ML101540242

From kanterella
Jump to navigation Jump to search

Request for Additional Information for Salem Nuclear Generating Station Units 1 and 2 License Renewal Application for Buried Piping Inspection Program (TAC Nos. ME1834 and ME1836)
ML101540242
Person / Time
Site: Salem  PSEG icon.png
Issue date: 08/06/2010
From: Bennett Brady
License Renewal Projects Branch 1
To: Joyce T
Public Service Enterprise Group
Brady B NRR/DLR/RPB1, 415-2981
References
TAC ME1834, TAC ME1836, FOIA/PA-2010-0334
Download: ML101540242 (4)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 August6,2010 Mr. Thomas Joyce President and Chief Nuclear Officer PSEG Nuclear LLC P.O. Box 236 Hancocks Bridge, NJ 08038

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR SALEM NUCLEAR GENERATING STATION UNITS 1 AND 2 LICENSE RENEWAL APPLICATION FOR BURIED PIPING INSPECTION PROGRAM (TAC NOS. ME1834 AND ME1836)

Dear Mr. Joyce:

By letter dated August 18, 2009, Public Service Enterprise Group Nuclear, LLC, submitted an application pursuant to Title 10 of the Code of Federal Regulations Part 54 for renewal of Operating License Nos. DPR-70 and DPR-75 for Salem Nuclear Generating Station Units 1 and 2, respectively. The staff of the U.S. Nuclear Regulatory Commission (NRC or the staff) is reviewing this application in accordance with the guidance in NUREG-1800, "Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants." During its review, the staff has identified areas where additional information is needed to complete the review.

The staff's request for additional information is included in the Enclosure. Further requests for additional information may be issued in the future.

Items in the enclosure were provided to John Hufnagel and other members of your staff, and a mutually agreeable date for the response is within 30 days from the date of this letter. If you have any questions, please contact me by telephone at 301-415-2981 or bye-mail at bennett.brady@nrc.gov.

Sincerely, Bennett M. Brady, Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-272 and 50-311

Enclosure:

As stated cc w/encl: Distribution via Listserv

REQUEST FOR ADDITIONAL INFORMATION FOR SALEM NUCLEAR GENERATING STATION UNITS 1 AND 2 LICENSE RENEWAL APPLICATION FOR BURIED PIPING INSPECTION PROGRAM (TAC NOS. ME1834 AND ME1836)

RAt 6.2.1.22

Background:

The license renewal application (LRA) states that the aging management program (AMP)

B.2.1.22, Buried Piping Inspection Program, is an existing program with one enhancement and is consistent with the program elements in GALL AMP XI.M34. This AMP addresses buried piping (i.e., piping in direct contact with soil). The LRA also states that AMP B.2.1.24, Extemal Surfaces Monitoring Program, is a new program and is consistent with the program elements in GALL AMP XI.M36. This AMP addresses aging management of the external surfaces of piping exposed to air, which would normally include underground inaccessible piping (i.e., piping not in direct contact with soil, but located below grade in a vault, pipe chase, or other structure where it is exposed to air and where access is limited).

There have been a number of recent industry events involving leakage from buried and underground piping and tanks.

Issue:

In light of this recent industry operating experience (OE), the staff is concerned about the continued susceptibility to failure of buried and/or underground piping that are within the scope of 10 CFR 54.4 and subject to aging management for license renewal. In reviewing the AMPs cited above along with the applicable aging management review (AMR) items associated with them, the staff is not clear whether: (1) the components addressed by these AMPs clearly include both buried and underground piping (piping which is below grade and contained in a vault or other structure where it is exposed to air and where access is limited); and (2) whether such programs are being updated to incorporate lessons learned from these recent events as well as any OE from the applicant's own history.

Request:

1. Provide a list and a brief summary of any leaks or adverse conditions discovered during inspections (e.g., coating damage that directly exposes the piping or tank to the environment, presence of any coarse material in backfill within six inches of the pipe or tank, unexpected corrosion or damage to piping walls or component pressure boundaries) which have occurred in buried or underground piping or tanks at the station in the past five years that were entered in your corrective action program but are not included in your LRA. Describe how your current AMPs or proposed changes to the AMPs address these issues.
2. Provide a discussion of how the AMPs used in managing the aging of buried and underground piping and tanks within the scope of license renewal will address recent industry OE as well as any OE from the applicant's own history.

ENCLOSURE

August 6,2010 Mr. Thomas Joyce President and Chief Nuclear Officer PSEG Nuclear LLC P.O. Box 236 Hancocks Bridge, NJ 08038

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR SALEM NUCLEAR GENERATING STATION UNITS 1 AND 2 LICENSE RENEWAL APPLICATION FOR BURIED PIPING INSPECTION PROGRAM (TAC NOS. ME1834 AND ME1836)

Dear Mr. Joyce:

By letter dated August 18,2009, Public Service Enterprise Group Nuclear, LLC, submitted an application pursuant to Title 10 of the Code of Federal Regulations Part 54 for renewal of Operating License Nos. DPR-70 and DPR-75 for Salem Nuclear Generating Station Units 1 and 2, respectively. The staff of the U.S. Nuclear Regulatory Commission (NRC or the staff) is reviewing this application in accordance with the guidance in NUREG-1800, "Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants." During its review, the staff has identified areas where additional information is needed to complete the review.

The staff's request for additional information is included in the Enclosure. Further requests for additional information may be issued in the future.

Items in the enclosure were provided to John Hufnagel and other members of your staff, and a mutually agreeable date for the response is within 30 days from the date of this letter. If you have any questions, please contact me by telephone at 301-415-2981 or bye-mail at bennett.brady@nrc.gov.

Sincerely, IRA!

Bennett M. Brady, Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-272 and 50-311

Enclosure:

As stated cc w/encl: Distribution via Listserv DISTRIBUTION:

See next page ADAMS Accession No ML101540242 OFFICE PM:DLR:RPB1 LA:DLR BC:DLR:RPB1 PM:DLR:RPB1 NAME B. Brady I. King B. Pham B. Brady DATE 08/05/10 06/04/10 08/06/10 08/06/10 OFFICIAL RECORD COpy

Letter to T. Joyce from B. Brady dated August 6,2010

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR SALEM NUCLEAR GENERATING STATION UNITS 1 AND 2 LICENSE RENEWAL APPLICATION FOR BURIED PIPING INSPECTION PROGRAM (TAC NOS. ME1834 AND ME1836)

DISTRIBUTION:

HARDCOPY:

DLR RF E-MAIL:

PUBLIC RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDlrRarb Resource RidsNrrDlrRasb Resource RidsNrrDlrRapb Resource RidsOgcMailCenter Resource BPham BBrady CEccleston REnnis CSanders BHarris, OGC ABurritt, RI RConte, RI MModes, RI DTifft, RI NMcNamara, RI