Category:Memoranda
MONTHYEARML23324A4332024-01-23023 January 2024 10/16-17/2023 Summary of Routine NRC Site Visit at the Oyster Creek Nuclear Generating Station to Discuss License Termination Plans and Other Technical Topics ML20150A3252020-11-23023 November 2020 Memo to File: Environmental Assessment and Finding of No Significant Impact and NRC Financial Analysis for Exelon Generation Co., LLC Decommissioning Funding Plan Submitted in Accordance with 10 CFR 72.30(b) and (C) for Oyster Creek ISFSI ML19295G4922019-10-24024 October 2019 Summary of the October 3, 2019, Public Meeting Near the Oyster Creek Nuclear Generating Station Regarding the Establishment and Operation of Community Advisory Boards ML18205A5502018-08-0606 August 2018 Memorandum to File - Public Feedback to 7/17/18 Public Meeting in Forked River, Nj, to Receive Public Comments on Post-Shutdown Decommissioning Activities Report and Site-Specific Decommissioning Cost Estimate ML18102A1072018-04-18018 April 2018 Annual Assessment Meeting Summary 2018 ML17151A2702017-05-31031 May 2017 Annual Assess Meeting Summary and Attendees ML17142A2382017-05-25025 May 2017 OEDO-17-00280 - Briefing Package for Drop-In Visit on June 9, 2017, by Senior Management of Exelon Generation Company, LLC with Chairman Svinicki, Commissioner Baran, and Commissioner Burns ML17132A2242017-05-10010 May 2017 May 25, 2017, Oyster Creek Nuclear Generating Station Public Meeting Notice ML17075A0172017-03-16016 March 2017 Meeting Summary Memorandum - Regulatory Conference March 9, 2017 ML16221A6152016-08-19019 August 2016 Notice of Forthcoming Closed Meeting with Exelon Generation Company, LLC Regarding a Presubmittal Physical Security Plan Change for Decommissioning at the Oyster Creek Nuclear Generating Station ML16088A2052016-03-28028 March 2016 Enclosure 1 - (72.30 DFP Reviews to Be Completed 2015) - Memo T Bowers from s Ruffin, Technial Assistance Requests - Review 2015 Tri-Annual Decommissioning Funding Plans for Multiple Independent Spent Fuel Storage Installations ML16088A2042016-03-28028 March 2016 Memo T Bowers from s Ruffin, Technical Assistance Requests - Review 2015 Tri-Annual Decommissioning Funding Plans for Multiple Independent Spent Fuel Storage Installations W/ Encl 2 (Template) ML16075A3292016-03-16016 March 2016 OEDO-16-00165 - Briefing Package for Drop-In Visit on March 23, 2016, by Senior Management of Exelon Generation Company, LLC with the NRC Executive Director for Operations ML16035A0362016-02-0505 February 2016 February 3, 2016, Summary of Closed Meeting with the U.S. Nuclear Regulatory Commission and Exelon Generation Company, LLC, Regarding Security Plan Change for the Oyster Creek Nuclear Generating Station ML16015A1402016-01-27027 January 2016 Forthcoming Closed Meeting with the U.S. Nuclear Regulatory Commission and Exelon Generation Company, LLC Regarding a Physical Security Plan Change for the Oyster Creek Nuclear Generating Station ML15239A4622015-08-28028 August 2015 54p PSP Rev 13 Close-out Letter 8-27-15 ML14220A5122014-09-0303 September 2014 Summary - Site Visit Regarding Physical Security License Amendment Request for Oyster Creek Nuclear Generating Station ML13309A0802013-12-11011 December 2013 Memorandum to File: Transcript for 10 CFR 2.206 Petition from Beyond Nuclear (Et Al) Regarding General Electric Mark I and Mark II Boiling-Water Reactors ML13199A5092013-09-18018 September 2013 Transmittal of Final Oyster Creek Nuclear Station Accident Sequence Precursor Analysis ML13240A2952013-09-10010 September 2013 Notice of Forthcoming Closed Meeting with the Nuclear Regulatory Commission and Exelon Generation Company, LLC Regarding a Pre-Submittal Physical Security License Amendment Request for Oyster Creek Nuclear Generating Station ML13190A3522013-07-10010 July 2013 Notice of Forthcoming Teleconference with Exelon Generation Company, LLC ML12348A6962012-12-17017 December 2012 1/3/2013 - Notice of Forthcoming Meeting with Exelon Generation Company, LLC, to Discuss Requests for Additional Information Regarding Exelon Physical Security Plans ML13196A2202012-06-0606 June 2012 Memo from B. Balsam, NRR and D. Logan, NRR to J. Susco, NRR on Summary of Section 7 Consultation Activities Related to the National Marine Fisheries Service'S Final Rule to List the Atlantic Sturgeon ML1208602902012-03-26026 March 2012 Notice of Forthcoming Public Meeting with Exelon Generation to Discuss Future Fleet Submittal Regarding Licensed Operator Eligibility Requirements ML11250A1712011-09-14014 September 2011 Notice of Forthcoming Meeting with Petitioner Requesting Action Under 10 CFR 2.206 Regarding Immediate Suspension of the Operating Licenses of General Electric (GE) Mark 1 Boiling Water Reactors (Bwrs) ML1118702612011-06-27027 June 2011 NRC Comments on Draft Licensee-Developed Exam (Operating) (Folder 2) ML11126A0962011-05-12012 May 2011 Notice of Meeting with Petitioner Requesting Action Under 10CFR2.206 Regarding Immediate Suspension of Operating Licenses of General Electric Mark 1 Boiling Water Reactors ML1109502212011-04-11011 April 2011 Electronic Transmission, Draft Request for Additional Information Regarding Review of Flaw Evaluation for Weld NG-E-007 ML1108402192011-04-0404 April 2011 Memorandum to File: Transcripts for 10 CFR 2.206 Petition Regarding Oyster Creek and Nine Mile Point, Unit No. 1 Peak Cladding Temperature and ECCS Performance ML1100502522011-02-0909 February 2011 Memo to Chairman Jaczko Fm R. W. Borchardt, EDO Initiatives for Improved Communication of Groundwater Incidents ML1035703292011-01-28028 January 2011 OMA Exemption, Fire Protection Input for Request for Exemption from Title 10 of the Code of Federal Regulations Part 50, Appendix R, Section Iii.G, Fire Protection of Safe Shutdown Capability (Phase 1) ML1032105082010-11-16016 November 2010 Units 1 & 2 - Electronic Transmission, Draft Request for Additional Information Regarding Request to Implement Emergency Action Level Scheme Change to NEI 99-01, Revision 5 ML1030905672010-11-0505 November 2010 Electronic Transmission, Draft Request for Additional Information Regarding License Amendment Request to Modify Required Actions for Inoperability of an Emergency Diesel Generator ML1026004432010-09-17017 September 2010 Closeout of Bulletin 2007-1 Security Officer Attentiveness, ML1025305792010-09-10010 September 2010 Electronic Transmission, Draft Request for Additional Information Regarding License Amendment Request to Modify Required Actions for Inoperability of an Emergency Diesel Generator ML1023005762010-08-18018 August 2010 Electronic Transmission, Draft Request for Additional Information Regarding License Amendment Request to Relocate Surveillance Frequencies to a Licensee Controlled Document ML1016806172010-06-18018 June 2010 Electronic Transmission, Draft Request for Additional Information Regarding License Amendment Request to Allow Temporary Changes to Secondary Containment Boundary During Shutdown Conditions ML1006401882010-03-0505 March 2010 Charter for the Groundwater Contamination Task Force ML1006100122010-03-0303 March 2010 Electronic Transmission, Draft Request for Additional Information Regarding License Amendment Request to Relocate Surveillance Frequencies to a Licensee Controlled Document ML0935705822010-01-19019 January 2010 Forthcoming Meeting Notice with Exelon Generation Company, LLC, to Discuss Oyster Creek Nuclear Generating Station, License Amendment Request Regarding Secondary Containment Operability ML0933805322009-12-0404 December 2009 Electronic Transmission, Draft Request for Additional Information Regarding Requested Exemptions to Fire Protection Requirements in 10 CFR 50, Appendix R ML0929311432009-12-0101 December 2009 Request for Additional Information on Request for Exception from 10 CFR 50, Appendix R, Section Iii. G, Fire Protection of Safe Shutdown Capability (Phase 1 & 2) at Oyster Creek Nuclear Generating Station ML0932210302009-11-18018 November 2009 Electronic Transmission, Draft RAI Regarding Response to Generic Letter 2008-01, Managing Gas Accumulation in Emergency Core Cooling, Decay Heat Removal, and Containment Spray System ML0928103632009-10-0808 October 2009 Notice of Meeting with Exelon Generation Company, LLC, to Discuss Oyster Creek Nuclear Generating Station and Exelon Fleet Lessons-Learned on Buried Piping Issues ML0926801972009-09-29029 September 2009 Notice of Pre-application Meeting to Discuss Egc'S Plants to Submit Power Uprate Requests for Various Units in Its Reactor Fleet ML0925803412009-09-17017 September 2009 Revised Notice of Meeting with Exelon Generation Company, LLC, to Discuss Oyster Creek Nuclear Generating Station, License Amendment Request Regarding Secondary Containment Operability ML0925801582009-09-15015 September 2009 Audit Plan for Review of the Addendum 3-Dimensional Finite Element Analysis for the Oyster Creek Nuclear Generating Station Containment Drywell Shell ML0925705572009-09-14014 September 2009 Draft Request for Additional Information Regarding Secondary Containment Operability ML0925402362009-09-11011 September 2009 Draft Request for Additional Information Regarding Secondary Containment Operability ML0921202792009-08-0404 August 2009 Draft Request for Additional Information Regarding Control Rod Drive Rod Notch Testing Frequency 2024-01-23
[Table view] Category:Project Plans and Schedules
MONTHYEARML0925801582009-09-15015 September 2009 Audit Plan for Review of the Addendum 3-Dimensional Finite Element Analysis for the Oyster Creek Nuclear Generating Station Containment Drywell Shell ML0914004682009-04-17017 April 2009 LRA Layout License Renewal Activities, Oyster Creek 1R22 ML0911807202009-03-20020 March 2009 Project Plan ML0911807192009-03-20020 March 2009 Project Plan ML0911807182009-03-20020 March 2009 Project Plan ML0912000222009-01-12012 January 2009 E-mail from D. Tifft of USNRC to R. Conte of USNRC, Regarding Oyster Creek 71003 Project Plan ML0914703662008-10-14014 October 2008 Project Plan Oc Lr Outage Inspection ML0914007032008-09-23023 September 2008 LRA Layout License Renewal Activities ML0914005382008-08-27027 August 2008 E-mail from P. Tamburro of Exelon Corp. to J. Richmond of USNRC, Regarding Oyster Creek 1R22 Milestone Schedule ML0914004672008-08-26026 August 2008 Lfv Summary Schedule Management Summary, Oyster Creek 1R22, 10/24/2008 Through 11/17/2008 ML0914005372008-08-18018 August 2008 E-mail from P. Tamburro of Exelon Corp. to J. Richmond of USNRC, Regarding Oyster Creek Schedule ML0914007062008-08-0707 August 2008 LRC Layout License Renewal Activities ML0914005342008-07-0101 July 2008 E-mail from P. Tamburro of Exelon Corp. to J. Richmond of USNRC, Regarding Oyster Creek License Renewal Preliminary Schedule - October Refueling Outage ML0914004742008-06-26026 June 2008 Lfv Opening Layout, License Renewal Activities ML0914004652008-06-26026 June 2008 Lfv Opening Layout License Renewal Activities, Oyster Creek 1R22 2009-09-15
[Table view] |
Text
September 15, 2009 MEMORANDUM TO: File FROM: Allen L. Hiser, Jr., Senior Technical Advisor /RA/
Division of License Renewal Office of Nuclear Reactor Regulation
SUBJECT:
AUDIT PLAN FOR REVIEW OF THE ADDENDUM 3-DIMENSIONAL FINITE ELEMENT ANALYSIS FOR THE OYSTER CREEK NUCLEAR GENERATING STATION CONTAINMENT DRYWELL SHELL This Memorandum makes publicly available the audit plan for the staffs review of the addendum 3-dimensional finite element analysis for the Oyster Creek Nuclear Generating Station containment drywell shell (see enclosure).
Docket No. 50-219
Enclosure:
As stated cc w/encl: See next page
September 15, 2009 MEMORANDUM TO: File FROM: Allen L. Hiser, Jr., Senior Technical Advisor /RA/
Division of License Renewal Office of Nuclear Reactor Regulation
SUBJECT:
AUDIT PLAN FOR REVIEW OF THE ADDENDUM 3-DIMENSIONAL FINITE ELEMENT ANALYSIS FOR THE OYSTER CREEK NUCLEAR GENERATING STATION CONTAINMENT DRYWELL SHELL This Memorandum makes publicly available the audit plan for the staffs review of the addendum 3-dimensional finite element analysis for the Oyster Creek Nuclear Generating Station containment drywell shell (see enclosure).
Docket No. 50-219
Enclosure:
As stated cc w/encl: See next page DISTRIBUTION: See next page ADAMS Accession No. ML092580158 OFFICE LA:DLR SL:DLR BC:RPB1:DLR SL:DLR NAME SFigueroa AHiser DPelton AHiser DATE 09/15/09 09/15/09 09/15/09 09/15/09
OFFICIAL RECORD COPY Memorandum to File from A. Hiser, dated September 15, 2009 DISTRIBUTION:
SUBJECT:
AUDIT PLAN FOR REVIEW OF THE ADDENDUM 3-DIMENSIONAL FINITE ELEMENT ANALYSIS FOR THE OYSTER CREEK NUCLEAR GENERATING STATION CONTAINMENT DRYWELL SHELL HARD COPY:
DLR RF E-MAIL:
PUBLIC AHiser DPelton RidsNrrDlr RidsNrrDlrRpb1 RidsNrrDlrRpb2 RidsNrrDlrRer1 RidsNrrDlrRer2 RidsNrrDlrRerb RidsNrrDciCvib RidsNrrDciCpnb RidsNrrDraAfpb RidsNrrDeEmcb RidsNrrDeEeeb RidsNrrDssSrxb RidsNrrDssSbpb RidsNrrDssScvb RidsOgcMailCenter RidsOpaMailResource LRegner DTifft, RI NMcNamara, RI DScrenci, RI RConte, RI BHarris, OGC
Oyster Creek Nuclear Generating Station cc:
Site Vice President - Oyster Creek Director - Licensing and Regulatory Affairs Nuclear Generating Station AmerGen Energy Company, LLC AmerGen Energy Company, LLC Correspondence Control P.O. Box 388 P.O. Box 160 Forked River, NJ 08731 Kennett Square, PA 19348 Senior Vice President- Operations Support Manager Licensing - Oyster Creek AmerGen Energy Company, LLC Exelon Generation Company, LLC 4300 Winfield Road Correspondence Control Warrenville, IL 60555 P.O. Box 160 Kennett Square, PA 19348 Kathryn M. Sutton, Esquire Morgan, Lewis, & Bockius LLP Ron Bellamy, Region I 1111 Pennsylvania Avenue, NW U.S. Nuclear Regulatory Commission Washington, DC 20004 475 Allendale Road King of Prussia, PA 19406-1415 Patrick Mulligan, Chief Bureau of Nuclear Engineering Correspondence Control Desk New Jersey Department of AmerGen Energy Company, LLC Environmental Protection 200 Exelon Way, KSA 1-N-1 25 Arctic Parkway Kennett Square, PA 19348 Ewing, NJ 08638 Plant Manager Vice President - Licensing and Oyster Creek Nuclear Generating Station Regulatory Affairs AmerGen Energy Company, LLC AmerGen Energy Company, LLC P.O. Box 388 4300 Winfield Road Forked River, NJ 08731 Warrenville, IL 60555 Associate General Counsel Regional Administrator, Region I Exelon Generation Company, LLC U.S. Nuclear Regulatory Commission 4300 Winfield Road 475 Allendale Road Warrenville, IL 60555 King of Prussia, PA 19406-1415 Chief Operating Officer (COO)
Mayor of Lacey Township AmerGen Energy Company, LLC 818 West Lacey Road 4300 Winfield Road Forked River, NJ 08731 Warrenville, IL 60555 Manager Regulatory Assurance Senior Vice President - Mid-Atlantic Oyster Creek Generating Station Operations AmerGen Energy Company, LLC AmerGen Energy Company, LLC P.O. Box 388 200 Exelon Way, KSA 3-N Forked River, NJ 08731 Kennett Square, PA 19348 Senior Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 445 Forked River, NJ 08731
Audit Plan Review of the Addendum 3-Dimensional Finite Element Analysis for the Containment Drywell Shell Oyster Creek Nuclear Generating Station September 18, 2009
=
Background===
On January 22, 2009, Exelon Nuclear submitted the results of a 3-dimensional finite element analysis (3-D FEA) using modern methods to determine the margin of the containment drywell shell of Oyster Creek Nuclear Generating Station, as compared to the requirements of the American Society of Mechanical Engineers (ASME) Code. On September 9, 2009, Exelon Nuclear submitted an addendum to the January 22 submittal, incorporating results from an updated analysis which modifies two items related to an analytical assumption. The September 9 letter indicates that Exelon is providing this information to ensure the NRC staff and the Advisory Committee on Reactor Safeguards (ACRS) have the latest relevant information.
Audit Bases The staff will perform an audit of the calculations used to produce the results described in the September 9, 2009, addendum to the 3-D FEA of the Oyster Creek drywell shell.
Audit Scope The audit will focus on an assessment of the 3-D FEA described in the addendum dated September 9, 2009. The staff will review the September 2009 addendum calculations and supporting documentation to ensure that the analysis was based on realistic, but conservatively biased assumptions and that it was conducted using good engineering practices and judgment.
Necessary Information and Materials The staff will review the calculations, including modeling and simplifying assumptions, and any documents used to develop or support the calculations.
Team Assignments Organization Name Function NRC/NRR/DLR Allen Hiser Project Team Leader NRC/NRR/DLR/RER2 Hans Ashar Reviewer NRC/NRR/DE Kamal Manoly Reviewer Audit Logistics September 18, 2009
- Entrance briefing at 10:00 AM
- Begin review at 10:15 AM
- Exit briefing at 3:00 PM Exelon Corporation 101 Constitution Avenue, NW Suite 400 East Washington, DC 20001
Deliverables An audit summary report shall be placed on the docket by October 15, 2009.
References January 22, 2009 Results of Three-Dimensional Structural Analysis of the Oyster Creek Drywell Shell, Associated with AmerGens License Renewal Application (TAC No. MC7624)
September 9, 2009 Updated Information Regarding the Results of the Structural Analysis of the Oyster Creek Drywell Shell, Performed in Support of License Renewal