Letter Sequence RAI |
|---|
TAC:ME1834, Control Room Habitability (Approved, Closed) TAC:ME1836, Control Room Habitability (Approved, Closed) |
Results
Other: LR-N11-0057, Close-out of the NRC Audit Associated with Use of Westems Tm Related to the License Renewal Application, LR-N16-0144, Completion of Activities to Support Entry Into the Period of Extended Operation, ML092400531, ML092400532, ML092430231, ML092460442, ML092470039, ML092520185, ML092650382, ML092660174, ML092660447, ML100850206, ML100850459, ML102280211, ML102430586, ML110871243, ML11125A024
|
MONTHYEARML0924005312009-08-18018 August 2009 PSEG Nuclear, Salem Nuclear Generating Station, Units 1 and 2, License Renewal Application, Volume 2 of 3 Project stage: Other ML0924302312009-08-18018 August 2009 PSEG Nuclear, Salem Nuclear Generating Station, Units 1 and 2, License Renewal Application, Volume 1 of 3 Project stage: Other LR-N09-0161, PSEG Nuclear, Salem Nuclear Generating Station, Units 1 and 2, Transmittal of License Renewal Application2009-08-18018 August 2009 PSEG Nuclear, Salem Nuclear Generating Station, Units 1 and 2, Transmittal of License Renewal Application Project stage: Request ML0924005322009-08-18018 August 2009 PSEG Nuclear, Salem Nuclear Generating Station, Units 1 and 2, License Renewal Application, Volume 3 of 3 Project stage: Other LR-N09-0192, Information to Support NRC Staff Review of the Application for Renewed Operating License2009-08-18018 August 2009 Information to Support NRC Staff Review of the Application for Renewed Operating License Project stage: Request ML0924604422009-09-0303 September 2009 Delaware Citizen Comment on Salem Hope Creek License Renewal Application Project stage: Other ML0924700392009-09-0404 September 2009 Comment on Salem - Hope Creek License Renewal Applications from Citizen Project stage: Other ML0926601742009-09-0707 September 2009 Comment on License Renewal for Salem and Hope Creek Power Plants - Goodman Project stage: Other ML0925201852009-09-0808 September 2009 Comments About Relicensing Salem and Hope Creek Reactors in Nj, Steven Hegedus Project stage: Other ML0926503822009-09-0808 September 2009 Citizen Comment on Salem Hope Creek License Renewal Application Project stage: Other ML0926604472009-09-23023 September 2009 E-mail from Ruth Panella Comments on License Renewal Project stage: Other ML1008502062010-03-24024 March 2010 Task Order No. 004 Under Delivery Order No. NRC-DR-03-09-061 Project stage: Other ML1008504592010-04-0606 April 2010 Project Manager Change for the License Renewal of Salem Nuclear Generating Station, Units 1 and 2 Project stage: Other ML1007606612010-04-14014 April 2010 RAI Regarding Balance of Plant Scoping and Screening Results for the Salem Nuclear Generating Station Units 1 & 2 (Tac Nos. ME1834 and ME1836) Project stage: RAI ML1010300252010-04-15015 April 2010 Request for Additional Information Regarding ASME Section XI, Subsection IWE for the Salem Nuclear Generating Station Units 1 and 2 License Renewal Application (TAC Me 1836 and Me 1834) Project stage: RAI ML1010204812010-04-30030 April 2010 Request for Additional Information Regarding Scoping and Screening Methodology for the Salem Nuclear Generating Station Units 1 and 2 License Renewal Application Project stage: RAI ML1013805112010-05-24024 May 2010 Request for Additional Information for the Salem Generating Station, Units 1 and 2, License Renewal Application, Section 3.3.2 Project stage: RAI LR-N10-0191, Response to NRC Request for Additional Information Dated April 30, 2010, Regarding Scoping and Screening Methodology for License Renewal Application2010-05-28028 May 2010 Response to NRC Request for Additional Information Dated April 30, 2010, Regarding Scoping and Screening Methodology for License Renewal Application Project stage: Response to RAI ML1014600612010-06-0707 June 2010 Request for Additional Information for Salem Nuclear Generating Station Units 1 and 2 License Renewal Application Regarding Section 3.5 Project stage: RAI ML1014600772010-06-10010 June 2010 Request for Additional Information for Salem Nuclear Generating Station Units 1 and 2 License Renewal Application Project stage: RAI ML1014400812010-06-10010 June 2010 Request for Additional Information for the Review of the Salem Generating Station, Unit 1 and Unit 2, License Renewal Application Identified During the Audit Project stage: RAI ML1014810092010-06-11011 June 2010 Request for Additional Information for Salem Nuclear Generating Station Units 1 and 2 License Renewal Application Project stage: RAI ML1015504712010-06-11011 June 2010 RAI for Salem Nuclear Generating Station Units 1 and 2 License Renewal Application Sections 3.1.2 and 3.3.2 (TAC No ME1834/ME1836) Project stage: RAI ML1014801892010-06-14014 June 2010 Request for Additional Information for Salem Nuclear Generating Station Units 1 and 2 License Renewal Application Regarding Sections 4.3 and 4.4 Project stage: RAI ML1013905372010-06-17017 June 2010 Request for Additional Information for Salem Nuclear Generating Station Units 1 and 2 License Renewal Application Project stage: RAI ML1016201902010-06-25025 June 2010 Request for Additional Information for Salem Nuclear Generating Station Units 1 and 2, License Renewal Application (Tac ME1834/ME1836) Project stage: RAI ML1016804022010-06-29029 June 2010 Request for Additional Information for Salem Nuclear Generating Station Units 1 and 2, License Renewal Application Regarding Subsection 3.1.2.2.14 (TAC ME1834/ME1836) Project stage: RAI ML1014807262010-06-30030 June 2010 Request for Additional Information for Salem Nuclear Generating Station Units 1 and 2 License Renewal Application Regarding Section B.3.1.1 Project stage: RAI ML1017203642010-07-12012 July 2010 Request for Additional Information for Salem Nuclear Generating Station Units 1&2 LRA Regarding ASME Section XI ISI, Subsections Iwb,Iwc, and Iwd (TAC Nos. ME1834/ME1836) Project stage: RAI LR-N10-0231, Notification of Spent Fuel Cask Registration2010-07-13013 July 2010 Notification of Spent Fuel Cask Registration Project stage: Request LR-N10-0243, Response to NRC Request for Additional Information Dated June 14, 2010, Related to Sections 4.3 and 4.4 License Renewal Application2010-07-13013 July 2010 Response to NRC Request for Additional Information Dated June 14, 2010, Related to Sections 4.3 and 4.4 License Renewal Application Project stage: Response to RAI ML1019504872010-07-19019 July 2010 Request for Additional Information for the Salem Generating Station, Unit 1 and Unit 2, License Renewal Application, Section 4.6 Project stage: RAI ML1019606342010-07-23023 July 2010 Request for Additional Information for the Salem Generating Station, Unit 1 and Unit 2, License Renewal Application Project stage: RAI ML1019304962010-07-30030 July 2010 Request for Additional Information for Salem Nuclear Generating Station Units 1 and 2 License Renewal Application (TAC No. ME1834 and Me 1836) Project stage: RAI ML1019704742010-08-0303 August 2010 Request for Additional Information for Salem Nuclear Generating Station Units 1 and 2 License Renewal Application Regarding Bolting Integrity Project stage: RAI ML1019504792010-08-0303 August 2010 Request for Additional Information Regarding ASME Section XI, Subsection IWE for the Salem Nuclear Generating Station Units 1 and 2 License Renewal Application Project stage: RAI ML1015402422010-08-0606 August 2010 Request for Additional Information for Salem Nuclear Generating Station Units 1 and 2 License Renewal Application for Buried Piping Inspection Program Project stage: RAI ML1020004042010-08-0909 August 2010 Request for Additional Information for Salem Nuclear Generating Station Units 1 and 2 License Renewal Application Project stage: RAI LR-N10-0295, Responses to NRC Requests for Additional Information Dated July 12, 2010, July 19, 2010 and July 23, 2010 Related to Various Sections of License Renewal Application2010-08-10010 August 2010 Responses to NRC Requests for Additional Information Dated July 12, 2010, July 19, 2010 and July 23, 2010 Related to Various Sections of License Renewal Application Project stage: Response to RAI ML1020304172010-08-19019 August 2010 RAI Regarding the Salem Nuclear Generating Station Units 1 and 2 License Renewal Application (TAC ME1834 & ME1836) Project stage: RAI ML1022802112010-08-25025 August 2010 Scoping and Screening Audit Summary Regarding the Salem Nuclear Generating Station, Units 1 and 2, License Renewal Application Project stage: Other LR-N10-0313, Responses to Request for Additional Information Dated 08/03/10, Related to Bolting Integrity and 07/30/10 to Steam Generators and Question Posed During Region 1 Inspection, Regarding License Renewal Application2010-08-26026 August 2010 Responses to Request for Additional Information Dated 08/03/10, Related to Bolting Integrity and 07/30/10 to Steam Generators and Question Posed During Region 1 Inspection, Regarding License Renewal Application Project stage: Response to RAI LR-N10-0322, Response to NRC Request for Additional Information, Dated August 6, 2010 Related to the Buried Piping Inspection Program Associated with License Renewal Application2010-09-0707 September 2010 Response to NRC Request for Additional Information, Dated August 6, 2010 Related to the Buried Piping Inspection Program Associated with License Renewal Application Project stage: Response to RAI ML1024600782010-09-29029 September 2010 RAI for Salem Nuclear Generating Station Units 1 and 2 License Renewal Application Project stage: RAI ML1026003402010-10-12012 October 2010 RAI for Salem Nuclear Generating Station Units 1 and 2 License Renewal Application for Buried Piping Inspection Program Project stage: RAI ML1029102492010-10-25025 October 2010 Request for Additional Information for Salem Nuclear Generating Station, Units 1 and 2, License Renewal Application on Structures Monitoring Project stage: RAI ML1029300492010-11-0404 November 2010 Request for Additional Information for Salem Nuclear Generating Station, Units 1 and 2, LRA on Primary Water Stress Corrosion Cracking in Steam Generator Tube-to-Tube Sheet Welds Project stage: RAI ML1031201722010-11-0404 November 2010 Safety Evaluation Report with Open Items Related to the License Renewal of Salem Nuclear Generating Station, Units 1 and 2 Project stage: Approval ML1030101002010-11-0404 November 2010 Safety Evaluation Report Related to the License Renewal of Salem Nuclear Generating Station, Units 1 and 2 Project stage: Approval ML1024305862010-11-0909 November 2010 Audit Report Regarding the Salem Nuclear Generating Station, Units 1 and 2, License Renewal Application Project stage: Other 2010-06-14
[Table View] |
Similar Documents at Salem |
|---|
|
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 August6,2010 Mr. Thomas Joyce President and Chief Nuclear Officer PSEG Nuclear LLC P.O. Box 236 Hancocks Bridge, NJ 08038
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION FOR SALEM NUCLEAR GENERATING STATION UNITS 1 AND 2 LICENSE RENEWAL APPLICATION FOR BURIED PIPING INSPECTION PROGRAM (TAC NOS. ME1834 AND ME1836)
Dear Mr. Joyce:
By letter dated August 18, 2009, Public Service Enterprise Group Nuclear, LLC, submitted an application pursuant to Title 10 of the Code of Federal Regulations Part 54 for renewal of Operating License Nos. DPR-70 and DPR-75 for Salem Nuclear Generating Station Units 1 and 2, respectively. The staff of the U.S. Nuclear Regulatory Commission (NRC or the staff) is reviewing this application in accordance with the guidance in NUREG-1800, "Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants." During its review, the staff has identified areas where additional information is needed to complete the review.
The staff's request for additional information is included in the Enclosure. Further requests for additional information may be issued in the future.
Items in the enclosure were provided to John Hufnagel and other members of your staff, and a mutually agreeable date for the response is within 30 days from the date of this letter. If you have any questions, please contact me by telephone at 301-415-2981 or bye-mail at bennett.brady@nrc.gov.
Sincerely, Bennett M. Brady, Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-272 and 50-311
Enclosure:
As stated cc w/encl: Distribution via Listserv
REQUEST FOR ADDITIONAL INFORMATION FOR SALEM NUCLEAR GENERATING STATION UNITS 1 AND 2 LICENSE RENEWAL APPLICATION FOR BURIED PIPING INSPECTION PROGRAM (TAC NOS. ME1834 AND ME1836)
RAt 6.2.1.22
Background:
The license renewal application (LRA) states that the aging management program (AMP)
B.2.1.22, Buried Piping Inspection Program, is an existing program with one enhancement and is consistent with the program elements in GALL AMP XI.M34. This AMP addresses buried piping (i.e., piping in direct contact with soil). The LRA also states that AMP B.2.1.24, Extemal Surfaces Monitoring Program, is a new program and is consistent with the program elements in GALL AMP XI.M36. This AMP addresses aging management of the external surfaces of piping exposed to air, which would normally include underground inaccessible piping (i.e., piping not in direct contact with soil, but located below grade in a vault, pipe chase, or other structure where it is exposed to air and where access is limited).
There have been a number of recent industry events involving leakage from buried and underground piping and tanks.
Issue:
In light of this recent industry operating experience (OE), the staff is concerned about the continued susceptibility to failure of buried and/or underground piping that are within the scope of 10 CFR 54.4 and subject to aging management for license renewal. In reviewing the AMPs cited above along with the applicable aging management review (AMR) items associated with them, the staff is not clear whether: (1) the components addressed by these AMPs clearly include both buried and underground piping (piping which is below grade and contained in a vault or other structure where it is exposed to air and where access is limited); and (2) whether such programs are being updated to incorporate lessons learned from these recent events as well as any OE from the applicant's own history.
Request:
- 1. Provide a list and a brief summary of any leaks or adverse conditions discovered during inspections (e.g., coating damage that directly exposes the piping or tank to the environment, presence of any coarse material in backfill within six inches of the pipe or tank, unexpected corrosion or damage to piping walls or component pressure boundaries) which have occurred in buried or underground piping or tanks at the station in the past five years that were entered in your corrective action program but are not included in your LRA. Describe how your current AMPs or proposed changes to the AMPs address these issues.
- 2. Provide a discussion of how the AMPs used in managing the aging of buried and underground piping and tanks within the scope of license renewal will address recent industry OE as well as any OE from the applicant's own history.
ENCLOSURE
August 6,2010 Mr. Thomas Joyce President and Chief Nuclear Officer PSEG Nuclear LLC P.O. Box 236 Hancocks Bridge, NJ 08038
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION FOR SALEM NUCLEAR GENERATING STATION UNITS 1 AND 2 LICENSE RENEWAL APPLICATION FOR BURIED PIPING INSPECTION PROGRAM (TAC NOS. ME1834 AND ME1836)
Dear Mr. Joyce:
By letter dated August 18,2009, Public Service Enterprise Group Nuclear, LLC, submitted an application pursuant to Title 10 of the Code of Federal Regulations Part 54 for renewal of Operating License Nos. DPR-70 and DPR-75 for Salem Nuclear Generating Station Units 1 and 2, respectively. The staff of the U.S. Nuclear Regulatory Commission (NRC or the staff) is reviewing this application in accordance with the guidance in NUREG-1800, "Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants." During its review, the staff has identified areas where additional information is needed to complete the review.
The staff's request for additional information is included in the Enclosure. Further requests for additional information may be issued in the future.
Items in the enclosure were provided to John Hufnagel and other members of your staff, and a mutually agreeable date for the response is within 30 days from the date of this letter. If you have any questions, please contact me by telephone at 301-415-2981 or bye-mail at bennett.brady@nrc.gov.
Sincerely, IRA!
Bennett M. Brady, Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-272 and 50-311
Enclosure:
As stated cc w/encl: Distribution via Listserv DISTRIBUTION:
See next page ADAMS Accession No ML101540242 OFFICE PM:DLR:RPB1 LA:DLR BC:DLR:RPB1 PM:DLR:RPB1 NAME B. Brady I. King B. Pham B. Brady DATE 08/05/10 06/04/10 08/06/10 08/06/10 OFFICIAL RECORD COpy
Letter to T. Joyce from B. Brady dated August 6,2010
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION FOR SALEM NUCLEAR GENERATING STATION UNITS 1 AND 2 LICENSE RENEWAL APPLICATION FOR BURIED PIPING INSPECTION PROGRAM (TAC NOS. ME1834 AND ME1836)
DISTRIBUTION:
HARDCOPY:
DLR RF E-MAIL:
PUBLIC RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDlrRarb Resource RidsNrrDlrRasb Resource RidsNrrDlrRapb Resource RidsOgcMailCenter Resource BPham BBrady CEccleston REnnis CSanders BHarris, OGC ABurritt, RI RConte, RI MModes, RI DTifft, RI NMcNamara, RI