September 15, 2023 Mr. Fadi Diya Senior Vice President and Chief Nuclear Officer Ameren Missouri Callaway Energy Center 8315 County Road 459 Steedman, MO 65077
SUBJECT:
CALLAWAY PLANT, UNIT NO. 1 - REGULATORY AUDIT
SUMMARY
REGARDING LICENSE AMENDMENT AND REGULATORY EXEMPTION REQUESTS FOR FUEL TRANSITION TO FRAMATOME GAIA FUEL (EPIDS L-2022-LLA-0150 AND L-2022-LLE-0030)
Dear Mr. Diya:
By letter dated October 12, 2022 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML22285A115), as supplemented by letters dated December 1, 2022, May 9, 2023, June 21, 2023, and August 3, 2023 (ML22335A497, ML23129A793, ML23172A145, and ML23215A196, respectively), Union Electric Company, doing business as Ameren Missouri (the licensee), pursuant to Title 10 of the Code of Federal Regulations (10 CFR) Section 50.90, Application for amendment of license, construction permit, or early site permit, requested an amendment and regulatory exemptions regarding the use of Framatome GAIA fuel for Callaway Plant, Unit No. 1 (Callaway).
The proposed amendment would revise the Callaway Technical Specifications to allow use of Framatome GAIA fuel with M5 as a fuel cladding material. Since the Framatome GAIA fuel will use M5 fuel rod cladding, a 10 CFR 50.46, Acceptance criteria for emergency core cooling systems for light-water nuclear power reactors, and 10 CFR Part 50, Appendix K, ECCS
[Emergency Core Cooling System] Evaluation Models, exemption request is included as part of this licensing amendment request (LAR).
To support its review of the LAR, the U.S. Nuclear Regulatory Commission (NRC) staff conducted a regulatory audit virtually using an online portal. The NRC staff requested information during the initial phase of the audit, which was uploaded to the online portal by the licensee, for NRC staffs review. The virtual regulatory audit meeting was held between the NRC staff and the licensee representatives from April 3-5, 2023, during which the NRC staff held discussions with the licensee. The audit was kept open to submit additional audit questions and to conduct follow-up audit discussions. The regulatory audit summary report is enclosed with this letter.
If you have any questions, please contact me at 301-415-8371 or via email at Mahesh.Chawla@nrc.gov.
Sincerely,
/RA/
Mahesh L. Chawla, Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-483
Enclosure:
Regulatory Audit Summary cc: Listserv
Enclosure REGULATORY AUDIT
SUMMARY
IN SUPPORT OF LICENSE AMENDMENT AND REGULATORY EXEMPTION REQUESTS FOR FUEL TRANSITION TO FRAMATOME GAIA FUEL UNION ELECTRIC COMPANY CALLAWAY PLANT, UNIT NO. 1 DOCKET NO. 50-483
1.0 BACKGROUND
By letter dated October 12, 2022 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML22285A115), as supplemented by letters dated December 1, 2022, May 9, 2023, June 21, 2023, and August 3, 2023 (ML22335A497, ML23129A793, ML23172A145, and ML23215A196, respectively), Union Electric Company, doing business as Ameren Missouri (the licensee), pursuant to Title 10 of the Code of Federal Regulations (10 CFR) Section 50.90, Application for amendment of license, construction permit, or early site permit, requested an amendment and regulatory exemptions regarding the use of Framatome GAIA fuel for Callaway Plant, Unit No. 1 (Callaway).
The proposed amendment would revise the Callaway Technical Specifications to allow use of Framatome GAIA fuel with M5 as a fuel cladding material. Since the Framatome GAIA fuel will use M5 fuel rod cladding, a 10 CFR 50.46, Acceptance criteria for emergency core cooling systems for light-water nuclear power reactors, and 10 CFR Part 50, Appendix K, ECCS
[Emergency Core Cooling System] Evaluation Models, exemption request is included as part of this licensing amendment request (LAR). The information submitted in support of the LAR is under final review in accordance with the Office of Nuclear Reactor Regulation (NRR) Office Instruction LIC-101, Revision 6, License Amendment Review Procedures (ML19248C539).
The U.S. Nuclear Regulatory Commission (NRC) staff conducted a regulatory audit in accordance with the NRR Office Instruction LIC-111, Regulatory Audits (ML19226A274). The regulatory audit is a planned license or regulation-related activity that includes the examination and evaluation of primarily non-docketed information. The regulatory audit is conducted with the intent to gain understanding, to verify information, and/or to identify information that will require docketing to support the basis of a licensing or regulatory decision. Performing a regulatory audit of the licensees information is expected to assist the NRC staff in efficiently conducting its review or gain insights on the licensees processes or procedures. Information that the NRC staff relies upon to make the safety determination must be submitted on the docket.
During the regulatory audit, the NRC staff reviewed documents, responses to audit questions, and held discussions with members of Ameren Missouri and its contractors. The purpose of the audit was to gain an understanding of the information needed to support the NRC staffs licensing decision regarding the LAR and to develop requests for additional information (RAIs).
However, the NRC staff may review supporting information retained as records under 10 CFR 50.71, Maintenance of records, making of reports, and/or 10 CFR 54.37, Additional records and recordkeeping requirements, which, although not required to be submitted as part of the licensing action, would help the NRC staff better understand the licensees submitted information.
2.0 AUDIT ACTIVITIES AND OBSERVATIONS 2.1 Desk and Virtual Audit The desk audit was conducted by the NRC staff consistent with the regulatory audit plan dated March 20, 2023 (ML23068A377). The NRC staff provided the list of documents needed in the audit plan along with audit questions. The licensee uploaded the requested documents to an electronic portal and provided access to the NRC audit team. The NRC staff reviewed the documents during the desk-audit phase made available by the licensee in an electronic reading room.
The second phase of the audit was conducted virtually in meetings between the dates of April 3-5, 2023, and subsequent follow-up meetings. Detailed discussions were held on various topics between the audit team members and the licensee, aided by information needs identified by the NRC staff in the audit plan, as supplemented, along with the licensees presentations and prepared responses to audit questions.
In addition, the NRC requested via emails dated April 17, 2023 (ML23107A181), and April 24, 2023 (ML23114A230), that responses be provided to additional questions discussed during a call held on April 20, 2023. At the conclusion of the audit activities, the NRC requested that the licensees responses to selected questions from the audit be transmitted via a letter, which was subsequently provided by the supplemental letter dated May 9, 2023. Following review of the responses provided in the supplement dated May 9, 2023, a call was held on June 8, 2023, during which the NRC staff requested that additional information be provided regarding four items, which was provided by the licensee in the supplemental [[letter::ULNRC-06821, Post-Audit Follow-Up Information in Support of Callaways License Amendment Request and Proposed Exemption to Allow Use of Framatome Gaia Fuel (LDCN 22-0002) (EPID L-2022-LLA-0150 and EPID L-2022-LLE-00301)|letter dated June 21, 2023]].
The NRC staff used the information gathered from the audit to determine whether additional information is warranted on the docket to support rendering of an NRC staff finding. The audit plan dated March 20, 2023, provides a list of the information that the NRC staff reviewed throughout the audit.
3.0 RESULTS OF THE AUDIT The NRC staff did not make any regulatory decisions regarding the LAR during the audit. At the audit exit meeting held on April 5, 2023, and during subsequent meetings, the NRC staff reviewed the proposed resolution to the audit questions with the licensee, and reached a consensus regarding the questions, which were resolved and closed. The licensee provided the response to the remainder of the questions on the docket in the supplements dated May 9, 2023, and June 21, 2023. After reviewing the supplemented information, the NRC staff has not identified the need for any RAI.
List of Participants U.S Nuclear Regulatory Commission (NRC) Audit Team NRC Staff Role Mahesh Chawla Project Manager, NRR1/DORL2/LPL43 Ahsan Sallman Senior Nuclear Engineer, NRR/DSS4/SNSB5 Santosh Bhatt Nuclear Engineer, NRR/DSS/SNSB Mathew Panicker Nuclear Engineer, NRR/DSS/SFNB6 Ravi Grover Safety and Plant Systems Engineer, NRR/DSS/STSB7 Gerry Stirewalt Senior Environmental Project Manager, NMSS8/REFS9/ERNB10 Donald Palmrose Senior Reactor Engineer, NMSS/REFS/ERNB Ameren Missouri - Callaway Plant, Unit 1 (Callaway) Team Thomas Elwood - Supervisor, Licensing and Regulatory Affairs Thomas Forland - Licensing Engineer Brian Richardson - Supervisor, Reactor Engineering and Safety Analysis James Knaup - Reactor Engineer Justen Vinyard - Reactor Engineer Chris Ehmke - Reactor Engineer Jonathan Cordz - Safety Analysis Engineer Kurt Linsenbardt - Safety Analysis Engineer Larry Russell - Project Manager, consultant James McInvale - Reactor Engineering consultant Donald Rickard - Licensing consultant Garry Chapman - Engineering consultant Framatome personnel include:
Rick Williamson - Contract Manager Tom Gardner - Project Manager Morris Byram - Licensing/Reg Affairs John Adams - Safety Analysis Supervisor Tim Lindquist - Safety Analysis Engineer Jackson Breakell - TH Engineer Mike Bingham - TH Engineer Brittany Williams - LOCA Engineer Nathan Hottle - LOCA Supervisor Mirielle Cortes - LOCA Engineer Mike Aldrich - Fuel Performance (Thermal-Mechanics) Engineer 1 Office of Nuclear Reactor Regulation (NRR) 2 Division of Operating Reactor Licensing (DORL) 3 Plant Licensing Branch IV 4 Division of Safety Systems 5 Nuclear Systems Performance Branch 6 Nuclear Methods and Fuel Analysis Branch 7 Technical Specifications Branch 8 Office of Nuclear Material Safety and Safeguards 9 Division of Rulemaking, Environmental, and Financial Support 10 Environmental New Reactor Branch Michael Harris - Fuel Performance (T-M) Engineer Brian Painter - Structural Mechanics Engineer Dan Colleran - Structural Mechanics Supervisor Kevin Roberts - Neutronics Engineer Kevin Segard - Neutronics Engineer Michelle Guzzardo - Neutronics Supervisor Graeme Leitch - Mechanical Design Engineer
- by email OFFICE NRR/DORL/LPL4/PM NRR/DORL/LPL4/LA NRR/DSS/SFNB/BC NAME MChawla PBlechman SKrepel DATE 08/01/2023 07/27/2023 08/10/2023 OFFICE NRR/DSS/SNSB/BC*
NRR/DSS/STSB/BC*
NRR/DRO/IQVB/BC*
NAME PSahd VCusumano KKavanagh DATE 08/01/2023 08/10/2023 08/04/2023 OFFICE NMSS/REFS/ERNRB/BC* NRR/DORL/LPL4/BC*
NRR/DORL/LPL4/PM*
NAME JOHara (for K Erwin)
JDixon-Herrity MChawla DATE 08/02/2023 09/15/2023 09/15/2023