May 26, 2006 Tennessee Valley Authority ATTN: Mr. K. W. Singer Chief Nuclear Officer and Executive Vice President 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801
SUBJECT:
MEETING SUMMARIES: 1.) CATEGORY 1 PUBLIC MEETING WITH TENNESSEE VALLEY AUTHORITY (TVA) RE. BROWNS FERRY UNIT 1 RECOVERY STATUS; 2.) MEETING OF THE NRC RESTART PANEL FOR THE BROWNS FERRY UNIT 1 RECOVERY - DOCKET NO. 50-259
Dear Mr. Singer:
This refers to the public meeting conducted at your Browns Ferry Plant located near Athens, Alabama on May 2, 2006. The purpose of the meeting was to discuss the Browns Ferry Unit 1 (BF1) Restart Project Status. Discussions during this meeting included the following topics:
work activities accomplished to date, schedules for future milestones, TVA responses to challenges, and activities important to NRC oversight and inspections regarding Unit 1. contains a list of attendees. Enclosure 2 contains the NRC Browns Ferry Unit 1 Recovery Issues List which represents the NRCs understanding of the issues requiring NRC review prior to restart of Unit 1. The list is current as of May 1, 2006, the date of the meeting. contains the presentation material used by your staff to discuss the status of the Browns Ferry Unit 1 Restart Project. The meeting was informative and a beneficial exchange of information. Although it did not result in specific action items or decisions, both sides gained a better understanding of near term priorities. These periodic public meetings will continue throughout the recovery process.
In addition, on May 1, 2006, the Nuclear Regulatory Commission (NRC) held an internal meeting of the NRC Browns Ferry 1 (BF1) Restart Oversight Panel at the Browns Ferry site.
The purpose of this panel meeting was to discuss NRC perspectives on the BF1 restart project status, results from recent NRC inspections of BF1, status of notable licensing actions, and recent issues important to NRC oversight and inspections. The panel was established in accordance with NRC Inspection Manual Chapter (IMC), IMC 2509, Browns Ferry Unit 1 Restart Project Inspection Program. The purpose of IMC 2509 is to provide the policies and requirements for the restart inspection program, to establish a BF1 Restart Oversight Panel, and to document the major regulatory and licensee actions associated with the restart.
Documents associated with the NRC oversight of the BF1 Recovery can be found at on the NRCs website at http://www.nrc.gov/NRR/OVERSIGHT/ASSESS/bf1-recovery.html.
2 TVA In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room (PDR) or from the Publicly Available Records (PARS) component of NRCs document system (ADAMS).
ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). Should you have any questions concerning these meetings, please contact me at (404) 562-4501.
Sincerely,
/RA/
Joseph W. Shea, Deputy Director Division of Reactor Projects, Region II Docket No.: 50-259 License No.: DPR-33
Enclosures:
- 1. List of Attendees
- 2. NRC Browns Ferry Unit 1 Recovery Issues List (May 1, 2006)
- 3. TVA Presentation Handout - Browns Ferry Nuclear Plant - Unit 1 Restart cc w/encls: (See page 3)
OFFICE DRP:RII DRS:RII DRP:RII DRP:RII SIGNATURE LSM MSL1 MTW JWS1 NAME LMellen MLesser MWidmann JShea DATE 05/11/2006 05/15/2006 05/16/2006 05/26/2006 E-MAIL COPY?
YES NO YES NO YES NO YES NO YES NO YES NO YES NO
3 TVA cc w/encl.:
Ashok S. Bhatnagar Senior Vice President Nuclear Operations Tennessee Valley Authority Electronic Mail Distribution Larry S. Bryant, Vice President Nuclear Engineering & Technical Services Tennessee Valley Authority Electronic Mail Distribution Brian O'Grady Site Vice President Browns Ferry Nuclear Plant Tennessee Valley Authority Electronic Mail Distribution Preston D. Swafford Senior Vice President Nuclear Support Tennessee Valley Authority Electronic Mail Distribution General Counsel Tennessee Valley Authority Electronic Mail Distribution John C. Fornicola, Manager Nuclear Assurance and Licensing Tennessee Valley Authority Electronic Mail Distribution Bruce M. Aukland, Plant Manager Browns Ferry Nuclear Plant Tennessee Valley Authority Electronic Mail Distribution Glenn W. Morris, Manager Corporate Nuclear Licensing and Industry Affairs Tennessee Valley Authority Electronic Mail Distribution William D. Crouch, Manager Licensing and Industry Affairs Browns Ferry Nuclear Plant Tennessee Valley Authority Electronic Mail Distribution State Health Officer Alabama Dept. of Public Health RSA Tower - Administration Suite 1552 P. O. Box 303017 Montgomery, AL 36130-3017 Chairman Limestone County Commission 310 West Washington Street Athens, AL 35611 Masoud Bajestani, Vice President Browns Ferry Unit 1 Restart Browns Ferry Nuclear Plant Tennessee Valley Authority P. O. Box 2000 Decatur, AL 35609 Robert G. Jones, General Manager Browns Ferry Site Operations Browns Ferry Nuclear Plant Tennessee Valley Authority P. O. Box 2000 Decatur, AL 35609 Distribution w/encl: (See page 4)
4 TVA Meeting Summary to Karl W. Singer from Joseph W. Shea dated May 26, 2006.
SUBJECT:
MEETING SUMMARIES: 1.) CATEGORY 1 PUBLIC MEETING WITH TENNESSEE VALLEY AUTHORITY (TVA) RE. BROWNS FERRY UNIT 1 RECOVERY STATUS; 2.) MEETING OF THE NRC RESTART PANEL FOR THE BROWNS FERRY UNIT 1 RECOVERY - DOCKET NO. 50-259 Distribution w/encl:
M. Chernoff, NRR E. Hackett, NRR M. Widmann, DRP K. Clark, RII M. Lesser, DRS B. Bearden, DRP C. Casto, DRP J. Shea. DRP L. Plisco, RII B. Wetzel, OEDO M. Marshall, NRR L. Slack, RII EICS RIDSRIDSNRRDIPMLIPB PUBLIC List of Attendees NRC/TVA Unit 1 Restart Management Meeting Nuclear Regulatory Commission E. Hackett, Director, Project Directorate II (PDII), Division of Operating Reactor Licensing (DORL), NRR M. Marshall, Section Chief, PDII, DORL, NRR M. Chernoff, Browns Ferry Unit 1 Project Manager, PDII, DORL, NRR J. Shea, Deputy Director, Division of Reactor Projects (DRP), Region II (RII)
M. Widmann, Chief, DRP, Branch 6, RII M. Lesser, Chief, Engineering Branch 3, Director, Division of Reactor Safety (DRS), RII B. Bearden, Unit 1 Senior Resident Inspector, Browns Ferry, DRP, RII S. Shaeffer, Senior Project Engineer, Branch 6, DRP, RII L. Mellen, Senior Project Engineer, Branch 6, DRP, RII C. Stancil, Resident Inspector, Branch 6, DRP K. Clark, Public Affairs, RII Browns Ferry (TVA)
B. OGrady, Site Vice President M. Bajestani, Vice President Unit 1, Restart T. McGrath, Senior Project Manager, Operational Readiness W. Crouch, Site Licensing & Industry Affairs Manager R. Baron, Unit 1 Nuclear Assurance Manager E. Hollins, Unit 1 Maintenance & Mods Manager J. McCarthy, Unit 1 Licensing C. Beasley, TVA Communications and Government Relations J. Fornicola, Manager Nuclear Assurance and Licensing G. Little, Unit 1 Restart Manager S. Aitken, Operations Readiness J. Valente, Engineering Restart Manager Public K. Middleton, News Corner K. Faulk, Birmingham News B. Lawson, Huntsville Times NRC REGION II - BROWNS FERRY UNIT 1 RECOVERY ISSUES LIST Issue Status as of May 1, 2006 Reconciled with last TVA Quarterly Update (February 21, 2006)
Last BF1 Public Restart Meeting: December 7, 2005 at Browns Ferry Summary TVA Special Programs - There are 27 TVA Special Programs identified in the TVA Regulatory Framework Letter (dated 12/13/2002) regarding Unit 1 recovery. Prior to the Unit 1 recovery, additional Special Programs existed which were closed and/or combined with the remaining 27. This matrix identifies all 30 Special Program areas in order to clarify how several programs have been consolidated into the inspection process based on how the issues were reviewed for the Unit 2 and 3 recoveries. TVA is providing Special Program closures for the 27 they identified via a comprehensive quarterly issue update letter.
18 Open - (out of 30 listed in this matrix) 12 Inspections complete - (based on the reviews performed, no further NRC inspections are anticipated in this area)
Initial inspections have been performed for most Special Programs. Inspections are complete for: Cable Tray Supports, Conduit Supports, Configuration Management (including Design Calc. Review subpart), IGSCC, Drywell Platforms, Platform Thermal Growth and Seismic II/I as of 01/06.
Generic Communications Open Items - Includes all items from TVA Regulatory Framework correspondence and other NRC reviews to identify issues for Unit 1. These include NRC Generic Letters, Bulletins, Multi-plant Actions (MPA), Three Mile Island (TMI) Items, Temporary Instructions (TI), etc.
30 Open 36 Closed (Items adequately resolved for restart in accordance with NRC Inspection Manual Chapter (MC) 2509.
Open Items (LERs, URIs, and IFIs) - Includes items identified as open for Unit 1 based on historical docket review. This was the primary inspection area in 2004. Also includes any recently identified issues pending resolution.
3 Open Listed below.
53 Closed Adequately resolved for restart per MC 2509 and closed in an IR since BF1 Recovery inspections began in 2003.
Remaining Unit 1 LERs, URIs, and IFIs LER 88-37 Inadequate Design Results for HVAC (Seismic Issue) - Vias reviewed 9/05, field work not complete, to be rescheduled, 07/06.
URI 05-16-01 Use of Local Manual Operator Actions to Achieve Safe Shutdown during a fire (see Special Program #12).
URI 09-06-01 Adequacy of RHRSW SRTS Activities NOTES:
An extensive review of inspection reports (IR) back to 1985 was done for all open inspection items against Unit 1. Many of these were resolved but never formally closed on the Unit 1 docket. Most of these items have now been formally closed in a Unit 1 IR and recorded in NRCs RPS tracking program. Open allegations, OI investigations, and emerging/draft issues are not contained in this list. Open Licensing Actions with NRR are maintained on a separate list, but will be evaluated for addition to this list by the Restart Panel.
Sources for all the above issues include: Historical RPS, SIMS, NUREG 1435 (Status of Safety Issues at Licensed Power Plants),
SECY 95-264 (final Unit 3 Restart Matrix)
TVA SPECIAL PROGRAMS (Endorsed per 8/14/03 Reg Framework ltr from NRR/Marsh)
Description Resolved on U2-3 (Nureg 1232 Vol. 3 Section /
Prev. SER)
Nrc Insp Lead/
Alternate Insp Reports (C-Inspection Completed)
TVA Closure Status (Planned)
Tracked in TVA Restart Issues Letter NRR Unit 1 Covered by Prev U2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 1
Cable Ampacity 3.11.3 DRS-C.
Smith 04-07 Open 9/27/06 Yes NUREG-1232 No Additional inspection TBD pending completion of modifications for sample.
Inspection scheduled 7/06.
2 Cable Installation/
Cable Separations Issues 3.11.4,.5 DRS-Staples 04-07 04-09 05-08 05-09 Open 9/27/06
Related closure item LER 88-32. Ref. 1/28/93 closure letter.
U2 closed in IR 90-25. U3 closed in IR 95-25.
3 Cable Splices 3.13 DRS-Merriweather, Rodriguez 04-08 05-08 Open 9/27/06 Yes SER 4/08/92 1/23/91 No Inspection scheduled 6/06.
Thermal overload issues identified in IR 05 will need to address extent of condition reviews once completed by TVA.
4 Cable Tray Supports 2.2.2.7; SE 12/17/91 DRS-Vias, Nazario 03-10 04-06 05-08C Closed 2/18/05 Yes SER 12/17/91 11/19/92 3/19/93 No Inspection complete - no further action planned. TVA 10/7/04 letter on SQUG [GL 87-02] summarized resolution.
U3 closed in IRs 90-22,95-14, 95-20, 95-52.
TVA SPECIAL PROGRAMS (Endorsed per 8/14/03 Reg Framework ltr from NRR/Marsh)
Description Resolved on U2-3 (Nureg 1232 Vol. 3 Section /
Prev. SER)
Nrc Insp Lead/
Alternate Insp Reports (C-Inspection Completed)
TVA Closure Status (Planned)
Tracked in TVA Restart Issues Letter NRR Unit 1 Covered by Prev U2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 5
Component and Piece Part Qualification 3.3 DRS-Merriweather.
In combination with EQ (11)
Open 6/26/06 Yes 12/07/93 NRC letter said could be closed via inspection No Initial program review completed during EQ inspection - not specifically discussed in IR at this time.
Inspections planned 10/06 and 1/07.
U3 closed in IR 95-60.
6 Conduit Supports 2.2.2.3 DRS-Vias, Nazario 04-06 05-08C Closed 2/18/05 Yes SER 10/24/89 3/20/92 11/19/92 3/19/93 No Inspection complete - no further action planned. TVA 10/7/04 letter on SQUG [GL 87-02] summarized resolution U3 closed in IRs 95-15 & 95-
- 57.
7 Configuration Mgmt/ Design Baseline 2.1 DRS-Mellen, SSDPC Team 05-08C Closed 5/19/05 Yes NRC 11/21/91 approval letter on U1 docket No Inspection complete, no further action planned.
Utilized baseline SSDPC inspection procedure for review.
Related to Item #10.
8 Containment Coatings 3.7 DRS-Lenahan/Vias 04-07 04-08 05-06 06-06 Open 8/14/06 Yes NUREG 1232 covered U2.
No Torus closeout insp. 8/30/04 was deferred to and closed in 3/05. Drywell coating review scheduled for fall 2006.
U3 closed in IRs 94-01, 94-09, 94-18, 94-27.
TVA SPECIAL PROGRAMS (Endorsed per 8/14/03 Reg Framework ltr from NRR/Marsh)
Description Resolved on U2-3 (Nureg 1232 Vol. 3 Section /
Prev. SER)
Nrc Insp Lead/
Alternate Insp Reports (C-Inspection Completed)
TVA Closure Status (Planned)
Tracked in TVA Restart Issues Letter NRR Unit 1 Covered by Prev U2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 9
Control Rod Drive insert
/withdrawal piping 2.2.3.2 DRS-
- Lenahan, Vargas 04-07 04-08 05-08 05-09 06-06C Open 5/08/06 Yes NUREG 1232 covered U2.
No U3 closed in IR 95-52.
10 Design calc review 2.1 DRS-Mellen, Unit 1 SSDPC type team inspection 05-08C Closed 5/19/05 No, TVA tracking as #7, design baseline NRC 11/21/91 approval letter on U1 docket No Inspection complete, no further action planned.
Utilized baseline SSDPC inspection procedure for review. This item incorporated into Item #7.
11 Environmental Qualification 3.2 DRS-Merriweather, Mas-Penaranda 03-10 04-08 05-08 Open 7/31/06 Yes NUREG 1232 covered U2 No Inspections planned 10/06 and 1/07.
U3 closed in IRs 95-43, 95-56.
TVA SPECIAL PROGRAMS (Endorsed per 8/14/03 Reg Framework ltr from NRR/Marsh)
Description Resolved on U2-3 (Nureg 1232 Vol. 3 Section /
Prev. SER)
Nrc Insp Lead/
Alternate Insp Reports (C-Inspection Completed)
TVA Closure Status (Planned)
Tracked in TVA Restart Issues Letter NRR Unit 1 Covered by Prev U2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 12 Fire Protection/10 CFR 50, Appendix R 3.1 DRS-Fillion,
- Wiseman, Rodriguez 04-09 05-16 Open 8/7/06 Yes SER 12/08/88 11/03/89 3/31/93 11/02/95 A review of the U1 licensing basis is in progress to confirm TVAs approach to this area. Jan 3, 2006 NRC Ltr requestin g U1 FP program.
Previous SERs addressed overall approach, no Unit 1 specific exemptions considered required. First prelim. review in IR 04-09.
Initial inspection of App. R SSD analysis occurred in Nov 05 & identified inconsistencies in SERs and large reliance on manual actions (URI 05-16-01).
Next triennial inspection sched. 8/06 for U 1, 2, & 3.
Team to include determination if any impact from manual action or hot short generic resolutions.
U3 was closed in IRs 94-27, 95-04, 95-07, 95-37.
13 Flexible Conduits 3.12 DRS-Staples, 04-07 04-09 06-06C Open 7/31/06 Yes SER 3/19/93 SER 10/3/95 No Related to GL 87-02 resolution.
14 Fuses 3.11 DRS-Merriweather, Christnot assist in sampling verification 04-08 05-08 Open 9/20/06 Yes NUREG 1232 covered U2 SER.
4/14/89 No Program reviewed in 04-08.
Next inspection 6/06.
U3 closed in IRs 93-02, 93-08, 95-02, 95-45.
TVA SPECIAL PROGRAMS (Endorsed per 8/14/03 Reg Framework ltr from NRR/Marsh)
Description Resolved on U2-3 (Nureg 1232 Vol. 3 Section /
Prev. SER)
Nrc Insp Lead/
Alternate Insp Reports (C-Inspection Completed)
TVA Closure Status (Planned)
Tracked in TVA Restart Issues Letter NRR Unit 1 Covered by Prev U2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 15 HVAC Duct Supports 2.2.2.4 DRS-Vias, Nazario Open 5/25/06 Yes NUREG 1232 covered U2 SER.
10/24/89 8/22/90 No Next inspection 07/06. Also address LER/88-37 during next inspection.
U3 closed in IRs93-201 &
95-52.
16 Instrument Sensing Lines 3.4 DRS-Lenahan Open 7/13/06 Yes SER 12/10/91 No U3 closed IRs 94-24, 95-56.
17 Instrument Tubing 2.2.3.4 DRS-
- Lenahan, Nazario 05-08 Open Combine d with Small Bore Special Program No Program combined with small bore piping (Item 29) in original regulatory framework letter.
18 Intergranular Stress Corrosion Cracking (IGSCC) 3.6 DRS-Fuller 03-09 03-10 04-06 04-07 04-09 05-08C Open Yes SER 12/21/89 U2 SER 12/03/93 U3 SER 4/25/05 NRR to issue SE.
NRC letter to TVA RAI Inspection Complete.
Program submitted for review 7/21/04. Scope of U1 different than U2 and 3.
Reviews have included recirc and RBCCW piping, Mechanical Stress Improvement Process (MSIP).
U3 closed in IRs 92-31 &
93-05.
TVA SPECIAL PROGRAMS (Endorsed per 8/14/03 Reg Framework ltr from NRR/Marsh)
Description Resolved on U2-3 (Nureg 1232 Vol. 3 Section /
Prev. SER)
Nrc Insp Lead/
Alternate Insp Reports (C-Inspection Completed)
TVA Closure Status (Planned)
Tracked in TVA Restart Issues Letter NRR Unit 1 Covered by Prev U2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 19 Large Bore Piping Supports 2.2.3.1 DRS-Chou, Rivera 03-09 05-06 05-08 05-09 Open
- Yes, TVA tracks as Bul 79-02 and 79-14, not as a special program NUREG 1232 No 20 Long Term Torus Integrity Program 2.2.4.3; SE 8/20/80 DRS-Chou 03-09 03-10 04-11(Esc.
Enf) 04-07 04-09 Open 7/5/06 Yes SER 5/06/85 2/10/92 No Complete in conjunction with large bore pipe program.
Internal torus complete.
U3 closed in IRs 94-15,95-03, 95-52.
21 Drywell Steel Platforms and Upper drywell platforms 2.2.2.5 DRS-Lenahan 03-09 04-07 05-08C Open 4/20/06 Yes SER 12/7/93 No Inspection complete, no further action planned.
22 Misc Steel Frames 2.2.2.6 SE 10/24/89 DRS-
- Lenahan, Carrion 03-09 06-06C Open No Drywell steel is complete.
-TVA to NRC 12/13/02 letter combined Misc Steel Frames into Lower Drywell Platforms and Miscellaneous Steel.
TVA SPECIAL PROGRAMS (Endorsed per 8/14/03 Reg Framework ltr from NRR/Marsh)
Description Resolved on U2-3 (Nureg 1232 Vol. 3 Section /
Prev. SER)
Nrc Insp Lead/
Alternate Insp Reports (C-Inspection Completed)
TVA Closure Status (Planned)
Tracked in TVA Restart Issues Letter NRR Unit 1 Covered by Prev U2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 23 Moderate Energy Line Break (MELB) 3.8 NRR/DRP Mellen Expected Closure 9/06 Complete 6/4/05 Yes NUREG 1232 Yes NRR issue letter to close.
TVA to NRC 6/25/04 letter completed TVA actions.
NRR provide documentation to support closure.
Reviewed for U3 in IR 95-52.
NRR to confirm using same program as U2/3. No onsite inspection planned.
24 Platform Thermal Growth 2.4 DRS-Lenahan 03-09 04-04 05-08 06-06 C Open No Inspection complete, no further action planned. TVA to NRC 12/13/02 letter combined Platform Thermal Growth into Lower Drywell Platforms and Miscellaneous Steel
TVA SPECIAL PROGRAMS (Endorsed per 8/14/03 Reg Framework ltr from NRR/Marsh)
Description Resolved on U2-3 (Nureg 1232 Vol. 3 Section /
Prev. SER)
Nrc Insp Lead/
Alternate Insp Reports (C-Inspection Completed)
TVA Closure Status (Planned)
Tracked in TVA Restart Issues Letter NRR Unit 1 Covered by Prev U2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 25 Probabilistic Safety Assessment (PSA) 3.9 NRR -
Chernoff DRS -
Bernhard Expected closure 9/06 Complete 2/18/05 No No SER for any unit (PSA).
NRC staff evaluation 9/28/94 for U2 (88-20) 5/20/98, 5/04/99 for U3 (88-20)
Yes Closure Ltr to Licensee from NRR to address both GL 88-20 and Special Program.
NRR reviews required (research). HQ PRA audit review completed 01/06.
Research evaluating risk aspect for EPU uprate.
Audit issues identified in licensee CAP.
Historical: TVA to NRC 12/13/02 letter closed PSA with BFN Multi-Unit PSA (April 14, 1995). NRC request ltr 6/21/04.
NRR to review TVAs 8/17/04 Resp to GL 88-20.
NRR response letter to close.
U3 closed in IR 95-49.
26 Q List 3.15 DRP-Bearden Open Yes Inspection planned 7/06.
27 Restart test program (RTP) 4.6 NRR/DRP Open 9/12/06 Yes NUREG 1232 SER 8/30/94 Yes NRR Ltr to TVA 6/15/05 requesting details of RTP.
Currently under tech staff review. Specific licensee system turnover reviews to be done on key systems by experienced inspectors familiar with BWR mitigating systems.
U3 closed in IRs 95-07, 08, 26, 51, 60.
TVA SPECIAL PROGRAMS (Endorsed per 8/14/03 Reg Framework ltr from NRR/Marsh)
Description Resolved on U2-3 (Nureg 1232 Vol. 3 Section /
Prev. SER)
Nrc Insp Lead/
Alternate Insp Reports (C-Inspection Completed)
TVA Closure Status (Planned)
Tracked in TVA Restart Issues Letter NRR Unit 1 Covered by Prev U2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 28 Seismic Class II Over I/Spacial Systems Interactions and Water Spray 2.2.4.2 DRS-Vias, Nazario 05-08C Open Yes SER 11/19/92 No Inspection complete, no further actions planned.
Include DCN 51192, as referenced in IR 04-06, Section E1.3. Related to GL 87-02.
29 Small Bore Piping
/Supports 2.2.3.3 DRS-
- Lenahan, Nazario Alternate -
Vias 05-08 06-06 Open Yes SER 10/24/89 2/4/92 No Inspect in conjunction with Instrument Tubing.
(Item 17)
Further inspection planned 07/06 (IR 06-07)
U3 closed in IRs 95-03, 95-57.
30 Thermal Overload 3.11 DRS-Merriweather 04-08 05-08 Open 9/20/06 Yes NUREG 1232 No Next inspection 6/06. NCV identified in IR 05-08 regarding TOL design implementation problems -
will need to address extent of condition reviews once completed by TVA.
U3 closed in IR 95-25.
GENERIC COMMUNICATIONS: Bulletins {BU} and Generic Letters {GL}
Issue Description Resolved on U2-3 (Nureg 1232 Vol.
3 Section /
Prev. Ser)
NRC Insp Lead/
Alternate Insp Reports
[C-closed]
TVA Closure Status Tracke d in TVA Restart Issues Letter NRR Unit 1 Covered by Prev U2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 1
BU 79-02 Pipe Support Base Plate Designs Using Concrete Expansion Anchor Bolts SER 2/8/90 DRS-Chou Open Yes NUREG 1232 Associated with large bore piping Special Program reviews.
2 BU 79-12 Short Period Scrams At BWR Facilities DRS-McDonald Open Yes Inspection planned 6/06. U3 item closed in IR 95-51, TVA action due 6/06.
3 BU 79-14 Seismic Analysis for As-Built Safety Related Piping Systems DRS-Chou Open Yes SER 10/24/89 NUREG 1232 Associated with large bore piping Special Program reviews.
U3 closed IRs 94-15, 94-29, 95-03, 95-52.
4 BU 80-06 Engineered Safety Feature Reset Controls DRS-Mas-Penaranda Open Yes No SER Inspection scheduled 10/29 Inspection planned 8/06. U3 item closed in IR 95-22, 5
BU 84-02 Failure of GE Type HFA Relays in Use in Class 1E Safety Systems DRP 04-09C Closed 2/18/05 Yes No SER U3 item closed in IR 95-43
GENERIC COMMUNICATIONS: Bulletins {BU} and Generic Letters {GL}
Issue Description Resolved on U2-3 (Nureg 1232 Vol.
3 Section /
Prev. Ser)
NRC Insp Lead/
Alternate Insp Reports
[C-closed]
TVA Closure Status Tracke d in TVA Restart Issues Letter NRR Unit 1 Covered by Prev U2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 6
BU 86-02 Static O Ring Differential Pressure Switches DRP 05-06C Closed 5/19/05 Yes No SER 94-31 U3 item closed in IR 94-31, see also IFI 93-04-01.
7 BU 88-03 Inadequate Latch Engagement in HFA Type Relays Manufactured by GE SER 8/2/90 NRR/DRP 04-09C Closed 2/18/05 Yes No SER TVA submittal required upon completion NRR determined issue is closed for Unit 2-3.
8 BU 88-04 Potential Safety Related Pump Loss DRP Bearden 04-09C Closed 2/18/05 Yes No SER Yes TI 2515/105 (orig.
did not require BF to do insp.).
TVA response submitted 5/04, U1 item addressed in IR 95-31. TVA to NRC 5/7/04 letter completed TVA actions.
9 BU 88-07 Power Oscillation in Boiling Water Reactors DRS-McDonald Complet e
Yes SER 5/31/94 Inspection planned 7/06. Reference TI 2515/099.
-NRC to TVA 5/31/1994 letter, TVA considers complete with issuance of TS amendment # 300.
GENERIC COMMUNICATIONS: Bulletins {BU} and Generic Letters {GL}
Issue Description Resolved on U2-3 (Nureg 1232 Vol.
3 Section /
Prev. Ser)
NRC Insp Lead/
Alternate Insp Reports
[C-closed]
TVA Closure Status Tracke d in TVA Restart Issues Letter NRR Unit 1 Covered by Prev U2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 10 BU 88-10 Nonconforming Molded-Case Circuit Breakers DRP-S.
Walker IR 05-09C Closed 2/21/06 Yes No SER.
NRC to TVA letter 3/10/92 Reference NRC to TVA letter 3/10/92 closed Bulletin for U1-verify no changes, to parts or installed components.
11 BU 90-01 Loss of Fill Oil in Rosemount Transmitters DRS-Moore/
Peabody IR 05-09C Closed 2/21/06 Yes SER 4/04/95 NRR closeout letter / SE 2/7/05 TI 2515/122 -
reference only.
MC change notice 95-08 deleted TI for BF1. TVA ltr 6/7/04.
12 BU 93-02 Debris Plugging of Emergency Core Cooling Suction Strainers DRP-Patterson Inspection complete.
IR 06-06 discussed To be closed pending SER.
Complet e
5/19/05 Closure Pkg.
Ready Yes 6/28/93 ltr 7/19/94 ltr SER pending per NRR No original SER for U2/3. TVA response 5/6/04.
U3 closed in IR 95-60.
13 BU 93-03 Resolution of Issues Related to Reactor Vessel Water Level Instrumentation in BWRs SER 4/20/94 DRP-Freeman Open Yes SER 4/20/94 TVA closure ltr See GL 92-04. Use TI 2515/128 reference. Verify installation to close. U3 closed IRs 95-31 and 95-56,93-201.
GENERIC COMMUNICATIONS: Bulletins {BU} and Generic Letters {GL}
Issue Description Resolved on U2-3 (Nureg 1232 Vol.
3 Section /
Prev. Ser)
NRC Insp Lead/
Alternate Insp Reports
[C-closed]
TVA Closure Status Tracke d in TVA Restart Issues Letter NRR Unit 1 Covered by Prev U2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 14 BU 95-02 Unexpected Clogging of a RHR Pump Strainer While Operating in Suppression Pool Cooling Mode DRP-Patterson Inspection complete To close in pending IR 05-09 Complet e 5/19/05 Closure Pkg.
Ready Yes SER 3/14/96 BU 93-02 No SER Was to be addressed for Unit 3 around startup.
15 BU 96-03 Potential Plugging of Emergency Core Cooling Suction Strainers by Debris in Boiling Water Reactors DRP-Patterson Inspection complete.
To be closed pending SER Complet e 5/19/05 Closure Pkg.
Ready Yes No SER SER pending per NRR 11/15/99 NRC letter completed review for U 2,3.
TVA committed to actions for U2/3.
Credit for containment over-pressure issue not yet approved for U1. Reg Guide under review.
NRR to determine U1 impact.
16 GL 82-33 Instrumentation to Follow the Course of an Accident - R.G.
1.97 SER 2/8/90 DRS-Mellen, Peabody 05-07C Closed 8/19/05 Yes SER 2/8/90 5/10/91 5/3/94 11/19/04 update letter for neutron monitoring U3 closed IRs 90-32,93-201, 95-39..
Ref.TI 2515/87.
NRR reviewing an amendment involving a proposed upgrade to the neutron monitoring system.
GENERIC COMMUNICATIONS: Bulletins {BU} and Generic Letters {GL}
Issue Description Resolved on U2-3 (Nureg 1232 Vol.
3 Section /
Prev. Ser)
NRC Insp Lead/
Alternate Insp Reports
[C-closed]
TVA Closure Status Tracke d in TVA Restart Issues Letter NRR Unit 1 Covered by Prev U2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 17 GL 83-08 Modification of Vacuum Breakers on Mark 1 Containments DRP-Bearden 05-06C Closed 5/19/05 Yes TVA submittal required upon completion Ref. TI 2515/096, NRC letter 11/25/86 for all three units.
-Item 1.2 Trip Review
-Item 4.5.2 Periodic On-Line Testing
-Item 4.5.3 Intervals for On-Line Testing DRP-DiPaolo Open Yes Multiple SERs 8/17/90 9/2/86 10/27/86 3/23/88 6/1/89 5/1/89 9/2/86 6/12/85 6/17/85 TI 2515/064 & TI 2500/020 A-9 (this is a TI requiring inspection).
Item 1.2 Trip review remains open.
19 GL 87-02 Verification of Seismic Adequacy of Mechanical and Electrical Equipment In Operating Reactors DRS-Vias 06-06 04-06.
Open Yes SER 3/21/2000 Yes, NRR SE required Related to USI A-
- 46. Status in, E1.3. Program submittal 10/7/2004. No U2,3 ref. Related to Special Program Seismic II/I
GENERIC COMMUNICATIONS: Bulletins {BU} and Generic Letters {GL}
Issue Description Resolved on U2-3 (Nureg 1232 Vol.
3 Section /
Prev. Ser)
NRC Insp Lead/
Alternate Insp Reports
[C-closed]
TVA Closure Status Tracke d in TVA Restart Issues Letter NRR Unit 1 Covered by Prev U2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 20 GL 88-01 NRC Position on IGSCC in BWR Austenitic Stainless Steel Piping SER 12/3/93 DRS-Fuller 05-08.
06-06 Open Yes Yes, NRR SE required.
2/3/06 NRC letter to TVA RAI IR 95-44. See Special program IGSCC closed in 05-08.
21 GL 88-11 Radiation Embrittlement of Reactor Vessel Materials and its Impact on Plant Operations SER 6/29/89 NRR/Mellen, NRR to review TS 293 to determine U1 impact, any RAI.
Closed 5/19/05 Yes 6/29/89 No Ref. USI A-26.
NRR considers issue closed.
NRC to TVA 1/8/93 letter regarding PT curve change, TVA considers complete with issuance of TS 293. NRR to confirm to allow closure.
22 GL 88-14 Instrument Air Supply System Problems Affecting Safety Related Equipment SER 5/9/89 DRP-Mellen 05-08C Closed 11/21/05 Yes 5/9/89 ltr No IRs 95-38, 95-56.
GENERIC COMMUNICATIONS: Bulletins {BU} and Generic Letters {GL}
Issue Description Resolved on U2-3 (Nureg 1232 Vol.
3 Section /
Prev. Ser)
NRC Insp Lead/
Alternate Insp Reports
[C-closed]
TVA Closure Status Tracke d in TVA Restart Issues Letter NRR Unit 1 Covered by Prev U2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 23 GL 88-20 Individual Plant Examination of External Events for Severe Accident Vulnerabilities NRR-Chernoff DRS-Bernhard Planned closure 9/06 Closed 2/21/06 Yes No Yes, NRR to issue letter to licensee to close NRR reviews required, HQ audit conducted 01/06.
See Special Program - PSA.
Initial IPE was U2, then multi-plant was U2/3. TVA letter 1/14/05 indicating complete.
24 GL 89-06 Safety Parameter Display System SER 2/5/92 DRS-McDonald Open Yes Yes No Inspection planned 6/06. See TMI item 1D.2 25 GL 89-08 Erosion/Corrosi on - Induced Pipe Wall Thinning DRP-Bearden 05-09C Closed 2/21/06 Yes 8/21/89 ltr U3 closed IR 95-
- 41. Insp.
26 GL 89-10 Safety-Related Motor-Operated Valve Testing and Surveillance NRR/
DRP-Mellen 04-09 Open Yes No SER No TI 2515/109.
Propose NRR onsite review by Scarborough.
Acceptable to closeout via inspection
GENERIC COMMUNICATIONS: Bulletins {BU} and Generic Letters {GL}
Issue Description Resolved on U2-3 (Nureg 1232 Vol.
3 Section /
Prev. Ser)
NRC Insp Lead/
Alternate Insp Reports
[C-closed]
TVA Closure Status Tracke d in TVA Restart Issues Letter NRR Unit 1 Covered by Prev U2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 27 GL 89-13 Service Water System Problems Affecting Safety Related Equipment DRS-Maymi 05-09 06-07 (closure pending)
Closed 2/21/06 Yes SER 4/23/90 TVA submittal -
notification of action completion TI 2515/118, and TI 2515/159 as ref.
U3 closed in IR 95-
- 23. Adequate resources to complete in combination with heat sink during insp. 05/06.
28 GL 89-16 Installation of a Hardened Wetwell Vent SER 8/16/91 DRP-Shaeffer 05-06C Closed 2/21/06 Yes SER 8/16/91 No Reference TI 2515/121. U3 closed in IR 95-38, 95-56.
29 GL 92-01 Reactor Vessel Structural Integrity NRR DRP/Mellen Complet e-Package available Yes No SER NRR to issue closure ltr.
TVA to NRC 5/23/94 letter, TVA will inform NRC of the applicability of NEDO 32205 within 90 days of the final surveillance capsules analysis report. 7/07/99 letter closed for U 2,3.
GENERIC COMMUNICATIONS: Bulletins {BU} and Generic Letters {GL}
Issue Description Resolved on U2-3 (Nureg 1232 Vol.
3 Section /
Prev. Ser)
NRC Insp Lead/
Alternate Insp Reports
[C-closed]
TVA Closure Status Tracke d in TVA Restart Issues Letter NRR Unit 1 Covered by Prev U2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 30 GL 92-04 Resolution of the Issues Related to Reactor Vessel Water Level Instrumentation in BWRs SER 3/25/93 DRP-Freeman Complet e
Yes SER 3/25/93 No IR 93-16, see IEB 93-03,
-Long term actions were addressed as part of the resolution of Bulletin 93-03. TI 2515/119 ref. U2 93-16. NRC 3/25/93 letter found acceptable for all three units - verify.
31 GL 94-02 Long-Term Solutions and Upgrade of Interim Operating Recommendati ons for Thermal-Hydraulic Instabilities in BWRs DRS-McDonald Open Yes No SER Yes U3 closed in IR 94-11, 95-62. Ref TI 2515/119. Need SER to enable TVA to submit TS change on GE topical?
Inspections planned 6/06.
32 GL 94-03 Intergranular Stress Corrosion Cracking of Core Shrouds in BWRs DRS-Fuller 05-08C Closed 11/21/05 Yes SER 1/13/95 No U3 closed in IRs 94-16 & 95-44 See SP #18.
GENERIC COMMUNICATIONS: Bulletins {BU} and Generic Letters {GL}
Issue Description Resolved on U2-3 (Nureg 1232 Vol.
3 Section /
Prev. Ser)
NRC Insp Lead/
Alternate Insp Reports
[C-closed]
TVA Closure Status Tracke d in TVA Restart Issues Letter NRR Unit 1 Covered by Prev U2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 33 GL 95-07 Pressure Locking and Thermal Binding of Safety-Related and Power-Operated Gate Valves DRP-Beardon 06-06 C Open Yes SER 6/23/99 HQ
Response
No TVA action due 06/06 Lic. Response 5/11/04, 7/29/04.
NRC HQ Ltr/SE 1/28/05 closed.
34 GL 96-01 Testing of Safety-Related Logic Circuits DRS - S.
Walker Open Yes No SER No Inspection planned 6/06.
U2,3 - closed in 6/28/99 completion letter; IRs 98-03, 98-05, 98-07, & 98-09.
35 GL 96-05 Periodic Verification of Design Basis Capability of Motor Operated Valves DRP-Moore IR 05-09C Closed 2/21/06 Yes No SER No, closeout via inspection TVA considers complete since the industry program has been completed.
GENERIC COMMUNICATIONS: Bulletins {BU} and Generic Letters {GL}
Issue Description Resolved on U2-3 (Nureg 1232 Vol.
3 Section /
Prev. Ser)
NRC Insp Lead/
Alternate Insp Reports
[C-closed]
TVA Closure Status Tracke d in TVA Restart Issues Letter NRR Unit 1 Covered by Prev U2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 36 GL 96-06 Assurance of Equipment Operability and Containment Integrity During Design Basis Accident Conditions DRS-Vias05-08C Closed 11/21/05 Yes No SER HQ
Response
No NRC ltr 2/15/00 closed for all three units, however stated U1 would be revisited. TVA submitted response 5/12/04.
NRR letter 2/7/05 said TVA provided acceptable resolution.
37 GL 97-04 Assurance of Sufficient Net Positive Suction for Emergency Core Cooling and Containment Heat Removal Pumps DRP-Patterson Inspection complete IR 06-06 discussed.
To be closed pending SER Closed Yes BU 93-02 SER pending per NRR 6/11/98 Ltr closed for U 2,3. TVA response for U1 5/6/04-TVA considers complete based on Unit 1 EPU application, dtd 6/28/04.
38 GL 98-01 Readiness of Computer Systems at Nuclear Power Plants DRP-Shaeffer 05-06C Closed Yes No SER No NRC to TVA 10/18/99 letter completed.
GENERIC COMMUNICATIONS: Bulletins {BU} and Generic Letters {GL}
Issue Description Resolved on U2-3 (Nureg 1232 Vol.
3 Section /
Prev. Ser)
NRC Insp Lead/
Alternate Insp Reports
[C-closed]
TVA Closure Status Tracke d in TVA Restart Issues Letter NRR Unit 1 Covered by Prev U2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 39 GL 98-04 Potential for Degradation of the Emergency Core Cooling System and the Containment Spray System After a Loss of Coolant Accident Because of Construction and Protective Coating Deficiencies and Foreign Material in Containment DRS-Lenahan Close pending NRR program review.
Closed Yes NRR review TVA to NRC 5/11/04 letter provided response NRC 11/24/99 Ltr closed for all TVA sites.
THREE MILE ISLAND ACTION ITEMS Issue Description Resolved on U2-3 (Nureg 1232 Vol. 3 Section /
Prev. SER)
Nrc Insp Lead/
Alternate Insp Reports
[C-closed]
TVA Closure Status (Planned)
Tracked in TVA Restart Issues Letter NRR Unit 1 Covered by 2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 40 I.D.1 Control Room Design Review DRS-McDonald Open 3/28/06 Yes SER 10/29/91 Inspections planned 6/06.
41 I.D.2 Safety Parameter Display Console DRS-McDonald Open 7/24/06 Yes SER 2/05/92 Inspections planned 6/06.
42 II.B.3 Post-Accident Sampling System DRS-Hamilton 06-06 C Open 6/28/06 Yes SER 5/27/87 43 II.E.4.2.
1-4 Containment Isolation Dependability
- Implement Diverse Isolation, containment purge valves DRP-Bearden Open Yes SER 1/6/95 10/3/95 6/24/04 ltr HQ SE or Ltr required NRR review required.
44 II.F.1.2.
C Accident -
Monitoring -
Containment High Range Radiation DRS-Hamilton 06-06 C Open 5/9/06 Yes SER 1/8/82 45 II.F.1.2.
D Accident -
Monitoring -
Containment Pressure DRP-Bearden 05-06C Closed Yes SER 6/16/83
-NRC to TVA 11/8/90 letter closed issue.
THREE MILE ISLAND ACTION ITEMS Issue Description Resolved on U2-3 (Nureg 1232 Vol. 3 Section /
Prev. SER)
Nrc Insp Lead/
Alternate Insp Reports
[C-closed]
TVA Closure Status (Planned)
Tracked in TVA Restart Issues Letter NRR Unit 1 Covered by 2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 46 II.F.1.2.
E Accident -
Monitoring -
Containment Water Level DRP-Bearden 05-06C Closed Yes SER 6/16/83
-NRC to TVA 12/12/83 letter, TS Amendment 92 closed issue.
47 II.F.2.4 (Generic Letter 84-23)
Instrumentati on for Detection of Inadequate Core Cooling DRP-Patterson 05-07C Closed 8/19/05 Yes No SER 48 II.K.3.13 HPCI/RCIC Initiation Levels DRP-Bearden 05-07C Closed 8/19/05 Yes SER 9/19/83 TVA will notify upon completi on 49 II.K.3.18 ADS Actuation Modifications DRP-Bearden 05-07C Closed 8/19/05 Yes SER 5/29/90
THREE MILE ISLAND ACTION ITEMS Issue Description Resolved on U2-3 (Nureg 1232 Vol. 3 Section /
Prev. SER)
Nrc Insp Lead/
Alternate Insp Reports
[C-closed]
TVA Closure Status (Planned)
Tracked in TVA Restart Issues Letter NRR Unit 1 Covered by 2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 50 II.K.3.27 Common reference level for BWR DRP-Bearden 05-08C Open TVA tracking closure via TMI I.D.1.
No SER 9/19/83 Not on TVA letter, added during Shaeffer's review. See IRs 91-03, 91-10, U3 item closed in IR 95-16, NRR ltr dtd 12/30/82 agreed w/integration into I.D.1 and considered item closed for U1,2,3.
51 II.K.3.28 Qualification of ADS Accumulators DRP-Bearden 05-07C Closed 8/19/05 Yes SER 5/29/90 52 MPA-B011 Flood of equipment important to safety DRP-Monk No Reference TI 2515/088 Flooding information available in association with MELB reviews.
53 MPA-B041 Fire protection -
Final TS (including SER Sup)
DRS-Fillion 05-16 No Reference TI 2515/062, IRs 89-13, 90-06, 90-11.
URI 05-16-01 opened.
54 MPA-C002 BWR recirc pump trip (ATWS)
DRP-DiPaolo No TI 2515/095, ref. IRs 89-35, 95-60.
THREE MILE ISLAND ACTION ITEMS Issue Description Resolved on U2-3 (Nureg 1232 Vol. 3 Section /
Prev. SER)
Nrc Insp Lead/
Alternate Insp Reports
[C-closed]
TVA Closure Status (Planned)
Tracked in TVA Restart Issues Letter NRR Unit 1 Covered by 2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 55 TI 2500/20 Inspection to determine compliance with ATWS Rule 10 CFR 50.62 DRP-DiPaolo Open Yes SEE GL 83-28.
56 TI 2515
/111 EDSFI Followup Unit 1 Followup for previously performed electrical distribution inspection DRS-McDonald No To complete 2006, Review selected EDG/Bus loading calcs similar to U3 closure in 95-60.
Request calcs in advance. Inspection date TBD.
57 TI 2515
/154 Spent fuel Material Control and Accountability DRP/Beard en 04-08C No 58 TI 2515
/156 Offsite Power System Readiness DRP/Beard en 04-08C No USI A-44 Station Blackout.
59 TI 2515
/157 Mark I and II Containment Operations DRP/Beard en 04-08C No Not applicable to BF1 per Steve Stein, NRR.
Basis documented in 04-08.
THREE MILE ISLAND ACTION ITEMS Issue Description Resolved on U2-3 (Nureg 1232 Vol. 3 Section /
Prev. SER)
Nrc Insp Lead/
Alternate Insp Reports
[C-closed]
TVA Closure Status (Planned)
Tracked in TVA Restart Issues Letter NRR Unit 1 Covered by 2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 60 USI A-7 Mark 1 Long-Term
- Program, NuReg-0661, Supp 1 DRS-Chou Open No Reference TI 2515/85 Torus Integrity SP.
61 USI A-9 ATWS DRP-DiPaolo Open No TI 2500/020,SEE GL 83-28, USI A-75.
62 USI A-24 Qualification of Class 1E Safety-Related Equipment DRS-Merriweather Open No Ref. TI 2515/76.
Review with EQ Special Program 63 USI A-26 Reactor Vessel Pressure Transient Protection NRR/
Chernoff
/Mellen Closed 2/21/06 No SE to be issued for GL 88-11 TI 2500/019, Determine if DRP inspection required PT curves/see GL 88-11.
64 USI A-44 Station Blackout DRS-McDonald Open No TVA to implement DC power mods.
Previously closed for U3 IRs 95-16, 95-34, 95-60. Include Battery Performance
THREE MILE ISLAND ACTION ITEMS Issue Description Resolved on U2-3 (Nureg 1232 Vol. 3 Section /
Prev. SER)
Nrc Insp Lead/
Alternate Insp Reports
[C-closed]
TVA Closure Status (Planned)
Tracked in TVA Restart Issues Letter NRR Unit 1 Covered by 2-3 SER or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments 65 USI A-46 Verification of Seismic Adequacy of Mechanical and Electrical Equipment In Operating Reactors DRS-Vias 04-06 Open No SE-New Ref. GL 87-02.
66 USI A-75 MPA-B085, Required Actions on Generic Implications of Salem ATWS
Closed U3 in 95-60 Ref. GL 83-28.
OTHER MISC ISSUES (potential restart issues)
Issue Description NRC Insp Lead/
Alternate Closure IR NRR Unit 1 Covered by U2-3 Ser or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments A
New simulator qualification/
Fidelity and Operator staffing Review licensees new simulator to support 3 unit operations.
Review Licensed Operator staffing plans.
DRS-OLHPB -
J. Moorman N/A No. TVA will submit ltr when testing complete.
Letter submitted 7/28/05.
New simulator construction complete. Pre-op testing began June 05. RII OLB discussed with HQs OLB in May 05 - no requirement to inspect; however, will assess performance during Requal. insp. & review any outstanding fidelity issues.
Staffing - As of 11/05, BF has 43 ROs, 50 SROs.
Two exams scheduled prior to restart adding 15 RO and 8 SRO (3 are RO upgrades). Initial review indicates this would be more than adequate for 3 unit operation.
B Lay up inspections DRP-Bearden CLOSED -
Final layup inspection done in
- 2004, IR 04-06 No open concerns or further actions required.
C In-vessel inspections, core spray UT Full RPV internals and weld inspection complete June -
August, 2005 for 10 year ISI DRS - Lesser (Fuller, Crowley, Blake) 05-08 05-09 N/A N/A
OTHER MISC ISSUES (potential restart issues)
Issue Description NRC Insp Lead/
Alternate Closure IR NRR Unit 1 Covered by U2-3 Ser or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments D
ORAT Determine scope of unit start-up oversight reviews (likely reduced scope Operational Readiness Assessment Team
[ORAT]) and assemble
& schedule team.
Restart Panel to review inspection scope.
N/A N/A OPEN, coordinate time with licensee.
Could be performed prior to or during restart. Currently scheduled early 2007.
E Common Accident Signal DRP-Bearden 05-06 Expected closure fall for unit 1 No. License amendment submitted 3/05.
Amendment approved 4/1/04.
No TVA commitment.
During U2 restart, condition discovered which could have prevented automatic initiation of RHR and reported via LER 259/88-
- 12. LER was closed for U2 in IR89-35 and closed for U3 in IR95-58. Mods I/P U1-DCN51016, U2-DCN 51018 (complete), U3 -
DCN 51017. Unit 3 modification was not reviewed during U3 March 2006 outage. TVA Deferred this to Spring of 2008 because it was not required for Unit 1 recovery.
This was documented in the license ammendment 248 NRR Jan 2006 letter.
F Extended Power Uprate Determine scope of needed inspection reviews to support licensing action.
NRR Project Manager New SE OPEN - pending SER
OTHER MISC ISSUES (potential restart issues)
Issue Description NRC Insp Lead/
Alternate Closure IR NRR Unit 1 Covered by U2-3 Ser or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments G
Enhanced Restart Monitoring Restart Panel to determine duration.
Proposed 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> coverage.
DRP Coordinate.
Scope partially dependent on outcome of RTP (Special Program #27). Will focus on BWR Residents and OL examiners for observations. Include simulator walkdown for each participant.
H License Renewal Application Determine scope of needed inspection reviews to support licensing action.
& NRR Project Manager New SE issued 1/06.
Inspection TI to be completed by DRS.
Open. NRR will review the final Renewal OL, renewal inspections, and SER for Items that impact U1 restart. Determine if any additional inspection required as followup to LR inspections or other requirements. Unit 1 Followup Inspection (UFI)
Related to License Renewal Application (LRA) for the Browns Ferry Nuclear Plant (BFN), Units 1, 2, and 3
OTHER MISC ISSUES (potential restart issues)
Issue Description NRC Insp Lead/
Alternate Closure IR NRR Unit 1 Covered by U2-3 Ser or HQ Letter?
NRR New SE or TVA Submittal Req?
Comments I
Maintenance Rule U1 to comply with explicit scoping requirements of 50.65(b) for systems required to be operable or TS applicable.
NRR Project Manager/Region II inspection No No SE. Letter from TVA to confirm Unit 1 in compliance with 50.65(b).
Unit 1 currently has a temporary exemption from the Maintenance Rule which expires upon restart per NRC 8/9/99 letter. This area to be inspected for Reactor Oversight Process (ROP) transition and confirmation of Unit 1 Maintenance Rule scoping.
Next inspection schedule for 9/06 to include all three units.
J License Amendment 234 Review Improved Standard Technical Specifications NRR Project Manager Yes NRC to confirm License condition ITS. TVA to review TS changes made by License Amendment 234 and any other subsequent TS changes prior to entering Mode that TS applies.
K Turbine Building (TB)
Dynamic Seismic Analysis Confirm seismic demand accelerations for TB NRR Project Manager NRR to review.
License condition. NRC to confirm conclusions in TVA letter dated 9/17/04 for turbine building seismic loading.
E:\\Filenet\\ML061500069.wpd
LIST OF ACRONYMS USED C
Closed CA Corrective Action CFR Code of Federal Regulations EDG Emergency Diesel Generator EOC Extent of Condition Review EOP Emergency Operating Procedure FSAR Final Safety Analysis Report GL NRC Generic Letter IFI NRC Inspector Followup Item IFS Inspector Followup System ILRT Integrated Leak Rate Test (of the Reactor Building)
IR NRC Inspection Report LER Licensee Event Report MPA NRC Multi-Plant Action NRR Office of Nuclear Reactor Regulation OIL Open Item List OP Operating Procedure PM NRR Project Manager PER Problem EvaluationReport QA Quality Assurance RB Reactor Building RG Regulatory Guide RI Resident Inspector SER Safety Evaluation Report SFP Spent Fuel Pool SIMS Safety Issues Management System TIA NRC Task Interface Agreement (between NRC offices)
TS Technical Specifications UHS Ultimate Heat Sink URI NRC Unresolved Item VIO NRC Violation