Enclosure 2, Attachment 3, Dryer Instrumentation on New Steam Dryer for Quad Cities Unit 2, Summary of the Effects of the Sensor Cover Plates on Dynamic Pressure Measurements, GE-NE-0000-0038-2076-01-NP, Non-Proprietary, Revision 0, Dated AML051330052 |
Person / Time |
---|
Site: |
Quad Cities |
---|
Issue date: |
04/30/2005 |
---|
From: |
Choe H General Electric Co |
---|
To: |
Office of Nuclear Reactor Regulation |
---|
References |
---|
GE-NE-0000-0038-2076-01-NP, Rev 0 |
Download: ML051330052 (30) |
|
|
---|
Category:Report
MONTHYEARRS-24-080, Request to Replace Formerly Submitted Documents Available in the Agency Documents Access and Management System (ADAMS) with Documents Redacted in .2024-10-16016 October 2024 Request to Replace Formerly Submitted Documents Available in the Agency Documents Access and Management System (ADAMS) with Documents Redacted in . RS-24-046, 10 CFR 50.46 Annual Report2024-05-0606 May 2024 10 CFR 50.46 Annual Report RS-22-090, Response to Request for Additional Information Regarding Quad Cities New Fuel Storage Vault and Spent Fuel Storage Pool Criticality Methodologies2022-07-13013 July 2022 Response to Request for Additional Information Regarding Quad Cities New Fuel Storage Vault and Spent Fuel Storage Pool Criticality Methodologies NMP1L3469, Constellation Energy Company, LLC, Request for Use of Honeywell Mururoa V4F1 R Supplied Air Suits2022-06-30030 June 2022 Constellation Energy Company, LLC, Request for Use of Honeywell Mururoa V4F1 R Supplied Air Suits RS-22-006, Request to Expand Applicability of Prime Methods to Evaluate Fuel Centerline Melt and Cladding Strain Compliance for Framatome Fuel2022-01-20020 January 2022 Request to Expand Applicability of Prime Methods to Evaluate Fuel Centerline Melt and Cladding Strain Compliance for Framatome Fuel SVP-21-041, Regulatory Commitment Change Summary Report2021-07-15015 July 2021 Regulatory Commitment Change Summary Report RS-21-001, Revised Proposed Alternative to Utilize Code Cases N-878 and N-880 for Carbon Steel Piping2021-01-0404 January 2021 Revised Proposed Alternative to Utilize Code Cases N-878 and N-880 for Carbon Steel Piping ML20303A1752020-10-23023 October 2020 Proposed Relief Request from Section XI Repair/Replacement Documentation for Bolting Replacement of Pressure Retaining Bolting SVP-20-074, Technical Specifications Section 5.6.6 Post Accident Monitoring Instrumentation Report2020-10-0808 October 2020 Technical Specifications Section 5.6.6 Post Accident Monitoring Instrumentation Report RS-20-086, Renewed Facility Operating License Nos. DPR-29 and DPR-302020-09-24024 September 2020 Renewed Facility Operating License Nos. DPR-29 and DPR-30 ML19168A1962019-08-29029 August 2019 Staff Assessment of Flood Hazard Integrated Assessment RS-19-049, Submittal of 10 CFR 50.46 Annual Report2019-05-0202 May 2019 Submittal of 10 CFR 50.46 Annual Report ML19064B3712019-03-0505 March 2019 Enclosure B - QDC-0000-N-1481, Revision 3, Quad Cities Units 1 & 2 Post-LOCA Eab, LPZ, and CR Dose - AST Analysis. ML19064B3702019-03-0505 March 2019 Enclosure a - QDC-7500-M-2341, Revision 0, Quad Cities Units 1 & 2 Secondary Containment Drawdown Analysis. SVP-19-002, Submittal of 10 CFR 50.59, 10 CFR 72.48 Summary Report2019-01-0404 January 2019 Submittal of 10 CFR 50.59, 10 CFR 72.48 Summary Report RS-18-089, Report of Full Compliance with Phase 1 and Phase 2 of June 6, 2013 Commission Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions (EA-13-109)2018-08-14014 August 2018 Report of Full Compliance with Phase 1 and Phase 2 of June 6, 2013 Commission Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions (EA-13-109) RS-18-087, Report of Full Compliance with March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Number EA-12-049)2018-08-14014 August 2018 Report of Full Compliance with March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Number EA-12-049) RS-18-048, Submittal of 10 CFR 50.46 Annual Report Acceptance Criteria for Emergency Core Cooling Systems for Light-Water Nuclear Power Reactors.2018-05-0202 May 2018 Submittal of 10 CFR 50.46 Annual Report Acceptance Criteria for Emergency Core Cooling Systems for Light-Water Nuclear Power Reactors. SVP-17-046, Regulatory Commitment Change Summary Report2017-07-0606 July 2017 Regulatory Commitment Change Summary Report ML16271A3242016-10-31031 October 2016 Technical Review Documentation for Flooding Hazard Reevaluation of Quad Cities Nuclear Power Station, Units 1 and 2 RS-16-044, High Frequency Supplement to Seismic Hazard Screening Report, Response to NRC Request for Information, Per 10CFR50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima..2016-02-19019 February 2016 High Frequency Supplement to Seismic Hazard Screening Report, Response to NRC Request for Information, Per 10CFR50.54(f) Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima.. ML15309A4932016-02-10010 February 2016 Staff Assessment of Information Provided Pursuant to Title 10 of the Code of Federal Regulations Part 50, Section 50.54(f) Seismic Hazard Reevaluations for Recommendation 2.1 of the Near-Term Task Force ML15251A3842015-08-31031 August 2015 Attachment 9 - NP-3305NP, Revision 1, Mechanical Design Report for Quad Cities and Dresden Atrium 10XN Fuel Assemblies - Licensing Report. (Non-Proprietary) SVP-15-052, Submittal of Regulatory Commitment Change Summary Report2015-07-0808 July 2015 Submittal of Regulatory Commitment Change Summary Report RS-15-085, Provides Report of Full Compliance with March 12, 2012 Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentaiton (Order Number EA-12-051)2015-05-0707 May 2015 Provides Report of Full Compliance with March 12, 2012 Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentaiton (Order Number EA-12-051) RS-14-277, Proposed Alternative to Utilize Code Case N-513-4, Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Section XI, Division 12014-09-24024 September 2014 Proposed Alternative to Utilize Code Case N-513-4, Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Section XI, Division 1 SVP-14-057, Owner'S Activity Report Submittal Fifth 10 Year Interval 2014 Refueling Outage Activities2014-08-0101 August 2014 Owner'S Activity Report Submittal Fifth 10 Year Interval 2014 Refueling Outage Activities ML14176A9612014-06-24024 June 2014 Submittal of Non-Proprietary BWROG Technical Product, BWROGTP-11-006 - ECCS Containment Walkdown Procedure, Rev 1 (January 2011), as Formally Requested During the Public Meeting Held on April 30, 2014 ML14101A2282014-04-0707 April 2014 Holtec International Report No. HI-2125245, Revision 5, Licensing Report for Quad Cities Criticality Analysis for Inserts. RS-14-072, Seismic Hazard and Screening Report (Central and Eastern United States (CEUS) Sites), Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Re Recommendation 2.1 of the Near-Term Task Force Review of Insights..2014-03-31031 March 2014 Seismic Hazard and Screening Report (Central and Eastern United States (CEUS) Sites), Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) Re Recommendation 2.1 of the Near-Term Task Force Review of Insights.. RS-13-288, Request for License Amendment to Technical Specifications Section 5.6.5. Core Operating Limits Report.2013-12-19019 December 2013 Request for License Amendment to Technical Specifications Section 5.6.5. Core Operating Limits Report. ML13317A9572013-11-20020 November 2013 Mega-Tech Services, LLC Technical Evaluation Report Regarding the Overall Integrated Plan for Quad Cities Nuclear Power Station, TAC Nos.: MF1048 and MF1049 ML13199A0382013-07-16016 July 2013 Attachment 5 - Holtec International Report No. HI-2125245, Revision 2, Licensing Report for Quad Cities Criticality Analysis for Inserts - Non Proprietary Version IR 05000456/20132022013-01-31031 January 2013 Exelon Generation Co., LLC, U.S. Nuclear Regulatory Commission (NRC) Office of Investigations (01) Investigation; Summary of 01 Report No. 3-2010-034; NRC Inspection Report Conference Letter - Licensee IR 05000289/20132012013-01-31031 January 2013 Exelon Generation Co., LLC, U.S. Nuclear Regulatory Commission (NRC) Office of Investigations (01) Investigation; Summary of 01 Report No. 3-2010-034; NRC Inspection Report Conference Letter - Licensee ML13008A2192013-01-31031 January 2013 U.S. Nuclear Regulatory Commission (NRC) Office of Investigations (01) Investigation; Summary of 01 Report No. 3-2010-034; NRC Inspection Report Conference Letter - Licensee IR 05000454/20132022013-01-31031 January 2013 Exelon Generation Co., LLC, U.S. Nuclear Regulatory Commission (NRC) Office of Investigations (01) Investigation; Summary of 01 Report No. 3-2010-034; NRC Inspection Report Conference Letter - Licensee IR 05000461/20132012013-01-31031 January 2013 Exelon Generation Co., LLC, U.S. Nuclear Regulatory Commission (NRC) Office of Investigations (01) Investigation; Summary of 01 Report No. 3-2010-034; NRC Inspection Report Conference Letter - Licensee IR 05000237/20132022013-01-31031 January 2013 Exelon Generation Co., LLC, U.S. Nuclear Regulatory Commission (NRC) Office of Investigations (01) Investigation; Summary of 01 Report No. 3-2010-034; NRC Inspection Report Conference Letter - Licensee IR 05000373/20132012013-01-31031 January 2013 Exelon Generation Co., LLC, U.S. Nuclear Regulatory Commission (NRC) Office of Investigations (01) Investigation; Summary of 01 Report No. 3-2010-034; NRC Inspection Report Conference Letter - Licensee IR 05000352/20132012013-01-31031 January 2013 Exelon Generation Co., LLC, U.S. Nuclear Regulatory Commission (NRC) Office of Investigations (01) Investigation; Summary of 01 Report No. 3-2010-034; NRC Inspection Report Conference Letter - Licensee IR 05000219/20132012013-01-31031 January 2013 Exelon Generation Co., LLC, U.S. Nuclear Regulatory Commission (NRC) Office of Investigations (01) Investigation; Summary of 01 Report No. 3-2010-034; NRC Inspection Report Conference Letter - Licensee IR 05000277/20132012013-01-31031 January 2013 Exelon Generation Co., LLC, U.S. Nuclear Regulatory Commission (NRC) Office of Investigations (01) Investigation; Summary of 01 Report No. 3-2010-034; NRC Inspection Report Conference Letter - Licensee IR 05000254/20132012013-01-31031 January 2013 Exelon Generation Co., LLC, U.S. Nuclear Regulatory Commission (NRC) Office of Investigations (01) Investigation; Summary of 01 Report No. 3-2010-034; NRC Inspection Report Conference Letter - Licensee IR 05000272/20132012013-01-31031 January 2013 Exelon Generation Co., LLC, U.S. Nuclear Regulatory Commission (NRC) Office of Investigations (01) Investigation; Summary of 01 Report No. 3-2010-034; NRC Inspection Report Conference Letter - Licensee SVP-13-001, Summary Report of Completed Changes, Tests and Experiments for January 2011 - December 20122013-01-0404 January 2013 Summary Report of Completed Changes, Tests and Experiments for January 2011 - December 2012 ML12361A1002012-10-31031 October 2012 Report 12Q0108.40-R-001, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 1. Part 1 of 10 ML12361A0952012-10-31031 October 2012 Report 12Q0108.40-R-002, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 2. Part 12 of 15 ML12361A0942012-10-31031 October 2012 Report 12Q0108.40-R-002, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 2. Part 11 of 15 ML12361A0932012-10-31031 October 2012 Report 12Q0108.40-R-002, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 2. Part 10 of 15 2024-05-06
[Table view] Category:Technical
MONTHYEARRS-24-080, Request to Replace Formerly Submitted Documents Available in the Agency Documents Access and Management System (ADAMS) with Documents Redacted in .2024-10-16016 October 2024 Request to Replace Formerly Submitted Documents Available in the Agency Documents Access and Management System (ADAMS) with Documents Redacted in . RS-24-046, 10 CFR 50.46 Annual Report2024-05-0606 May 2024 10 CFR 50.46 Annual Report RS-22-090, Response to Request for Additional Information Regarding Quad Cities New Fuel Storage Vault and Spent Fuel Storage Pool Criticality Methodologies2022-07-13013 July 2022 Response to Request for Additional Information Regarding Quad Cities New Fuel Storage Vault and Spent Fuel Storage Pool Criticality Methodologies NMP1L3469, Constellation Energy Company, LLC, Request for Use of Honeywell Mururoa V4F1 R Supplied Air Suits2022-06-30030 June 2022 Constellation Energy Company, LLC, Request for Use of Honeywell Mururoa V4F1 R Supplied Air Suits RS-22-006, Request to Expand Applicability of Prime Methods to Evaluate Fuel Centerline Melt and Cladding Strain Compliance for Framatome Fuel2022-01-20020 January 2022 Request to Expand Applicability of Prime Methods to Evaluate Fuel Centerline Melt and Cladding Strain Compliance for Framatome Fuel RS-21-001, Revised Proposed Alternative to Utilize Code Cases N-878 and N-880 for Carbon Steel Piping2021-01-0404 January 2021 Revised Proposed Alternative to Utilize Code Cases N-878 and N-880 for Carbon Steel Piping SVP-20-074, Technical Specifications Section 5.6.6 Post Accident Monitoring Instrumentation Report2020-10-0808 October 2020 Technical Specifications Section 5.6.6 Post Accident Monitoring Instrumentation Report RS-20-086, Renewed Facility Operating License Nos. DPR-29 and DPR-302020-09-24024 September 2020 Renewed Facility Operating License Nos. DPR-29 and DPR-30 RS-19-049, Submittal of 10 CFR 50.46 Annual Report2019-05-0202 May 2019 Submittal of 10 CFR 50.46 Annual Report ML19064B3702019-03-0505 March 2019 Enclosure a - QDC-7500-M-2341, Revision 0, Quad Cities Units 1 & 2 Secondary Containment Drawdown Analysis. ML19064B3712019-03-0505 March 2019 Enclosure B - QDC-0000-N-1481, Revision 3, Quad Cities Units 1 & 2 Post-LOCA Eab, LPZ, and CR Dose - AST Analysis. RS-18-089, Report of Full Compliance with Phase 1 and Phase 2 of June 6, 2013 Commission Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions (EA-13-109)2018-08-14014 August 2018 Report of Full Compliance with Phase 1 and Phase 2 of June 6, 2013 Commission Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions (EA-13-109) RS-18-087, Report of Full Compliance with March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Number EA-12-049)2018-08-14014 August 2018 Report of Full Compliance with March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Number EA-12-049) ML16271A3242016-10-31031 October 2016 Technical Review Documentation for Flooding Hazard Reevaluation of Quad Cities Nuclear Power Station, Units 1 and 2 ML15251A3842015-08-31031 August 2015 Attachment 9 - NP-3305NP, Revision 1, Mechanical Design Report for Quad Cities and Dresden Atrium 10XN Fuel Assemblies - Licensing Report. (Non-Proprietary) RS-14-277, Proposed Alternative to Utilize Code Case N-513-4, Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Section XI, Division 12014-09-24024 September 2014 Proposed Alternative to Utilize Code Case N-513-4, Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Section XI, Division 1 ML14176A9612014-06-24024 June 2014 Submittal of Non-Proprietary BWROG Technical Product, BWROGTP-11-006 - ECCS Containment Walkdown Procedure, Rev 1 (January 2011), as Formally Requested During the Public Meeting Held on April 30, 2014 ML14101A2282014-04-0707 April 2014 Holtec International Report No. HI-2125245, Revision 5, Licensing Report for Quad Cities Criticality Analysis for Inserts. RS-13-288, Request for License Amendment to Technical Specifications Section 5.6.5. Core Operating Limits Report.2013-12-19019 December 2013 Request for License Amendment to Technical Specifications Section 5.6.5. Core Operating Limits Report. ML13317A9572013-11-20020 November 2013 Mega-Tech Services, LLC Technical Evaluation Report Regarding the Overall Integrated Plan for Quad Cities Nuclear Power Station, TAC Nos.: MF1048 and MF1049 ML13199A0382013-07-16016 July 2013 Attachment 5 - Holtec International Report No. HI-2125245, Revision 2, Licensing Report for Quad Cities Criticality Analysis for Inserts - Non Proprietary Version ML12361A0932012-10-31031 October 2012 Report 12Q0108.40-R-002, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 2. Part 10 of 15 ML12361A0862012-10-31031 October 2012 Report 12Q0108.40-R-002, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 2. Part 4 of 15 ML12361A0872012-10-31031 October 2012 Report 12Q0108.40-R-002, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 2. Part 5 of 15 ML12361A0892012-10-31031 October 2012 Report 12Q0108.40-R-002, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 2. Part 6 of 15 ML12361A0902012-10-31031 October 2012 Report 12Q0108.40-R-002, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 2. Part 7 of 15 ML12361A0912012-10-31031 October 2012 Report 12Q0108.40-R-002, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 2. Part 8 of 15 ML12361A0922012-10-31031 October 2012 Report 12Q0108.40-R-002, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 2. Part 9 of 15 ML12361A0952012-10-31031 October 2012 Report 12Q0108.40-R-002, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 2. Part 12 of 15 ML12361A1102012-10-31031 October 2012 Report 12Q0108.40-R-001, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 1. Part 10 of 10 ML12361A1112012-10-31031 October 2012 Report 12Q0108.40-R-002, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 2. Part 1 of 15 ML12361A1092012-10-31031 October 2012 Report 12Q0108.40-R-001, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 1. Part 9 of 10 ML12361A1082012-10-31031 October 2012 Report 12Q0108.40-R-001, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 1. Part 8 of 10 ML12361A1072012-10-31031 October 2012 Report 12Q0108.40-R-001, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 1. Part 7 of 10 ML12361A1122012-10-31031 October 2012 Report 12Q0108.40-R-002, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 2. Part 2 of 15 RS-12-169, Report 12Q0108.40-R-002, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 2. Part 3 of 152012-10-31031 October 2012 Report 12Q0108.40-R-002, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 2. Part 3 of 15 ML12361A1062012-10-31031 October 2012 Report 12Q0108.40-R-001, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 1. Part 6 of 10 ML12361A0942012-10-31031 October 2012 Report 12Q0108.40-R-002, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 2. Part 11 of 15 ML12361A1052012-10-31031 October 2012 Report 12Q0108.40-R-001, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 1. Part 5 of 10 ML12361A1042012-10-31031 October 2012 Report 12Q0108.40-R-001, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 1. Part 4 of 10 ML12361A1032012-10-31031 October 2012 Report 12Q0108.40-R-001, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 1. Part 3 of 10 ML12361A1012012-10-31031 October 2012 Report 12Q0108.40-R-001, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 1. Part 2 of 10 ML12361A1002012-10-31031 October 2012 Report 12Q0108.40-R-001, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 1. Part 1 of 10 ML12361A0992012-10-31031 October 2012 Report 12Q0108.40-R-002, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 2. Part 15 of 15 ML12361A0982012-10-31031 October 2012 Report 12Q0108.40-R-002, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 2. Part 14 of 15 ML12361A0962012-10-31031 October 2012 Report 12Q0108.40-R-002, Rev. 3, Seismic Walkdown Report in Response to the 50.54(f) Information Request Re Fukushima Near-Term Force Recommendation 2.3: Seismic for Quad Cities Generating Station Unit 2. Part 13 of 15 ML13199A0392009-07-30030 July 2009 Attachment 8 - Netco Report NET-259-03, Revision 5, Material Qualification of Alcan Composite for Spent Fuel Storage ML0821900132008-08-0707 August 2008 Monthly Operating Reports Second Quarter 2008 RS-07-157, Request for Technical Specification Change for Minimum Power Ratio Safety Limit2007-11-20020 November 2007 Request for Technical Specification Change for Minimum Power Ratio Safety Limit SVP-07-027, 90-Day Post Outage ISI Letter, Dated July 14, 20062007-05-0505 May 2007 90-Day Post Outage ISI Letter, Dated July 14, 2006 2024-05-06
[Table view] |
Text
ENCLOSURE 2 ATTACHMENT 3 "Dryer Instrumentation on New Steam Dryer for Quad Cities Unit 2, Summary of the Effects of the Sensor Cover Plates on Dynamic Pressure Measurements," GE-NE-0000-0038-2076-01-NP, Non-Proprietary, Revision 0, dated April 2005
GE Nuclear Energy GE-NE-0000-003 8-2076-01 -NP Revision 0 Class I April 2005 Dryer Instrumentation on New Steam Dryer for Quad Cities Unit 2
SUMMARY
OF THE EFFECTS OF THE SENSOR COVER PLATES ON DYNAMIC PRESSURE MEASUREMENTS H. Choe
GE Nuclear Energy 175 CurtnerAvenue San Jose, CA 95125 GE-NE-0000-0038-2076-01 -NP DRF 0000-0038-2076 Class I April 2005
SUMMARY
OF THE EFFECTS OF THE SENSOR COVER PLATES ON DYNAMIC PRESSURE MEASUREMENTS Prepared by: Hwang Choe, Principal Engineer Engineering and Technology Verified by: Jose L. Casillas, Fellow Engineering and Technology Approved by: Jennifer O'Connor, Project Manager Steam Dryer Instrumentation
GE-NE-0000-0038-2076-01 -NP PROPRIETARY INFORMATION NOTICE This is a non-proprietary version of the document GE-NE-0000-0038-2076-01-P which has the proprietary information removed. Portions of the document that have been removed are indicated by an open and closed bracket as shown here (( )).
IMPORTANT NOTICE REGARDING CONTENTS OF THIS REPORT Please Read Carefully The only undertakings of the General Electric Company (GE) respecting information in this document are contained in the contract between the company receiving this document and GE. Nothing contained in this document shall be construed as changing the applicable contract.
The use of this information by anyone other than a customer authorized by GE to have this document, or for any purpose other than that for which it is intended, is not authorized. With respect to any unauthorized use, GE makes no representation or warranty, and assumes no liability as to the completeness, accuracy or usefulness of the information contained in this document, or that its use may not infringe privately owned rights.
GE-NE-0000-0038-2076-01 -NP CONTENTS Page ABSTRACT v
- 1. INTRODUCTION 1
- 2. THE EFFECT OF COVER PLATES ON DRYER EXTERNAL FLOW PATTERN 3
- 3. COVER PLATE CORRECTION FACTOR FOR DYNAMIC PRESSURE MEASUREMENTS 9 3.1 Correction Factor by One-Dimensional Analysis 9 3.2 Correction Factor Confirmation by Wind Tunnel Testing 10
- 4. CONCLUSIONS AND RECOMMENDATIONS 17 APPENDIX A A-I iii
GE-NE-0000-0038-2076-01 -NP LIST OF FIGURES FigU re Page Figure I lPressure Sensor Cover Plate Design .2 Figure 2 A Comparison of the Dryer External Flow Patterns With and Without Cover Plates.......................................................................................................................5 Fiigure 3 Comparison of Pressure Distribution on the External I)ryer lHlood With and Without Cover Plates .6 Figure 4 Comparison of Detailed Pressure Distributions on the External Dryer Hood With and Without Cover Plates ......................... 7 Figure 5 Local Velocities Near Cover Plates ......................... 8 Figure 6 Predicted Pressure Amplitude Ratio of the Cover Plate over Flush Mounted Sensors in BWR Steam Environment with (( )) Approach Velocity ... 14 Figure 7 Predicted Pressure Amplitude Ratio of the Cover Plate over Flush Mounted Sensors in BIWR Steam Environment with (( )) Approach Velocity . ... 14 Figure 8 Predicted Pressure Amplitude Ratio of the Cover Plate over Flush Mounted Sensors in Room Temperature Air Environment with (( )) Approach Velocity................................................................................................................. 15 Figure 9 The Measured Pressure Wave Amplitude Ratios of the Cover Plate over the Flush Mounted Sensors .15 Figure 10 Turbulence Noise PSD Difference with No Acoustic Source [PSD with Cover Plate - PSD wvithout a Cover Plate] for Frequency Range of (( ]I. 16 Figure 11 Turbulence Noise PSD Difference with No Acoustic Source [PSD with Cover Plate - PSD without a Cover Plate] for Frequency Range (( )).... 16 iv
.U-GE-NE-0000-0038-2076-01 -NP ABSTRACT This report summarizes the effects of the pressure sensor cover plate on the dynamic pressure measurements to be taken on the replacement dryer. The effect of the cover plate on the dryer external flow is insignificant except that the increased hydraulic resistance due to the cover plates weakens the vortex in front of the main steam nozzle. It is recommended to further evaluate the effect of the weakened vortex after the in-plant dynamic pressure measurement data become available. The dynamic pressures measured with the cover plate do not require significant correction. This was predicted by a one-dimensional analysis, and supported by wind tunnel tests. The amplitude of the dynamic pressure measured on the cover plate may be ((
)) than measured by a flush mounted pressure sensor. The frequency of the pressure wave is not affected by the presence of the cover plate.
V
GE-NE-0000-0038-2076-01 -NP
- 1. INTRODUCTION The cause of the steam dryer cracking/failure is believed to be due to high level of pressure oscillation load on the steam dryer hoods at EPU power level. It is believed that the high level of dynamic pressure (meaning pressure oscillation or fluctuation compared to static pressure) is a result of potential resonance between the acoustic excitations and the flow induced pressure waves. Therefore, it is important to measure the dynamic pressures on the steam dryer hood to help define the dynamic loads on the dryer structure. Ideally, it is best to install the pressure sensors mounted flush on the surface. However, it is highly invasive and undesirable to make many holes on the dryer hood. Even after the pressure sensors are removed, inspection may be required during outage on the repaired holes where the pressure sensors used to be located. For this reason, a sensor cover plate was designed to install the pressure sensors with minimum perturbation to the flow and with minimum error for dynamic pressure measurements, and to allow easy removal after the in-plant measurements without affecting the structural integrity of the dryer. The pressure sensors that measure dynamic pressures are of piezoelectric type and do not sense the static pressure but only senses dynamic or time dependent pressure variations in the frequency range of 3 to 1000 Hz. The final cover plate design is shown in Figure 1.
The effects of the cover plate on dynamic pressure measurements may be summarized by the answers to the following two questions:
- 1. Would the presence of cover plates change the dryer external flow pattern? If the flow pattern change is significant, it could invalidate the measurement because it could change the phenomenon itself.
- 2. How much modulation or modification of the pressure wave signals would occur locally due to the cover plate? The effects of the cover plate on pressure wave amplitude and frequency should be evaluated as a function of pressure wave frequency, incoming flow velocity, and the amplitude of the incoming pressure wave. The results of this evaluation are summarized as a correction factor to the measured dynamic pressures.
In order to answer the first question, a three-dimensional steady state Computational Fluid Dynamics (CFD) study was performed with and without a cover plate. This study is summarized in Section 2. The dryer external flow pattern is not significantly affected by cover
GE-NE-0000-0038-2076-01 -NP plates, and a recommendation is made regarding a small change in the flow pattern observed.
Also this study provides the flow conditions for cover plates.
The second question was addressed by a one-dimensional analysis, and the results of the one-dimensional analysis were confirmed by wind tunnel testing. This study is summarized in Section 3. The correction needed for the cover plate is small.
Figure 1 Pressure Sensor Cover Platc Design 2
GE-NE-0000-0038-2076-01 -NP
- 2. The Effect of Cover Plates on Dryer External Flow Pattern A three-dimensional CFD model of the steam dryer external flow was developed to evaluate the effects of the cover plates on the dryer external flow pattern, and the detailed flow patterns were studied with and without a cover plate. In this section, only the relevant results are presented and discussed.
The following assumptions were used for this evaluation:
((
))
Figure 2 compares the dryer external flow patterns with and without cover plates. It is seen that there is no significant change in the dryer external flow pattern as a result of adding seven cover plates on the one half section of the dryer hood exterior surface. ((
)) This may be similar to the trip wires used on air plane wings that prevent stall, or flow separation behind the wing. This effect is manifested in pressure distribution also, which is discussed next.
Figure 3 compares the pressure distributions with and without cover plates. The maximum pressure depression is ((
3
GE-NE-0000-0038-2076-01 -NP
)). The area occupied by the maximum pressure depression is very small in size. The fact that the pressure depression is higher without a cover plate reveals that the vortex near the main steam nozzle is stronger without a cover plate. The flow that feeds the vortex slows down for the case with cover plates, and weakens the vortex. However, these pressure depressions are quite small in magnitude compared to the pressure depression with the current dryer. The current dryer has a pressure depression of ((
)). The current dryer has a square shaped hood, and has much smaller flowv area between the RPV wall and the dryer, and the secondary circulation pattern is greatly amplified. With the proposed new dryer, the dryer hood has a triangular shape instead of the current rectangular shape, and allows much wider flow area in this region. The wider flow area lowers the velocity, and the flow in front of the main steam nozzle behaves closer to the sink flow with the new dryer design.
Figure 4 shows further details of the pressure distributions over the dryer hood. Two numbers shown at the corner of the different regions represent the coordinates of the corners, and the average pressure difference across the dryer hood is shown inside each region using the unit of psi. ((
1))
Figure 5 shows the local velocity, at approximately one inch over the center of the cover plate. The approach velocity to the cover plates vary from (( I].
4
GE-NE-0000-0038-2076-01 -NP II Figure 2 A Comparison of the Dryer External Flow Patterns With and Without Cover Plates 5
. I.- I ---... - .
GE-NE-0000-0038-2076-01 -NP It Figure 3 Comparison of Pressure Distribution on the External Dryer Hood With and Without Cover Plates 6
GE-NE-0000-0038-2076-01 -NP
))
Figure 4 Comparison of Detailed Pressure Distributions on the External Dryer Hood With and Without Cover Plates 7
GE-NE-0000-0038-2076-01 -NP
[1 Figure 5 Local Velocities Near Cover Plates 8
GE-NE-0000-0038-2076-0 1-NP
- 3. Cover Plate Correction Factor for Dynamic Pressure Measurements In this section, the correction factor for the presence of the cover plate was evaluated analytically as well as experimentally by wind tunnel testing. The results of this evaluation are summarized in this section.
3.1 Correction Factor bv One-Dimensional Analysis The pressure wave modulation along the flow path over the sensor cover plate is complicated, and is of three-dimensional nature. However, if we select a stream tube that passes over the sensor area on the cover plate, it can be considered like a pipe because within the stream tube the mass flow is conserved and the overall direction is along the main flow direction.
Therefore, the stream tube can be considered as a pipe that has its flow area varied as the flow velocity varies, and one-dimensional analysis can be applied to the stream tube. The detailed derivation of the governing equation and the solution for one-dimensional analysis is provided in Appendix A. A steady state CFD analysis of the flow field around the cover plate was performed to obtain a more accurate velocity ratio, the maximum velocity over the sensor on the cover plate divided by the incoming velocity. The velocity ratio was calculated to be (( D.
Also from Figure 5 of Section 2, the approach velocity to the cover plate may vary from ((
)). These steady state CFD analysis results were incorporated for this evaluation.
Figure 6 shows the pressure wave amplitude ratio of the cover plate over the flush mounted sensors in the reactor steam environment with (( )) approach velocity, calculated according to the solution by the one-dimensional analysis. The pressure wave amplitude ratio varies between (( )). ((
)) Figure 7 shows the same result with the approach velocity changed from (( )). Comparing Figures 6 and 7, it is clear that the effect of Figure 8 shows the pressure wave amplitude of the cover plate over the flush sensors in the room temperature air environment, a typical condition for the wind tunnel testing, with ((
)) approach velocity, calculated according to the solution of the one-dimensional analysis. ((
))I 9
GE-NE-0000-0038-2076-01 -NP Separately Dr. F. J. Moody analyzed a three-dimensional potential flow problem for a sphere in an infinite flow medium with a constant velocity and a sinusoidal traveling pressure wave far away from the sphere. In his analysis, Dr. Moody assumed that a sphere can effectively model tile cover plate assuming the shape of the cover plate is a hemisphere and ignoring the viscous effects near the wall. His analysis indicates that the pressure amplitude ratio is ((
)). This independent calculation validates the applicability of the one-dimensional analysis performed in this section.
The potential frequency shift by Doppler effect was considered, and was calculated to be
)) of the frequency observed.
3.2 Correction Factor Confirmation bv Wind Tunnel Testing It was difficult to simulate the incoming two-dimensional pressure wave in the wind tunnel testing. The wind tunnel testing was performed in two sets of test series. The first series of testing was found out to be not applicable. Even for the second series of testing, only the last part of the testing is applicable. The following describes the sequence of trials for different methods of generating acoustic waves and why some of the methods were rejected.
((
10
GE-NE-0000-0038-2076-01 -NP
))
In this section, only the relevant results are summarized.
Figure 9 shows the pressure wave amplitude ratios for the cover plate over the flush mounted sensors as a function of frequency. The data in Figure 9 were generated by averaging 11
GE-NE-0000-0038-2076-01 -NP the 3 sets of 10 second test data for amplitudes as well as frequencies. Several observations were made:
((
C.
12
GE-NE-0000-0038-2076-01 -NP It is concluded that the wind tunnel test data supports the results of the one-dimensional analysis with the detailed review of PSDs as described above.
Figure II shows the PSD difference [PSD with the cover plate - PSD without a cover plate] (( )), without an acoustical source. ((
)) In summary, the cover plate does not generate its own pressure wave in the frequency range of 5 to 200 Hz.
The peak frequencies at the acoustic source and the peak frequencies measured on the sensor with and without cover plate were carefully compared. This examination reveals that there is no Doppler effect and there is no frequency shift. Occasionally there were some frequency shifts, but they appeared to be caused by the superposition of the turbulence noises on the acoustic wave instead of the Doppler shift.
13
GE-NE-0000-0038-2076-01 -NP
))
Figure 6 Predicted Pressure Amplitude Ratio of the Cover Plate over Flush Mounted Sensors in BWR Steam Environment wvith (( )) Approach Velocity 1II Figure 7 Predicted Pressure Amplitude Ratio of the Cover Plate over Flush Mounted Sensors in BWR Steam Environment with (( )) Approach Velocity 14
GE-NE-0000-0038-2076-01 -NP 11 Figure 8 Predicted Pressure Amplitude Ratio of the Cover Plate over Flush Mounted Sensors in Room Temperature Air Environment with (( ))
Approach Velocity
((
]1 Figure 9 The Measured Pressure Wave Amplitude Ratios of the Cover Plate over the Flush Mounted Sensors 15
GE-NE-0000-0038-2076-01 -NP Figure 10 Turbulence Noise PSD Difference with No Acoustic Source [PSD with Cover Plate - PSD without a Cover Plate] for Frequency Range of ((
((
Figure 11 Turbulence Noise PSD Difference with No Acoustic Source [PSD with Cover Plate - PSD vithout a Cover Plate] for Frequency Range ((
16
GE-NE-0000-0038-2076-01 -NP
- 4. CONCLUSIONS AND RECOMMENDATIONS The following conclusions are made from this evaluation:
- The dryer external flow field is not significantly affected as a result of the presence of the cover plates.
- The presence of the cover plates adds hydraulic resistance, and weakens the vortex in front of the main steam nozzle.
- The vortex in the current dryer is stronger, and the new dryer reduces the vortex strength.
The following recommendation is made:
- It is recommended to examine carefully the effects of weakened vortex on the dynamic pressure measurements due to cover plates. The presence of a vortex in front of the main steam nozzle would affect the sensors located closer to the main steam nozzle, and the vortex could produce an acoustic pressure wave at a certain frequency or frequencies. The examination of the dynamic pressure measurements would reveal the extent and magnitude of the effect of the cover plate on the dynamic pressure measurements by means of the weakened vortex.
17
GE-NE-0000-0038-2076-01 -NP Appendix A Derivation of One-Dimensional Solution for the Pressure Wave Modulation Considering the Effects of Friction and Flow Area Changes
((
A-I
GE-NE-oooo-oo38-2o76-ol -NP A-2
GE-NE-0000-0038-2076-01 -NP A-3
GE-NE-0000-0038-2076-01 -NP A4
GE-NE-0000-0038-2076-01 -NP A-5
GE-NE-0000-0038-2076-01 -NP REFERENCES A. I Moody, F. J., Introduction to Unsteady Thermofluid Mechanics, John Wiley &
Sons, 1990, Chapter 7.
A-6