1 Update on Generic Safety Issue 191 Plant Audits Presented by:
Michael Scott Office of Nuclear Reactor Regulation Presented to: Public Meeting on GSI-191 October 24, 2007
2 Purpose of Presentation Briefly summarize audit process Discuss results to date Discuss future plans
3 Audit Purposes
- Increase effectiveness and efficiency of NRC and industry efforts to address Generic Letter (GL) 2004-02 by:
- promoting more timely issue resolution
- promoting uniform treatment of issues
- identifying issues early to promote consistent responses and stable regulatory environment
4 Selection Criteria and Audit Plans
- Approximately 10 audits to be conducted
- all scheduled, in progress, or complete (status follows)
- Emphasis is on adequacy of design and supporting analyses
5 GSI-191 Audits January 2008 St Lucie December 2007 Indian Point In progress October 2007 Salem In progress July 2007 North Anna Nearly complete June 2007 Waterford Complete March 2007 Oconee Complete January 2007 Millstone Complete October 2006 Prairie Island Complete Aug/Sep 2006 San Onofre Complete March 2006 Watts Bar Report Status Site Visit Plant
6 Process Documents requested in advance Snapshot of completion status Usually 1 week or less onsite, 7-8 auditors Usually no requests for additional information (RAIs)
Product is an audit report Draft open items to be visible soon after audit as publicly available memo - see PWR Sump Performance web page Open items to be addressed by licensees in 12/31/07 GL 2004-02 responses (or by supplement, for last audits)
Reports to be public (after affected licensees and contractors verify nonproprietary) on NRCs sump website Note: Inspection of installation of modifications at each plant not within scope (TI-2515/166)
7 Audit Results
- As expected, a number of open items identified in each audit to date
- Recent audits indicate affected licensees aware of issues at other plants and addressing them
- List of recent example issues follows - not all-inclusive
8 Issues Identified (1 or more plants)
- Chemical effects still not addressed
- In-vessel and ex-vessel downstream effects not fully addressed
- Nonprototypical debris preparation for head loss testing
- Weak justification for choice of surrogate debris
- LPSI pump failure to stop
9 Issues Identified (Continued)
- No evaluation of potential for vapor flashing
- Some upstream water holdup mechanisms not considered
- Head loss scaling for parameters other than temperature
- Inadequate basis for assumptions regarding time-dependent debris arrival
10 What do results show?
- Progress has been made
- Some areas not demonstrated to be close to successful completion
- Licensee Generic Letter 2004-02 submittals need to provide confidence issues such as those noted have been addressed
- Staff plans limited-scope audits in 2008 to address chemical and downstream effects