in the above list by doing a physical walk-down. Some validation items, such as confirming that staff members working with the CDAs have the proper training, can only be validated by table top or document review. Ameren therefore attempted to clarify that this validation would require some documentation reviews in addition to physical walk-downs. This was not intended as an "or" statement and Ameren did not plan to perform table top reviews in lieu of walk-downs on any systems. Consequently, no networks or site-specific conditions need to be identified and no justification is required to assure that a table top review will provide the same level of confidence as a physical walk-down.