ML080880100

From kanterella
Jump to navigation Jump to search
Slides - NRC Annual Performance Assessment of Millstone, 2007 Reactor Oversight Process
ML080880100
Person / Time
Site: Millstone  
Issue date: 04/02/2008
From: Norris B
NRC/RGN-I/DRP/PB5
To:
Powell R, RI/DRP/610-337-6967
References
Download: ML080880100 (22)


Text

NRC Annual Performance Assessment of Millstone 2007 Reactor Oversight Process

2 Purpose of Todays Meeting

  • Discuss Millstones Plant Performance for CY 2007
  • Provide Dominion the opportunity to respond to the NRCs Annual Performance Assessment and to identify new or existing programs to continue to improve performance
  • Provide stakeholders the opportunity to engage the NRC staff on plant performance issues and our role in ensuring safe plant operations

3 Agenda

  • Introduction
  • NRC Organization and Performance Goals
  • Reactor Oversight Process (ROP)
  • National Summary of Plant Performance
  • Millstones Plant Performance Assessment
  • Dominion Response and Remarks
  • NRC Closing Remarks
  • Break
  • NRC available to address public questions

4 Region I Organization Samuel J. Collins Regional Administrator Marc L. Dapas Deputy Regional Administrator David C. Lew Director Division of Reactor Projects James W. Clifford Deputy Director Marsha K. Gamberoni Director Division of Reactor Safety Darrell J. Roberts Deputy Director Regional Specialists Raymond J. Powell Branch Chief Project Engineers Barry S. Norris - Senior PE Nicole S. Sieller - PE Millstone Resident Inspectors Steve W. Shaffer - Senior RI Jamie C. Benjamin - RI James A. Krafty - RI

5 NRC Strategic Plan Goals 3/4 Safety: Ensure adequate protection of public health and safety and the environment 3/4 Security: Ensure adequate protection in the secure use and management of radioactive materials

6 Reactor Oversight Process 3 Strategic Areas & 7 Cornerstones Reactor Safety Radiation Safety Safeguards Initiating Events Mitigating Systems Barrier Integrity Emergency Preparedness Occupational Radiation Safety Public Radiation Safety Physical Protection

7 Reactor Oversight Process S afety C o rnerstones B aseline In sp ectio n R esu lts S ig nificance Threshold Actio n M atrix S ig nificance Threshold P erform an ce Indicator R esu lts R egulato ry R espo nse S trategic P erform ance Areas S afety C o rnerstones B aseline In sp ectio n R esu lts S ig nificance Threshold Actio n M atrix S ig nificance Threshold P erform an ce Indicator R esu lts R egulato ry R espo nse S trategic P erform ance Areas

8 Typical Baseline Inspection Areas

  • Equipment Alignment
  • Maintenance
  • Fire Protection
  • Operator Response
  • Radiological Environmental Monitoring
  • Worker Radiation Protection
  • Corrective Action Program
  • Corrective Action Case Reviews

9 NRC Performance Indicators Initiating Events PIs Unplanned Scrams Unplanned Scrams with Complications Unplanned Power Changes Mitigating Systems PIs Emergency AC Power System High Pressure Injection System Residual Heat Removal System Cooling Water Support Systems Safety System Functional Failures Barrier Integrity PIs Reactor Coolant System Specific Activity Reactor Coolant System Leakage Emergency Planning PIs Drill / Exercise Performance Emergency Response Organization Participation Alert and Notification System Radiation Protection PIs Occupational Exposure Control Effectiveness RETS / ODCM Radiological Effluent Security PIs are not Publicly Available

10 Significance Threshold Performance Indicators 3/4 Green Baseline Inspection 3/4 White Requires increased NRC oversight 3/4 Yellow Requires more NRC oversight 3/4 Red Requires most NRC oversight Inspection Findings 3/4 Green Very low safety issue 3/4 White Low to moderate safety issue 3/4 Yellow Substantial safety issue 3/4 Red High safety issue

11 Action Matrix Concept Licensee

Response

Regulatory

Response

Degraded Cornerstone Multiple/Rep.

Degraded Cornerstone Unacceptable Performance

  • Increasing Safety Significance
  • Increasing NRC Inspection Efforts
  • Increasing NRC/Licensee Management Involvement
  • Increasing Regulatory Actions

12 National Summary of Plant Performance (at end of 2007)

Licensee Response 87 Regulatory Response 8

Degraded Cornerstone 8

Multiple/Repetitive Degraded Cornerstone 1

Unacceptable 0

Total 104

13 National Summary of Plant Performance (at end of 2007)

Performance Indicator Results 3/4 Green 1954 3/4 White 8

3/4 Yellow 2

3/4 Red 0

Total Inspection Findings 3/4 Green 918 3/4 White 9

3/4 Yellow 2

3/4 Red 0

14 NRC Inspection Activities at Millstone (for CY 2007)

  • 6680 hours0.0773 days <br />1.856 hours <br />0.011 weeks <br />0.00254 months <br /> of inspection and related activities
  • 3 resident inspectors on-site
  • 17 regional inspections
  • 4 major team inspections:

Licensed Operator Requalification Physical Security Fire Protection Modifications / 50.59

15 Millstone PIs / Findings (CY 2007)

  • All Green Performance Indicators
  • 14 Green inspection findings

16 Example NRC Inspection Findings

  • Green - Failure to properly implement a safety-related surveillance procedure resulted in a Safety Injection Accumulator being inoperable
  • Green - Inadequate work procedure for a Unit 2 Charging pump resulted in pump failure

17 NRC Annual Assessment Summary Millstone

  • Dominion operated the plant safely and in a manner that preserved public health and safety and protected the environment
  • Millstone remained in the Licensee Response column of the NRCs Action Matrix for all four quarters of 2007
  • All cornerstone objectives were fully met
  • NRC plans baseline inspections at Millstone for the remainder of CY 2008

18 Licensee Response and Remarks Mr. J. Alan Price Site Vice President Dominion Resources

19 Contacting the NRC

  • Report an emergency:

3/4(301) 816-5100 (call collect)

  • Report a safety concern:

3/4(800) 695-7403 3/4Allegation@nrc.gov

  • General information or questions:

3/4www.nrc.gov 3/4Select News and Information for a link to email Public Affairs

20 NRC Representatives

  • James W. Clifford, Deputy Division Director, DRP 3/4 610-337-5080
  • Raymond J. Powell, Branch Chief 3/4 610-337-6967
  • Steve W. Shaffer, Senior Resident Inspector 3/4 860-447-3170
  • Jamie C. Benjamin, Resident Inspector 3/4 860-447-3170
  • James A. Krafty, Resident Inspector 3/4 860-447-3170
  • Barry S. Norris, Senior Project Engineer 3/4 610-337-5111

21 Reference Sources 3/4 Reactor Oversight Process http://www.nrc.gov/NRR/OVERSIGHT/ASSESS/index.html 3/4 Public Electronic Reading Room http://www.nrc.gov/reading-rm.html 3/4 Public Document Room 1-800-397-4209 (Toll Free)

End of the Presentation Nuclear Regulatory Commission Region I King of Prussia, Pennsylvania April 17, 2008