MONTHYEARML0506900352005-03-0303 March 2005 Response to NRC Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors Project stage: Request ML0515100172005-05-31031 May 2005 Draft RAI on Response to Generic Letter 2004-02 Project stage: Draft RAI ML0515303042005-06-0303 June 2005 6/3/05, Calvert Cliffs - RAI Potential Impact of Debris Blockage on Emergency Sump Recirculation at Pressurized-Water Reactors Project stage: RAI ML0520200572005-07-15015 July 2005 Response to NRC Request for Additional Information Re NRC Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors Project stage: Response to RAI ML0603703472006-02-0909 February 2006 RAI, Response to Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design-Basis Accidents at Pressurized-Water Reactors Project stage: RAI ML0603704272006-02-0909 February 2006 Request for Additional Information Response to Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design-Basis Accidents at Pressurized-water Reactors (TAC MC4692 & MC4693) Project stage: RAI ML0603803582006-02-0909 February 2006 RAI, Response to Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design-Basis Accidents at Pressurized-Water Reactors Project stage: RAI ML0608904212006-03-0101 March 2006 Final Safety Evaluation Report Related to the License Renewal of Brunswick Steam Electric, Units 1 and 2 Project stage: Approval ML0609500512006-04-12012 April 2006 Approval of Extension Request for Completion of Corrective Actions in Response to Generic Letter 2004-02 Project stage: Other ML0618702222006-06-30030 June 2006 Update of Response to Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Basis Accidents at Pressurized Water Reactors Project stage: Other ML0626405472006-09-20020 September 2006 Update of Response to Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors Project stage: Other ML0633407022006-12-18018 December 2006 Unit No.1 - Approval of Extension Request for Completion of Corrective Action in Response to Generic Letter 2004-02 Project stage: Other ML0712703722007-05-0202 May 2007 Revision to Generic Letter 2004-02 Response Project stage: Other ML0733103812007-11-21021 November 2007 Notification of Potential Part 21 Report Welding of Safety Related Components Project stage: Request ML0734604102007-12-0707 December 2007 Request for Extension of Completion Dates for Corrective Actions Required by NRC Generic Letter (GL) 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Project stage: Request ML0734504992007-12-10010 December 2007 Attachment (1) Request for Extension of the Completion Date for Corrective Actions Related to Generic Letter 2004-02 Project stage: Request ML0734504982007-12-10010 December 2007 Request for Extension for Completion of Activities Related to Generic Letter 2004-02 Project stage: Request ML0736102262007-12-28028 December 2007 Notice of Meeting with Duke Power Company to Discuss the Relief Request Dated 10/26/2006 That Proposes the Use of Polyethylene Material in Nuclear Safety-Related Piping Applications Project stage: Meeting ML0807301312008-02-28028 February 2008 Response to Request for Additional Information on GL-04-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors Project stage: Response to RAI ML0806505592008-02-29029 February 2008 Response to Request for Additional Information on GL-04-002 Project stage: Response to RAI ML0811307392008-04-22022 April 2008 Revision to Generic Letter 2004-02 Response Project stage: Other ML0812804882008-04-30030 April 2008 Response to NRC Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors Project stage: Request ML0812700912008-04-30030 April 2008 Response to NRC Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors Project stage: Request ML0817101052008-06-18018 June 2008 Attachment 1, Request for Extension of the Completion Date for Corrective Actions Related to Generic Letter 2004-02 Project stage: Request ML0827404892008-09-30030 September 2008 Supplemental Response to Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized Water Reactors Project stage: Supplement ML0827404972008-09-30030 September 2008 Attachment 2, ECCS and CS System Figures Project stage: Other ML0830803502008-11-18018 November 2008 Request for Additional Information (RAI) Regarding Supplemental Responses to Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized Project stage: RAI ML0830803732008-11-21021 November 2008 RAI, Supplemental Responses to Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized Water Reactors Project stage: RAI ML0833003202008-12-0404 December 2008 Request for Additional Information Supplemental Response to Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized Water Reactors-Calvert Cliffs Unit 1 & 2 Project stage: RAI ML0906807672009-03-0404 March 2009 Request for Additional Information: Supplemental Response to Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized Water Reactors Project stage: Supplement ML0921101202009-07-28028 July 2009 Update on the Status of the November 21, 2008 Request for Additional Information (RAI) and Additional Testing Pursuant to NRC Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation Project stage: Request ML0921605972009-07-28028 July 2009 Update on Status of 11/18/08 Request for Additional Information & Additional Testing Pursuant to GL 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized Water Reactors Project stage: Request ML0922908922009-08-18018 August 2009 Notice of Conference Call with Duke Energy Carolinas, LLC (Duke), Regarding Catawba Nuclear Station, Units 1 and 2 (Catawba 1 and 2) and McGuire Nuclear Station Units 1 and 2 Project stage: Other ML0927304602009-10-0707 October 2009 Summary of Conference Call with Duke Regarding Responses to Generic Letter (GL) 2004-02. Meeting Handouts Project stage: Request ML0926700202009-10-0707 October 2009 Summary of Conference Call with Duke Regarding Responses to Generic Letter (GL) 2004-02 Project stage: Other ML1009500782010-04-12012 April 2010 Request for Additional Information Generic Letter 2004-02 Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2- Project stage: RAI ML1011903842010-05-0606 May 2010 Notice of Forthcoming Conference Call with Calvert Cliffs to Discuss Supplemental Responses to Generic Ltr. 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized Water Reactors Project stage: Request ML1012604632010-05-0707 May 2010 Notice of Forthcoming Conference Call with Duke Energy Carolinas, LLC (Duke) to Discuss Dukes Responses to Generic Letter 2004-02 at Catawba 1 and 2 and McGuire 1 and 2 Project stage: Other ML1014708982010-06-0707 June 2010 Summary of Meeting with Calvert Cliffs Nuclear Power Plant, LLC, to Discuss Supplement to Responses to Generic Letter 2004-02 Project stage: Meeting ML1028701002010-09-30030 September 2010 Draft Responses to NRC Request for Additional Information Related to Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents on Pressurized-Water.. Project stage: Draft Response to RAI ML1029306502010-10-20020 October 2010 Notice of Forthcoming Conference Call with Duke Energy Carolinas, LLC Regarding McGuire Nuclear Station, Units 1 and 2 and Catawba Nuclear Station, Units 1 and 2, Project stage: Other ML1030810242010-11-10010 November 2010 Summary of November 1, 2010, Meeting with Duke to Discuss Responses to Generic Letter (GL) 2004-02 (Tac Nos. MC4673, MC4674, MC4692, and MC4693) Project stage: Meeting ML1031903612010-11-10010 November 2010 Response to Request for Additional Information Regarding Generic Letter 2004-02 Project stage: Response to RAI ML12356A0852012-12-27027 December 2012 January 8, 2013 - Notice of Teleconference with Calvert Cliffs Nuclear Power Plant, LLC Project stage: Meeting ML13038A5432013-01-24024 January 2013 Chemical Effects Head Loss Experiment (Chle) Test Protocol for Calvert Cliffs Nuclear Power Plant (CCNPP-CHLE-002, Revision 0d) Project stage: Request ML13038A6042013-01-24024 January 2013 PIRT Item Summary Project stage: Request ML13038A4872013-01-24024 January 2013 CCNPP-CHLE-001, Revision 0c, Chemical Effects Head Loss Experiment (Chle) Test Plan for Calvert Cliffs Nuclear Power Plant Project stage: Request ML13086A5512013-01-24024 January 2013 MC4672 & MC4673 - CCNPP-CHLE-003, Rev 0c Chemical Effects PIRT Considerations Excerpts with Respect to GL2004-02, GSI-191 Project stage: Other ML13038A5782013-01-24024 January 2013 Chemical Effects Pirt Considerations for Calvert Cliffs Nuclear Power Plant (CCNPP-CHLE-003, Revision 0b) Project stage: Request ML13030A3482013-02-0707 February 2013 Summary of Teleconference with Calvert Cliffs Nuclear Power Plant, Units 1 and 2 to Discuss Proposed Risk-Informed Approach to the Resolution of Generic LTR 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Des Project stage: Meeting 2008-02-28
[Table View] |
Summary of November 1, 2010, Meeting with Duke to Discuss Responses to Generic Letter (GL) 2004-02 (Tac Nos. MC4673, MC4674, MC4692, and MC4693)| ML103081024 |
| Person / Time |
|---|
| Site: |
Mcguire, Catawba, McGuire  (NPF-009, NPF-017, NPF-035, NPF-052) |
|---|
| Issue date: |
11/10/2010 |
|---|
| From: |
Jacqueline Thompson Plant Licensing Branch II |
|---|
| To: |
Duke Energy Carolinas |
|---|
| Thompson Jon, NRR/DORL/LPL 2-1, 415-1119 |
| Shared Package |
|---|
| ML103140192 |
List: |
|---|
| References |
|---|
| TAC MC4673, TAC MC4674, TAC MC4692, TAC MC4693, GL-04-002 |
| Download: ML103081024 (2) |
|
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 November 10, 2010 LICENSEE:
DUKE ENERGY CAROLINAS, LLC (DUKE)
FACILITY:
CATAWBA NUCLEAR STATION, UNITS 1 AND 2, AND MCGUIRE NUCLEAR STATION, UNITS 1 AND 2 SUB..IECT:
SUMMARY
OF NOVEMBER 1, 2010, MEETING WITH DUKE TO DISCUSS RESPONSES TO GENERIC LEDER (GL) 2004-02 FOR THE MCGUIRE NUCLEAR STATION (MCGUIRE) AND THE CATAWBA NUCLEAR STATION (CATAWBA) (TAC NOS. MC4673, MC4674, MC4692, AND MC4693)
On November 1, 2010, a Category 1 public meeting via conference call was held between the U.S. Nuclear Regulatory Commission (NRC) and representatives of Duke at NRC Headquarters, One White Flint North, 11555 Rockville Pike, Rockville, Maryland. The purpose of the meeting was to discuss Duke's responses to GL 2004-02. A list of attendees is enclosed.
The licensee discussed the status of upcoming tests to address issues raised by the requests for additional information (RAls) sent by the NRC staff's letters dated November 18, 2008 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML083080350), for McGuire and November 21, 2008 (ADAMS Accession No. ML083080373),
for Catawba. The next set of tests is scheduled to begin later in November 2010 and had been delayed to make additional modifications to the test equipment in order to ensure representative testing conditions. The licensee and the NRC also briefly discussed draft RAI responses sent by letter dated September 30, 2010 (ADAMS Accession No. ML102870100), with a particular focus on those responses that may be impacted by the upcoming testing. The NRC staff indicated that major issues, and the associated RAI responses, appear as if they will be addressed with the upcoming testing, which should be confirmatory.
Members of the public were not in attendance. Public Meeting Feedback forms were not received. Please direct any inquiries to me at 301-415-1119, or jon.thompson@nrc.gov.
Cf~nIA. ~--,~
Jon H. Thompson, Project Manager Plant Licensing Branch 11-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-413, 50-414, 50-369, and 50-370
Enclosure:
List of Attendees cc w/encl: Distribution via Listserv
LIST OF ATrENDEES NOVEMBER 1, 2010, NUCLEAR REGULATORY COMMISSION (NRC) MEETING WITH DUKE ENERGY CAROLINAS, LLC (DUKE), ON DISCUSSION OF LICENSEE'S RESPONSES TO GENERIC LEITER 2004-01 NRC S. Bailey J. Thompson S. Smith J. Lehning P. Klein*
- Participated by phone DUKE K. Ashe*
R. Hart*
J. Nolin*
S. Manning*
P. Roberson*
R. Lytton*
A. Tuckman*
G. Robison*
M. Branham*
E. Crabtree*
Enclosure
ML083080373),
for Catawba. The next set of tests is scheduled to begin later in November 2010 and had been delayed to make additional modifications to the test equipment in order to ensure representative testing conditions. The licensee and the NRC also briefly discussed draft RAI responses sent by letter dated September 30,2010 (ADAMS Accession No. ML102870100), with a particular focus on those responses that may be impacted by the upcoming testing. The NRC staff indicated that major issues, and the associated RAI responses, appear as if they will be addressed with the upcoming testing, which should be confirmatory.
Members of the public were not in attendance. Public Meeting Feedback forms were not received. Please direct any inquiries to me at 301-415-1119, or jon.thompson@nrc.gov.
IRA!
Jon H. Thompson, Project Manager Plant Licensing Branch 11-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-413, 50-414, 50-369, and 50-370
Enclosure:
List of Attendees cc w/encl: Distribution via Listserv DISTRIBUTION:
PUBLIC RidsNrrLAMO'Brien Resource RidsNrrDssSsib Resource LPL2-1 RlF RidsOgcRp Resource RidsNrrDciCsgb Resource RidsAcrsAcnw_MailCTR Resource RidsOpaMail Resource PKlein, NRR RidsNrrOdResource RidsRgn2MailCenter Resource SSmith, NRR RidsNrrDorl Resource TWertz, NRR JLehning, NRR RidsNrrDorlLpl2-1 Resource CSteger, NRR SBailey, NRR RidsNrrPMCatawba Resource JLedford, OPA Region II NSanfilippo, EDO Region II RidsNrrPMMcGuire Resource RHannah, OPA Region \\I M