License Renewal Application, Amendment 14, Draft SER Open Item Responses
ML073180494
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 11/05/2007
From: Peter Dietrich
Entergy Nuclear Northeast, Entergy Nuclear Operations
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
JAFP-07-0125
Download: ML073180494 (17)


Text

SEntergy Entergy Nuclear Northeast Entergy Nuclear Operations, Inc.

James A. Fitzpatrick NPP This Document Contains Proprietary Information P.O. Box 110 Withhold from Public Disclosure Per 10 CFR 2.390 Lycoming, NY 13093 Tel 315 349 6024 Fax 315 349 6480 November 5, 2007 JAFP-07-0125 Pete Dietrich Site Vice President - JAF U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001

REFERENCES:

1. Letter, Entergy to USNRC, "James A. FitzPatrick Nuclear Power Plant, Docket No. 50-333, License No. DPR-59, License Renewal Application," JAFP-06-0109, dated July 31, 2006
2. Letter, USNRC to JAFNPP, "Safety Evaluation Report with Open Items Related to the License Renewal of James A. FitzPatrick Nuclear Power Plant)," dated July 31, 2007
3. Letter, Entergy to USNRC, "James A. FitzPatrick Nuclear Power Plant, Docket No. 50-333, License No. DPR-59, License Renewal Application, Amendment 12," JAFP-07-079, dated June 20, 2007
4. Letter, Entergy to USNRC, "James A. FitzPatrick Nuclear Power Plant, Docket No. 50-333, License No. DPR-59, License Renewal Application, Amendment 13," JAFP-07-100, dated August 14, 2007

SUBJECT:

Entergy Nuclear Operations, Inc.

James A. FitzPatrick Nuclear Power Plant Docket No. 50-333, License No. DPR-59 License Renewal Application. Amendment 14

Dear Sir or Madam:

On July 31, 2006, Entergy Nuclear Operations, Inc. submitted the License Renewal Application (LRA) for the James A. FitzPatrick Nuclear Power Plant (JAFNPP) as indicated by Reference 1. contains a response to the Open Items related to reactor vessel fluence provided in section 1.5 of Reference 2. Attachment 2 provides the LRA changes associated with the updated fluence calculation. Attachment 3 provides the fluence calculation. In accordance with 10 CFR 2.390 (b)(1), an affidavit attesting to the proprietary nature of the calculation and requesting withholding from public disclosure is included with attachment 3. contains the same information with the proprietary information removed, and is provided for public disclosure. Attachment 5 supplements information previously provided in response to RAI 4.2.6-1 in Reference 3. Attachment 6 supplements information previously provided in response to RAI 4.3.3-1 in Reference 4, this information also addresses the Open Item related to section 4.3.3 provided in section 1.5 of Reference 2.

When separated from Attachment 3 this document becomes de-controlled.

.. n

This Document Contains Proprietary Information Withhold from Public Disclosure Per 10 CFR 2.390 November 5, 2007 JAFP-07-0125 Page 2 of 3 Should you have any questions concerning this submittal, please contact Mr. Jim Costedio at (315) 349-6358.

I declare, under peEakjy of perjury that the foregoing is true and correct. Executed on the PD/cf Attachments:

1) Draft SER Open Item Responses
2) LRA Changes
3) Fluence Calculation (Proprietary Version)
4) Fluence Calculation (Non Proprietary Version)
5) Axial Weld Analysis Clarification
6) Supplemental Information for RAI 4.3.3-1 cc:

Mr. N.B. (Tommy) Le, Senior Project Manager License Renewal Branch B Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Mail Stop 0-11-F1 Washington, DC 20555 Mr. Samuel J. Collins, Administrator Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 NRC Resident Inspector U. S. Nuclear Regulatory Commission James A. FitzPatrick Nuclear Power Plant P.O. Box 136 Lycoming, NY 13093 When separated from Attachment 3 this document becomes de-controlled.

This Document Contains Proprietary Information Withhold from Public Disclosure Per 10 CFR 2.390 November 5, 2007 JAFP-07-0125 Page 3 of 3 Mr. John P. Boska, Project Manager Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Mail Stop O-8-C2 Washington, DC 20555 cc: without Attachment 3 Mr. Paul Eddy New York State Department of Public Service 3 Empire State Plaza, 10 th Floor Albany, NY 12223 Mr. Paul Tonko, President NYSERDA 17 Columbia Circle Albany, NY 12203-6399 When separated from Attachment 3 this document becomes de-controlled.

JAFP-07-0125 Docket No. 50-333 James A. FitzPatrick Nuclear Power Plant License Renewal Application - Amendment 14 Draft SER Open Item Responses:

014.2.1-1 sOl 4.2.2-1 sOl 4.2.3-1 sl 4.2.4-1 sl 4.2.5-1 sl 4.2.6-1 sOl B.1.24-3

Draft SER Open Item Responses 01 4.2.1-1 (SER Section 4.2.1 - Reactor Vessel Fluence)

The staff reviewed GE-NE-B1 100732-01 report on analysis of the 1200 capsule removed at 13.4 effective full power years (EFPYs) of operation submitted by the applicant to confirm if calculation of fluence values are in accordance with the guidance of RG 1.190, "Calculational and Dosimetry Methods for Determining Pressure Vessel Neutron Fluence."

The staff's review of this report found several discrepancies with the RG 1.190 guidance.

For determining pressure vessel neutron fluence, the staff finds the projected fluence values unacceptable. The applicant has stated that it will submit a new fluence calculation by a contractor to the staff for review when complete.

Response

JAFNPP contracted Transware Enterprises, Inc to perform a fluence evaluation in accordance with guidelines in Regulatory Guide 1.190, "Calculational and Dosimetry Methods for Determining Pressure Vessel Neutron Fluence". In compliance with the guidelines, comparisons to flux wire measurements were performed to determine the accuracy of the fluence model and an uncertainty analysis was performed to determine if a statistical bias exists in the model. It was determined that the JAF fluence model does not have a statistical bias and that the results presented in the report are suitable for use in evaluating the effects of embrittlement on RPV material as specified in I OCFR50 Appendix G. The fluence values were calculated using the RAMA fluence method which the NRC has found is in accordance with RG 1.190. For additional information, refer to the proprietary calculation included in Attachment 3.

The 54 EFPY fluence evaluation results using the RAMA fluence method for RPV beltline plates and welds compared to fluence values presented in Section 4.2.1 of the LRA are shown below.

Location Transware 4 T fluence, n/cm2 LRA 14T fluence, n/cm2 Lower shell plates 1.71E+18 1.85E+ 18 Lower intermediate shell 2.1 OE+18 2.21E+18 plates Lower shell axial welds 1.48E+18 1.74E+ 18 Lower intermediate shell 1.20E+ 18 1.29E+ 18 axial welds Lower shell to lower 1.71E+18 1.85E+18 intermediate shell circumferential welds As can be seen, the 54 EFPY 1/4t fluence values predicted using the RAMA fluence method are less than the values in the LRA. As a result, the following conclusions described in Section 4.2 remain valid.

CvUSE values for vessel plates are projected to remain well above 50 ft-lbs.

All equivalent margin analyses for reactor vessel welds show reductions in CvUSE below the BWRVIP-74-A reductions.

All projected values for ART are well below the 200°F suggested in RG 1.99.

Page 1 of 3 JAFP-07-0125

Draft SER Open Item Responses sOl 4.2.2-1: (SER Section 4.2.2 - Pressure-Temperature Limits)

The staff's review of P-T limits was based on the applicant's fluence values in LRA Section 4.2.1. Until 01 4.2.1-1 is resolved, the staff cannot close its review of this TLAA.

Response

JAFNPP will use the license amendment process to update P-T curves. As shown above, the new fluence values are less than the values used in the LRA and as such will not have a negative effect on updated P-T curves.

sOl 4.2.3-1: (SER Section 4.2.3 - Charpy Upper-Shelf Energy)

The staff's review was based on the fluence values provided by the applicant in LRA Section 4.2.1. Until 01 4.2.1-1 is resolved, the staff cannot close its review of this TLAA.

Response

As shown above, the new fluence values are less than the values used in the LRA such that conclusions based on 54 EFPY projections for Charpy Upper-Shelf Energy described in the LRA remain valid.

sOl 4.2.4-1: (SER Section 4.2.4 -.Adjusted Reference Temperature)

The staff's review was based on the applicant's fluence values in LRA Section 4.2.1.

Until 01 4.2.1-1 is resolved, the staff cannot close its review of this TLAA.

Response

As shown above, the new fluence values are less than the values used in the LRA such that conclusions based on 54 EFPY projections for adjusted reference temperature described in the LRA remain valid.

sOl 4.2.5-1: (SER Section 4.2.5 - Reactor Vessel Circumferential Weld Inspection Relief)

The staff's review was based on the applicant's fluence values in LRA Section 4.2.1.

Until 01 4.2.1-1 is resolved, the staff cannot close its review of this TLAA.

Response

As described in Section 4.2.5 of the LRA, surface rather than 1/4t fluence is used to calculate RTndt for circumferential weld inspection relief The Transware 54 EFPY maximum circumferential weld surface fluence is 2.53E+18 n/cm2 compared to 2.71E+18 n/cm2 provided in Table 2.4-1 of the LRA. Therefore, conclusions based on the 54 EFPY evaluation for circumferential weld inspection relief as described in the LRA remain valid.

Page 2 of 3 JAFP-07-0125

Draft SER Open Item Responses sOl 4.2.6-1: (See SER Section 4.2.6 - Reactor Vessel Axial Weld Failure Probability)

The staff's review was based on the applicant's fluence values in LRA Section 4.2.1.

Until 01 4.2.1-1 is resolved, the staff cannot close its review of this TLAA.

Response

As described in Section 4.2.6 of the LRA, surface rather than 1/4t fluence is used to calculate RTndt for axial weld failure probability. The Transware 54 EFPY maximum axial weld surface fluence is 2.34E18 n/cm2 compared to 2.55E18 n/cm2 provided in Table 4.2-5 of the LRA. Therefore, conclusions based on the 54 EFPY evaluation for axial weld failure probability as described in the LRA remain valid.

sOl B.1.24-3: (See SER Section 3.0.3.2.16 - Reactor Vessel Surveillance Program)

On the basis of the staff review for LRA item B.1.24 discussed in SER Section 3.0, the staff finds, pending the resolution of the Ols noted above, that the applicant has demonstrated that the effects of aging due to loss of fracture toughness of the reactor pressure vessel beltline region will be adequately managed, so that the intended functions will be maintained consistent with the CLB for the period of extended operation, as required by 10 CFR 54.21(a)(3).

Response

As shown above, the various Ols associated with neutron fluence are resolved. The Reactor Vessel -Surveillance Program will continue to adequately manage loss of fracture toughness of the reactor pressure vessel beltline region Page 3 of 3 JAFP-07-0125

JAFP-07-0125 Docket No. 50-333 James A. FitzPatrick Nuclear Power Plant License Renewal Application - Amendment 14 LRA Changes

LRA Changes (additions = underlined, deletions = strikethrough)

Section 4.2.1. Reactor Vessel Fluence The 32 EFPY fluence is based on a General Electric analysis of measured fluence from the JAFNPP surveillance flux wires which allows for 5% power uprate completed after flux wire removal. These flu',Pence valuor,' were f'arther extrapolated to 5U EFPY to obtain peak plate sD flunprce with 1t1 T Valuen di ofd ue i ng RG 1.o 9 feoermua aind cnserporative wall thicknesses.

Neutron fluence was proiected to the end of the p~eriod of extended operation (54 EFPY) usinq the RAMA fluence method with % T values derived using RG 1.99 formula.

The following fluence values are used throughout the remainder of Section 4.2.

Location Surface fluence, n/cm 1/4 T fluence, n/cm*

Lower shell 2.71 E+!9 1.85E+1 2.53E+18 1.71 E+1 8 Lower intermediate shell 3.05=E+8 2.21 E+814 3.11 E+18 2.10E+18 Lower shell axial welds

2.55E+!8 I.74".E4+

2.34E+18 1.48E+18 Lower intermediate shell axial welds 1-.9E-+-1-84 1.75E+18 1.20E+18 Lower shell to lower intermediate 2.7! E+18 4.95F+48 shell circumferential welds 2.53E+18 1.71 E+18 Page 1 of 6 JAFP-07-0125

LRA Changes Section 4.2.3 Charmv Upper-Shelf Enerqv Table 4.2-1 JAFNPP Charpy Upper-Shelf Energy Equivalent Margin Analysis Surveillance Weld Surveillance Weld % Cu Surveillance Weld Fluence (n/cm 2)

Surveillance Weld Measured Decrease (%)

RG 1.99 Predicted Decrease (%)

Ratio of Measured to Predicted Limiting Extrapolated Weld (1-240)

Beltline Weld % Cu 54 EFPY 1/4 T fluence (n/cm2)

RG 1.99 Predicted Decrease (%)

Adjusted % Decrease (%)

Limiting % Decrease (%)

Acceptable 0.29 5.OOE+17 Unknown 22 1.000 0.337 1.710E+18 31.46 31.40 31.40 39.0 Yes Page 2 of 6 JAFP-07-0125

LRA Changes Table 4.2-2 JAFNPP Charpy Upper-Shelf Energy Data for 54 Effective Full-Power Years (EFPY)

Material Description 54 EFPY Projection Reactor Vessel Beltline Material Material Unirradiated 114 T

% Drop in USE Region Location Type Identification Heat #

%Cu CvUSE fluence USE (114 T)

(1019 n/cm2)

Lowershell A533B 157 C3394-1 0.11 85.6 04851 4-.4 7 0.1710 13.2 74.3 Lower shell A533B 158 C3376-2 0.13 77.4 Q-1-854 1448 66" 0.1710 14.5 66.2 Lower shell A533B 159 C3103-2 0.14 82.6 0 1851-

-54 64 0.1710 15.1 70.1 Lower intermediate shell A533B 160 C3368-1 0.12 67.0 Q 21 0 4.-4

--7-.

0.2100 14.5 57.3 Lower intermediate shell A533B 161 C3301-1 0.18 82.3 0-2:2 1-Q Q 6648 0.2100 18.7 66.9 Lower intermediate shell A533B 162 C3278-2 0.11 84.3 0.2:21 44,9 72,5 0.2100 13.8 72.6 Lower int. shell axial welds Linde 1092 608 13253 &

0.210 Not available 0-2:20 24 42 EMA 1-233A/B/C 12008 0.1200 21.18 Lower shell axial welds Linde 1092 609 27204 &

0.219 Not available 0851-24.08 EMA 2-233A/B/C 12008 0.1480 22.84 Circ weld Linde 1092 610 305414 0.337 Not available 0-1-851 21 9 EMA 1-240 0.1710 31.40 Page 3 of 6 JAFP-07-0125

LRA Changes Section 4.2.4 Adjusted Reference Temperature Table 4.2-3 JAFNPP RTNDT Data for 54 Effective Full-Power Years (EFPY)

Initial Material Description 54 EFPY Extrapolation Reactor Vessel MInitial 1/4 T ReacyMaterial Material InR fluence Fluence ARTNDT Margin ARTNDT Beltl ion Type Identifier Factor TNDT Ou (1019 Factor (Deg F) aA (Deg F)

(Deg F)

Location HacCri(OF) n/cm2)

Lower shell A533B 157 C3394-1 0.11 0.560 73.60

-10.0 0

04854 Q 554 40,6 17.0 34.0 64-4

_ 1 0.1710 0.533 39.2 63.2 Lower shell A533B 158 C3376-2 0.13 0.600 91.00 24.0 0

0-185 Q 551 -54 17.0 34.0 1084 0.1710 0.533 48.5 106.5 Lower shell A533B 159 C3103-2 0.14 0.570 98.65

-2.0 0

04851 0.551

,A544 17.0 34.0 86,4 0.1710 0.533 52.5 84.5 Lower A533B 160 C3368-1 0.12 0.500 81.00

-10.0 0

0:2=4 0594 48-&-

17.0 34.0 72-4 intermediate 0.2100 0.581 47.1 71.1 shell Lower A533B 161 C3301-1 0.18 0.570 131.15

-18.0 0

Q2:21 0 Q594 77-9 17.0 34.0 93_9 intermediate 0.2100 0.581 76.2 92.2 shell Lower A533B 162 C3278-2 0.11 0.600 29.40

-10.0 0

0 0 594 1-7-4 0-9 40 26*

intermediate 0.2100 0.581 17.1 8.5 17.1 24.2 shell I

I I

I III_

I Lower int shell Linde 608 13253 &

0.210 0.873 208.68

-50 0

0_--0 0-594 1-22 9 28.0 56.0 1-29 9 axial welds 1092 12008 0.1200 0.454 94.8 100.8 1-233A/B/C Lower shell Linde 609 27204&

0.219 0.996 231.06

-48 0

Q81 Q 551-1-27 28.0 56.0 1 axial welds 1092 12008 0.1480 0.500 115.5 123.5 2-233A/B/C I

I I

I I

I__II Circweld Linde 610 305414 0.337 0.609 209.11

-50 0 10 1 0.551 1 -15 28.0 56.0 1-240 1092 0.1710 0.533 111.4 1174 I-oW c-ro-it is t.-ako.n fo*r -v;xil

-nd azimuhal lod factors to reo-due oak fluoneo.

Page 4 of 6 JAFP'07-0125

LRA Changes Section 4.2.5 Reactor Vessel Circumferential Weld Inspection Relief Table 4.2-4 Effects of Irradiation on JAFNPP RPV Circumferential Weld Properties CEOG/32 EFPY JAFNPPI 32 CEOGI64 JAFNPP/ 54 Plant / Parameter Description Bounding EFPY Bounding EuPn EFPY Beltline Parameters Weld (1-240)

Bounding Circ Weld

___________Parameters nitial (unirradiated) reference 0

-50 0

-50 emperature (RTNDT), TF Neutron fluence at the end of the 2.00 x 101' 1.61 x 10To 4.00 x loll

2. 7! X IO requested relief period, n/cm 2 2.53 x 1018 Fluence factor (FF) (calculated per 0.569 0.519 0.746

ý0.644 RG1.99 based on fluence in previous 0.627 line)

Weld copper content, %

0.183 0.337 0.183 0'.337 Weld nickel content, %

0.704 0.609 0.704 0.609 Weld chemistry factor (CF) 172.2, 209.1 172.2 209.1 Fluence factor times chemistry factor 98.1 108.5 128.5 1-44 (FF x CF) 131.1 Margin (implied), OF 0.0 0.0 0.0 0.0 Increase in reference temperature 98.1 108.5 128.5 1-244 (ARTNDT), 'F (FF x CF + Margin) 131.1 Mean adjusted reference temperature 98.1 58.5 128.5 844

,(ART), OF (RTNDT + ARTNDT) 81.1 Section A.1.2 UFSAR Chapter 4 Changes Section 4.2.7 - Safety Evaluation (5th paragraph)

NRC Regulatory Guide 1.99, "Radiation Embrittlement of Reactor Vessel Materials",

Revision 2, May 1988, provides the basis for the reactor vessel material surveillance analysis which accounts for irradiation embrittlement effects in the reactor vessel core region, or beltline. The best estimate fluence for the peak locations in the lower shell and the lower intermediate shell after 54,32 effective full power years (EFPY) or 6040 years of power operation at 90i0% capacity factor are expected to be 2.52.71-.6!

x 1018 n/cm 2 and 3.1-.8-1-x 1j08 n/cm 2 respectively at the vessel ID.

Section A.2.2 Evaluation of Time-Limited Aging Analyses Section A.2.2.1.1 Reactor Vessel Fluence Calculated fluence is based on a time-limited assumption defined by the operating term.

As such, fluence is the time-limited assumption for the time-limited aging analyses that evaluate reactor vessel embrittlement.

The existing 32 EFPY fluence is based on a General Electric analysis of measured fluence from the JAFNPP surveillance flux wires (Reference A.2-8). These flue-Page 5 of 6 JAFP-07-0125

LRA Changes values wero further extrapolated to 54 EF=PY to obtain peak plate ID fluences with !A1 T-values derived using RG 1.09 foFrmula and conscriativc wall tlhiGknesse&-.

Neutron fluence was projected to the end of the period of extended operation (54 EFPY) using the RAMA fluence model.

Page 6 of 6 JAFP-07-0125

Affidavit I, Dean B. Jones, state as follows:

1. I am the President of TransWare Enterprises Inc. ("TWE") and have been delegated the function of reviewing the information described in paragraph (2) which is sought to be withheld, and have been authorized to apply for its withholding.
2. The information sought to be withheld is contained in the attachment TransWare Enterprises Inc. Document No. ENT-FLU-002-R-004, Revision 0, "Licensing Version of James A.

Fitzpatrick Reactor Pressure Vessel Fluence Evaluation at End of Cycle 17 and 54 EFPY,"

October 2007. TWE proprietary information is indicated by enclosing it in double brackets and highlighting the proprietary text in blue. Paragraph 3 of this affidavit provides the basis for the proprietary determination.

3. In making this application for withholding of proprietary information of which it is the owner or licensee, TWE relies upon the exemption of disclosure set forth in the Freedom of Information Act ("FOIA"), 5 USC Sec. 552(b)(4), and the Trade Secrets Act, 18 USC Sec. 1905, and the NRC regulations 1 OCFR9.17(a)(4) and 2.390(a)(4) for "trade secrets and commercial or financial information obtained from a person and privileged or confidential" (Exemption 4). The material for which exemption from disclosure is here sought is all "confidential and commercial information," and some portions also qualify under the narrower definition of "trade secret," within the meanings assigned to those terms for purposes of FOIA Exemption 4 in, respectively, Critical Mass Energy Project v. Nuclear Regulatory Commission, 975F2d871 (DC Cir. 1992), and Public Citizen Health Research Group v. FDA, 704F2d1280 (DC Cir. 1983).
4. Some examples of categories of information that fit into the definition of proprietary information are:
a. Information that discloses a process, method, or apparatus, including supporting data and analyses, where prevention of its use by TWE's competitors without license from TWE constitutes a competitive economic advantage over other companies;
b. Information which, if used by a competitor, could reduce the competitor's expenditure of resources or improve competitive position in the design, manufacture, shipment, installation, assurance of quality, or licensing of a similar product;
c. Information that reveals cost or price information, production capacities, budget levels, or commercial strategies of TWE, its customers, or its suppliers;
d. Information which reveals aspects of past, present, or future TWE customer-funded development plans and programs of potential commercial value to TWE;
e. Information which discloses patentable subject matter for which it may be desirable to obtain patent protection.

The information sought to be withheld is considered to be proprietary for the reasons set forth in paragraphs 4a. and 4b., above.

5. To address 10CFR2.390 (b)(4), the information sought to be withheld is being submitted to the NRC in confidence. The information is of a sort customarily held in confidence by TWE, and is in fact so held. Its initial designation as proprietary information, and the subsequent steps taken to prevent its unauthorized disclosure, are as set forth in paragraphs 6 and 7 following. The information sought to be withheld has, to the best of my knowledge and belief, consistently been held in confidence by TWE, no public disclosure has been made, and it is not available to public sources. All disclosures to third parties including any required transmittals to the NRC, have been made, or must be made, pursuant to regulatory provisions or proprietary agreements which provide for maintenance of the information in confidence.
6. Initial approval of proprietary treatment of a document is made by the manner of the originating component, the person most likely to be acquainted with the value and sensitivity of the information in relation to industry knowledge, or subject to the terms under which it was licensed to TWE. Access to such.documents within TWE is limited on a "need-to-know" basis.
7. The procedure for approval of external release of such a document typically requires review by the project manager, principal engineer, and by the Quality Assurance department for technical content, competitive effect, and the determination of the accuracy of the proprietary designation. Disclosures outside TWE are limited to regulatory bodies, customers, and potential customers and their agents, suppliers, and licensees, and others with a legitimate need for the information and then only in accordance with appropriate regulatory provisions or proprietary agreements.
8. The information identified in paragraph 2 is classified as proprietary because it contains details of TWE's methodologies for fluence and uncertainty analyses.

The development of the methods used in these analyses, along with the testing, development, and approval of the supporting methodology was achieved at a significant cost, on the order of several million dollars, to TWE or its licensor.

9. Public disclosure of the information sought to be withheld is likely to cause substantial harm to TWE's competitive position and foreclose or reduce the availability of profit-making opportunities. The methodologies for fluence and uncertainty analyses are part of TWE's nuclear engineering consulting base expertise and its commercial value extends beyond the original development cost. The value of the technology base goes beyond the extensive physical database and analytical methodology and includes development of the expertise to determine and apply the appropriate evaluation process. In addition, the technology base includes the value derived from providing analyses done with NRC-approved methods.

The research, development, engineering, analytical, and NRC review costs comprise a substantial investment of time and money by TWE or its licensor.

The precise value of the expertise to devise an evaluation process and apply the correct analytical methodology is difficult to quantify, but it is clearly substantial.

TWE's competitive advantage will be lost if its competitors are able to use the results of the TWE experience to normalize or verify their own process or if they are able to claim an equivalent understanding by demonstrating that they can arrive at the same or similar conclusions.

The value of this information to TWE would be lost, if the information were disclosed to the public. Making such information available to competitors without their having been required to undertake a similar expenditure of resources would unfairly provide competitors with a windfall and deprive TWE of the opportunity to exercise its competitive advantage to seek an adequate return on its large investment indeveloping and obtaining these very valuable analytical tools.

I declare under penalty of perjury that the foregoing affidavit and the matters stated therein are true and correct to the best of my knowledge, information, and belief.

Executed at Sycamore, Illinois, this 31st day of October, 2007.

Tra'-

ar EntDean B. Jones TransWare Enterprises Inc.