Radioactive Effluent Release Report
ML101250335
Person / Time
Site: Braidwood  Constellation icon.png
Issue date: 04/28/2010
From: Shahkarami A
Exelon Generation Co, Exelon Nuclear
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
BW100044
Download: ML101250335 (105)


Text

Exelon Generation Company, LLC www.exeloncorp.com Exekn Nuclear Braidwood Station 35100 South Rt 53, Suite 84 Braceville, I L60407-9619 April 28, 2010 BW100044 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555-0001 Braidwood Station, Units 1 and 2 Facility Operating- License Nos. NPF-72-and- NPF-77 NRC Docket Nos. STN 50-456 and STN 50-457

Subject:

2009 Radioactive Effluent Release Report The attached document includes the Radioactive Effluent Release Report for Braidwood Station. This report is being ,submitted in accordance with 10 CFR 50.36a, "Technical specifications on effluents from nuclear power reactors," and Technical Specification 5.6.3, "Radioactive Effluent Release Report," and includes a summary of radiological liquid and gaseous effluents and solid waste released from the site from January 2009 through December 2009.

If you have any questions regarding this information, please contact Mr. Ron Gaston, Regulatory Assurance Manager, at (815) 417-2800.

Respectfully, Amir~h rm Site Vice President Braidwood Station cc: US NRC Regional Administrator, Region III US NRC Senior Resident Inspector - Braidwood Station NRR Project Manager - Braidwood Station Illinois Emergency Management Agency - Division of Nuclear Safety S4f

RADIOACTIVE EFFLUENT RELEASE REPORT January - December 2009 Facility: BRAIDWOOD NUCLEAR POWER STATION Licensee: EXELON GENERATION COMPANY, LLC

1. Regulatory Limits
a. For Noble Gases:

Dose Rate

1) Less than 500 mrem/year to the whole body.
2) Less than 3000 mrem/year to the skin.

Dose Gamma Radiation

1) Less than or equal to 5 mrad/quarter.
2) Less than or equal to 10 mrad/year.

Dose Beta Radiation

1) Less than or equal to 10 m rad/quarter.
2) Less than or equal to 20 mrad/year.
b. Iodine: (summed with particulate, see below)
c. Particulates with half-lives > 8 days:

Dose Rate

1) Less than 1500 mrem/year to any organ.

Dose

1) Less than or equal to 7.5 mrem/quarter to any organ.
2) Less than or equal to 15 mrem/year to any organ.
d. For Liquid Dose
1) Less than or equal to 1.5 mrem to the whole body during any calendar quarter.
2) Less than or equal to 5 mrem to any organ during any calendar quarter.
3) Less than or equal to 3 mrem to the whole body during any calendar year.
4) Less than or equal to 10 mrem to any organ during any calendar year.

1 of 104

2. Maximum Permissible Concentration
a. Fission and Activation Gases: 10CFR20 Appendix B Table 2
b. Iodine: 10CFR20 Appendix B Table 2
c. Particulates: 10CFR20 Appendix B Table 2
d. Liquid Effluents: 10 X 10CFR20 Appendix B Table 2
3. Average Energy This item is not applicable. Release rates are calculated using an isotopic mix rather than average energy.
4. Measurements and Approximations of Total Radioactivity
a. Fission and Activation Gases, lodines, and Particulates Containment batch releases are analyzed for noble gas and tritium before being discharged by gamma isotopic and scintillation, respectively. Gaseous decay tanks are analyzed for noble gas before being discharged by gamma isotopic. Released activity is normally calculated using volume of release, which is determined by change in tank or containment pressure.

The Auxiliary Building ventilation exhaust system is continually monitored for iodines and particulates. These samples are pulled every 7 days and analyzed by gamma isotopic. The particulate samples are also analyzed quarterly for gross alpha and Sr-89/90.

Noble gas and tritium grab samples are pulled and analyzed weekly by gamma isotopic and scintillation, respectively. The average flow at the release points are used to calculate the curies released.

Volumes and activities of effluents discharged from systems that are common to both units are divided between both units.

The secondary side of both units contain tritium. Very small amounts of tritium are continually released to the atmosphere from secondary components through packing leaks, tank vents, the main condenser, etc. Bounding calculations have been performed to show that very large leaks (1000 gpd) for extended periods (1 month) at normal secondary tritium concentrations, would provide an insignificant increase (1 E-5 mrem) in offsite dose.

No gaseous effluent radiation instrumentation was inoperable beyond the time allowed in the ODCM during 2009.

The calculated offsite dose to the public from station gaseous effluents remains low and a small percentage of the quarterly and annual Offsite Dose Calculation Manual (ODCM) limits.

b. Liquid Effluents The liquid release tanks are analyzed before discharge by gamma isotopic and for tritium. A representative portion of this sample is saved. This is composited, every 31 days, with other discharges that occurred and is analyzed for tritium and gross alpha. The batch composites are composited quarterly and sent to a vendor for Sr-89/90 and Fe-55 analysis. Circulating Water Blowdown, Condensate Polisher Sump and Waste Water Treatment are analyzed weekly by gamma isotopic and for tritium. These weekly samples are composited monthly.

The monthly composites are then composited quarterly and sent to a vendor for Sr-89/90 and Fe-55 analysis.

Tank volumes and activities are used to calculate the curies released for the tanks released.

The total volume of water released and the measured activity is used to calculate the diluted activity released at the discharge point from batch discharges.

2 of 104

4. b. Volumes and activities of effluents discharged from systems that are common to both units are divided between both units.

Due to extreme cold weather, the Exelon Pond composite sampler experienced frozen components and not enough sample was collected for the week of 1/12/09 to 1/19/09 to allow valid analysis. The condition was corrected with the installation of backup sample tubing and the composite sampler provided normal sampling the following week.

On 1/21/09, due to extreme cold weather, the Circulating Water Blowdown composite sampler suction hose was frozen for one day. The condition was corrected with the installation of a backup sample line. The weekly composite sample for 1/19/09 to 1/26/09 did not contain sample for 1/21/09.

On 4/27/09, the Exelon Pond pump composite sampler had no weekly sample. The pond pump was operating during the week and a sample should have been collected. At the time this problem was identified, the pond pump had been shut down and sampler troubleshooting could not be performed. The next time the pump was operated on 4/30/09, troubleshooting revealed that the sample aliquot timer needed adjustment. The timer was adjusted and proper sample collections were restored.

On 7/14/09, the Vacuum Breaker #1 compositor sample isolation valve was identified as not functioning due to build up of iron deposits from the ground water pumped through the system. No sample was being collected. A work request was created and the sample valve was cleaned on 7/15/09. The sample valve function returned to normal and subsequently provided the needed samples.

On 11/23/09, the Exelon Pond composite sampler did not have a sample for the week of 11/16/09 to 11/23/09. A review of the Operations logs revealed that the Exelon Pond pump ran only 73 minutes during the week. Since the Exelon Pond composite sampler only samples every two hours, this short pump run time during this week did not allow enough run time for a valid sample to be collected. The sampler was checked on 11/23/09 and verified functioning properly, and a valid sample was collected the following week.

On 12/7/09, the Exelon Pond composite sampler did not have a valid weekly sample.

Following the discovery of a lack of sample, the composite sampler was checked and was functioning properly. No cause for the missed sample could be determined and a valid sample was collected the following week.

A review of these events indicates four lack of sample events related to Exelon Pond sampling. As issue report has been entered into the station Corrective Action Program to evaluate enhancements to the sample system monitoring and/or maintenance to improve performance.

There were two incidents of liquid effluent radiation instrumentation being inoperable beyond the time allowed in the ODCM during 2009. These event descriptions are located on page 19, item 5.

The calculated offsite dose to the public from station liquid effluents remains low and a small percentage of the quarterly and annual Offsite Dose Calculation Manual (ODCM) limits.

c. Less than the lower limit of detection (<LLD).

Samples are analyzed such that the Offsite Dose Calculation Manual (ODCM) LLD requirements are met. When a nuclide is not detected during the quarter then <LLD is reported.

3 of 104

4. d. Errata for Previous Annual Radioactive Effluent Release Reports The text portion of the 2008 Annual Radioactive Effluent Release Report listed three abnormal gaseous releases. Two of those abnormal releases were Unit Common released and were properly listed in the second quarter of 2008 on the Unit Common Gaseous Effluents Supplemental Release Information. The third abnormal release was a Unit 2 release. This release was inadvertently left out of the Unit 2 Gaseous Effluents Supplemental Release Information table. It should have been listed in the second quarter of the Unit 2 Gaseous Effluents Supplemental Release Information as shown below:

GASEOUS EFFLUENTS SUPPLEMENTAL RELEASE INFORMATION 1st Qtr 2nd Qtr 3rd Qtr 4th Qtr Total B. Abnormal Releases

1. Number of Releases 0 1 0 0 1
2. Total Activity Released (Ci) 0 8.40E+00 0 0 8.40E+00 4 of 104

BRAIDWOOD NUCLEAR POWER STATION ANNUAL EFFLUENT REPORT FOR 2009 GAS RELEASES UNIT 1 (Docket Number 50-456)

SUMMATION OF ALL RELEASES Units 1st QtrI 2nd Qtr 3rd Qtr 4th Qtr Est. Tot Error%

A. Fission and Activation Gas Releases

1. Total Release Activity Ci 8.16E-01 7.89E-01 9.43E-01 2.62E+00 7.59
2. Average Release Rate pCi/sec 1.05E-01 1.00E-01 1.19E-01 3.30E-01
3. Percent of ODCM Limit - gamma  % 5.20E-05 1.58E-04 2.34E-04 5.84E-04
4. Percent of ODCM Limit - beta  % 1.98E-04 3.84E-04 5.67E-04 1.17E-03 B. Iodine Releases
1. Total 1-131 Activity Ci 7.47E-05 3.23E-04 <LLD 1.07E-05 33.20
2. Average Release Rate pCi/sec 9.61 E-06 4.11E-05 0.00E+00 1.35E-06
3. Percent of ODCM Limit - gamma  % 2.31 E-01 9.80E-01 0.OOE+00 1.08E+00 C. Particulate (> 8 day half-life) Releases
1. Gross Activity Ci 3.62E-05 3.46E-06 2.83E-06 5.99E-05 19.80
2. Average Release Rate pCi/sec 4.66E-06 4.45E-07 3.56E-07 7.54E-06
3. Percent of ODCM Limit  % 2.31 E-01 9.80E-01 1.OOE+00 1.08E+00
4. Gross Alpha Activity Ci <LLD <LLD <LLD <LLD D. Tritium Releases
1. Total Release Activity Ci 9.55E+01 9.08E+01 2.12E+01 3.68E+01 8.07
2. Average Release Rate pCi/sec 1.23E+01 1.15E+01 2.67E+00 4.63E+00
3. Percent of ODCM Limit 2.31 E-01 9.80E-01 1.OOE+00 1.08E+00 Note: LLD Values are included in Appendix A of this report.

5 of 104

BRAIDWOOD NUCLEAR POWER STATION ANNUAL EFFLUENT REPORT FOR 2009 GAS RELEASES UNIT 1 (Docket Number 50-456)

CONTINUOUS MODE AND BATCH MODE Nuclides Released Continuous Mode Batch Mode Unit Quarter Quarter Quarter Quarter Quarter Quarter Quarter Quarter 1 2 3 4 1 2 3 4

1. Fission Gases I Ar-41 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD 6.59E-03 Kr-85 Ci <LLD <LLD <LLD <LLD 2.21 E-01 <LLD <LLD <LLD Kr-85m Ci <LLD <LLD <LLD <LLD <LLD 9.52E-04 <LLD 4.40E-03 Kr-87 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Kr-88 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD 2.60E-03 Xe-131m Ci <LLD <LLD <LLD <LLD <LLD <LLD 4.76E-03 <LLD Xe-133 Ci <LLD <LLD <LLD <LLD 5.72E-01 6.52E-01 9.31E-01 2.22E+00 Xe-133m Ci <LLD <LLD <LLD <LLD 1.15E-02 1.48E-02 5.60E-03 5.25E-02 Xe-135 Ci <LLD <LLD <LLD <LLD 1.09E-02 1.22E-01 1.75E-03 3.37E-01 Xe-1 35m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-1 38 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Total for Period Ci <LLD <LLD <LLD <LLD 8.16E-01 7.89E-01 9.43E-01 2.62E+00
2. lodines 1-131 Ci 1.50E-05 8.04E-05 <LLD 3.91E-06 <LLD <LLD <LLD <LLD 1-132 Ci <LLD 2.15E-04 <LLD 4.20E-06 <LLD <LLD <LLD <LLD 1-133 Ci 5.97E-05 2.77E-05 <LLD 2.63E-06 <LLD <LLD <LLD <LLD 1-134 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD 1-135 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Total for Period Ci 7.47E-05 3.23E-04 <LLD 1.07E-05 <LLD <LLD <LLD <LLD
3. Particulates Cr-51 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Mn-54 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Co-57 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Co-58 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Fe-59 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Co-60 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Zn-65 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Br-82 Ci 3.62E-05 <LLD 2.83E-06 5.99E-05 <LLD <LLD <LLD <LLD Sr-89 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Sr-90 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Mo-99 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ag-i 1 Om Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Tc-99m Ci I <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD 6 of 104

BRAIDWOOD NUCLEAR POWER STATION ANNUAL EFFLUENT REPORT FOR 2009 GAS RELEASES UNIT 1 (Docket Number 50-456)

CONTINUOUS MODE AND BATCH MODE Nuclides Released ] Continuous Mode Batch Mode Unit Quarter Quarter Quarter Quarter Quarter Quarter Quarter Quarter 1 2 3 4 1 2 3 4 Sn-1 17m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs-134 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs-137 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ba-140 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD La-140 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-141 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-144 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Nd-147 Ci <LLD 3.46E-06 <LLD <LLD <LLD <LLD <LLD <LLD Te-132 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Sn-1 13 <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Total for Period Ci 3.62E-05 3.46E-06 2.83E-06 5.99E-05 <LLD <LLD <LLD <LLD

4. Tritium Ci 7.80E+01 8.97E+01 2.09E+01 3.16E+01 1.74E+01 1.09E+00 2.43E-01 5.20E+00 7 of 104

BRAIDWOOD NUCLEAR POWER STATION ANNUAL EFFLUENT REPORT FOR 2009 GAS RELEASES UNIT 2 (Docket Number 50-457)

SUMMATION OF ALL RELEASES Units 1st Qtr 2nd Qtr 3rd Qtr 4th Qtr Est.T°oaI A. Fission and Activation Gas Releases

1. Total Activity Released Ci 8.16E-01 7.89E-01 9.72E-01 3.40E+00 7.59
2. Average Release Rate jICi/sec 1.05E-01 1.OOE-01 1.22E-01 4.28E-01
3. Percent of ODCM Limit - gamma  % 5.20E-05 1.58E-04 2.36E-04 6.49E-04
4. Percent of ODCM Limit - beta  % 1.98E-04 3.84E-04 5.72E-04 1.33E-03 B. Iodine Releases
1. Total 1-131 Activity Ci <LLD <LLD 3.68E-05 1.28E-04 33.20
2. Average Release Rate iCi/sec 0.OOE+00 0.00E+00 4.63E-06 1.61 E-05
3. Percent of ODCM Limit  % 0.OOE+00 0.OOE+00 9.26E-02 3.21E-01 C. Particulate (> 8 day half-life) Releases
1. Gross Activity Ci 1.29E-05 <LLD 8.20E-06 4.33E-07 19.80
2. Average Release Rate pCi/sec 1.66E-06 0.OOE+00 1.03E-06 5.45E-08
3. Percent of OCDM Limit  % 1.62E-02 0.OOE+00 9.26E-02 3.21E-01
4. Gross Alpha Activity Ci <LLD <LLD <LLD <LLD D. Tritium Releases
1. Total Release Activity Ci 1.14E+01 2.97E+01 1.66E+01 2.98E+01 8.07
2. Average Release Rate pCi/sec 1.47E+00 3.78E+00 2.09E+00 3.75E+00 4-
3. Percent of ODCM Limit 1.62E-02 5.83E-02 9.26E-02 3.21 E-01 Note: LLD Values are included in Appendix A of this report.

8 of 104

BRAIDWOOD NUCLEAR POWER STATION ANNUAL EFFLUENT REPORT FOR 2009 GAS RELEASES UNIT 2 (Docket Number 50-457)

CONTINUOUS MODE AND BATCH MODE Nuclides Released ] Continuous Mode -_ _- Batch Mode Unit Quarter Quarter Quarter Quarter Quarter Quarter Quarter Quarter 1 2 3 4 1 2 3 4

1. Fission Gases Ar-41 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD 6.59E-03 Kr-85 Ci <LLD <LLD <LLD <LLD 2.21 E-01 <LLD <LLD <LLD Kr-85m Ci <LLD <LLD <LLD <LLD <LLD 9.52E-04 <LLD 4.40E-03 Kr-87 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Kr-88 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD 2.60E-03 Xe-131m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-1 33 Ci <LLD <LLD <LLD <LLD 5.72E-01 6.52E-01 9.60E-01 3.OOE+00 Xe-133m Ci <LLD <LLD <LLD <LLD 1.15E-02 1.48E-02 5.60E-03 5.25E-02 Xe-1 35 Ci <LLD <LLD <LLD <LLD 1.09E-02 1.22E-01 1.75E-03 3.37E-01 Xe-135m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-1 38 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Total for Period Ci <LLD <LLD <LLD <LLD 8.16E-01 7.89E-01 9.72E-01 3.40E+00
2. lodines 1-131 Ci <LLD <LLD 2.71E-06 2.46E-05 <LLD <LLD <LLD <LLD 1-132 Ci <LLD <LLD <LLD 8.38E-05 <LLD <LLD <LLD <LLD 1-133 Ci <LLD <LLD 3.41E-05 1.99E-05 <LLD <LLD <LLD <LLD 1-134 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD 1-135 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Total for Period Ci <LLD <LLD 3.68E-05 1.28E-04 <LLD <LLD <LLD <LLD
3. Particulates Cr-51 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Mn-54 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Co-57 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Co-58 Ci <LLD <LLD 7.20E-06 <LLD <LLD <LLD <LLD <LLD Fe-59 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Co-60 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Zn-65 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Br-82 Ci 1.29E-05 <LLD <LLD <LLD <LLD <LLD <LLD <LLD Sr-89 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Sr-90 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Mo-99 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ag-11 Om Ci <LLD <LLD 9.99E-07 <LLD <LLD <LLD <LLD <LLD Tc-99m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD 9 of 104

BRAIDWOOD NUCLEAR POWER STATION ANNUAL EFFLUENT REPORT FOR 2009 GAS RELEASES UNIT 2 (Docket Number 50-457)

CONTINUOUS MODE AND BATCH MODE Nuclides Released j-Continuous Mode Batch Mode Unit Quarter Quarter Quarter Quarter Quarter Quarter Quarter Quarter 1 2 3 4 1 2 3 4 Sn-117m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs-1 34 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs-1 37 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ba-140 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD La-140 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-141 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-144 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Nd-147 Ci <LLD <LLD <LLD 4.33E-07 <LLD <LLD <LLD <LLD Te-132 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Sn-113 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Total for Period Ci 1.29E-05 <LLD 8.20E-06 4.33E-07 <LLD <LLD <LLD <LLD

4. Tritium Ci 8.70E+00 2.90E+01 1.64E+01 2.64E+01 2.70E+00 6.55E-01 2.80E-01 3.38E+00 10 of 104

BRAIDWOOD NUCLEAR POWER STATION ANNUAL EFFLUENT REPORT FOR 2009 LIQUID RELEASES UNIT 1 (Docket Number 50-456)

SUMMATION OF ALL RELEASES Units 1st Qtr 2nd Qtr 3rd Qtr h Qtr Est. Total I~4t r Error%I A. Fission and Activation Products

1. Total Activity Released Ci 2.62E-03 2.56E-02 7.73E-02 3.05E-02 2.64
2. Average Concentration Released [4Ci/mI 4.45E-10 8.61 E-09 1.78E-08 6.86E-09
3. Percent of limit  % ....

B. Tritium

1. Total Activity Released Ci 8.42E+01 11.48E+02 11.03E+02 11.94E+02 5.85
2. Average Concentration Released 4Ci/mI 1.43E-05 4.98E-05 2.38E-05 4.36E-05
3. % of Limit (1E-2 ýLCi/ml)  % 1.43E-01 4.98E-01 2.38E-01 4.36E-01 C. Dissolved Noble Gases
1. Total Activity Released Ci <LLD <LLD <LLD 7.15E-06 2.64
2. Average Concentration Released iCi/ml 0.00E+00 0.00E+00 0.00E+00 1.61E-12
3. % of Limit (2E-4 1Ci/ml)  % 0.OOE+00 0.00E+00 0.OOE+00 8.04E-07 D. Gross Alpha
1. Total Activity Released Ci 2.17E-05 2.94E-05 2.29E-05 9.70E-05 14.70 12._AverageConcentrationReleased I I.Ci/mI 13.69E-12 J 9.89E-12 15.28E-12 I 2.18E-11I E. Volume of Releases I1.Volume of Liquid Waste to Discharge I liters 11.51 E+05 13.81 E+05 11.73E+05 I 4.39E+05 I
2. Volume of Dilution Water liters 5.89E+09 2.97E+09 4.33E+09 4.45E+09 Note: LLD Values are included in Appendix A of this report.

Note: % Limit Values are included in Appendix B of this report.

  • This limit is equal to 10 times the concentration values in Appendix B, Table 2, Column 2 to 10CFR20.1001-20.2402.

11 of 104

BRAIDWOOD NUCLEAR POWER STATION ANNUAL EFFLUENT REPORT FOR 2009 LIQUID RELEASES UNIT 1 (Docket Numbers 50-456)

CONTINUOUS MODE & BATCH MODE Nuclides Released [ Continuous Mode Batch Mode Unit Quarter Quarter Quarter Quarter Quarter Quarter Quarter Quarter 1 2 3 4 1 2 3 4 H-3 Ci 2.72E+01 2.94E+01 2.60E+01 3.32E+01 5.70E+01 1.18E+02 7.65E+01 1.61E+02 Gross Alpha Ci <LLD <LLD <LLD <LLD 2.17E-05 2.94E-05 2.29E-05 9.70E-05 Ar-41 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cr-51 Ci <LLD <LLD <LLD <LLD <LLD 6.79E-05 <LLD 2.57E-04 Mn-54 Ci <LLD <LLD <LLD <LLD 1.29E-05 6.32E-05 6.73E-04 4.42E-04 Fe-55 Ci <LLD <LLD <LLD <LLD 4.97E-04 9.16E-04 7.94E-04 4.61E-03 Co-57 Ci <LLD <LLD <LLD <LLD <LLD 4.92E-05 3.81 E-04 1.78E-04 Co-58 Ci <LLD <LLD <LLD <LLD 1.59E-04 2.24E-02 6.97E-02 1.76E-02 Fe-59 Ci <LLD <LLD <LLD <LLD <LLD 1.01 E-04 <LLD 1.70E-04 Co-60 Ci <LLD <LLD <LLD <LLD 5.35E-04 1.10E-03 3.68E-03 5.60E-03 Ni-65 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Zn-65 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Kr-85 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Kr-87 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Kr-88 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Sr-89 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Sr-90 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Nb-95 Ci <LLD <LLD <LLD <LLD 6.21 E-06 3.36E-05 1.03E-05 1.77E-04 Zr-95 Ci <LLD <LLD <LLD <LLD <LLD 1.12E-05 <LLD 5.06E-05 Nb-97 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD 2.83E-05 Zr-97 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Tc-99m, Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Mo-99 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ru-103 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ag-110m Ci <LLD <LLD <LLD <LLD <LLD 2.59E-05 <LLD 8.OOE-06 Sn-1 13 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD 5.65E-06 Sn- 117m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Sb-122 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Te-123m Ci <LLD <LLD <LLD <LLD <LLD 2.75E-05 <LLD 8.21 E-05 Sb-124 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Sb-125 Ci <LLD <LLD <LLD <LLD 1.34E-03 7.82E-04 4.07E-04 5.32E-04 Te-125m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD 3.80E-04 Xe-131m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD 1-131 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD 1-132 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Te-132 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD 12 of 104

BRAIDWOOD NUCLEAR POWER STATION ANNUAL EFFLUENT REPORT FOR 2009 LIQUID RELEASES UNIT 1 (Docket Numbers 50-456)

CONTINUOUS MODE & BATCH MODE Nuclides Released Continuous Mode I Batch Mode Unit Quarter Quarter Quarter Quarter Quarter Quarter Quarter Quarter 1 2 3 4 1 2 3 4 Ba-1 33 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD 1-133 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-1 33 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-133m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs-134 Ci <LLD <LLD <LLD <LLD 3.72E-05 1.21E-05 7.67E-04 1.19E-04 Xe-1_35 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD f-134 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD 1-135 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs-1 36 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs-137 Ci <LLD <LLD <LLD <LLD 3.37E-05 1.04E-05 8.81 E-04 1.46E-04 Cs-138 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-138 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ba-139 Ci <LLD <LLD <LLD <LLD <LLD 1.73E-05 <LLD <LLD Ba-_140 CCi <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD La-140 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-1 41 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-144 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Np-239 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Total for period Ci 2.72E+01 2.94E+01 2.60E+01 3.32E+01 5.70E+01 1.18E+02 7.66E+01 1.61E+02 13 of 104

BRAIDWOOD NUCLEAR POWER STATION ANNUAL EFFLUENT REPORT FOR 2009 LIQUID RELEASES UNIT 2 (Docket Number 50-457)

SUMMATION OF ALL RELEASES Un I 1st Qtr 2nd Qtr 3rd Qtr 4th Qtr Est. Total UI tsII Error % I A. Fission and Activation Products

1. Total Activity Released Ci 2.62E-03 2.56E-02 7.73E-02 3.05E-02 2.64
2. Average Concentration Released 4iCi/mI 4.45E-1 0 8.61 E-09 1.78E-08 6.86E-09
3. Percent of Limit  % ....

B. Tritium

1. Total Activity Released Ci 8.42E+01 [1.48E+02 11.03E+02 11.94E+02 5.85
2. Average Concentration Released itCi/ml 1.43E-05 4.98E-05 2.38E-05 I 4.36E-05
3. % of Limit (1 E-3 gCi/ml)  % 1.43E-01 [4.98E-01 2.38E-01 I 4.36E-01 C. Dissolved Noble Gases
1. Total Activity Released Ci <LLD <LLD <LLD 7.15E-06 2.64
2. Average Concentration Released pCi/mI 0.OOE+00 0.OOE+00 0.OOE+00 1.61E-12
3. % of Limit (2E-4 gCi/ml)  % 0.OOE+00 0.OOE+00 0.OOE+00 8.04E-07 D. Gross Alpha
11. Total Activity Released Ci 2.17E-05 2.94E-05 2.29E-05 9.70E-05 14.70
2. Averacge Concentration Released aCi/mI 3.69E-12 I 9.89E-12 15.28E-12 2.18E-11 E. Volume of Releases I1.Volume of Liquid Waste to Discharge I liters 11.51 E+05 13.81 E+05 11.73E+05 I4.39E+050
2. Volume of Dilution Water liters 5.89E+09 2.97E+09 4.33E+09 4.45E+09 Note: LLD Values are included in Appendix A of this report.

Note: % Limit Values are included in Appendix B of this report.

  • This limit is equal to 10 times the concentration values in Appendix B, Table 2, Column 2 to 10CFR20.1001-2402.

14 of 104

BRAIDWOOD NUCLEAR POWER STATION ANNUAL EFFLUENT REPORT FOR 2009 LIQUID RELEASES UNIT 2 (Docket Numbers 50-457)

CONTINUOUS MODE & BATCH MODE Nuclides Released Continuous Mode Batch Mode Unit Quarter Quarter Quarter Quarter Quarter Quarter Quarter Quarter 1 2 3 4 1 2 3 4 H-3 Ci 2.72E+01 2.94E+01 2.60E+01 3.32E+01 5.70E+01 1.18E+02 7.65E+01 1.61E+02 Gross Alpha Ci <LLD <LLD <LLD <LLD 2.17E-05 2.94E-05 2.29E-05 9.70E-05 Ar-41 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cr-51 Ci <LLD <LLD <LLD <LLD <LLD 6.79E-05 <LLD 2.57E-04 Mn-54 Ci <LLD <LLD <LLD <LLD 1.29E-05 6.32E-05 6.73E-04 4.42E-04 Fe-55 Ci <LLD <LLD <LLD <LLD 4.97E-04 9.16E-04 7.94E-04 4.61E-03 Co-57 Ci <LLD <LLD <LLD <LLD <LLD 4.92E-05 3.81E-04 1.78E-04 Co-58 Ci <LLD <LLD <LLD <LLD 1.59E-04 2.24E-02 6.97E-02 1,76E-02 Fe-59 Ci <LLD <LLD <LLD <LLD <LLD 1.01 E-04 <LLD 1.70E-04 Co-60 Ci <LLD <LLD <LLD <LLD 5.35E-04 1.10E-03 3.68E-03 5.60E-03 Ni-65 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Zn-65 Ci <LLD <LLD .<LLD <LLD <LLD <LLD <LLD <LLD Kr-85 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Kr-87 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Kr-88 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Sr-89 Ci <LLD <LLD <LLD <LLD <LLD. <LLD <LLD <LLD Sr-90 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Nb-95 Ci <LLD <LLD <LLD <LLD 6.21E-06 3.36E-05 1.03E-05 1.77E-04 Zr-95 Ci <LLD <LLD <LLD <LLD <LLD 1.12E-05 <LLD 5.06E-05 Nb-97 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD 2.83E-05 Zr-97 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Tc-99m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Mo-99 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ru-1 03 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ag-110m Ci <LLD <LLD <LLD <LLD <LLD 2.59E-05 <LLD 8.OOE-06 Sn-113 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD 5.65E-06 Sn-117m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Sb-122 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Te-123m Ci <LLD <LLD <LLD <LLD <LLD 2.75E-05 <LLD 8.21 E-05 Sb-124 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Sb-125 Ci <LLD <LLD <LLD <LLD 1.34E-03 7.82E-04 4.07E-04 5.32E-04 Te-125m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD 3.80E-04 Xe-131m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD 1-131 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD 1-132 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Te-132 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD 15 of 104

BRAIDWOOD NUCLEAR POWER STATION ANNUAL EFFLUENT REPORT FOR 2009 LIQUID RELEASES UNIT 2 (Docket Numbers 50-457)

CONTINUOUS MODE & BATCH MODE Nuclides Released - Continuous Mode -[ Batch Mode Unit Quarter Quarter Quarter Quarter Quarter Quarter Quarter Quarter 1 2 3 4 1 2 3 4 Ba-133 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD 1-133 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-1 33 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-133m Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs-134 Ci <LLD <LLD <LLD <LLD 3.72E-05 1.21E-05 7.67E-04 1.19E-04 Xe-1 35 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD 1-134 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD 1-135 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Cs-1 36 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD

,Cs-137 Ci <LLD <LLD <LLD <LLD 3.37E-05 1.04E-05 8.81E-04 1.46E-04 Cs-138 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Xe-138 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ba-139 Ci <LLD <LLD <LLD <LLD <LLD 1.73E-05 <LLD <LLD Ba-140 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD La-140 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-141 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Ce-144 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Np-239 Ci <LLD <LLD <LLD <LLD <LLD <LLD <LLD <LLD Total for period Ci 2.72E+01 2.94E+01 2.60E+01 3.32E+01 5.70E+01 1.18E+02 7.66E+01 1.61E+02 16 of 104

BRAIDWOOD NUCLEAR POWER STATION RADIOACTIVE EFFLUENT RELEASE REPORT FOR 2009 SOLID RADIOACTIVE WASTE UNIT 1 AND 2 COMBINED (Docket Numbers 50-456 and 50-457)

A. Solid Waste Shipped Offsite for Burial or Disposal (Not irradiated fuel)

1. Types of Waste Total Types of Waste Quantity Total Activity Period Est. Total (Ci) Error %

(m3)

a. Spent resins, filter sludges, evaporator bottoms, etc 1.47E+02 4.33E+01 2009 25
b. Dry compressible waste, contaminated equip, etc 2.79E+02 5.64E+00 Jan2009

- Dec 25 Jan - Dec

c. Irradiated components, control rods, etc 0 0 2009 N
d. Other (oil, reverse osmosis reject water, soil, Lagoon 1.19E+02 1.81 E-02 Jan - Dec 25 sediment) 2009
2. Estimate of major nuclide composition (by waste type)

Major Nuclide Composition  %

a. Fe-55 20.71 Cs-1 37 16.66 Cs-134 16.37 Ni-63 13.37 H-3 9.50 Co-58 9.42 Co-60 9.14 Sb-125 2.01 Mn-54 1.66 C-14 0.35 Co-57 0.25 Ni-59 0.17 Zn-65 0.16 17 of 104

BRAIDWOOD NUCLEAR POWER STATION RADIOACTIVE EFFLUENT RELEASE REPORT FOR 2009 SOLID RADIOACTIVE WASTE UNIT 1 AND 2 COMBINED (Docket Numbers 50-456 and 50-457)

2. Estimate of major nuclide composition (by waste type) cont.

Major Nuclide Composition  %

b. Ni-63 35.30 Fe-55 31.97 Co-60 16.80 Co-58 5.58 Cs-137 2.38 H-3 2.00 Cs-134 1.60 C-14 1.29 Mn-54 0.66 Fe-59 0.61 Nb-95 0.46 Sb-125 0.44 Ni-59 0.41 Zr-95 0.25
c. N/A N/A
d. Fe-55 42.60 Ni-63 16.67 Co-60 15.95 Co-58 8.90 H-3 7.01 Cs-1 34 2.48 Mn-54 1.01
3. Solid Waste Disposition Number of Shipments Mode of Transportation Destination 7 TClive Disposal Facility (containerized) -

Hittman Transportation Clive, UT Duratek Services- Bear Creek Facility -

9 Hittman Transportation Oak Ridge, TN Duratek Services - Gallaher Rd. -

7 Hittman Transportation Kingston, TN Duratek Services - Gallaher Rd. -

7 Visionary Solutions, LLCTN B. Irradiated Fuel Shipments (disposition)

No irradiated fuel shipments for January through December, 2009.

C. Changes to the Process Control Program There were no changes to the process control program in 2009.

18 of 104

BRAIDWOOD NUCLEAR POWER STATION RADIOACTIVE EFFLUENT RELEASE REPORT FOR 2009 UNIT 1 AND 2 COMBINED (Docket Numbers 50-456 and 50-457)

1. In 2009, there were no changes to the Process Control Program.
2. In 2009, there were no changes to the station's radioactive waste systems.
3. There were no liquid release tanks or gas decay tanks which exceeded the limits addressed in the ODCM-RETS.
4. There were no abnormal liquid releases in 2009 resulting in offsite discharge.

On 6/30/09, a spill of U2 secondary water containing tritium occurred when a sump overflowed. The water flowed out of the Condensate Polisher Room to the ground and to a storm sewer. The storm sewer water was immediately pumped back to the plant drain system and sampling was initiated at downstream points to ensure that the contaminated water did not leave site.

One abnormal gaseous release occurred in 2009 and is described below.

On July 30, 2009, Unit 2 tripped and steam containing tritium was released to the atmosphere through the steam generator power operated relief valves (PORVs). The plant performed as designed and when these valves opened and intermittently as the plant was cooled down. The steam release continued periodically for approximately 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br /> until normal cooling was restored to the unit. At the time of this release, Unit 2 secondary tritium concentration was 3.86E-5 ýiCi/g. A conservative release permit was performed in the Radioactive Effluent Tracking and Dose Assessment Software (RETDAS). Permit #2010007 was used to calculate offsite dose from the release. The calculated dose was insignificant.

5. The following effluent monitoring instruments exceeded their specified inoperability time.

OF-WX001 (Liquid Radwaste Effluent Line Loop WX001) exceeded its specified inoperability time on 4/24/07. At that time, required surveillances for this effluent instrument were taken to "suspend" and were not performed because this effluent flow path was no longer in use at Braidwood Station. The instrument continues to be inoperable and no liquid releases have taken place through this release path during the time of inoperability. A design change and modification to this flow path are in progress. Required surveillances will be performed prior to this flow path being put back in service.

One liquid effluent radiation instrument was inoperable beyond the time allowed in the ODCM. On 10/26/09, ORE-PROO1, Liquid Radwaste Effluent Line Radiation Monitor, was declared inoperable and entered the 14 day time clock established in the ODCM. Liquid radwaste releases were performed within the 14 days using the guidance established in the ODCM and station Operating procedures. ORE-PRO01 was not declared operable by the end of the 14 day period on 11/8/09, and liquid radwaste releases were suspended until the monitor was declared operable. Work was completed and the monitor was declared operable on 11/10/09.

6. No changes were made to the ODCM in 2009.
7. NUREG-0543, Methods for Demonstrating LWR Compliance with the EPA Uranium Fuel Cycle Standard (40 CFR Part 190) states in section IV, "As long as a nuclear plant site operates at a level below the Appendix I reporting requirements, no extra analysis is required to demonstrate compliance with the 40 CFR Part 190." The organ and whole body doses reported on pages 28 through 47 are determined using 10 CFR 50 Appendix I methodology. The doses are below the limits of Appendix I.

19 of 104

BRAIDWOOD NUCLEAR POWER STATION RADIOACTIVE EFFLUENT RELEASE REPORT FOR 2009 UNIT 1 AND 2 (Docket Numbers 50-456 and 50-457)

APPENDIX A LLD Tables 20 of 104

BRAIDWOOD NUCLEAR POWER STATION RADIOACTIVE EFFLUENT RELEASE REPORT FOR 2009 UNIT 1 AND 2 (Docket Numbers 50-456 and 50-457)

LLD VALUES FOR GASEOUS RELEASES Isotope LLD (Ci/mi)

Alpha 7.11E-19 H-3 8.03E-14 Ar-41 7.63E- 13 Mn-54 1.89E-18 Co-57 1.02E-18 Co-58 5.67E- 19 Fe-59 3.64E- 18 Co-60 8.94E-19 Zn-65 4.80E-18 Br-82 7.44E- 19 Kr-85 5.83E-1 1 Kr-85m 7.03E-13 Kr-87 7.59E-13 Kr-88 3.18E-12 Sr-89 1.41 E-20 Sr-90 2.71 E-21 Mo-99 9.37E-1 9 1-131 8.96E-1 9 1-132 2.38E-1 7 1-133 1.17E-18 Xe-131m 1.82E-11 Xe-133 1.27E-12 Xe-1 33m 4.87E-12 Cs-134 2.25E-18 1-135 2.88E-18 Xe-1 35 5.17E-13 Xe-1 35m 1.48E-11 Cs-137 2.18E-18 Xe-138 4.65E-1 1 Ba-139 1.04E-15 Ba-140 4.45E-18 La-140 3.64E-1 8 Ce-141 1.78E-18 Ce-144 7.93E-1 8 NOTE: LLD Value for total activity released is based on LLD values for individual isotopes used in the calculation.

21 of 104

BRAIDWOOD NUCLEAR POWER STATION RADIOACTIVE EFFLUENT RELEASE REPORT FOR 2009 UNIT 1 AND 2 (Docket Numbers 50-456 and 50-457)

LLD VALUES FOR LIQUID RELEASES Isotope LLD (Ci/ml)

Alpha 4.90E-14 H-3 8.OOE-12 Ar-41 3.73E-14 Cr-51 4.46E- 13 Mn-54 1.56E-14 Fe-55 6.99E-13 Co-57 4.64E-14 Co-58 4.39E-14 Fe-59 3.94E-14 Co-60 9.40E-14 Zn-65 4.04E-14 Sr-89 4.OOE-1 4 Sr-90 9.23E-1 5 Nb-95 1.64E-14 Zr-95 1.22E-13 Nb-97 1.51E-13 Mo-99 2.94E- 13 Tc-99m 3.OOE-1 3 Ag-110m 7.89E- 14 Sb-124 5.43E-14 Sb-125 1.87E-13 Te-1 25m 1.62E-11 1-131 1.36E-13 Xe-133 1.41E-13 Cs-134 5.02E- 14 Cs-137 6.50E- 14 Ba-1 39 3.57E-1 3 Ba- 140 1.50E-13 La-1 40 5.89E-1 3 Ce-141 9.35E-14 Ce- 144 3.48E-13 Kr-85 9.29E- 12 Nb-95 1.64E-14 Sb-122 4.32E-13 Te-123m 4.92E- 14 Te-132 2.28E-13 1-132 5.93E-14 1-133 2.37E-1 1 Cs-136 9.72E- 14 Xe-1 33m 3.81 E-13 Xe-131m 1.72E-12 Np-239 1.64E-12 Ba-133 6.31 E-14 Xe-135 2.43E-1 3 NOTE: LLD Value for Total Activity Released is based on LLD Values for individual isotopes used in the calculation.

22 of 104

BRAIDWOOD NUCLEAR POWER STATION RADIOACTIVE EFFLUENT RELEASE REPORT FOR 2009 UNIT 1 AND 2 (Docket Numbers 50-456 and 50-457)

APPENDIX B Supplemental Information 23 of 104

BRAIDWOOD NUCLEAR POWER STATION RADIOACTIVE EFFLUENT RELEASE REPORT FOR 2009 UNIT COMMON GASEOUS EFFLUENTS SUPPLEMENTAL RELEASE INFORMATION A. Batch Release 1st Qtr 2nd Qtr 3rd Qtr 4th Qtr Total

1. Total Number of Batch 7 8 9 16 40 Releases
2. Total Time Period for Batch 1,270 2,501 2,072 3,122 8,965 Releases (minutes)
3. Maximum Time Period for a 391 621 912 1,530 N/A Batch Release (minutes)
4. Average Time Period for a 181 313 230 195 N/A Batch Release (minutes)
5. Minimum Time Period for a 4 150 69 7 N/A Batch Release (minutes)

B. Abnormal Releases

1. Number of Releases 0 0 0 0 0
2. Total Activity Released (Ci) 0 0 0 0 0 24 of 104

BRAIDWOOD NUCLEAR POWER STATION RADIOACTIVE EFFLUENT RELEASE REPORT FOR 2009 UNIT 1 (Docket Number 50-456)

GASEOUS EFFLUENTS SUPPLEMENTAL RELEASE INFORMATION A. Batch Release 1st Qtr 2nd Qtr 3rd Qtr 4th Qtr Total

1. Total Number of Batch 51 21 18 20 110 Releases
2. Total Time Period for Batch 34,942 11,812 1,041 9,875 57,670 Releases (minutes)
3. Maximum Time Period for 1,920 6,570 491 2,150 N/A a Batch Release (minutes)
4. Average Time Period for a Batch Release (minutes) 685 562 58 494 N/A
5. Minimum Time Period for a Batch Release (minutes) 10 17 16 35 N/A B. Abnormal Releases
1. Number of Releases 0 0 0 0 0
2. Total Activity Released (Ci) 0 0 0 0 0 25 of 104

BRAIDWOOD NUCLEAR POWER STATION RADIOACTIVE EFFLUENT RELEASE REPORT FOR 2009 UNIT 2 (Docket Number 50-457)

GASEOUS EFFLUENTS SUPPLEMENTAL RELEASE INFORMATION A. Batch Release 1st Qtr 22nd Qtr 3rd Qtr 4th Qtr Total

1. Total Number of Batch 22 19 20 23 84 Releases
2. Total Time Period for 3,649 4,291 931 14,983 23,854 Batch Releases (minutes)
3. Maximum Time Period for 1,660 3,590 304 3,920 N/A a Batch Release (minutes)
4. Average Time Period for a 166 226 47 651 N/A Batch Release (minutes)
5. Minimum Time Period for 11 19 16 13 N/A a Batch Release (minutes)

B. Abnormal Releases

1. Number of Releases 0 0 1 0 1
2. Total Activity Released (Ci) 0 0 1.37E-02 0 1.37E-02 26 of 104

BRAIDWOOD NUCLEAR POWER STATION RADIOACTIVE EFFLUENT RELEASE REPORT FOR 2009 UNIT 1 AND 2 COMBINED (Docket Numbers 50-456 and 50-457)

BRAIDWOOD NUCLEAR POWER STATION LIQUID EFFLUENTS SUPPLEMENTAL RELEASE INFORMATION A. Batch Release 1st Qtr 2nd Qtr 3rd Qtr 4th Qtr Total

1. Total Number of Batch Releases 8 21 11 26 66
2. Total Time Period for Batch 1,898 4,777 2,421 6,076 15,172 Releases (minutes)
3. Maximum Time Period for a 268 267 237 310 N/A Batch Release (minutes)
4. Average Time Period for a 237 227 220 234 N/A Batch Release
5. Minimum Time Period for a Batch Release (minutes) .

205 39 201 7 N/A

6. Average Stream Flow During Periods of Release of Effluent 2.20E+07 1.32E+07 2.63E+06 1.05E+07 N/A into a Flowing Stream (liters/min)

B. Abnormal Releases

1. Number of Releases 0 0 0 0 0
2. Total Activity Released (Ci) 0.00+00 0.00+00 0.00+00 0.OOE+00 0.OOE+00 27 of 104

RETDAS v3.6.3 <BRA> VSSI GASEOUS RELEASE AND DOSE

SUMMARY

REPORT - BY UNIT (Composite Critical Receptor - Limited Analysis)

Release ID ............. 1 All Gas Release Types Period Start Date ....  :.01/01/2009 00:00 Period End Date ......  :.01/01/2010 00:00 Period Duration (min): 5.256E+05 Coefficient Type ..... :.Historical Unit ..................... 1 RELEASE DATA Total Release Duration (minutes) ...................................... 3.549E+05 Total Release Volume (cf) ......................................... .... 4.568E+10 Average Release Flowrate (cfm) ........................................ 1.287E+05 Average Period Flowrate (cfm) 8. 691E+04

==NUCLIDE DATA Average ECrcent Nuclide uCi uCi/cc Ratio EC AR-41 6. 59E+03 5.10E-12 5. 10E-04 1. OOE-08 KR-85M 5 35E+03 4.14E-12 4. 14E-05 1. OOE-07 KR-85 2 .21E+05 1.71E-10 2. 44E-04 7. OOE-07 XE-133M 8. 44E+04 6.53E-11 1. 09E-04 6. OOE-07 KR-88 2 . 60E+03 2.01E-12 2 .23E-04 9. OOE-09 XE-131M 4. 76E+03 3.68E-12 1. 84E-06 2 .OOE-06 XE-135 4. 72E+05 3.65E-10 5. 21E-03 7. OOE-08 XE-133 4. 37E+06 3.38E-09 6.76E-03 5 .OOE-07 F&AG 5 . 17E+06 4.OOE-09 1.31E-02 1-131 9. 93E+01 7.68E-14 3.84E-04 2. OOE-10 1-132 2. 19E+02 1.69E-13 8.46E-06 2. OOE-08 1-133 9. 01E+01 6.96E-14 6.96E-05 1. OOE-09 Iodine 4. 08E+02 3 .16E-13 4. 62E-04 BR- 82 9. 89E+01 7 .65E-14 1. 53E-05 5. OOE-09 Other 9. 89E+01 7. 65E-14 1. 53E-05 H-3 2 .44E+08 1. 89E-07 1. 89E+00 1. OOE-07 H-3 2. 44E+08 1. 89E-07 1. 89E+00 ND-147 3 .46E+00 2. 68E-15 2 .68E-06 1. OOE-09 P>=8 3 . 46E+00 2. 68E-15 2. 68E-06 Date/Time: 04/07/2010 16:19 brwmn ID: Retdas Page - 1 28 of 104

RETDAS v3.6.3 <BRA> VSSI GASEOUS RELEASE AND DOSE

SUMMARY

REPORT - BY UNIT (Composite Critical Receptor - Limited Analysis)

Release ID ............ 1 All Gas Release Types Period Start Date .... 01/01/2009 00:00 Period End Date ...... 01/01/2010 00:00 Period Duration (min): 5.256E+05 Coefficient Type ..... Historical Unit ..................

NUCLIDE DATA Average ECrcent Nuclide uCi uCi/cc Ratio EC Total 2.49E+08 1.93E-07 1.90E+00 Date/Time: 04/07/2010 16:19 brwmn ID: Retdas Page - 2 29 of 104

RETDAS v3.6.3 <BRA> VSSI GASEOUS RELEASE AND DOSE

SUMMARY

REPORT - BY UNIT (Composite Critical Receptor - Limited Analysis)

Release ID ............. 1 All Gas Release Types Period Start Date .... 01/01/2009 00:00 Period End Date ......  :.01/01/2010 00:00 Period Duration (min): 5.256E+05 Coefficient Type ..... :.Historical Unit ..................  : 1 Receptor ............... 5 Composite Crit. Receptor - IP Distance (meters) .... 0.0 Compass Point .......... 0.0 PERIOD DOSE BY AGEGROUP, PATHWAY, ORGAN (mrem)

Age/Path Bone Liver Thyroid Kidney Lung GI-Lli Skin TB AGPD 1.16E-06 1.16E-06 1.16E-06 1.16E-06 1.16E-06 1. 16E-06 0. OOE+00 1.16E-06 AINHL 1.31E-07 6. 46E-03 6. 51E-03 6. 46E-03 6. 46E-03 6. 46E-03 0. OOE+00 6. 46E-03 AVEG 4. 27E-06 1. 16E-02 1. 36E-02 1.16E-02 1.16E-02 1. 16E-02 0. OOE+00 1.16E-02 AGMILK 1. 86E-05 8. 01E-03 1. 66E-02 8. 03E-03 7.98E-03 7. 99E-03 0. OOE+00 8. OOE-03 ACMEAT 5. 55E-07 1. 67E-03 1. 93E-03 1. 67E-03 1.67E-03 1. 67E-03 0. OOE+00 1. 67E-03 ACMILK 1.55E-05 3 . 93E-03 1.l1E-02 3. 95E-03 3. 91E-03 3. 92E-03 0. OOE+00 3. 92E-03 TGPD 1.16E-06 1. 16E-06 1.16E-06 1.16E-06 1.16E-06 1. 16E-06 0. OOE+00 1.16E-06 TINHL 1.84E-07 6. 52E-03 6.58E-03 6. 52E-03 6. 52E-03 6. 52E-03 0. OOE+00 6. 52E-03 TVEG 4. 06E-06 1.33E-02 1.49E-02 1. 33E-02 1.33E-02 1. 33E-02 0. OOE+00 1.33E-02 TGMILK 3.37E-05 1.04E-02 2.41E-02 1. 05E-02 1.04E-02 1. 04E-02 0. OOE+00 1. 04E-02 TCMEAT 4. 61E-07 9. 93E-04 1.18E-03 9. 94E-04 9.92E-04 9. 93E-04 0. OOE+00 9.93E-04 TCMILK 2.81E-05 5. 13E-03 1. 65E-02 5. 16E-03 5. 09E-03 5 OE-03 0 OOE+00 5. 11E-03 CGPD 1.16E-06 1. 16E-06 1.16E-06 1. 16E-06 1.16E-06 1.16E-06 0 OOE+00 1. 16E-06 CINHL 2.49E-07 5.75E-03 5. 83E-03 5. 75E-03 5. 75E-03 5. 75E-03 0. OOE+00 5.75E-03 CVEG 7. 56E-06 2.06E-02 2 .31E-02 2. 06E-02 2. 06E-02 2.06E-02 0. OOE+00 2. 06E-02 CGMILK 8. 18E-05 1.65E-02 4 .36E-02 1. 66E-02 1. 65E-02 1. 65E-02 0. OOE+00 1. 65E-02 CCMEAT 8. 56E-07 1.20E-03 1. 49E-03 1.20E-03 1.20E-03 1.20E-03 0. OOE+00 1.20E-03 CCMILK 6. 82E-05 8. 13E-03 3. 07E-02 8. 18E-03 8. 07E-03 8. 07E-03 0. OOE+00 8. lOE-03 IGPD 1. 16E-06 1.16E-06 1. 16E-06 1. 16E-06 1. 16E-06 1. 16E-06 0. OOE+00 1. 16E-06 IINHL 1.97E-07 3. 31E-03 3 .38E-03 3. 31E-03 3.31E-03 3.31E-03 0. OOE+00 3. 31E-03 IGMILK 1.71E-04 2. 52E-02 9 . 08E-02 2 . 52E-02 2.50E-02 2 . 50E-02 0. OOE+00 2. 51E-02 ICMILK 1.42E-04 1.24E-02 6. 72E-02 1. 24E-02 1.22E-02 1.22E-02 0. OOE+00 1. 23E-02 PERIOD DOSE BY AGEGROUP, ORGAN (mrem)

Agegroup Bone Liver Thyroid Kidney Lung GI-Lli Skin TB ADULT 4.02E-05 3.17E-02 4.98E-02 3.17E-02 3.16E-02 3.16E-02 0.OOE+00 3.16E-02 TEEN 6.77E-05 3.63E-02 6.33E-02 3.64E-02 3.62E-02 3.63E-02 0.OOE+00 3.63E-02 CHILD 1.60E-04 5.22E-02 1.05E-01 5.23E-02 5.21E-02 5.21E-02 0.OOE+00 5.21E-02 INFANT 3.15E-04 4.09E-02 1.61E-01 4.09E-02 4.05E-02 4.05E-02 0.OOE+00 4.07E-02 Date/Time: 04/07/2010 16:19 brwmn ID: Retdas Page - 3 30 of 104

RETDAS v3.6.3 <BRA> VSSI GASEOUS RELEASE AND DOSE

SUMMARY

REPORT - BY UNIT (Composite Critical Receptor - Limited Analysis)

Release ID ........... 1 All Gas Release Types Period Start Date .... 01/01/2009 00:00 Period End Date ...... 01/01/2010 00:00 Period Duration (min) '5.256E+05 Coefficient Type ..... Historical Unit ................. :1 Receptor ............. 5 Composite Crit. Receptor - IP Distance (meters) .... 0.0 Compass Point ........ 0.0

=== MAXIMUM PERIOD DOSE TO LIMIT (Any Organ)

Dose Age Dose Limit Admin Admin % T.Spec T.Spec %

Period Group Organ (mrem) Period Limit of Limit Limit of Limit Strt->End INFANT THYROID 1.61E-01 31-day 2.25E-01 7.17E+01 3.OOE-01 5.38E+01 Qrtr->End INFANT THYROID 1.61E-01 Quarter 5.63E+00 2.87E+00 7.50E+00 2.15E+00 Year->End INFANT THYROID 1.61E-01 Annual 1.13E+01 1.43E+00 1.50E+01 1.08E+00 Critical Pathway ........  :.3 Grs/Goat/Milk (GMILK)

Major Contributors ......  :.0.0 % or greater to total Nuclide Percentage H-3 2.51E+01 1-131 7.44E+01 1-132 9.36E-04 1-133 6.20E-01 ND-147 9.48E-06 MAXIMUM PERIOD DOSE TO LIMIT (Tot Body))

Dose Age Dose Limit Admin Admin  % T. Spec T.Spec %

Period Group Organ (mrem) Period Limit of Limit Limit of Limit Strt->End CHILD TBODY 5.21E-02 31-day 1. 50E-01 3.48E+01 2. OOE-01 2.61E+01 Qrtr->End CHILD TBODY 5 .21E-02 Quarter 5.25E+00 9. 93E-01 7 .50E+00 6.95E-01 Year->End CHILD TBODY 5.21E-02 Annual 1. 05E+01 4. 97E-01 1. SOE+01 3.48E-01 Critical Pathway ........ 2 Vegetation (VEG)

Major Contributors ....... 0.0  % or greater to total Nuclide Percentage H-3 , 9.99E+01 1-131 1.73E-01 1-132 3.01E-04 1-133 2.01E-03 ND-147 2.95E-05 Date/Time: 04/07/2010 16:19 brwmn ID: Retdas Page - 4 31 of 104

RETDAS v3.6.3 <BRA> VSSI GASEOUS RELEASE AND DOSE

SUMMARY

REPORT - BY UNIT (Composite Critical Receptor - Limited Analysis)

Release ID ............. 1 All Gas Release Types Period Start Date ....  :.01/01/2009 00:00 Period End Date ......  :.01/01/2010 00:00 Period Duration (min): 5.256E+05 Coefficient Type ..... :.Historical Unit ..................... 1 Receptor ..............  : 4 Composite Crit. Receptor - NG Distance (meters) ....  :.0.0 Compass Point .......... 0.0 MAXIMUM PERIOD NG DOSE TO LIMIT (Gamma)

Dose Dose Limit Admin Admin  % T.Spec T.Spec %

Period Dose Type (mrad) Period Limit of Limit Limit of Limit Strt->End Gamma 5.84E-05 Qrtr->End Gamma 5.84E-05 31-day 1.50E-01 3.90E-02 2.OOE-01 2.92E-02 Year->End Gamma 5.84E-05 Quarter 3.75E+00 1.56E-03 5.OOE+00 1.17E-03 Annual 7.50E+00 7.79E-04 1.00E+01 5.84E-04 Major Contributors ......  :.0.0  % or greater to total Nuclide Percentage AR-41 2.37E+00 KR-85M 2.54E-01 KR-85 1.47E-01 XE-133M 1.07E+00 KR-88 1.52E+00 XE-131M 2.87E-02 XE-135 3.50E+01 XE-133 5.96E+01 MAXIMUM PERIOD NG DOSE TO LIMIT (Beta))

Dose Dose Limit Admin Admin % T.Spec T.Spec %

Period Dose Type (mrad) Period Limit of Limit Limit of Limit Strt->End Beta 2.34E-04 Qrtr->End Beta 2.34E-04 31-day 3.OOE-01 7.80E-02 4.OOE-01 5.85E-02 Year->End Beta 2.34E-04 Quarter 7.50E+00 3.12E-03 1.00E+01 2.34E-03 Annual 1.50E+01 1.56E-03 2.OOE+01 1.17E-03 Major Contributors ...... .. 0.0 % or greater to total Nuclide Percentage AR-41 3.40E-01 KR-85M 1.66E-01 KR-85 6.79E+00 XE-133M 1.97E+00 KR-88 1.20E-01 XE-131M 8.31E-02 XE-135 1.83E+01 XE-133 7.23E+01 Date/Time: 04/07/2010 16:19 brwmn ID: Retdas LAST Page - 5 32 of 104

RETDAS v3.6.3 <BRA> VSSI GASEOUS RELEASE AND DOSE

SUMMARY

REPORT - BY UNIT (Composite Critical Receptor - Limited Analysis)

Release ID ............. 1 All Gas Release Types Period Start Date ....  :.01/01/2009 00:00 Period End Date ...... .. 01/01/2010 00:00 Period Duration (min): 5.256E+05 Coefficient Type ..... :.Historical Unit ..................... 2 RELEASE DATA Total Release Duration (minutes) ...................................... 3.271E+05 Total Release Volume (cf) ............................................. 3.158E+10 Average Release Flowrate (cfm) ........................................ 9.653E+04 Average Period Flowrate (cfm) ......................................... 6.008E+04 NUCLIDE DATA Average ECrcent Nuclide uCi uCi/cc Ratio EC AR-41 6. 59E+03 7.37E-12 7.37E-04 1. OOE-08 KR-85M 5.35E+03 5.99E-12 5.99E-05 1.OOE-07 KR-85 2.21E+05 2.47E-10 3.54E-04 7. OOE-07 XE-133M 8. 44E+04 9.44E-11 1.57E-04 6. OOE-07 KR-88 2. 60E+03 2.90E-12 3.23E-04 9. OOE-09 XE-131M 4.76E+03 5.32E-12 2.66E-06 2 . OOE-06 XE-135 4.72E+05 5.28E-10 7.54E-03 7. OOE-08 XE-133 5. 18E+06 5.79E-09 1.16E-02 5. OOE-07 F&AG 5. 98E+06 6.69E-09 2.08E-02 1-131 2 . 73E+01 3.06E-14 1.53E-04 2. OOE-10 1-132 8.38E+01 9.37E-14 4.68E-06 2 . OOE-08 1-133 5. 40E+01 6.04E-14 6.04E-05 1. OOE-09 Iodine 1. 65E+02 1.85E-13 2.18E-04 BR-82 1.29E+01 1.44E-14 2.89E-06 5 . OOE-09 Other 1.29E+01 1.44E-14 2.89E-06 H-3 8. 75E+07 9.78E-08 9.78E-01 1. OOE-07 H-3 8. 75E+07 9.78E-08 9.78E-01 CO-58 7.20E+00 8.06E-15 8.06E-06 1. 0OE-09 AG-11OM 9. 99E-01 1.12E-15 1.12E-05 1.OOE-10 ND-147 4.33E-01 4.84E-16 4.84E-07 1. OOE-09 P>=8 8. 64E+00 9.66E-15 1.97E-05 Date/Time: 04/07/2010 16:21 brwmn ID: Retdas Page - 1 33 of 104

RETDAS v3.6.3 <BRA> VSSI GASEOUS RELEASE AND DOSE

SUMMARY

REPORT - BY UNIT (Composite Critical Receptor - Limited Analysis)

Release ID ............. 1 All Gas Release Types Period Start Date ....  :.01/01/2009 00:00 Period End Date ......  :.01/01/2010 00:00 Period Duration (min): 5.256E+05 Coefficient Type ..... :.Historical Unit ..................  : 2 NUCLIDE DATA Average ECrcent Nuclide uCi uCi/cc Ratio EC Total 9.35E+07 1.05E-07 9.99E-01 Date/Time: 04/07/2010 16:21 brwmn ID: Retdas Page - 2 34 of 104

RETDAS v3.6.3 <BRA> VSSI GASEOUS RELEASE AND DOSE

SUMMARY

REPORT - BY UNIT (Composite Critical Receptor - Limited Analysis)

Release ID ............. 1 All Gas Release Types Period Start Date ....  :.01/01/2009 00:00 Period End Date ......  :.01/01/2010 00:00 Period Duration (min): 5.256E+05 Coefficient Type ..... Historical Unit ..................... 2 Receptor ............... 5 Composite Crit. Receptor - IP Distance (meters) ....  : 0.0 Compass Point .......... 0.0 PERIOD DOSE BY AGEGROUP, PATHWAY, ORGAN (mrem)

Age/Path Bone Liver Thyroid Kidney Lung GI-Lli Skin TB AGPD 3. 59E-06 3. 59E-06 3. 59E-06 3 .59E-06 3. 59E-06 3.59E-06 0 OOE+00 3.59E-06 AINHL 4. 66E-08 2.31E-03 2 .33E-03 2 .31E-03 2.31E-03 2.31E-03 0. 00E+00 2.31E-03 AVEG 1.21E-06 4. 15E-03 4. 70E-03 4. 15E-03 4.15E-03 4. 15E-03 0 OOE+00 4. 15E-03 AGMILK 5. 19E-06 2. 87E-03 5. 26E-03 2 .87E-03 2. 86E-03 2.86E-03 0. OOE+00 2. 86E-03 ACMEAT 1. 56E-07 5. 97E-04 6. 68E-04 5 97E-04 5. 97E-04 5.99E-04 0. 00E+00 5.97E-04 ACMILK 4. 35E-06 1.41E-03 3 .40E-03 1. 41E-03 1.40E-03 1.41E-03 0. 00E+00 1.40E-03 TGPD 3 . 59E-06 3. 59E-06 3. 59E-06 3 .59E-06 3 .59E-06 3.59E-06 0 OOE+00 3. 59E-06 TINHL 6.54E-08 2.33E-03 2 .35E-03 2. 33E-03 2. 33E-03 2.33E-03 0 .00E+00 2.33E-03 TVEG 1.16E-06 4.75E-03 5.21E-03 4 75E-03 4.75E-03 4.75E-03 0. 00E+00 4. 75E-03 TGMILK 9. 42E-06 3 .73E-03 7 .52E-03 3 .74E-03 3 .72E-03 3 .72E-03 0. 00E+00 3. 73E-03 TCMEAT 1.30E-07 3.56E-04 4. 07E-04 3. 56E-04 3 . 55E-04 3. 57E-04 0. OOE+00 3. 56E-04 TCMILK 7. 89E-06 1. 83E-03 4. 99E-03 1. 84E-03 1. 82E-03 1.84E-03 0. OOE+00 1. 83E-03 CGPD 3. 59E-06 3.59E-06 3 .59E-06 3 59E-06 3. 59E-06 3 .59E-06 0. OOE+00 3.59E-06 CINHL 8. 86E-08 2. 06E-03 2. 09E-03 2. 06E-03 2. 06E-03 2.06E-03 0 . OOE+00 2. 06E-03 CVEG 2. 15E-06 7 .38E-03 8. 07E-03 7 38E-03 7 .37E-03 7.38E-03 0. 00E+00 7.37E-03 CGMILK 2.28E-05 5. 91E-03 1.34E-02 5. 93E-03 5. 89E-03 5.90E-03 0. OOE+00 5.90E-03 CCMEAT 2.40E-07 4. 31E-04 5. 09E-04 4.31E-04 4. 31E-04 4.32E-04 0. OOE+00 4. 31E-04 CCMILK 1.91E-05 2. 91E-03 9. 17E-03 2 . 92E-03 2. 89E-03 2. 90E-03 0. OOE+00 2.90E-03 IGPD 3. 59E-06 3.59E-06 3 . 59E-06 3. 59E-06 3. 59E-06 3. 59E-06 0. 00E+00 3.59E-06 IINHL 7.02E-08 1.19E-03 1.21E-03 1.19E-03 1. 19E-03 1.19E-03 0. 00E+00 1.19E-03 IGMILK 4.77E-05 9. OOE-03 2 .72E-02 9. 01E-03 8. 94E-03 8. 94E-03 0. OOE+00 8.97E-03 ICMILK 3.99E-05 4.43E-03 1.96E-02 4.44E-03 4. 38E-03 4.39E-03 0. OOE+00 4. 40E-03

==PERIOD DOSE BY AGEGROUP, ORGAN (mrem) --------------------------------

Agegroup Bone Liver Thyroid Kidney Lung GI-Lli Skin TB ADULT 1.45E-05 1.13E-02 1.64E-02 1.13E-02 1.13E-02 1.13E-02 0. OOE+00 1.13E-02 TEEN 2.23E-05 1.30E-02 2.05E-02 1.30E-02 1.30E-02 1.30E-02 0. OOE+00 1.30E-02 CHILD 4.81E-05 1.87E-02 3.33E-02 1. 87E-02 1. 86E-02 1.87E-02 0. OOE+00 1. 87E-02 INFANT 9.13E-05 1.46E-02 4.81E-02 1.46E-02 1.45E-02 1.45E-02 0. OOE+00 1.46E-02 Date/Time: 04/07/2010 16:21 brwmn ID: Retdas Page - 3 35 of 104

RETDAS v3.6.3 <BRA> VSSI GASEOUS RELEASE AND DOSE

SUMMARY

REPORT - BY UNIT (Composite Critical Receptor - Limited Analysis)

Release ID ........... 1 All Gas Release Types Period Start Date .... 01/01/2009 00:00 Period End Date ....... 01/01/2010 00:00 Period Duration (min): 5.256E+05 Coefficient Type ..... Historical Unit .................. 2 Receptor .............. 5 Composite Crit. Receptor - IP Distance (meters) .... 0.0 Compass Point ........ 0.0 MAXIMUM PERIOD DOSE TO LIMIT (,Any Organ)

Dose Age Dose Limit Admin Admin % T.Spec T.Spec %

Period Group Organ (mrem) Period Limit of Limit Limit of Limit 4.81E-02 . . . . . . . . . . . . . . . . . . . . . . . . . . . .-

Strt->End INFANT THYROID Qrtr->End INFANT THYROID 4.81E-02 31-day 2.25E-01 2.14E+01 3.OOE-01 1.60E+01 Year->End INFANT THYROID 4.81E-02 Quarter 5.63E+00 8.55E-01 7.50E+00 6.41E-01 Annual 1.13E+01 4.28E-01 1.50E+01 3.21E-01 Critical Pathway ........  :.3 Grs/Goat/Milk (GMILK)

Major Contributors ......  :.0.0  % or greater to total Nuclide Percentage H-3 3.01E+01 CO-58 2.97E-03 AG-11OM 3.74E-03 1-131 6.86E+01 1-132 1.20E-03 1-133 1.25E+00 ND-147 3.97E-06 MAXIMUM PERIOD DOSE TO LIMIT (Tot Body) -

Dose Age Dose Limit Admin Admin % T.Spec T.Spec %

Period Group Organ (mrem) Period Limit of Limit Limit of Limit Strt->End CHILD TBODY 1.87E-02 31-day 1.50E-01 1.24E+01 2.OOE-01 9.34E+00 Qrtr->End CHILD TBODY 1.87E-02 Quarter 5.25E+00 3.56E-01 7.50E+00 2.49E-01 Year->End CHILD TBODY 1.87E-02 Annual 1.05E+01 1.78E-01 1.50E+01 1.24E-01 Critical Pathway ........ 2 Vegetation (VEG)

Major Contributors ....... 0.0 % or greater to total Nuclide Percentage H-3 9.96E+01 CO-58 1.34E-02 AG-11OM 1.OOE-02 1-131 1.33E-01 1-132 3.22E-04 1-133 3.37E-03 ND-147 1.03E-05 Date/Time: 04/07/2010 16:21 brwmn ID: Retdas Page - 4 36 of 104

RETDAS v3.6.3 <BRA> VSSI GASEOUS RELEASE AND DOSE

SUMMARY

REPORT - BY UNIT (Composite Critical Receptor - Limited Analysis)

Release ID ............. 1 All Gas Release Types Period Start Date ....  :.01/01/2009 00:00 Period End Date ...... 01/01/2010 00:00 Period Duration (min): 5.256E+05 Coefficient Type ..... :.Historical Unit ..................... 2 Receptor .... *........... 4 Composite Crit. Receptor - NG Distance (meters) ....  :.0.0 Compass Point .......... 0.0

=== MAXIMUM PERIOD NG DOSE TO LIMIT (Gamma)

Dose Dose Limit Admin Admin  % T.Spec T.Spec %

Period Dose Type (mrad) Period Limit of Limit Limit of Limit Strt->End Gamma 6.49E-05 Qrtr->End Gamma 6.49E-05 31-day 1.50E-01 4.33E-02 2.OOE-01 3.24E-02 Year->End Gamma 6.49E-05 Quarter 3.75E+00 1.73E-03 5.OOE+00 1.30E-03 Annual 7.50E+00 8.65E-04 1.OOE+01 6.49E-04 Major Contributors ...... .. 0.0  % or greater to total Nuclide Percentage AR-41 2.13E+00 KR-85M 2.29E-01 KR-85 1.32E-01 XE-133M 9.61E-01 KR-88 1.37E+00 XE-131M 2.58E-02 XE-135 3.15E+01 XE-133 6.36E+01 MAXIMUM PERIOD NG DOSE TO LIMIT (Beta))

Dose Dose Limit Admin Admin % T.Spec T.Spec %

Period Dose Type (mrad) Period Limit of Limit Limit of Limit Strt->End Beta 2.65E-04 Qrtr->End Beta 2.65E-04 31-day 3.OOE-01 8.84E-02 4.OOE-01 6.63E-02 Year->End Beta 2.65E-04 Quarter 7.50E+00 3.53E-03 1.OOE+01 2.65E-03 Annual 1.50E+01 1.77E-03 2.OOE+01 1.33E-03 Major Contributors ...... .. 0.0 % or greater to total Nuclide Percentage AR-41 3.OOE-01 KR-85M 1.46E-01 KR-85 5.99E+00 XE-133M 1.74E+00 KR-88 1.06E-01 XE-131M 7.33E-02 XE-135 1.61E+01 XE-133 7.55E+01 Date/Time: 04/07/2010 16:21 brwmn ID: Retdas LAST Page - 5 37 of 104

RETDAS v3.6.3 <BRA> VSSI LIQUID RELEASE AND DOSE

SUMMARY

REPORT


(PERIOD BASIS - BY UNIT)------

Release ID .............. 1 All Liquid Release Types Period Start Date ..... :.01/01/2009 00:00 Period End Date ....... 01/01/2010 00:00 Period Duration (mins): 5.256E+05 Unit ..................  : 1 MULTIPLE RELEASE POINT MESSAGE Undiluted and Diluted Flowrate(s) and Concentration(s) cannot be combined.

RELEASE DATA Total Release Duration (minutes) ..................................... 1.486E+06 Total Undiluted Volume Released (gallons) ............................ NA Average Undiluted Flowrate (gpm) ..................................... NA Total Dilution Volume (gallons) ...................................... NA Average Dilution Flowrate (gpm) ...................................... NA

--- NUCLIDE DATA Nuclide uCi CO-57 6.07E+02 NB-97 2.82E+01 SN-113 5.65E+00 SB-125 3.06E+03 TE-123M 1.10E+02 CR-51 3.25E+02 MN-54 1.19E+03 FE-59 2.71E+02 CO-58 1.10E+05 CO-60 1.09E+04 ZR-95 6.18E+01 NB-95 2.27E+02 AG-11OM 3.39E+01 TE-125M 3.80E+02 TE-132 3.83E+01 1-132 4.16E+01 CS-134 9.35E+02 CS-137 1.07E+03 BA-139 1.73E+01 Gamma 1.29E+05 KR-88 7.15E+00 D&EG 7.15E+00 H-3 5.29E+08 FE-55 6.82E+03 Date/Time: 04/07/2010 16:23 brwmn ID: Retdas Page - 1 38 of 104

RETDAS v3.6.3 <BRA> VSSI LIQUID RELEASE AND DOSE

SUMMARY

REPORT


(PERIOD BASIS - BY UNIT) -

Release ID .............. 1 All Liquid Release Types Period Start Date ..... :.01/01/2009 00:00 Period End Date .......  :.01/01/2010 00:00 Period Duration (mins): 5.256E+05 NUCLIDE DATA Nuclide uCi Beta 5.29E+08 ALPHA 1.71E+02 Alpha 1.71E+02 Total 5. 29E+08 Date/Time: 04/07/2010 16:23 brwmn ID: Retdas Page - 2 39 of 104

RETDAS v3.6.3 <BRA> VSSI LIQUID RELEASE AND DOSE

SUMMARY

REPORT


(PERIOD BASIS - BY UNIT)------

Release ID .............. 1 All Liquid Release Types Period Start Date ..... .. 01/01/2009 00:00 Period End Date .......  :.01/01/2010 00:00 Period Duration (mins): 5.256E+05 Unit ..................... 1 Receptor ...............  : 0 Liquid Receptor PERIOD DOSE BY AGEGROUP, PATHWAY, ORGAN (mrem)

Age/Path Bone Liver Thyroid Kidney Lung GI-Lli Skin TB APWtr 2. 28E-05 1.90E-02 1.90E-02 1.90E-02 1. 90E-02 1.93E-02 0. OOE+00 1. 90E-02 AFWFSp 1. 65E-02 3.74E-02 7.88E-03 1.76E-02 1. lIE-02 2. 31E-02 0. OOE+00 3. 01E-02 TPWtr 2. 20E-05 1.34E-02 1.34E-02 1.34E-02 1. 34E-02 1. 35E-02 0. OOE+00 1.34E-02 TFWFSp 1.74E-02 3.63E-02 6.05E-03 1.58E-02 9. 90E-03 1. 67E-02 0. OOE+00 1.90E-02 CPWtr 6.40E-05 2.58E-02 2.57E-02 2.57E-02 2. 57E-02 2. 58E-02 0. OOE+00 2.58E-02 CFWFSp 2. 15E-02 3.14E-02 5.02E-03 1.33E-02 8. 05E-03 8. 75E-03 0. OOE+00 1. 05E-02 IPWtr 6.29E-05 2.53E-02 2.52E-02 2.52E-02 2. 52E-02 2. 53E-02 0. OOE+00 2 .53E-02 PERIOD DOSE BY AGEGROUP, ORGAN (mrem)

Agegroup Bone Liver Thyroid Kidney Lung GI-Lli Skin TB ADULT 1. 65E-02 5. 64E-02 2.69E-02 3.66E-02 3 . 01E-02 4.24E-02 0. OOE+00 4. 91E- 02 TEEN 1.74E-02 4. 98E-02 1.94E-02 2 . 92E-02 2.33E-02 3. 02E-02 0. OOE+00 3.24E-02 CHILD 2. 16E-02 5. 72E-02 3. 07E-02 3. 90E-02 3.38E-02 3. 46E-02 0. OOE+00 3. 62E-02 INFANT 6.29E-05 2 .53E-02 2. 52E-02 2. 52E-02 2. 52E-02 2. 53E-02 0. OOE+00 2 . 53E-02 Date/Time: 04/07/2010 16:23 brwmn ID: Retdas Page - 3 40 of 104

RETDAS v3.6.3 <BRA> VSSI LIQUID RELEASE AND DOSE

SUMMARY

REPORT


(PERIOD BASIS - BY UNIT)------

Release ID .............. 1 All Liquid Release Types Period Start Date ..... :.01/01/2009 00:00 Period End Date .......  :.01/01/2010 00:00 Period Duration (mins): 5.256E+05 Unit ..................... 1 Receptor ................. 0 Liquid Receptor

=== MAXIMUM PERIOD DOSE TO LIMIT (Any Organ)

Dose Age Dose Limit Admin Admin % T.Spec T.Spec %

Period Group Organ (mrem) Period Limit of Limit Limit of Limit Strt->End CHILD LIVER 5.72E-0 2 31-day 1.50E-01 3.81E+01 2.OOE-01 2.86E+01 Qrtr->End CHILD LIVER 5.72E-0 2 Quarter 3.75E+00 1.52E+00 5.OOE+00 1.14E+00 Year->End CHILD LIVER 5.72E-0 2 Annual 7.50E+00 7.62E-01 1.OOE+01 5.72E-01 Critical Pathway ....... 1 Fresh Water Fish - Sport (FFSP)

Major Contributors ..... 0.0  % or greater to total Nuclide Percentage H-3 5.37E+01 CR-51 0.OOE+00 MN-54 1.68E-01 FE-55 3.01E-01 FE-59 2.47E-02 CO-58 3.52E-01 CO-60 1.03E-01 ZR-95 4.06E-07 NB-95 1.94E-03 AG-IIOM 2.78E-06 TE-125M 1.55E-02 TE-132 2.26E-03 1-132 3.90E-05 CS-134 2.34E+01 CS-137 2.19E+01 BA-139 1.08E-09 MAXIMUM PERIOD DOSE TO LIMIT (Tot Body))

Dose Age Dose Limit Admin Admin % T.Spec T.Spec %

Period Group Organ (mrem) Period Limit of Limit Limit of Limit Strt->End ADULT TBODY Qrtr->End ADULT TBODY 4.91E-0 2 31-day 4.50E-02 1.09E+02 6.OOE-02 8.19E+01 Year->End ADULT TBODY 4.91E-0 2 Quarter 1.13E+00 4.37E+00 1.50E+00 3.28E+00 4.91E-0 2 Annual 2.25E+00 2.18E+00 3.OOE+00 1.64E+00 Critical Pathway .......... 1 Fresh Water Fish - Sport (FFSP)

Major Contributors ...... .. 0.0 % or greater to total Nuclide . Percentage H-3 5.48E+01 CR-51 2.02E-05 Date/Time: 04/07/2010 16:23 brwmn ID: Retdas Page - 4 41 of 104

RETDAS v3.6.3 <BRA> VSSI LIQUID RELEASE AND DOSE

SUMMARY

REPORT


(PERIOD BASIS - BY UNIT)

Release ID .............. 1 All Liquid Release Types Period Start Date ..... :.01/01/2009 00:00 Period End Date .......  :.01/01/2010 00:00 Period Duration (mins): 5.256E+05' Major Contributors ...... .. 0.0  % or greater to total Nuclide Percentage MN-54 4.80E-02 FE-55 7.55E-02 FE-59 1.25E-02 CO-58 1.1lE+00 CO-60 3.09E-01 ZR-95 2.59E-07 NB-95 1.46E-03 AG-IIOM 1.53E-06 TE-125M 6.33E-03 TE-132 2.73E-03 1-132 1.56E-05 CS-134 2.61E+01 CS-137 1.77E+01 BA-139 3.50E-08 Date/Time: 04/07/2010 16:23 brwmn ID: Retdas LAST Page - 5 42 of 104

RETDAS v3.6.3 <BRA> VSSI LIQUID RELEASE AND DOSE

SUMMARY

REPORT


(PERIOD BASIS - BY UNIT)------

Release ID .............. 1 All Liquid Release Types Period Start Date ..... : 01/01/2009 00:00 Period End Date ....... .. 01/01/2010 00:00 Period Duration (mins): 5.256E+05 Unit ..................  : 2 MULTIPLE RELEASE POINT MESSAGE Undiluted and Diluted Flowrate(s) and Concentration(s) cannot be combined.

RELEASE DATA -----------

Total Release Duration (minutes) ..................................... 1.486E+06 Total Undiluted Volume Released (gallons) ............................ NA Average Undiluted Flowrate (gpm) ..................................... NA Total Dilution Volume (gallons) ...................................... NA Average Dilution Flowrate (gpm) ...................................... NA

=== NUCLIDE DATA Nuclide uCi CO-57 6.07E+02 NB-97 2.82E+01 SN-113 5.65E+00 SB-125 3.06E+03 TE-123M 1.10E+02 CR-51 3.25E+02 MN-54 1.19E+03 FE-59 2.71E+02 CO-58 1.10E+05 CO-60 1.09E+04 ZR-95 6.18E+01 NB-95 2.27E+02 AG-11OM 3.39E+01 TE-125M 3.80E+02 TE-132 3.83E+01 1-132 4.16E+01 CS-134 9.35E+02 CS-137 1.07E+03 BA-139 1.73E+01 Gamma 1.29E+05 KR-88 7.15E+00 D&EG 7.15E+00 H-3 5.29E+08 FE-55 6.82E+03 Date/Time: 04/07/2010 16:24 brwmn ID: Retdas Page - 1 43 of 104

RETDAS v3.6.3 <BRA> VSSI LIQUID RELEASE AND DOSE

SUMMARY

REPORT


(PERIOD BASIS - BY UNIT)------

Release ID .............. 1 All Liquid Release Types Period Start Date ..... :.01/01/2009 00:00 Period End Date ....... .. 01/01/2010 00:00 Period Duration (mins): 5.256E+05 NUCLIDE DATA Nuclide uCi Beta 5.29E+08 ALPHA 1.71E+02 Alpha 1. 71E+02 Total 5. 29E+08 Date/Time: 04/07/2010 16:24 brwmn ID: Retdas Page - 2 44 of 104

RETDAS v3.6.3 <BRA> VSSI LIQUID RELEASE AND DOSE

SUMMARY

REPORT


(PERIOD BASIS - BY UNIT)------

Release ID .............. 1 All Liquid Release Types Period Start Date ..... :.01/01/2009 00:00 Period End Date .......  :.01/01/2010 00:00 Period Duration (mins): 5.256E+05 Unit ..................... 2 Receptor ................. 0 Liquid Receptor PERIOD DOSE BY AGEGROUP, PATHWAY, ORGAN (mrem)

Age/Path Bone Liver Thyroid Kidney Lung GI-Lli Skin TB APWtr 2. 28E-05 1. 90E-02 1. 90E-02 1.90E-02 1.90E-02 1. 93E-02 0. OOE+00 1. 90E-02 AFWFSp 1. 65E-02 3.74E-02 7 . 88E-03 1.76E-02 1. lIE-02 2. 31E-02 0. OOE+00 3 1OE-02 TPWtr 2. 20E-05 1. 34E-02 1. 34E-02 1.34E-02 1.34E-02 1.35E-02 0. OOE+00 1. 34E-02 TFWFSp 1.74E-02 3 . 63E-02 6. 05E-03 1 . 58E-02 9. 90E-03 1. 67E-02 0. OOE+00 1. 90E-02 CPWtr 6.40E-05 2. 58E-02 2. 57E-02 2 . 57E-02 2. 57E-02 2 . 58E-02 0. OOE+00 2 .58E-02 CFWFSp 2. 15E-02 3. 14E-02 5. 02E-03 1 .33E-02 8. 05E-03 8. 75E-03 0. OOE+00 1. 05E-02 IPWtr 6.29E-05 2. 53E-02 2. 52E-02 2 . 52E-02 2. 52E-02 2. 53E-02 0. OOE+00 2. 53E-02 PERIOD DOSE BY AGEGROUP, ORGAN (mrem)

Agegroup Bone Liver Thyroid Kidney Lung GI-Lli Skin TB ADULT 1.65E-02 5.64E-02 2. 69E-02 3 .66E-02 3. 01E-02 4.24E-02 0. OOE+00 4. 91E-02 TEEN 1.74E-02 4. 98E-02 1.94E-02 2 .92E-02 2. 33E-02 3.02E-02 0. OOE+00 3.24E-02 CHILD 2. 16E-02 5. 72E-02 3.07E-02 3 .90E-02 3.38E-02 3.46E-02 0. OOE+00 3. 62E-02 INFANT 6. 29E-05 2.53E-02 2 .52E-02 2.52E-02 2. 52E-02 2. 53E-02 0. OOE+00 2. 53E-02 Date/Time: 04/07/2010 16:24 brwmn ID: Retdas Page - 3 45 of 104

RETDAS v3.6.3 <BRA> VSSI LIQUID RELEASE AND DOSE

SUMMARY

REPORT


(PERIOD BASIS - BY UNIT)------

Release ID .............  : 1 All Liquid Release Types Period Start Date ..... : 01/01/2009 00:00 Period End Date .......  : 01/01/2010 00:00 Period Duration (mins): 5.256E+05 Unit..................... 2 Receptor................. 0 Liquid Receptor

==MAXIMUM PERIOD DOSE TO LIMIT (Any Organ)---------------------

Dose Age Dose Limit Admin Admin % T.Spec T.Spec %

Period Group Organ (mrem) Period Limit of Limit Limit of Limit Strt->End CHILD LIVER Qrtr->End CHILD LIVER 5.72E-02 31-day 1.50E-01 3.81E+01 2.OOE-01 2. 86E+01 Year->End CHILD LIVER 5.72E-02 Quarter 3.75E+00 1.52E+00 5 . OOE+00 1. 14E+00 5.72E-02 Annual 7.50E+00 7.62E-01 1. OOE+01 5.72E-01 Critical Pathway ......... 1 Fresh Water Fish - Sport (FFSP)

Major Contributors ....... 0.0  % or greater to total Nuclide Percentage H-3 5.37E+01 CR-51 0.OOE+00 MN-54 1.68E-01 FE-55 3.01E-01 FE-59 2.47E-02 CO-58 3.52E-01 CO-60 1.03E-01 ZR-95 4.06E-07 NB-95 1.94E-03 AG-lIOM 2.78E-06 TE-125M 1.55E-02 TE-132 2.26E-03 1-132 3.90E-05 CS-134 2.34E+01 CS-137 2.19E+01 BA-139 1.08E-09 MAXIMUM PERIOD DOSE TO LIMIT (Tot Body))

Dose Age Dose Limit Admin Admin % T.Spec T.Spec %

Period Group Organ (mrem) Period Limit of Limit Limit of Limit Strt->End ADULT TBODY Qrtr->End ADULT TBODY 4.91E-02 31-day 4.50E-02 1.09E+02 6.OOE-02°8.19E+01 Year->End ADULT TBODY 4.91E-02 Quarter 1.13E+00 4.37E+00 1.50E+00 3.28E+00 4.91E-02 Annual 2.25E+00 2.18E+00 3.OOE+00 1.64E+00 Critical Pathway ........ :1 Fresh Water Fish - Sport (FFSP)

Major Contributors ......  :.0.0  % or greater to total Nuclide Percentage H-3 5.48E+01 CR-51 2. 02E-05 Date/Time: 04/07/2010 16:24 brwmn ID: Retdas Page - 4 46 of 104

RETDAS v3.6.3 <BRA> VSSI LIQUID RELEASE AND DOSE

SUMMARY

REPORT


(PERIOD BASIS - BY UNIT)------

Release ID .............. 1 All Liquid Release Types Period Start Date ..... .. 01/01/2009 00:00 Period End Date .......  :.01/01/2010 00:00 Period Duration (mins): 5.256E+05 Major Contributors ......  : 0.0  % or greater to total Nuclide Percentage MN-54 4. 80E-02 FE-55 7 . 55E-02 FE-59 1.25E-02 CO-58 1. lIE+00 CO-60 3.09E-01 ZR-95 2. 59E-07 NB-95 1.46E-03 AG-I1OM 1.53E-06 TE-125M 6.33E-03 TE-132 2. 73E-03 1-132 1.56E-05 CS-134 2. 61E+01 CS-137 1. 77E+01 BA-139 3 . 50E-08 Date/Time: 04/07/2010 16:24 brwmn ID: Retdas LAST Page - 5 47 of 104

BRAIDWOOD NUCLEAR POWER STATION RADIOACTIVE EFFLUENT RELEASE REPORT FOR 2009 UNIT 1 AND 2 (Docket Numbers 50-456 and 50-457)

ATTACHMENT 1 Tables 7-11 Wind Direction and Stability Classes 48 of 104

Braidwood Generating Station Period of Record: January - March 2009 Stability Class - Extremely Unstable - 199Ft-3OFt Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 1 1 0 0 2 0 1 7 5 0 0 13 NNE NE 0 1 2 0 0 0 3 ENE 0 1 0 0 0 0 1 E 0 5 0 0 0 0 5 ESE 0 5 1 0 0 0 6 SE 0 1 2 0 0 0 3 SSE 0 1 6 0 0 0 7 S 0 0 2 2 1 0 5 SSW 0 0 3 3 3 0 9 SW 0 1 0 3 0 0 4 WSW 0 0 1 1 0 0 2 W 0 1 2 5 0 0 8 0 11 26 5 0 0 42 WNW NW 0 8 16 1 0 0 25 NNW 0 1 9 4 0 0 14 Variable 0 0 0 0 0 0 0 Total 0 37 78 30 4 0 149 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability cl asses: 2 49 of 104

Braidwood Generating Station Period of Record: January - March 2009 Stability Class - Moderately Unstable - 199Ft-3OFt Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 3 0 0 0 3 NNE 0 0 7 0 0 0 7 NE 0 1 1 0 0 0 2 ENE 0 2 0 0 0 0 2 E 2 6 0 0 0 0 8 ESE 0 1 0 3 0 0 4 SE 0 5 3 1 0 0 9 SSE 0 3 4 1 0 0 8 S 0 1 3 5 0 0 9 SSW 0 2 0 1 0 0 3 SW 0 0 1 4 0 0 5 WSW 0 3 3 2 0 0 8 W 0 3 6 1 3 0 13 WNW 0 4 6 2 0 0 12 NW 0 3 4 0 0 0 7 NNW 0 1 4 0 0 0 5 Variable 0 0 0 0 0 0 0 Total 2 35 45 20 3 0 105 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability cl asses: 2 50 of 104

Braidwood Generating Station Period of Record: January - March 2009 Stability Class - Slightly Unstable - 199Ft-30Ft Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 5 NNE 2 NE 3 ENE 2 E 3 ESE 5 SE 7 SSE 5 S 14 SSW 10 SW 10 WSW 11 W 10 WNW 11 NW 5 NNW 6 Variable 0 Total 1 48 31 25 4 0 . 109 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2 51 of 104

Braidwood Generating Station Period of Record: January - March 2009 Stability Class - Neutral - 199Ft-3OFt Delta-T (F) winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 14 23 2 39 NNE 17 21 ii 50 NE 18 41 72 ENE 31 7 0 41 E 17 7 0 28 ESE 16 18 8 42 SE 13 10 12 37 SSE 18 29 9 58 S 6 27 24 61 SSW 10 10 17 41 SW 10 20 12 43 WSW 14 10 3 29 W 26 25 18 77 WNW 28 73 16 129 NW 19 37 8 73 NNW 28 36 17 83 Variable 1 0 0 2 Total 37 286 394 168 20 0 905 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2 52 of 104

Braidwood Generating Station Period of Record: January - March 2009 Stability Class - Slightly Stable - 199Ft-3OFt Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 6 6 3 0 15 NNE 8 7 0 0 15 NE 8 5 1 1 15 ENE 12 10 0 0 22 E 9 22 1 0 32 ESE 4 39 9 1 53 SE 1 21 18 5 45 SSE 2 25 34 4 66 S 1 5 31 16 54 SSW 0 1 16 15 36 SW 2 10 25 6 43 WSW 6 30 12 0 48 W 14 30 11 3 59 WNW 25 47 14 0 86 NW 28 37 5 0 70 NNW 5 25 6 0 36 Variable 0 0 0 0 0 Total 131 320 186 51 7 0 695 Hours of calm in this stability class: 3 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability cl asses: 2 53 of 104

Braidwood Generating Station Period of Record: January - March 2009 Stability Class - Moderately Stable - 199Ft-3OFt Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 4 0 0 4 NNE 1 1 0 2 NE 0 0 0 0 ENE 8 0 0 8 E 11 1 0 12 ESE 7 1 0 8 SE 1 7 0 8 SSE 1 0 0 1 S 2 1 0 3 SSW 1 7 0 10 SW 0 4 0 5 WSW 3 28 0 32 W 14 17 0 32 WNW 9 3 0 12 NW 7 3 0 10 NNW 4 1 0 5 Variable 0 0 0 0 Total 73 74 5 0 0 0 152 Hours of calm in this stability class: 4 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2 54 of 104

Braidwood Generating Station Period of Record: January - March 2009 Stability Class - Extremely Stable - 199Ft-3OFt Delta-T (F)

Winds Measured at 34 Feet wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 0 0 1 NNE 0 0 0 0 NE 3 0 0 3 ENE 7 0 0 7 E 6 0 0 6 ESE 1 0 0 1 SE 1 0 0 3 SSE 1 0 0 1 S 0 0 0 0 SSW 0 0 0 0 SW 0 0 0 1 WSW 2 0 0 4 W 3 0 0 4 WNW 0 0 0 0 NW 0 0 0 0 NNW 0 0 0 0 Variable 0 0 0 0 Total 25 0 0 31 Hours of calm in this stability class: 5 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2 55 of 104

Braidwood Generating Station Period of Record: January - March 2009 Stability Class - Extremely Unstable - 199Ft-3OFt Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 2 1 3 NNE 2 4 9 NE 3 3 6 ENE 0 0 1 E 2 0 4 ESE 4 1 7 SE 4 0 4 SSE 1 3 5 S 0 4 7 SSW 3 0 9 SW 0 0 3 WSW 2 0 3 W 0 1 4 WNW 15 16 38 NW 21 12 38 NNW 2 2 8 Variable 0 0 0 Total 0 7 61 47 27 7 149 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2 56 of 104

Braidwood Generating Station Period of Record: January - March 2009 Stability Class - Moderately Unstable - 199Ft-3OFt Delta-T (F)

Winds Measured at 203 Feet Wind

  • Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 0 2 1 0 0 3 NNE 0 0 1 6 0 0 7 NE 0 0 1 1 0 0 2 ENE 0 1 1 0 0 0 2 E 0 6 0 0 0 0 6 ESE 0 3 1 0 2 2 8 SE 0 3 3 1 1 0 8 SSE 0 2 1 4 0 0 7 S 0 0 2 1 5 1 9 SSW 0 1 1 0 2 0 4 SW 0 0 0 1 1 1 3 WSW 0 2 2 2 3 0 9 W 0 1 5 0 1 3 10 WNW 0 0 7 5 2 0 14 NW 0 2 2 2 1 0 7 NNW 0 0 5 1 0 0 6 variable 0 0 0 0 0 0 0 Total 0 21 34 25 18 7 105 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stabi lity classes: 2 57 of 104

Braidwood Generating Station Period of Record: January - March 2009 Stability Class - Slightly Unstable - 199Ft-3OFt Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 6 NNE 1 NE 3 ENE 2 E 4 ESE 4 SE 7 SSE 6 S 15 SSW 10 SW 8 WSW 13 W 9 WNW 9 NW 6 NNW 6 Variable 0 Total 0 30 26 25 19 9 109 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability cl asses: 2 58 of 104

Braidwood Generating Station Period of Record: January - March 2009 Stability Class - Neutral - 199Ft-3OFt Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 19 16 2 0 38 NNE 4 13 13 6 5 41 NE 11 12 40 8 5 76 ENE 10 18 12 0 0 41 E 6 11 8 2 0 28 ESE 2 12 10 12 9 45 SE 7 6 9 7 11 40 SSE 2 25 14 7 10 58 S 0 7 21 24 9 61 SSW 4 9 10 21 8 52 SW 8 5 8 5 5 32 WSW 7 6 9 3 1 26 W 7 11 12 8 13 53 WNW 10 23 49 33 13 129 NW 16 14 41 28 2 103 NNW 10 32 20 14 4 80 Variable 1 0 0 0 0 2 Total 9 106 223 292 180 95 905 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability cl asses: 2 59 of 104

Braidwood Generating Station Period of Record: January - March 2009 Stability Class - Slightly Stable - 199Ft-3OFt D elta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 6 13 2 0 0 21 NNE 2 7 0 0 0 10 NE 2 7 3 0 1 13 ENE 7 14 0 0 0 21 E 3 9 9 2 0 23 ESE 0 24 19 4 6 53 SE 2 20 15 8 1 46 SSE 1 20 27 12 2 62 S 1 12 32 17 7 69 SSW 0 3 7 23 16 51 SW 3 8 10 5 2 28 WSW 4 9 20 4 0 37 W 10 11 20 5 1 47 WNW 8 25 44 5 0 82 NW 7 51 19 1 0 79 NNW 4 34 18 0 0 56 Variable 0 0 0 0 0 0 Total 4 60 267 245 86 36 698 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 2 60 of 104

Braidwood Generating Station Period of Record: January - March 2009 Stability Class - Moderately Stable - 199Ft-3OFt Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 5 1 8 NNE 1 0 4 NE 0 0 3 ENE 0 0 1 E 4 1 7 ESE 3 6 12 SE 4 0 5 SSE 6 0 8 S 3 0 3 SSW 2 3 8 SW 5 2 7 WSW 1 5 8 W 11 20 33 WNW 15 10 30 NNW 7 2 12 NNW 3 2 7 Var iabl1e 0 0 0 Total 5 28 70 52 1 0 156 Hours of calm in this stability class: 0 Hours of' missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability cl asses: 2 61 of 104

Braidwood Generating Station Period of Record: January - March 2009 Stability Class - Extremely Stable - 199Ft-3OFt Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW Variable Total 7 11 15 3 0 0 36 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability cl asses: 2 62 of 104

Braidwood Generating Station Period of Record: April - June 2009 Stability Class - Extremely Unstable - 199Ft-3OFt Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 6 0 0 0 6 NNE 1 12 16 0 0 29 NE 0 17 15 0 0 32 ENE 0 12 1 0 0 13 E 0 8 3 0 0 11 ESE 0 4 2 0 0 6 SE 1 6 3 4 0 14 SSE 0 3 8 0 0 11 S 0 1 7 0 0 8 SSW 0 0 0 15 1 16 SW 0 1 4 2 0 7 WSW 1 6 8 6 0 21 W 0 17 12 4 0 33 WNW 1 16 19 13 0 49 NW 0 16 9 5 0 30 NNW 0 8 1 1 0 10 Variable 1 1 0 0 0 2 Total 5 134 108 50 1 0 298 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 1 63 of 104

Braidwood Generating Station Period of Record: April - June 2009 Stability Class - Moderately Unstable - 199Ft-3OFt Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 2 NNE 1 11 NE 0 12 ENE 0 5 E 0 5 ESE 0 2 SE 0 9 SSE' 1 10 S 1 2 SSW 1 4 SW 4 11 WSW 1 4 W 2 14 WNW 1 8 NW 0 11 NNW 1 8 Variable 0 2 Total 16 53 38 13 0 0 120 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 1 64 of 104

Braidwood Generating Station Period of Record: April - June 2009 Stability Class - Slightly Unstable - 199Ft-30Ft Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 4 NNE 2 11 NE 0 ENE 3 6 E 1 8 ESE 1 3 SE 2 5 SSE 0 .7 S 0 1 SSW 0 8 SW 1 5 WSW 1 8 W 1 10 WNW 1 10 NW 1 9 NNW 0 4 Variable 1 1 Total 15 49 34 11 2 0 Ill Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 1 65 of 104

Braidwood Generating Station Period of Record: April - June 2009 Stability Class - Neutral - 199Ft-3OFt Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 2 7 15 8 32 NNE 3 48 32 13 96 NE 8 53 38 4 103 ENE 7 30 29 0 66 E 8 24 6 0 38 ESE 4 25 5 0 34 SE 2 13 10 2 27 SSE 1 12 8 1 22 S 2 9 15 5 33 SSW 1 5 13 10 36 SW 2 7 13 12 35 WSW 2 6 3 3 14 W 6 14 18 6 45 WNW 7 34 17 4 62 NW 3 24 22 0 49 NNW 0 7 22 4 33 Variable 1 0 0 0 1 Total 59 318 266 72 11 0 726 Hours of calm in this stability class: 1 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 1 66 of 104

Braidwood Generating Station Period of Record: April - June 2009 Stability C:lass - Slightly Stable - 199Ft-3OFt Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 6 8 1 0 15 NNE 6 27 4 1 38 NE 15 18 1 0 34 ENE 27 29 1 0 57 E 24 17 0 0 41 ESE 8 27 1 0 36 SE 7 17 11 0 35 SSE 5 35 9 1 50 S 3 29 40 12 84 SSW 3 11 24 11 50 SW 3 18 10 2 33 WSW 5 39 3 3 50 W 16 30 10 0 56 WNW 13 20 1 0 34 NW 6 15 4 0 25 3 15 4 0 22 NNW Variable 1 0 0 0 1 Total 151 355 124 30 1 0 661 Hours of calm in this stability class: 4 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 1 67 of 104

Braidwood Generating Station Period of Record: April - June 2009 Stability Class - Moderately Stable - 199Ft-3OFt Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 2 1 3 NNE 4 0 4 NE 9 1 10 ENE 15 1 16 E 13 1 14 ESE 6 2 8 SE 6 3 9 SSE 3 2 5 S 2 0 2 SSW 1 0 1 SW 5 3 8 WSW 11 19 30 W 19 9 28 WNW 14 1 15 NW 6 0 6 NNW 2 1 3 Variable 0 0 0 Total 118 44 0 0 0 0 162 Hours of calm in this stability class: 15 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 1 68 of 104

Braidwood Generating Station Period of Record: April - June 2009 Stability Class - Extremely Stable - 199Ft-30Ft Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total 0 0 N 0 0 0 0 0 0 0 NNE 1 0 0 0 1 0 0 NE 3 0 0 0 3 0 0 ENE 7 0 0 0 7 0 0 E 8 0 0 0 8 0 0 ESE 5 4 0 0 9 0 0 SE 2 0 0 0 2 0 0 SSE 1 0 0 0 1 0 0 S 0 0 0 0 0 0 0 SSW 1 0 0 0 1 0 0 SW 4 0 0 0 4 0 0 WSW 4 5 0 0 9 0 0 W 11 2 0 0 13 0 0 WNW 5 0 0 0 5 0 0 NW 5 0 0 0 5 0 0 NNW 1 0 0 0 1 0 0 Variable 0 0 0 0 0 Total 58 11 0 0 0 0 69 Hours of calm in this stability class: 16 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 1 69 of 104

Braidwood Generating Station Period of Record: April - June 2009 Stability Class - Extremely Unstable - 199Ft-30Ft Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph) wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 8 1 0 0 0 9 NNE 0 3 10 7 0 0 20 NE 0 7 19 10 0 0 36 ENE 0 4 6 1 0 0 11 E 1 2 9 3 0 0 15 ESE 0 2 4 1 0 0 7 SE 1 5 2 1 6 0 15 SSE 0 1 4 6 0 0 11 S 0 0 1 6 0 0 7 0 1 0 3 13 2 19 0 0 0 4 0 0 4 3 2 5 7 0 17 W 4 18 12 1 0 35 WNW 1 3 16 10 22 1 53 NW 0 3 14 4 11 0 32 NNW 0 5 0 1 0 0 6 Variable 1 0 0 0 0 0 1 Total 4 51 106 74 60 3 298 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 1 70 of 104

I Braidwood Generating Station Period of Record: April - June 2009 Stability Class - Moderately Unstable - 199Ft-30Ft Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 2 NNE 2 8 NE 10 15 ENE 1 6 E 1 5 ESE 0 4 SE 1 6 SSE 2 9 S 0 2 SSW 1 "7 SW 1 9 WSW 1 4 W 5 13 WNW 4 8 NW 5 13 NNW 1 7 Variable 0 1 Total 9 41 20 35 10 4 119 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 1 Hours of missing stability measurements in all stability cl asses:

71 of 104

Braidwood Generating Station Period of Record: April - June 2009 Stability Class - Slightly Unstable - 199Ft-3OFt Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 5 NNE 0 8 NE 0 12 ENE 2 4 E 1 10 ESE 1 2 SE 1 6 SSE 0 7 S 0 2 SSW 0 10 SW 1 4 WSW 0 8 W 1 10 WNW 0 8 NW 0 10 NNW 1 4 Variable 1 1 Total 9 31 24 30 14 3 111 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 1

Hours of missing stability measurements in all stability classes:

72 of 104

Braidwood Generating Station Period of Record: April - June 2009 Stability Class - Neutral - 199Ft-3OFt Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 3 7 9 10 1 31 NNE 4 37 22 11 1 77 NE 14 49 39 11 0 116 ENE 2 26 22 3 0 55 E 8 25 19 1 0 55 ESE 6 4 22 2 0 34 SE 10 4 7 4 1 26 SSE 7 6 5 4 1 26 S 4 5 15 1 6 31 SSW 2 4 9 13 10 38 SW 4 5 12 7 3 31 WSW 0 6 2 3 0 12 W 8 13 14 6 1 42 WNW 6 30 15 18 1 72 NW 7 12 20 3 0 44 3 4 23 4 0 34 NNW Variable 0 0 0 0 0 2 Total 20 88 237 255 101 25 726 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 1 Hours of missing stability measurements in all stability classes: 1 73 of 104

Braidwood Generating Station Period of Record: April - June 2009 Stability Class - Slightly Stable - 199Ft-3OFt Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 8 3 0 0 15 NNE 20 6 1 0 29 NE 26 7 0 0 41 ENE 36 3 0 0 56 E 22 11 0 0 37 ESE 16 15 1 2 36 SE 25 11 5 0 47 SSE 16 11 4 1 38 S 19 35 22 7 85 SSW 10 31 5 12 62 SW 13 9 1 0 32 WSW 13 18 4 0 42 W 19 19 1 0 47 WNW 15 19 1 0 44 NW 22 8 1 0 32 NNW 14 5 0 0 20 Variable 0 0 0 0 0 Total 5 85 294 211 46 22 663 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 2 Hours of missing stability measurements in all stability classes: 1 74 of 104

Braidwood Generating Station Period of Record: April - June 2009 Stability Class - Moderately Stable - 199Ft-3OFt Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 5 0 9 NNE 3 0 5 NE 3 1 6 ENE 12 0 16 E 9 0 12 ESE 7 6 14 SE 4 2 9 SSE 3 2 6 S 2 0 7 SSW 1 0 6 SW 3 0 3 WSW 5 3 9 W 19 13 36 WNW 14 5 23 NW 5 0 9 NNW 5 0 7 variable 0 0 0 Total 8 37 100 32 0 0 177 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class:. 0 Hours of missing stability measurements in all stability classes: 1 75 of 104

Braidwood Generating Station Period of Record: April - June 2009 Stability Class - Extremely Stable - 199Ft-30Ft Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 4 NNE 2 NE 1 ENE 4 E 8 ESE 4 SE 10 SSE 1 S 4 SSW 6 SW 2 WSW 1 W 18 WNW 9 NW 6 NNW 5 Variable 0 Total 8 29 33 15 0 0 85 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: I 76 of 104

Braidwood Generating Station Period of Record: July - September 2009 Stability Class - Extremely Unstable - 199Ft-3OFt Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 17 2 19 NNE 19 2 21 NE 42 5 50 ENE 33 1 39 E 14 0 17 ESE 5 1 7 SE 7 5 14 SSE 11 3 14 S 8 2 10 SSW 4 19 32 SW 10 17 29 WSW 14 13 27 W 24 18 42 WNW 34 10 44 NW 43 5 48 NNW 20 7 27 Variable 0 0 0 Total 14 305 110 11 0 0 440 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4 77 of 104

Braidwood Generating Station Period of Record: July - September 2009 Stability Class - Moderately Unstable - 199Ft-30Ft Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 3 5 NNE 6 8 NE 8 12 ENE 13 17 E 3 7 ESE 4 4 SE 5 7 SSE 2 2 S 3 5 SSW 0 2 SW 1 6 WSW 8 14 W 3 7 WNW 7 8 NW 5 9 NNW 3 5 Variable 0 0 Total 17 74 25 2 0 0 118 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4 78 of 104

Braidwood Generating Station Period of Record: July - September 2009 Stability Class - Slightly Unstable - 199Ft-3OFt Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW Variable Total 18 39 20 6 0 0 83 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4 79 of 104

Braidwood Generating Station Period of Record: July - September 2009 Stability Class - Neutral - 199Ft-3OFt Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 6 11 0 0 0 0 17 NNE 5 14 1 0 0 0 20 NE 20 29 6 0 0 0 55 ENE 29 31 0 0 0 0 60 E 19 9 0 0 0 0 28 ESE 7 21 1 0 0 0 29 SE 3 12 5 0 0 0 20 SSE 0 14 7 0 0 0 21 S 1 7 9 0 0 0 17 SSW 1 6 27 5 0 0 39 SW 1 19 22 2 0 0 44 WSW 7 27 10 0 0 0 44 W 9 14 5 8 0 0 36 WNW 10 29 7 0 0 0 46 NW 6 19 8 0 0 0 33 NNW 9 23 3 0 0 0 35 Variable 0 0 0 0 0 0 0 Total 133 285 il1 15 0 0 544 Hours of calm in this stability class: 1 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4 80 of 104

Braidwood Generating Station Period of Record: July - September 2009 Stability Class - Slightly Stable - 199Ft-3OFt Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 10 7 1 0 0 0 18 NNE 16 26 0 0 0 0 42 NE 43 8 0 0 0 0 51 ENE 53 11 1 0 0 0 65 E 35 5 0 0 0 0 40 ESE 17 9 0 0 0 0 26 SE 8 37 2 0 0 0 47 SSE 3 16 4 0 0 0 23 S 2 34 9 0 0 0 45 SSW 2 27 22 1 0 0 52 SW 2 14 9 0 0 0 25 WSW 11 21 3 0 0 0 35 W 29 15 0 3 0 0 47 WNW 26 8 3 0 0 0 37 NW 13 15 0 1 0 0 29 NNW 13 11 0 0 0 0 24 Variable 0 0 0 0 0 0 0 Total 283 264 54 5 0 606 Hours of calm in this stability class: 1 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4 81 of 104

Braidwood Generating Station Period of Record: July - September 2009 Stability Class - Moderately Stable - 199Ft-3OFt Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 15 1 16 NNE 15 0 15 NE 24 0 24 ENE 30 0 30 E 28 0 28 ESE 21 4 25 SE 2 1 3 SSE 6 0 6 S 3 0 3 SSW 5 3 8 SW 3 2 6 WSW 11 11 22 W 31 1 32 WNW 25 0 25 NW 13 0 13 NNW 12 0 12 Variable 0 0 0 Total 244 23 1 0 0 0 268 Hours of calm in this stability class: 11 Hours of missing Wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4 82 of 104

Braidwood Generating Station Period of Record: July - September 2009 Stability Class - Extremely Stable - 199Ft-3OFt Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 8 8 NNE 14 14 NE 4 4 ENE 15 15 E 8 8 ESE 6 6 SE 1 1 SSE 0 0 S 1 1 SSW 0 0 SW 1 1 WSW 6 6 W 6 6 WNW 16 16 NW 8 8 NNW 5 5 Variable 0 0 Total 99 0 0 0 0 0 99 Hours of calm in this stability class: 33 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability cl asses: 4 83 of 104

Braidwood Generating Station Period of Record: July - September 2009 Stability Class - Extremely Unstable - 199Ft-3OFt Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 10 9 0 19 NNE 13 7 0 20 NE 23 16 3 44 ENE 29 14 0 44 E 14 5 0 22 ESE 2 4 1 8 SE 5 8 1 15 SSE 3 5 1 9 S 7 7 1 15 SSW 0 5 16 31 SW 2 11 14 28 WSW 4 12 6 22 W .9 20 12 41 13 24 11 48 WNW 31 3 44 NW 10 NNW 15 9 6 30 Variable 0 0 0 0 Total 6 159 187 75 11 2 440 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4 84 of 104

Braidwood Generating Station Period of Record: July - September 2009 Stability Class - Moderately Unstable - 199Ft-30Ft Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 5 7 NNE 4 6 NE 9 15 ENE 10 14 E 5 7 ESE 2 4 SE 1 7 SSE 1 1 S 4 6 SSW 0 2 SW 2 6 WSW 4 12 W 1 8 WNW 4 8 NW 5 NNW 1 4 Variable 0 0 Total 7 58 36 15 0 2 118 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability cl asses: 4 85 of 104

Braidwood Generating Station Period of Record: July - September 2009 Stability Class - Slightly Unstable - 199Ft-3OFt Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 NNE 1 NE 2 ENE 1 E 0 ESE 1 SE 0 SSE 0 S 0 SSW 0 SW 0 WSW 0 W 0 WNW 1 NW 0 NNW 1 Variable 0 Total 8 24 25 19 4 3 83 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4 86 of 104

Braidwood Generating Station Period of Record: July - September 2009 Stability Class - Neutral - 199Ft-3OFt Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 12 8 0 0 21 NNE 9 3 1 0 15 NE 18 18 9 0 50 ENE 33 29 0 0 66 E 17 15 1 0 34 ESE 5 13 9 0 28 SE 6 10 5 0 21 SSE 2 12 10 0 25 S 2 5 5 1 15 SSW 1 8 22 19 50 SW 3 20 12 0 35 WSW 13 10 8 0 32 W 12 12 2 6 36 WNW 7 19 11 5 44 NW 8 26 11 0 46 NNW 5 18 2 0 27 Variable 0 0 0 0 0 Total 24 153 226 108 31 3 545 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4 87 of 104

Braidwood Generating Station Period of Record: July - September 2009 Stability Class - Slightly Stable - 199Ft-3OFt Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 7 5 0 14 NNE 0 6 12 5 23 NE 1 7 46 4 58 ENE 1 28 42 0 71 E 2 9 35 2 48 ESE 0 4 14 7 25 SE 0 5 24 16 45 SSE 1 4 14 7 26 S 0 2 13 30 46 SSW 0 3 15 31 58 SW 0 7 10 10 28 WSW 0 6 15 6 27 W 0 3 20 3 28 WNW 1 8 26 3 42 NW 1 14 21 5 42 NNW 0 7 19 0 26 Variable 0 0 0 0 0 Total 8 120 331 129 17 2 607 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4 88 of 104

Braidwood Generating Station Period of Record: July - September 2009 Stability Class - Moderately Stable - 199Ft-30Ft Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 2 5 1 0 0 8 NNE 0 3 6 0 0 0 9 NE 1 2 23 2 0 0 28 ENE 0 19 18 1 0 0 38 E 1 2 13 3 0 0 19 ESE 0 1 19 12 0 0 32 SE 1 6 6 1 0 0 14 SSE 0 2 1 0 0 0 3 S 0 3 4 0 0 0 7 SSW 0 4 3 0 0 0 7 SW 0 3 6 3 0 0 12 WSW 0 1 5 1 0 0 7 W 0 1 19 4 0 0 24 WNW 0 3 19 3 0 0 25 NW 0 2 22 1 0 0 25 NNW 2 4 15 0 0 0 21 Variable 0 0 0 0 0 0 0 Total 5 58 184 32 0 0 279 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability cl asses: 4 89 of 104

Braidwood Generating Station Period of Record: July - September 2009 Stability Class - Extremely Stable - 199Ft-3OFt Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 11 NNE 9 NE 17 ENE 17 E 12 ESE 7 SE 4 SSE 8 S 6 SSW 1 SW 2 WSW 2 W 7 WNW 6 NW 9 NNW 14 Variable 0 Total 18 41 65 8 0 0 132 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 4 90 of 104

Braidwood Generating Station Period of Record: October - December 2009 Stability Class - Extremely Unstable - 199Ft-3OFt Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 3 3 NNE 3 3 NE 1 3 ENE 0 4 E 0 1 ESE 0 0 SE 0 1 SSE 1 3 S 2 5 SSW 5 11 SW 3 5 WSW 10 10 W 11 23 WNW 6 8 NW 5 7 NNW 1 4 Variable 0 0 Total 0 24 51 16 0 0 91 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 22 91 of 104

Braidwood Generating Station Period of Record: October - December 2009 Stability Class - Moderately Unstable - 199Ft-3OFt Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 1 NNE 0 NE 1 ENE 0 E 0 ESE 0 SE 3 SSE 5 S 8 SSW 10 SW 5 WSW 8 W 10 WNW 3 NW 2 NNW 5 Variable 0 Total 2 22 30 7 0 0 61 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 22 92 of 104

Braidwood Generating Station Period of Record: October - December 2009 Stability Class - Slightly Unstable - 199Ft-3OFt Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW variable Total 5 31 23 3 0 0 62 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 22 93 of 104

Braidwood Generating Station Period of Record: October - December 2009 Stability Class - Neutral - 199Ft-3OFt Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 6 15 11 3 35 NNE 7 29 6 0 42 NE 13 40 25 0 78 ENE 7 52 33 0 92 E 15 28 25 0 68 ESE 6 14 13 1 34 SE 3 29 23 0 55 SSE 3 39 41 3 86 S 0 17 38 12 67 SSW 0 10 37 29 76 SW 3 23 60 25 i1 WSW 3 59 56 13 141 W 14 48 42 20 124 WNW 5 38 34 1 78 NW 10 20 21 0 51 NNW 3 20 34 2 59 Variable 0 0 0 0 0 Total 98 481 499 109 9 1 1197 Hours of calm in this stability class: 1 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 22 94 of 104

Braidwood Generating Station Period of Record: October - December 2009 Stability Class - Slightly Stable - 199Ft-3OFt Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total 0 0 N 1 5 0 0 6 0 0 NNE 6 13 0 0 19 0 0 NE 6 11 0 0 17 0 0 ENE 13 5 0 0 18 10 0 E 13 13 0 0 36 ESE 11 31 10 1 0 0 53 SE 4 42 24 1 0 0 71 SSE 3 41 24 1 0 0 69 S 2 37 57 6 0 0 102 SSW 0 8 28 11 0 0 47 SW 2 10 14 2 0 0 28 WSW 2 31 11 1 0 0 45 W 11 13 5 2 0 0 31 WNW 16 17 2 0 0 0 35 NW 11 13 1 0 0 0 25 NNW 6 8 0 0 0 0 14 Variable 0 0 0 0 0 0 0 Total 107 298 186 25 0 0 616 Hours of calm in this stability class: 5 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 22 95 of 104

Braidwood Generating Station Period of Record: October - December 2009 Stability Class - Moderately Stable - 199Ft-3OFt Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18. 19-24 > 24 Total N 2 2 NNE 3 3 NE 3 5 ENE 3 3 E 14 16 ESE 4 10 SE 1 2 SSE 2 2 S 2 4 SSW 1 4 SW 3 5 WSW 5 13 W 9 11 WNW 12 19 NW 3 4 NNW 1 1 Variable 0 0 Total 68 35 1 0 0 0 104 Hours of calm in this stability class: 2 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability cl asses: 22 96 of 104

Braidwood Generating Station Period of Record: October - December 2009 Stability Class - Extremely Stable - 199Ft-30Ft Delta-T (F)

Winds Measured at 34 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW Variable Total 40 1 0 0 0 0 41 Hours of calm in this stability class: 6 Hours of missing wind measurements in this stability class: 0 Hours of missing stability measurements in all stability classes: 22 97 of 104

Braidwood Generating Station Period of Record: October - December 2009 Stability Class - Extremely Unstable - 199Ft-30Ft Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 3 NNE 3 NE 3 ENE 3 E 2 ESE 0 SE 1 SSE 3 S 5 SSW 12 SW 4 WSW 10 W 13 WNW 16 NW 5 NNW 4 Variable 0 Total 1 3 41 30 12 0 87 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 4 Hours of missing stability measurements in all stability classes: 22 98 of 104

Braidwood Generating Station Period of Record: October - December 2009 Stability Class - Moderately Unstable - 199Ft-3OFt Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW Variable Total 1 10 27 11 7 0 56 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 5 Hours of missing stability measurements in all stability classes: 22 99 of 104

Braidwood Generating Station Period of Record: October - December 2009 Stability Class - Slightly Unstable - 199Ft-3OFt Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 NNE 0 NE 1 ENE 1 E 1 ESE 0 SE 0 SSE 0 S 0 SSW 0 SW 0 WSW 0 W 1 WNW 0 NW 0 NNW 0 Variable 0 Total 4 11 27 14 3 0 59 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 3 Hours of missing stability measurements in all stability classes: 22 100 of 104

Braidwood Generating Station Period of Record: October - December 2009 Stability Class - Neutral - 199Ft-3OFt Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 3 17 6 3 31 NNE 4 25 5 0 34 NE 22 26 22 8 79 ENE 12 38 34 0 86 E 16 16 26 10 72 ESE 7 9 6 5 28 SE 10 22 18 7 60 SSE 6 33 25 13 78 S 3 12 28 15 61 SSW 2 12 36 26 81 SW 11 36 33 18 100 WSW 9 42 41 8 101 W 22 32 34 5 97 WNW 15 32 41 11 103 NW 8 20 23 8 62 NNW 8 19 31 2 62 Variable 0 0 0 0 0 Total 21 158 391 409 139 17 1135 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 63 Hours of missing stability measurements in all stability classes: 22 101 of 104

Braidwood Generating Station Period of Record: October - December 2009 Stability Class - Slightly Stable - 199Ft-3OFt Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 5 0 0 8 NNE 5 6 0 15 NE 8 5 0 19 ENE 3 1 0 15 E 12 5 3 31 ESE 5 14 3 28 SE 32 29 2 68 SSE 33 32 8 77 S 16 53 12 89 SSW 17 24 12 56 SW 10 18 2 31 WSW 14 15 0 30 W 18 4 1 29 WNW 16 13 0 32 NW 22 8 0 32 NNW 12 1 0 14 Variable 0 0 0 0 Total 21 44 228 228 43 10 574 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 47 Hours of missing stability measurements in all stability classes: 22 102 of 104

Braidwood Generating Station Period of Record: October - December 2009 Stability Class - Moderately Stable - 199Ft-3OFt Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 1 NNE 0 3 NE 0 7 ENE 0 1 E 0 6 ESE 0 10 SE 0 11 SSE 0 3 S 1 2 SSW 0 5 SW 0 5 WSW 0 7 W 0 6 WNW 0 17 NW 0 11 NNW 0 8 variable 0 0 Total 1 18 56 28 0 0 103 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 3 Hours of missing stability measurements in all stability classes: 22 103 of 104

Braidwood Generating Station Period of Record: October - December 2009 Stability Class - Extremely Stable - 199Ft-3OFt Delta-T (F)

Winds Measured at 203 Feet Wind Speed (in mph)

Wind Direction 1-3 4-7 8-12 13-18 19-24 > 24 Total N 0 1 0 1 NNE 0 1 0 1 NE 0 0 0 0 ENE 0 1 0 2 E 0 1 0 7 ESE 0 0 0 0 SE 0 0 0 0 SSE 0 1 0 2 S 0 2 0 2 SSW 0 7 0 11 SW 0 2 0 2 WSW 0 2 0 2 W 1 4 0 7 WNW 0 2 0 2 NW 0 1 0 3 NNW 0 3 0 4 variable 0 0 0 0 Total 1 28 15 2 0 0 46 Hours of calm in this stability class: 0 Hours of missing wind measurements in this stability class: 1 Hours of missing stability measurements in all stability classes: 22 104 of 104