ML050760434

From kanterella
Jump to navigation Jump to search
Final - RO & SRO Written Examination with Answer Key (Folder 3)
ML050760434
Person / Time
Site: Seabrook 
(NPF-086)
Issue date: 12/30/2004
From: Roy D
Florida Power & Light Energy Seabrook
To: Conte R
NRC/RGN-I/DRS/OSB
Conte R
References
50-443/05-301 50-443/05-301
Download: ML050760434 (135)


Text

FPL Energy Seabrook Station SEABROOK STATION 2005 NRC EXAMINATION ANSWER KEY

ParSCORE'"

I ParSCORE'" SCORE SHEET STUDENT ENROLLMENT SHEET o

o o o o o o o n n 0

0 0

1 1

1 1

1 1

1 1

1 1

1 1

')

2 2

2 2

2 2

2 2

2 2

2 2

(

3 3

3 3

3 3

3 3

3 3

3 3

1 4

4 4

4 4

4 4

4 4

4 4

4 1

I 5

5 5

5 5

5 5

5 5

5 5

5 5

1 7 7 7 7 7 7 1 1

1 7

7 7

7 I f,

G 6

6 6

6 6

6 6

6 6

6 6

8 8

8 8

8 8

8 8

8 8

8 8

8 9

9 9

, 9 9 9

9 9

9 9

9 9 9 1 B

O B

B B

B B

B B

B B

E B

B B

B B

B E

B B

B B

B c

c c

c U

D D

D E

E E

E F

F F

F G

G G

G H

H H

H c

c c

c c

c c

c c

c c

c c

c c

c c

c c

c U

O D

D D

D D

D D

D D

D D

D D

D D

D D

D E

E E

E E

E E

E E

F E

E E

E E

E E

E E

E F

F F

F F

F F

F F

F F

F F

F F

F F

F F

F C

G G

G G

G G

G G

G G

G G

G G

G G

G G

C H

H H

H H

H H

H H

H H

H H

H H

H H

H H

H 1

1 1

1 1

l I

I I

I I

I I

l l

l I

I I

I J

J J

J J

J J

J J

J J

J J

J J

J J

J J

J K

K K

K K

K K

K K

K K

K K

K K

K K

K K

K L

L L

L C

L L

L L

L L

L L

L L

L L

L L

L

~

Mh44MMMMMMMMMMMMMMMMM N

N N

N N

N N

N N

N N

N N

N N

N k

N N

N

-~~

o o o o o o o o o o o o o o o o u n o o P

P P

P P

P P

P P

P P

P P

P P

P P

P P

P Q

Q Q

Q Q

Q Q

Q Q

Q Q

Q O

Q O

Q Q

Q O

Q R

R R

R R

R R

R R

R R

R R

A R

R R

R A

R I

T T

T T

T T

T T

T T

T T

T T

T T

T T

T T

~

s s s s $ s s s s s s s s s s s s s s s u

u u

u u

u u

u u

u u

u u

u u

u u

u u

u v

v v

v v

v v

v v

v v

v v

v v

v v

v v

v w w w w w w w w w w w w w w w w w w w w x

x x

x x

x x

x x

x x

x x

x x

x x

x x

x Y

Y Y

Y Y

Y Y

Y Y

Y Y

Y Y

Y Y

Y Y

Y Y

Y z

z z

z z

z z

z z

z z

z z

z 7

z z

z z

z I

I I

I J

J J

J K

K K

K L

L L

L M

M Y

M N

N N

N 0

0 0

0 P

P P

P Q

Q Q

Q R

R R

A s

s s

s T

T T

T u

u u

u v

v v

v w w w w x

x x

x Y

Y Y

Y z z z z

-1 5 1 A B C 5 3 A B D

5'3 8 B C D

5 4 A B D

5 5 A B D

5 6 A B C

5 7 A B D

5 8 A C D 5 9 1 p d D 601 B C D 6

1

~

B 8 D 6 2 1 B C D 6

3

~

B C 6 4 A B I D

6 5

~

8 c D 6 6 A I C

D 6 7 A B fl D 6 8 A B C I 7 0 1 6 C D

6 9

~

B c 1 1

1 1

USE NO 2 PENCIL ONLY 9

9 9 l 8 1 A B C D

8 1 A B C D 8 3 A B C D 8

4

~

B C D

% A B C

0 R 6 A B C D

8 7 A B C; 0 a 8 A B c D 9 0 A B c q 8 9 A E C D

9 1 4 B C D

9 2 A B C D

9 3 A B C 0 9 4 A B C D

9 5 A B C D 9 6 A B C 0 97" B

C D

9 8 "

B C D

9 g A B C D

100A B C

TJ

~ I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Par SCO R E'"

STUDENT ENROLLMENT SHEET 1

1 1

2 2

2 3

3 3

4 4

4 5

5 5

6 6

6 7

7 7

8 8

8

\\ 9 9 9 I

<USE NO L-P'tNCk ONLY!&

-USE A NO 2 PENCIL ONLY

  • FILL IN BUBBLE COMPLETELY

- ERASE COMPLtTLVTO CHANGE

-DO NOT FOLD OR STAPLE ParSCORETM SCORE SHEET I

I I

0 0

0 0

0 0

0 0

0 1

1 1

1 1

1 1

1 1

2 2

2 2

2 2

2 2

2 3

3 3

3 3

3 1

3 3

1 4

4 4

4 4

4 4

4 4

5 5

5 5

5 5

5 5 5 5

6 6

6 6

6 6

6 6

6 6

7 7

7 7

7 7

7 7

7 7

8 8

8 8

8 8

8 8

8 8

1 1 5 A B C D

1 6 A 0 C D

1 7 A B C D

1 8 A B C

D 1 9 A B C D

2 0 A B C

D A

A A

A A

A A

A A

A A

A A

A A

A A

A A

A B

B B

B B

B B

B B

B B

B B

B B

B B

B B

B c

c c

c c

c c

c c

c c

c c

c c

c c

c c

c D

D D

D D

D D

D D

D D

D D

D D

D D

D D

D E

E E

E E

E E

E E

E E

E E

E E

E E

E E

E F

F F

F F

F F

F F

F F

F F

F F

F F

F F

F G

G G

G G

G G

G G

G G

G G

G G

G G

G G

G t i t i n H H H H n H n n H H n H t i n t i H n I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I J

J J

J J

J J

J J

J J

J J

J J

J J

J J

J I

K K

K K

K K

K K

K K

K K

K K

K K

K K

K K

L L

L L

L L

L L

C L

L L

L L

L L

L L

L M

M M

M M

M M

M M

M M

M M

M M

b J

M M

M i

N N

N N

N N

N b

N N

N N

N C

N N

N N

N O

O O

O O

O O

Q O

Q O

O O

O D

~

O O

O P

P P

P P

P P

P P

P P

P P

P P

P P

P P

Q Q

Q Q

Q Q

Q Q

Q Q

O Q

Q O

O Q

Q O

Q Q

R R

A R

R R

R R

R A

R R

R R

R R

R R

R R

s s s s s s s s s s s s s s s s s s s s T

T T

T T

T T

T T

T T

T T

T T

T T

T T

T u I1 u u u u u u u u u u u u u u u u u u v

v v

v v

v v

v v

v v

v v

v v

v v

v v

v w w w w w w w w w w w w w w w w w w w w x

x x

x x

x x

x x

x x

x x

x x

x x

x x

x Y

Y Y

Y Y

Y Y

Y Y

Y Y

Y Y

Y Y

Y Y

Y Y

Y z

L z

z z

z z

z L

z z

z z

z z

L z

z z

z L

A A

A A

~

B B

B c

c c

c D

D D

D E

E E

E F

F F

F G

G G

G H

H H

H I

I I

I J

J J

J K K K

K /

L L

L L

M M

M M

N N

N N

0 0

0 0

P P

P P

Q Q

Q Q

R R

R R

s s

s s

T T

T T

u u

u u

v v

v v

, w w w w T

F 4 1 A B C 0 4 ? A B C

D 4:jA B

C D

4411 a c u 4 5 A B C

U 4 6 A B C D

4 7 A B C D

4 8 A B C D

ji) A B C D'

5 0 A B C D

5 1 A B C D

5 2 A I3 C

D 5 3 A B C D 5 4 A 0 C D

55 A B C D

5 6 A B C D

5 7 A 0 C D 5 8 A E C 0 5 9 A B C 6 0 A B C 0 6 1 A B C tl 6 2 A B C

D 6 3 A B C D

6 4 A B C D

6 5 A B C D G 6 A B C D

6;A B C I2 u b A B C 9 6 9 A B C d 7 0 A B C a T

F 7 1 A B C D 7 2 A B C D

7 3 A 0 C D

7 3 A B C 0 7 5 A B C

D 7 6 A 0 I D 7 7 1 B C D

7 8 A 4 C D

8(3A B C I 79n 0 c I 8 1 A B C 8 2 A B C 8 3 A C

D 8 4 f B C D

8 6 A C

D 8 7 h 0 D

8 8 A I F

D 8 9 g 1 6 b 8

5

~

B c g o & 6 c 4 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 l l 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

ES-401 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 1

\\

Question # 1 Group I#

1 1

KIA #

EPE.007.GEN.2.4.2 1 Importance Rating 3.7 4.3 Proposed Question:

The control room crew have just completed immediate actions of E-0, Reactor Trip or Safety Injection and completed transition to ES-0.1, Reactor Trip Response. Shortly after entering this procedure, Safety Injection actuates and the Balance of Plant Operator notes Critical Safety Function Status as follows:

Subcriticality - GREEN Core Cooling - YELLOW Heat Sink - GREEN Integrity - YELLOW The Shift Manager checks containment conditions to determine if the containment barrier is intact. The following conditions exist:

0 Containment pressure: 42 psig and slowly rising Containment sump level: 3.2 feet and slowly rising Containment Radiation: 8.0 R/hr and stable All Containment Phase A & B penetrations are isolated Given these conditions, what is the correct crew response?

A. Transition to FR-Z.2, Response to Containment Flooding B. Transition to FR-Z. 1, Response to High Containment Pressure C. Remain in ES-0.1, Yellow Path Functional Restoration Procedures are entered on discretion only.

D. Remain in ES-0.1, until first transition at which time Functional Restoration Procedures become applicable.

Proposed Answer:

B Explanation of answer: B is correct because containment conditions generate an ORANGE path containment CSF status tree. Per rules of usage an orange path requires transition to appropriate FRP. In this case FR-Z. 1 is the correct procedure.

Explanation of Distractors:

A-incorrect because containment building level is <5ft, which is the trigger point of becoming orange.

C-incorrect because an orange path exists and rules of usage require transition, the second part of distractor is plausible because it is a true statement.

D-incorrect because an orange path exists and rules of usage require transition and FWs applied when the first transition from E-0 occurred versus ES-0.1.

Technical Reference(s):

FR-Z Status Tree, OPMM E-0, step 10

\\

Proposed references to be provided to applicants during examination:

None

ES-40 1 Seabrook Written Examination Question Worksheet F

o

~

ES-401-5 WA Knowledge of the parameters and logic used to assess the status of safety functions including, reactivity

~

~

~

i

~

control, core cooling and heat removal, RCS integrity, containment conditions, and radioactivity release control.

Question Source:

Modified Bank #22583 Original question attached to reference.

Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

55.4 1.1015 5.43.S L12 12106RO State the symptoms or entry conditions for FR-Z. 1.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 1

Question # 2 Group #

1 1

WA #

APE.008.AK3.03 Importance Rating 4.1 4.6 Proposed Question:

The following plant conditions exist:

- PCV-456A PORV and associated block valve is stuck open.

- The reactor trips and SI is initiated.

- The crew transitions from E-0, Reactor Trip or Safety Injection to E-1, Loss of Reactor or Secondary

- All systems are hctioning as expected with the exception of the stuck open PORV & block valve.

- Pressure is currently at 1350 psig and continues to decrease.

Coolant.

Which of the following statements provides accurate guidance for operation of RHR pumps as required by E-1 and what is the basis?

A. Do not secure RHR pumps because they may be needed at lower primary pressure.

B. Do not secure RHR pumps because primary pressure and level instrumentation are not reliable during steam space accident.

C. Secure RHR pumps because primary pressure is greater than 260 psig to reduce load on EDGs during design basis accident.

D. Secure RHR pumps and place in standby because pressure will not drop below 1250 psig for 1 stuck open PORV.

Proposed Answer:

A Explanation of answer: Step 8 does not allow securing RHR pump if pressure is decreasing Explanation of distractors:

B. Incorrect because the level instrument is not reliable, however the pressure instrument is OK.

C. Incorrect because this is not the basis for securing RHR D. Incorrect because cannot secure pump while pressure dropping Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

E-], L1413I Loss of Coolant TAA, Westinghouse ERG for E-1 None PZR Vapor Space Accidentknowledge of the reasons for the following responses as they apply to the PZR vapor space accident: actions contained in EOP for PZR vapor space accidentLOCA.

2003 NRC Exam (#83)/ Bank 55.4 1.10 L1413103RO For any LOCA, analyze the cooling mechanism for the core throughout the transient.

L1203105RO State the basis for the following steps, cautions, or notes found in E-1.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 1

Question # 3 Group #

1 1

WA #

EPE.009.EA2.04 Importance Rating 3.8 4.0 Proposed Question:

The following sequence of events and plant conditions exist:

0 A reactor trip and safety actuation has occurred.

The A Safety Injection pump FAILED to start both automatically and manually.

Pressurizer level is 17% and INCREASING SLOWLY.

Pressurizer pressure is 1900 psig and INCREASING SLOWLY.

Tave is 552 F and STABLE.

All other conditions and equipment are functioning normally.

If the B Safety Injection pump TRIPS on electrical overload, how will this affect pressurizer level and Reactor Coolant System (RCS) subcooling?

PRESSURIZER LEVEL RCS SUBCOOLING A. DECREASING DECREASING B. DECREASING STABLE C. STABLE DECREASNG D. INCREASING INCREASING Proposed Answer:

D Explanation of answer: 1900 is above the shutoff head of the SI pumps and pressurizer level and RCS pressure are increasing due to high head injection. Tavg is stable, indicating that the pressure and level increase are not due to temperature.

Explanation of distractors:

A-Incorrect because it represents conditions where the SI pumps would be necessary to maintain RCS inventory (RCS pressure below SI shutoff head)

B-Incorrect because pressurizer level will not decrease with high head pumps running and SI pumps at shutoff head.

C-Incorrect because subcooling will not decrease with increasing RCS pressure and stable RCS temperature.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

KIA Topic:

Question Source:

Bank Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

ECCS Detailed System Text (3.3), LP 14 131 (LOCA Transient Accident Analysis)

None Ability to determine or interpret PZR Level as applied to a SBLOCA.

55.4137 L1413102RO For any LOCA list or determine the two mechanisms of thermal hydraulic relationships, which determine the RCS pressure response to the accident.

L8034107RO List the RCS pressure at which high, intermediate and low head injection will occur.

Seabrook Written Examination Question Worksheet Form ES-40 1-5 ES-40 1 Examination Outline Cross-reference:

Level RO SRO Tier #

1 1

Question # 4 Group #

1 1

WA #

EPE.011.EK2.02 Importance Rating 2.6 2.7 Proposed Question:

Given the following plant conditions:

0 0

0 0

0 0

0 A Loss of Coolant Accident (LOCA) has occurred.

E-0, Reactor Trip or Safety Injection is being implemented.

Power is lost to 4.16kV Bus E-5.

Containment Pressure is 23 psig and increasing.

RCS Temperature is 532 F and decreasing.

RCS Pressure is 1320 psig and decreasing.

All systems responded normally to actuation signals.

Which of the following correctly describes the relationship between these plant conditions and reactor coolant pump (RCP) status?

The RCPs should A. be stopped because RCP cooling is lost.

B. be stopped because inadequate RCS subcooling margin exists.

C. NOT be stopped because adverse containment conditions exist.

D. NOT be stopped because with no power to Bus 5 there are no Safety Injection pumps operating.

Proposed Answer:

A Explanation of answer: Containment Pressure has exceeded 18 psig (Hi-3 setpoint) which causes Phase B isolation and subsequently isolates PCCW which cools the RCP motors and seals. Therefore procedural requirements have the operator secure RCPs when these conditions exist.

Explanation of distractors:

B-Incorrect because at 532 F saturation pressure is approximately 900 psig which is well above the required 40 F subcooling to trip RCPs. This is also based on a SBLOCA versus large break LOCA.

C-Incorrect because containment pressure is above 4.3 psig so therefore adverse conditions do exist, however there is no trip criteria at 4.3 psig.

D-Incorrect because Bus 6 is still available and therefore one SI pump is available. This is a plausible answer for a SBLOCA because without high head injection RCPs would not be tripped.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic Question Source:

Modified Bank #20884 Original question attached to reference.

Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

E-0 step 6 and OAS page criteria. Westinghouse ERG for RCP trip criteria. E-0 ERG Step 14 background document.

Knowledge of the interrelationships between the RCPs and Large Break LOCA.

Steam Tables 55.41.3/10 L1202103RO State the basis for the following steps, notes or cautions contained in E-0. L1202105RO State the RCP trip criteria found in E-0.

ES-401 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

Question # 5 Group #

1 1

WA #

0 10.A3.02 Importance Rating 3.6 3.5 Proposed Question:

Given the following conditions:

The plant is operating at 100% power, steady state, with all controls in AUTOMATIC.

The Pressurizer pressure channel (PT-455) selected for control fails LOW.

Based on these conditions, which of the following choices identifies how pressurizer temperature and pressurizer pressure will INITIALLY be affected with NO operator action?

PZR TEMPERATURE PZR PRESSURE A. INCREASES INCREASES B. INCREASES DECREASES C. DECREASES INCREASES D. DECREASES DECREASES Proposed Answer:

A Explanation of answer: A failure of the controlling PZR pressure channel will cause PZR heaters to energize which will result in an increase in PZR temperature and therefore pressure due to the controlling channel failure. The spray valves will not open to mitigate this pressure increase, therefore the volume of water in the PZR will also expand causing PZR pressure and temperature to continue to rise in their saturated environment until the plant trips on high pressure and the PORV opens. The question stem states INITIALLY.

Explanation of distractors: each distractor is incorrect because they have the wrong combination of parameter directional changes for initial impact of this failure.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

L1406i, Instrument Failure Analysis None Ability to monitor automatic operation of the PZR PCS including PZR Pressure.

55.41.5114 L1406102RO For the following plant instruments state where the parameter is sensed and list all uses for the associated channel.

L8027106RO Describe the auto control functions of the PZR pressure and level control system.

L8027114RO Explain the auto response of the plant including indications to the operator to a high or low failure of the PZR pressure and level control system.

~~

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 1

Question # 6 Group #

1 1

WA #

APE.022.AK3.03 Importance Rating 3.1 3.3 Proposed Question:

The following plant conditions exist:

The plant has been operating at 100% power for 300 days.

An NSO reports to the control room that charging line containment isolation valve CS-VI42 has a significant body to bonnet leak.

The Shift Manager directs the control room crew to isolate letdown and charging, and place excess letdown in service using the guidance of OS 1202.02, Charging System Failure.

Based on these conditions, why is excess letdown required?

A. To maintain constant reactor coolant system inventory.

B. To restore Volume Control Tank hydrogen control capability.

C. To provide a means of purifying reactor coolant by aligning flow through the mixed bed demineralizers.

D. To ensure an adequate cooling water flowrate through the reactor coolant pump seals while charging flow is isolated.

Proposed Answer:

A Explanation of answer: Without normal letdown in this situation there is no charging flowpath to the regenerative HX, excess letdown is required to maintain PZR level constant as it is designed to remove 20 gpm. This amount is exactly equal to seal injection flow that leaks into the RCS. Without excess letdown, PZR level would increase to 92% and the plant would eventually trip.

Explanation of distractors:

B - incorrect because although the return flowpath for excess letdown is to the suction of the charging pumps, there is little impact on the hydrogen capability of the VCT.

C - incorrect because the return flowpath in on the RCP seal return line which bypasses the demineralizers.

D - incorrect because seal injection can be supplied with charging isolated regardless of status of excess letdown. As long as thermal barrier HXs are supplied by PCCW, seal cooling can be provided with no seal injection.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

OS1202.02, Charging System Failure, CS Detailed Text, LP8024 None Knowledge of the reasons for performance of lineup to establish excess letdown after determining the need to isolate letdown as applied to loss of coolant makeup.

5.5.41.31518 L8024109RO Determine the flowrate in the following flowpaths that would be required to maintain a constant PZR level for any charging pump combination when provided with the letdown flowrate.

L1445111RO Summarize the major actions of OS1202.02.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 1

Question # 7 Group #

1 1

WA #

APE.025.AK2.02 Proposed Question:

Importance Rating 3.2 3.2 While operating with the Reactor Coolant System (RCS) in a mid-loop condition, the running Residual Heat Removal (RHR) pump shows signs of cavitation.

Which of the following statements is correct regarding the standby RHR pump?

The RHR Pump should A. NOT be immediately started because air entrainment could cause a loss of both RHR trains.

B. be immediately started because following a loss of RHR flow, an RCS pressurization may occur precluding gravity feed makeup.

C. be immediately started because under certain loss of RHR conditions, core uncovery or core voiding can OCCUI within 15 to 20 minutes.

D. NOT be immediately started because starting an idle RHR pump under mid-loop conditions could cause an unacceptable reduction in core shutdown margin.

Proposed Answer:

A Explanation of answer: The ARG provides a clear guidance which includes industry experience of why operation of an RHR pump operating with air entrapment should be evaluated because it could lead to pump damage. The AOP requires once indication of cavitation are experienced that both RHR pumps are placed in PTL. Starting the other RHR pump could transfer the problem to the other pump leading to a complete loss of the system.

Explanation of distractors:

B - incorrect because although gravity makeup is a required action, starting the RHR pump is not an option immediately.

C - incorrect because again while it is plausible that core uncovery or voiding could occur in a relatively short period of time, it is not correct that the RHR pump be started in this plant condition.

D-incorrect because although it is correct that the pump should not be started it is not correct that SDM would be affected in this condition since it was already verified procedurally to meet TS plant conditions.

Technical Reference(s):

OS 12 13.02 Loss of RHR at Reduced Inventory or Midloop Conditions.

ARG-1 for Loss of RHR At Midloop Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Bank#1318 Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

None Knowledge of the interrelationships between loss of RHR system and LPI or Decay Heat Removal/RHR Pumps.

55.41.3/5/10 L1705105RO Summarize the major actions of 081213.02.

Form ES-40 1-5 ES-40 1 Seabrook Written Examination Question Worksheet Examination Outline Cross-reference:

Level RO SRO Tier #

1 1

Question # 8 Group #

1 1

WA #

APE026AA2.06 Importance Rating 2.8 3.1 Proposed Question:

In accordance with OS1212.01, PCCW System Malhnction, which of the following is the time limit for tripping the reactor following a loss of Primary Component Cooling Water to the Reactor Coolant Pumps?

A. 2 minutes B. 5 minutes C. lominutes D. 13 minutes Proposed Answer:

C Explanation of answer: To prevent damage to the RCPs following a loss of PCCW it is procedurally required to trip the reactor and then RCPs following the E-0 immediate actions within 10 minutes to help preclude damage to the RCPs.

Explanation of distractors:

A,B - incorrect however plausible because they are both times associated with RCP coastdown to complete stop with and without RCPs running in the RCP malfunction abnormal. These numbers also are close enough to the other numbers such that they coincide well.

D - incorrect however plausible because it is the amount of time noted in the key cautions and notes of OS1201.01 that it will take seal water inlet temperature to approach 550 F following a loss of seal injection and thermal barrier flow.

Technical Reference(s):

OS1212.01, PCCW System Malfunction Proposed references to be provided to applicants during examination:

WA Topic:

Question History:

Bank #16013 Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

None Ability to determine and interpret the length of time after loss of PCCW flow to a component before that component may be damaged.

55.4 1.311 0 L1445101RO Identify the conditions requiring an emergency shutdown of an RCP as found in OS1212.01.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

Question # 9 Group #

1 1

WA #

012.K1.01 Importance Rating 3.4 3.7 Proposed Question:

Which one of the following supplies voltage for OPERATION of the SLAVE RELAYS in the Solid State Protection System (SSPS) output cabinets?

A. 48 VDC from a power distribution bus in the SSPS cabinets.

B. 120 VAC Vital Instrument Power from vital station inverters.

C. 15 VDC from redundant power supplies in the SSPS cabinets.

D. 120 VAC Vital Instrument Power from redundant inverters in the SSPS cabinets.

Proposed Answer:

B Explanation of answer: PP-lA,B,C,D (vital station inverters) provide 125VAC vital power to RPS slave relays.

Explanation of distractors:

D - incorrect because although 120 VAC is the source of power it is not derived from inverters in the SSPS cabinets themselves.

A & C - incorrect, however plausible because these supply power via redundant internal power supplies to SSPS electronics and trip and actuation output signals respectively Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Bank # 25192 Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

RP Detailed System Text.

None Knowledge of the physical connections andor cause effect relationships between the RPS and 120 VAC vitalhstrument power system.

55.41.7 L8056107RO State the function of the master and slave relays in RPS.

L1186108RO Describe the effect of a loss of EDE power panel IA or 1B on SSPS.

ES-401 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 1

Question # 10 Group #

1 1

WA #

EPE.029.EAl. 15 Importance Rating 4.1 3.9 Proposed Question:

The following plant conditions exist:

0 0

The crew is performing the actions of FR-S. 1, Response to Nuclear Power GeneratiodATWS initiated by a Loss of All Feedwater event.

In accordance with step 8, the operator is checking steam generator levels:

o o

o Narrow range levels for all steam generators are off-scale low.

Wide Range levels for all steam generators are approximateIy 62%.

Total Emergency Feedwater Flow (EFW) is 750 gpm.

Based on these conditions, what action should the crew take to control EFW flow?

A. Throttle feed flow to maintain reactor coolant system temperature.

B. Manually align valves and start pumps as necessary to increase EFW flow to greater than 880 gpm.

C. Maintain 500 gprn total feedwater flow until steam generator water level is greater than 65% wide range on at least two steam generators.

D. Maintain SO0 gprn total feedwater flow until steam generator water level is greater than 5% narrow range on at least one steam generator.

Proposed Answer:

B Explanation of answer: Step 8 of FR-S.l has a continuous action step to maintain > 880 gpm if narrow range level in at least one S/G is ~ 5 %

NR. This is to maintain secondary heat sink.

Explanation of distractors:

A - incorrect because the basis of step 8 is to ensure suficient EFW flow for decay heat removal during this event not to maintain RCS temperature. In an ATWS event RCS will rise and FTC will help shutdown the reactor.

C and D are incorrect yet plausible because they are criteria to maintain heat sink during E-0 versus FR-S. 1.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Bank # 23076 Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

FR-S. 1, Response to Nuclear Power GeneratiodATWS & associated ERG basis None Ability to operate and monitor AFW system as applied to an ATWS 55.4 1.10 L1200102RO Summarize the major actions of FR-S. 1.

~~

~

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 1

Question # 11 Group #

1 1

WA ##

EPE.038EA2.14 Importance Rating 3.3 4.6 Proposed Question:

Which of the following groups of initial conditions, assumptions, and failures were used in the Seabrook Steam Generator Tube Rupture Chapter 15 UFSAR Accident Analysis, resulting in the MOST SEVERE magnitude of radiological release?

RCS= Reactor Coolant System S/G= Steam Generator EFW= Emergency Feedwater Flow ASDV= Atmospheric Steam Dump Relief Valve RCS PRESSURE S/G LEVEL EFW FLOW ASDV FAILS A.

HIGH HIGH MAXIMUM OPEN B.

HIGH LOW MINIMUM OPEN

c.

LOW HIGH MAXIMUM OPEN D.

HIGH LOW MINIMUM SHUT Proposed Answer:

B Explanation of answer: According to Seabrook UFSAR, the combination of higher RCS initial pressure, Lower SIG Level, minimum EFW flow with the ADSV failing open will result in our worst case SGTR event resulting in the worst radiological consequences.

Explanation of distractors:

A, C & D are plausible because they contain elements of the UFSAR analyzed assumptions.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

KIA Topic:

Question Source:

Bank #24976 Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

L1414i SGTR TAA Lesson, Chapter 15.1 USFAR None Ability to determine or interpret the magnitude of atmospheric radioactive release if cooldown must be completed using steam dumps or if atmospheric reliefs lift as they apply to a SGTR.

55.41.5 L1414104RO Describe the two limiting SGTR events analyzed in the Seabrook specific analysis to include.......

Form ES-401-5 ES-40 1 Seabrook Written Examination Question Worksheet Examination Outline Cross-reference:

Level RO SRO Tier #

1 1

WA #

APE.040.GEN.2.4.4 Question ## 12 Group #

1 1

Importance Rating 4.0 4.3 Proposed Question:

Given the following plant conditions:

PARAMETER:

CURRENT VALUE:

Reactor power:

5 8%

RCS pressure:

2235 PSIG Auctioneered High Tavg:

569°F Turbine power:

595 MWE Containment pressure:

2 PSIG TREND:

Increasing Decreasing Decreasing Decreasing Increasing Based on the above plant indications, what event is occurring?

A. Steamline Break.

B. RCS Dilution Event.

C. Small Break RCS LOCA.

D. Steam Generator Tube Rupture.

Proposed Answer:

A Explanation: Reactor power is increasing, indicating positive reactivity event ("C" and "D" wrong). Electric load is decreasing, indicating loss of steam to the turbine. Also although a dilution event would add positive reactivity, it would result in an increase in RCS temperature vs. decrease. The fact that containment pressure is rising indicates the SLB is inside the containment ("A" correct, "B" wrong).

Technical Reference(s):

Proposed references to be provided to applicants during examination:

E-2 ERG Description of SLB Event None WA Topic:

Question History:

New Ability to recognize abnormal indications for system operating parameters which are entry-level conditions for emergency and abnormal operating procedures as applied to Steam Line Rupture.

Question Cognitive Level:

Higher 10 CFR Part 55 Content:

55.41.5 Learning Objective:

L12075101RO Recognize symptoms or entry conditions for E-2.

L1202109RO State the criteria as found in E-0 for transition to E-2.

Seabrook Written Examination Question Worksheet Form ES-40 1-5 ES-401 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

WA #

022.GEN2.1.33 Importance Rating 3.4 4.0 Question # 13 Group #

1 1

Proposed Question:

Which of the following identifies the normal operating containment internal pressure band in accordance with Technical Specification 3.6.1.4, Primary Containment Internal Pressure?

A. 12.6 to 14.6 psia B. 14.6 to 16.2 psia C. 16.2 to 18.6 psia D. 18.2 to 20.2 psia Proposed Answer:

B Explanation of answer: ROs are required to know from memory < 1 hr required action statements. TS 3.6.1.4 is part of TS required logs and should be controlled within a narrow band so that we do not exceed containment pressure on design basis accidents. The band for Seabrook according to TS is 14.6 to 16.2 psia.

Explanation of Distractors: A,C, & D are incorrect because they do not correspond with TS required value, however they are plausible because of their close proximity to the actual value.

Technical Reference(s):

TS 3.6.1.4 Proposed references to be provided to applicants during examination:

WA Topic:

Technical Specifications.

Question Source:

Bank #24420 Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

None Ability to recognize indications for system operating parameters which are entry level conditions for 55.41.10 L8038105aRO State from memory and apply the LCO and actions for the following TS: 3.6.1.4

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 1

Question # 14 Group A+

1 1

WA #

APE.058.AKI.01 Importance Rating 2.8 3.1 Proposed Question:

The following plant conditions exist:

0 The plant is operating at 100% power.

Following a crew brief, Technical Specification action statements have been entered to transfer 125 VDC Bus 11A to its normal battery supply in accordance with 081048.13, Vital Bus 11A Operation.

Due to a human performance error, the Nuclear Systems Operator missed several procedure steps and failed to note that battery charger (1-EDE-BC-1A) was NOT connected to DC Bus 11A.

The alternate battery supply breaker was then opened.

0 Given these conditions what operational implications are a direct result of these actions?

A. Loss of Turbine Trip Control.

B. Loss of Normal Feedwater Control.

C. Loss of Emergency Diesel Generator Stop Capability.

D. Loss of Pressurizer Power Operated Block Valve Control.

Proposed Answer:

B Explanation of answer: These conditions are outlined as a caution in 081048.13 and result in a Loss of Vital Bus 11A.

As a result of this bus loss, Feedwater Control is lost and will result in a plant trip.

Explanation of distractors:

A - Incorrect because this would be a result of non-vital DC bus loss.

C - Incorrect because the loss of DC Bus 1 1A results in a loss of start capability vs. stop capability.

D - Incorrect because the PORV Block valve is unaffected, however the PORV itself is.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Loss of DC Power.

Question Source:

New Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

OS1248.01, Loss of Vital 125VDC Bus, OS 1048.13, Vital Bus 11A Operation None Knowledge of the operational implications of battery charger equipment and instrumentation as applied to 55.4 1.71 10 L1189115RO Describe the effects of losing Vital DC Power on the following equipment......

L8020123RO Describe the importance of 125VDC power for the proper auto operation of the EDG and EPS.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 1

Question # 15 Group #

1 1

WA #

APE.062.GEN.2.4.11 Importance Rating 3.4 3.6 Proposed Question:

The following plant conditions and sequence of events are provided:

The plant is operating at 100% power in a normal at power configuration.

A Tower Actuation (TA) signal is received on BOTH trains.

The control room crew enters OS1216.01, Degraded Ultimate Heat Sink and verifies Tower Actuation is properly aligned.

Based on these plant conditions, what Service Water System loads have isolated?

A. EDG Heat Exchangers.

B. PCCW Heat Exchangers.

C. SCCW Heat Exchangers.

D. Control Room Chillers.

Proposed Answer:

C Explanation of answer: With the conditions given, the operator must recognize that actuation of both TA trains will shut both SW-V-4 & 5, isolating both trains of SCCW cooling from Turbine Building loads. If prompt response is not taken once in the AOP, this will lead to EOP entry due to Turbine overheating concerns. With a normal TA system realignment, the cooling tower pumps have started and are providing cooling to the EDGs and PCCW systems which eliminates the other two plausible Service Water Cooled loads in choices A & B. Choice D is incorrect because the control room chillers are cooled by a separate stand alone system which is unaffected by a SW loss.

Technical Reference( s):

Proposed references to be provided to applicants during examination:

KIA Topic:

Question Source:

New Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

OS 1216.01, Degraded Ultimate Heat Sink, SW Detailed System Text. Detailed Systems Summary Setpoints Handout None Knowledge of abnormal operating procedures as applied to Loss of Nuclear Service Water.

55.4 1.4/10 L1193102RO Summarize the major actions of OS1216.01.

L8037I 13RO List the auto actions which will occur upon initiation of TA signal.

ES-40 1 Seabrook Written Examination Question Worksheet FOIIII ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 1

Question # 16 Group ##

1 1

WA #

APE.065.AAl.03 Importance Rating 2.9 3.1 Proposed Question:

With the plant at 100% power, a significant instrument air leak occurs, and the following sequence of events occurs:

Air pressure starts to drop at a Moderate rate and the crew enters 081242.01, Loss of Instrument Air.

A Nuclear System Operator reports that the leak location has been found, and the leak can be isolated.

The leak is isolated, and instrument air pressure recovers from 70 psig to 110 psig prior to meeting any reactor trip criteria.

The Balance of Plant Operator notes that due to the loss of air the C Circulating Pump has tripped on High Screen Differential.

Which one of the following procedures will address this set of plant conditions?

A. OS 1242.0 1, Loss of Instrument Air.

B. 081233.01, Loss of Condenser Vacuum.

C. 081234.02. Condenser Tube or Tube Sheet Leak.

D. OS 1290.02, Response to Condensate or Feedwater Heater System Transient Proposed Answer:

B Explanation of answer: As demonstrated by actual plant events, the circ pump house is the first effected by a loss of IA.

The degraded air supply prior to restoration caused a failure of the traveling screen DP instrument (bubbler), causing the circ pump to trip. The operator must equate th~s failure with a Loss of Condenser Vacuum, which would occur as a result of the circ water pump trip. Entry conditions for the drop in condenser vacuum as a result of the pump trip would be met and therefore it is expected that this procedure is entered. Failure to take action would result in a plant trip.

Explanation of distractors:

A - Incorrect because remaining in this procedure will not address this problem. It is more designed to provide reactor trip criteria based on loss of air versus once air pressure is restored.

C & D - Incorrect because although they might have some system association making them plausible, they are designed to handle other problems and would not be correct choices for entry.

Technical Reference(s):

081242.01, Loss of Instrument Air & other procedure cover sheets for referenced procedures.

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

None Ability to operate and/or monitor the restoration of systems served by instrument air when pressure is regained as they apply to the Loss of Instrument Air.

55.41.4/10 L1194104RO Describe how a loss of IA will effect the following systems......

L1194102RO Summarize the major actions of OS1 242.01.

~~

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 1

Question # 17 Group #

1 1

K/A #

W/E05.EK3.3 Importance Rating 4.0 4.1 Proposed Question:

Given the following plant conditions and sequence of events:

0 0

The crew is combating a Loss of Secondary Heat Sink in accordance with FR-H.l, Loss of Secondary Heat Sink Reactor Coolant System (RCS) pressure is 1200 psig.

Bleed and feed has b en established with all Emergency Core Cooling System pumps in service and both Pressurizer Operatebelief Valves (PORVs) open.

Reactor Coolant Pumps are NOT running.

Wide range levels are < 5% in all steam generators.

RCS hot leg temperatures on all loops are 560 F and slowly dropping.

The crew is about to re-establish feedwater flow to the D steam generator.

0 Based on these conditions, which of the following describes the flow rate that should be established to the D steam generator and the reason for the flow rate?

A. Feed at the maximum rate to mitigate the potential for core damage.

B. Feed at the minimum rate to minimize thermal stress on steam generator components.

C. Feed at the maximum rate to depressurize the RCS and facilitate accumulator injection.

D. Feed at the minimum rate to minimize RCS cooldown rate and RCS pressurized thermal shock.

Proposed Answer:

B Explanation of answer: To comply with the caution prior to step 2 1 of FR-H. 1, since feed and bleed has been established and RCS temperatures are dropping in a dry S/G, operators are directed to feed at a minimum rate.

Explanation of distractors:

A & C - incorrect because they prescribe feeding at the maximum rate which would be applicable if RCS temperature were increasing and the SIG was dry.

D - incorrect because the concern is steam generator damage versus cooldown/PTS which is plausible during other accidents.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic: Knowledge of the reasons for manipulation of controls required to obtain desired operating results during Question Source:

Bank #23077 Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

FR-H. 1, Response to Loss of Secondary Heat Sink Caution prior to step 2 1 and associated background document.

None abnormal and emergency situations as applied to a Loss of Heat Sink.

55.41.10 L12111.02RO Summarize the major actions of FR-H. 1 L1211103RO State the basis for the caution, steps, and notes from FR-H.I.

L1420104RO Describe the effectiveness of the following analyzed techniques for maintaining adequate core cooling I response to a loss of all feedwater event: EFW flow restoration.

~~

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level Tier #

Question # 18 Group #

RO SRO 1

1 1

1 WA #

WiEl 1.EK1.1 Importance Rating 3.7 4.0 Proposed Question:

A Loss of Coolant Accident has occurred and the crew is now responding to a Loss of Emergency Coolant Recirculation. The crew has initiated Reactor Coolant System cooldown to cold shutdown, and they have checked conditions to determine spray requirements.

The following plant conditions exist:

0 0

0 Based on these conditions, which of the following statements describes the actions necessary in accordance with ECA-1.1, LOSS of Emergency Coolant, to meet CBS system alignment requirements at this time?

Two containment building spray (CBS) pumps are running.

CBS pump suctions are aligned to the Refueling Water Storage Tank (RWST).

RWST level is 250,000 gallons.

Containment Building Level is 3 feet.

Containment pressure is 12 psig.

A. Stop the two CBS pumps.

B. Stop one CBS pump, and leave running pump aligned to the RWST.

C. Stop one CBS pump, and align running pump to the containment sump.

D. Leave both CBS pumps running and align to the containment sump.

Proposed Answer:

A Explanation of answer: Based on ECA-1.1, with CBS pumps aligned to the RWST and containment pressure < 18 psig, no CBS pumps are needed to mitigate high containment pressure and the priority shifts to conserving RWST volume.

Explanation of distractors:

B-Step 1 1 of ECA-1.1 determines the minimum spray requirements based on containment pressure. Since containment pressure is not between 18 - 52 psig, this answer is incorrect.

C - Again this answer part 1 of this answer is plausible if containment pressure were between 18 -52 psig, aligning to the containment sump is incorrect.

D-This is plausible if containment pressure is > 52 psig, again aligning to the containment sump is incorrect.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Emergency Coolant Recirculation.

Question Source:

Bank #18888 Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

ECA 1.1, Loss of Emergency Coolant Recirculation and associated background.

None Knowledge of the operational implications of components, capacity, and function as applied to Loss of 55.41.10 L1209102RO Summarize the major actions of ECA-I. I.

LI 209103RO State the basis for steps, notes and cautions of ECA-I. 1.

L121210SRO State the basis for the steps, notes and cautions of FR-Z.1: caution prior to step 2 (if ECA-I. 1 is in effect, containment spray should be operated as directed in ECA-I. I rather than step 2 below.

ES-401 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 1

Question # 19 Group #

2 2

WA #

APE.003.AK1.03 Importance Rating 3.5 3.8 Proposed Question:

Given the following plant conditions:

0 0

0 0

The plant is at 100% power at End of Life.

Control Bank D rods are at 228 steps.

ONE of the Bank D rods drops indicating it is on the bottom of the core.

The reactor does NOT trip and no operator action is taken.

Based on these conditions, which of the following best represents the expected response to the dropped rod?

Final Reactor Power Tave A. Same as Initial Lower B. Lower Lower C. Lower Same as Initial D. Same as Initial Same as Initial Proposed Answer:

B Explanation of answer: Reactor power initially prompt drops due to instantaneous insertion of negative reactivity into the core. The resultant drop in Tavg will insert positive reactivity into the core, Since no control rod motion will occur with rods full out, reactor power will return to near its original value with Tavg lower to offset the negative worth of the rod insertion. Power returns to a value slightly lower also due to a lower Tavg and lower S/G pressure and also because the greater worth of the entire bank. Reactor power follows steam demand.

Explanation of distractors:

All distractors are plausible but incorrect because they contain an aspect of the correct answer with combinations that discriminate between competent and less competent operators.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Knowledge of the operational implications of the relationship of reactivity and reactor power to rod Topic:

movement as applied to a Dropped Rod.

Question Source:

Modified Bank #20449 Original question attached to reference.

Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

UFSAR Section 15.4 on dropped rods.

None 55.4 1.m L1185101 RO Recognize the entry conditions for Dropped Rod.

L1410105RO Describe the response of the RCS to a dropped rod accident.

Seabrook Written Examination Question Worksheet Form ES-40 1-5 ES-401 Examination Outline Cross-reference:

Level RO SRO Tier #

1 1

WA #

APE.028.AA1.08 Importance Rating 3.7 3.6 Question I# 20 Group #

2 2

Proposed Question:

The following plant conditions exist:

0 0

0 The plant is operating at 100% power.

All Control Systems are in a normal alignment.

Pressurizer (PZR) level channel LT-460 fails LOW Based on these plant conditions, select the action, if any, that should be performed by the crew to reopen RC-LCV-460 (Letdown Isolation Valve)?

A. Select channel 459/461 for control, then open RC-LCV-460.

B. Select channel 461/460 for control, then open RC-LCV-460.

C. No action required, RC-LCV-460 will not close on this failure.

D. Select channel 459/461 for control, open CS-V145, then open RC-LCV-460.

Proposed Answer:

A Explanation of answer: Normally Channel LT-459 which is the controlling channel and pushbutton 459/460 is selected on the MCB. When LT-460 fails low, the associated letdown isolation valve receives a signal and isolates letdown. The crew will enter the AOP for this failure (OS1201.07) which directs an alternate channel to be selected and then restoration of letdown.

Explanation of distractors:

B-incorrect but plausible since this channel would be the incorrect channel.

C-incorrect but plausible if the student is not aware of the interlock associated with this valve. LT-459 provides an input to RC-LCV-459 and LT-460 provides an input to RC-LCV-460.

D-incorrect but plausible since it has the correct selector switch, but incorrect interlock. The interlock is plausible still however, because in order to open RC-LCV-459 & 460, CS-V145 must be closed.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

KIA Topic:

Question Source:

Bank #18971 Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

RC PZR Press & Level Control Functional 1-NHY-509051/0S1201.07, PZR Level Failure AOPPPLC Detailed System Text None Ability to operate and/or monitor the selection of an alternate PZR level channel if one has failed as applied to PZR level control malfunctions.

55.4 1.7/10 L8027105RO Describe the function of any PZR pressure or level control system, indication or control on the MCB.

L8027106RO Describe the Auto control functions of the PZR Pressure and level control system.

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 1

Question # 21 Group #

2 2

WA #

APE.032.GEN.2.1.20 Importance Rating 4.3 4.2 Proposed Question:

Given the following conditions:

0 A reactor startup is in progress with the reactor just critical in accordance with OS1000.07, Approach to Criticality.

The operator has just stopped moving control rods.

Power slowly increases above 1 x 10. amps.

ONE source range (SR) nuclear instrumentation channel (N-3 1) fails LOW.

0 0

0 Remaining power indications stabilize.

In accordance with Technical Specification 3.3.1 (provided), which of the following actions, if any, is required?

A. No action required, source range not required to be operable.

B. Trip the reactor and enter E-0, Reactor Trip andor Safety Injection.

C. Conduct a reactor shutdown and restore both SR channels to operability prior to next startup.

D. Suspend all operations involving positive reactivity changes until both SR channels are restored to operability.

Proposed Answer:

A Explanation of answer: TS 3.3.1(instrumentation) establishes that above P-6, the SR NI are not required by TS and will shortly be de-energized by procedure. Since there are no TS implications, the startup may proceed.

Explanation if distractors:

B - incorrect because no entry conditions are met for a reactor trip. (plausible misconception)

C - incorrect because a plant shutdown is not required unless both SR channels are lost during reactor startup.

D - incorrect because SR channels can be blocked. Reactor power is above P-6. This statement would be correct if reactor power was < P-6.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

TS 3.3.1 & OS1000.07, Approach to Criticality TS 3.3.1 is provided as a reference.

WA Topic:

Question Source:

Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

Ability to execute procedure steps as related to a Loss of Source Range NI.

Modified Bank # 6926 Original question attached to reference.

55.41.6/10 L8030I 12R0 Given a copy of TS locate applicable LCOs and list the applicable action statements for stated excore nuclear instrumentation channel failures.

314.3 INSTRUMENTATION 314.3.1 REACTOR TRIP SYSTEM INSTRUMENTATION LIMITING CONDITION FOR OPERATION 3.3.1 of Table 3.3-1 shall be OPERABLE.

As a minimum, the Reactor Trip System instrumentation channels and interlocks APPLICABILITY: As shown in Table 3.3-1.

ACT1 0 N:

As shown in Table 3.3-1.

SURVEILLANCE REQUIREMENTS 4.3.1.I automatic trip logic shall be demonstrated OPERABLE by the performance of the Reactor Trip System Instrumentation Surveillance Requirements specified in Table 4.3-1.

Each Reactor Trip System instrumentation channel and interlock and the 4.3.1.2 The REACTOR TRIP SYSTEM RESPONSE TIME of each Reactor trip function shall be verified to be within its limit at least once per 18 months. Each verification shall include at least one train such that both trains are verified at least once per 36 months and one channel per function such that all channels are verified at least once every N times 18 months where N is the total number of redundant channels in a specific Reactor trip function as shown in the "Total No. of Channels" column of Table 3.3-1.

I u

u SEABROOK - UNIT 1 314 3-1 Amendment No. 84

TABLE 3.3-1 REACTOR TRIP SYSTEM INSTRUMENTATION MINIMUM TOTAL NO.

CHANNELS CHANNELS APPLICABLE FUNCTIONAL UNIT OF CHANNELS TO TRIP OPERABLE MODES ACTION

1.

Manual Reactor Trip 2

1 2

1,2 1

2 I

2 3*, 4*, 5*

I O

2.

Power Range, Neutron Flux

a. High Setpoint
b. Low Setpoint High Positive Rate
3.

Power Range, Neutron Flux 4

2 3

192 2

4 2

3 I # # #, 2 2

4 2

3 132 2

4.

(NOTUSED)

5.

Intermediate Range, Neutron Flux 2

1 2

I # # #, 2 3

6.

Source Range, Neutron Flux

a. Startup
b. Shutdown
c. Shutdown
7.

Overtemperature AT 2

1 2

2# #

4 2

0 1

31 41 5 5

2 I

2 3*, 4*, 5*

10 4

2 3

192 6

8.

Overpower AT 4

2 3

182 6

9.

Pressurizer Pressure-Low 4

2 3

1 **

6 I O.

Pressurizer Pressure-High 4

2 3

1 1 2 6

11. Pressurizer Water Level-High 3

2 2

1 **

6#

SEABROOK -UNIT I 314 3-2 Amendment No. 36, 91

FUNCTIONAL UNIT 12 1 3.

1 4.

1 5.

16.
17.

I

8.

Reactor Coolant F l o w 4 o w

a. Single Loop (Above P-8)
b. Two Loops (Above P-7 and below P-8)

Steam Generator Water L eve1 --Lo w-Lo w Undervoltage--Reactor Coolant Pumps

(

TABLE 3.3-1 (Continued)

REACTOR TRIP SYSTEM INSTRUMENTATION TOTAL NO.

OF CHANNELS 4/stm. gen.

4-2h1.1~

Underfrequency-Reactor Coolant 4-2hus Pumps Turbine Trip

a. Low Fluid Oil Pressure 3
b. Turbine Stop Valve Closure 4

Safety Injection Input from ESF 2

Reactor Trip System Interlocks

a. Intermediate Range Neutron Flux, P-6 2

MINIMUM CHANNELS CHANNELS APPLICABLE TO TRIP OPERABLE MODES ACTION 2Aoop in any oper-ating loop 2Aoop in two oper-ating loops 2lstm. gen.

in any oper-ating stm.

gen.

2-1 /bus 2Aoop in 1

6#

each oper-ating loop 2Aoop I

6#

each oper-ating loop 3lstm. gen.

1, 2 6

each oper-ating stm.

gen.

2 on one bus I 6

2-1 /bus 2 on one bus 1 **

6 2

2 1 ***

6#

4 4

1 ***

11 1

2 192 7

1 2

2# #

a SEABROOK -UNIT I 3/4 3-3 Amendment No. 36

FUNCTIONAL UNIT

18. b. Low Power Reactor Trips Block, P-7 P-I 0 Input P-I 3 Input or
c. Power Range Neutron Flux, P-8
d. Power Range Neutron Flux, P-9
e. Power Range Neutron Flux, P-IO
f. Turbine Impulse Chamber Pressure, P-I 3
19. Reactor Trip Breakers
20.

Automatic Trip and Interlock Logic TABLE 3.3-1 (Continued)

REACTOR TRIP SYSTEM INSTRUMENTATION TOTAL NO.

OF CHANNELS 4

2 4

4 4

MINIMUM CHANNELS CHANNELS APPLICABLE TO TRIP OPERABLE MODES ACTl ON 2

3 1

1 2

1 3

3 3

2 2

2 2

2 1

1 1

1 I f 2 3*, 4*, 5*

192 3*, 4*, 5" 8

8 8

8 8

8 9, 12 10 7

10 SEABROOK -UNIT 1 314 3-4 Amendment No. 36

TABLE 3.3-1 (Continued)

TABLE NOTATIONS When the Reactor Trip System breakers are in the closed position and the Control Rod Drive System is capable of rod withdrawal.

Trip function automatically blocked or bypassed below the P-7 (At Power)

Setpoint.

Trip function automatically blocked below the P-9 (Reactor Tripnurbine Trip Interlock) Setpoint.

  1. The provisions of Specification 3.0.4 are not applicable.
  1. #Below the P-6 (Intermediate Range Neutron Flux Interlock) Setpoint.
  1. # #Below the P-IO (Low Setpoint Power Range Neutron Flux Interlock) Setpoint.

ACTION STATEMENTS ACTION 1 - With the number of OPERABLE channels one less than the Minimum Channels OPERABLE requirement, restore the inoperable channel to OPERABLE status within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> or be in HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

ACTION 2 - With the number of OPERABLE channels one less than the Total Number of Channels, STARTUP and/or POWER OPERATION may proceed provided the following conditions are satisfied:

a. The inoperable Channel is placed in the tripped condition within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />,
b. The Minimum Channels OPERABLE requirement is met; however, the inoperable channel may be bypassed for up to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> for surveillance testing of other channels per Specification 4.3.1.1, and
c. Either, THERMAL POWER is restricted to less than or equal to 75% of RATED THERMAL POWER and the Power Range Neutron Flux Trip Setpoint is reduced to less than or equal to 85% of RATED THERMAL POWER within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />; or, the QUADRANT POWER TILT RATIO is monitored at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> per Specification 4.2.4.2.

SEABROOK - UNIT 1 314 3-5 Amendment No. 36

L.

ACTION 3 -

ACTION 4 -

ACTION 5 -

ACTION 6 -

ACTION 7 -

ACTION 8 -

TABLE 3.3-1 (Continued)

ACTION STATEMENTS (Continued)

With the number of channels OPERABLE one less than the Minimum Channels OPERABLE requirement and with the THERMAL POWER level:

a. Below the P-6 (Intermediate Range Neutron Flux Interlock) Setpoint, restore the inoperable channel to OPERABLE status prior to increasing THERMAL POWER above the P-6 Setpoint, and
b. Above the P-6 (Intermediate Range Neutron Flux Interlock) Setpoint but below 10% of RATED THERMAL POWER, restore the inoperable channel to OPERABLE status prior to increasing THERMAL POWER above 10%

of RATED THERMAL POWER.

With the number of OPERABLE channels one less than the Minimum Channels OPERABLE requirement, suspend all operations involving positive reactivity changes.

With the number of OPERABLE channels one less than the Minimum Channels OPERABLE requirement, restore the inoperable channel to OPERABLE status within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> or open the Reactor Trip System breakers, suspend all operations involving positive reactivity changes and verify that valve RMW-V31 is closed and secured in position within the next hour.

With the number of OPERABLE channels one less than the Total Number of Channels, STARTUP and/or POWER OPERATION may proceed provided the following conditions are satisfied:

a. The inoperable channel is placed in the tripped condition within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, and
b. The Minimum Channels OPERABLE requirement is met; however, the inoperable channel may be bypassed for up to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> for surveillance testing of other channels per Specification 4.3.1.1.

With the number of OPERABLE channels one less than the Minimum Channels OPERABLE requirement, restore the inoperable channel to OPERABLE status within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> or be in a least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />; however, one channel may be bypassed for up to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> for surveillance testing per Specification 4.3.1.I

, provided the other channel is OPERABLE.

With less than the Minimum Number of Channels OPERABLE, within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> determine by observation of the associated permissive annunciator window(s) that the interlock is in its required state for the existing plant condition, or apply Specification 3.0.3.

L SEABROOK - UNIT 1 314 3-6 Amendment No. 36

~

ES-401 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 1

Question # 22 Group #

2 2

WA #

APE.059.AA2.05 Importance Rating 2.9 3.6 Proposed Question:

The following plant conditions exist:

0 A release from the B Waste Test Tank is in progress at 45 gpm in accordance with ON1018.09, WASTE TEST TANK B DISCHARGE TO TRANSITION STRUCTURE.

RDMS channel R-6509, (1LM621), Liquid Waste Tank To CW System, goes into HIGH alarm.

0 Based on these conditions, which of the following is correct?

A. 1-WL-FCV-1458-1, high capacity waste distillate to discharge structure valve closes and AUTO reopens when high radiation condition clears.

1-WL-FCV-1458-1, high capacity waste distillate to discharge structure valve closes and must be MANUALLY reopened when high radiation condition clears.

1-WL-FCV-1458-2, low capacity waste distillate to discharge structure valve closes and AUTO reopens when high radiation condition clears.

D. 1-WL-FCV-1458-2, low capacity waste distillate to discharge structure valve closes and must be MANUALLY reopened when high radiation condition clears.

B.

C.

Proposed Answer:

B Explanation of answer/distractors: 1458-1, is used when the release rate is greater than 20 gpm and 1458-2 is for releases at less than 20 gpm. When radiation monitor 1 LM62 1 goes into high alarm the release is terminated by closing the discharge valve. In this case, it would be 1458-1.

A - incorrect because a modification was added to require manual operation prior to reopening of either valve so that an inadvertent release does not occur.

C & D - incorrect because the release rate 45 gpm, therefore, 1458-1 will be used and 1458-2 not.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Bank #22622 Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

OS1252.01, Process or Effluent High Radiation UFSAR Figure 11.2.4, N1319i Test Tank & Discharges None Ability to operate/monitor the occurrence of automatic safety actions as a result of a high PRM system signal as applied to Accidental Liquid Radwaste Release.

55.41 3 1 0 L1187102RO Summarize the major actions of 081252.01.

L8059106RO Describe the auto actions that result when the below listed monitors reach their specified setpoints.......

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO

~

Tier #

1 1

Question # 23 Group I#

2 2

WA #

W/E09.GEN.2.4.12 Importance Rating 3.4 3.9 Proposed Question:

The crew is verifying natural circulation in ES-0.1, Reactor Trip Response The following conditions exist:

Reactor Coolant System (RCS) Wide Range (WR) Thot is 580 F and stable.

RCS WR Tcold is 555 F and stable.

RCS pressure is 1920 psig and stable.

Core Exit Thermocouples are 585 F and stable.

Steam Generator (S/G) pressure is 1090 psig and stable.

S/G WR level is 70% in all S/Gs and stable.

Emergency Feedwater flow is 400 gpm to each S/G.

Based on these plant conditions, which one of the following describes the status of natural circulation which will determine subsequent crew operating responsibilities?

A. All conditions are met, natural circulation is established.

B. Natural circulation is NOT established, heat sink is insufficient.

C. Natural circulation is NOT established, subcooling is insufficient.

D. Natural circulation is NOT established, RCS delta T is insufficient.

Proposed Answer:

A Explanation of answer: All of the conditions of Attachment F of ES-0.1, so therefore natural circulation conditions are met.

Explanation of distractors:

B & D are incorrect because heat sink and DT although required for natural circulation to exist are not part of the criteria to verify these support conditions.

C is incorrect because subcooling is > 40 F based on calculations using steam tables.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Bank #5299 Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

ES-0.1, Reactor Trip Response Attachment F Steam Tables/ Mollier Diagram Knowledge of general operating responsibilities during emergency operations.

55.41.5/10 L1225104RO Summarize the major actions of ES-0.1.

L1225108RO State the five parameters used to verify natural circulation flow as listed in attachment F of ES-0.1.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 1

Question # 24 Group #

2 2

WA #

WIE 10.EA2.1 Importance Rating 3.2 3.9 Proposed Question:

The following plant conditions exist:

The unit has tripped from 100% power when a switchyard failure caused a loss of offsite power.

ES-0.2, Natural Circulation Cooldown is in progress to perform a natural circulation cooldown and depressurization of the reactor coolant system (RCS).

For which one of the following situations should a transition to ES-0.3, Natural Circulation Cooldown with Steam Void in Vessel (with RVLIS) occur?

A. The Safety Injection accumulators are unable to be isolated.

B. Auxiliary Pressurizer Spray becomes unavailable for use in depressurizing the RCS.

C. NO Reactor Coolant Pumps will be able to be restarted prior to cooling down the plant to < 200 F.

D. A required high rate of plant cooldown and depressurization results in less than 100% level in the reactor vessel head.

Proposed Answer:

D Explanation of answer: In accordance with ES-0.2, the note prior to step 12 and also at step 15, the criteria has been met to transition to ES-0.3.

Explanation of distractors:

A is incorrect because during all natural circulation procedures, the SI accumulators are isolated.

B is incorrect because although aux spray is available, it is not a reason for transition.

C is incorrect because if RCPs are restarted in this procedure there is no longer a natural circulation issue and transition back to normal operating procedures is directed.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

ES-0.2, Natural Circulation Cooldown None Ability to determine and interpret facility operations and selection of appropriate procedures during abnormal and emergency operations as applied to Natural Circulation with Steam Void in Vessel withiwithout RVLIS.

55.41310 L1225106RO Summarize the major actions of ES-0.2.

Seabrook Written Examination Question Worksheet Form ES-40 1-5 ES-40 1 Examination Outline Cross-reference:

Level RO SRO Tier #

1 1

WA #

WIE14.EK3.2 Question # 25 Group #

2 2

Importance Rating 3.1 3.7 Proposed Question:

Which of the following correctly describes why the Containment Functional Restoration Procedure (FR-Z. 1) is different from all other Functional Restoration Procedures?

The Containment Functional Restoration Procedure A. is entered on Unit Supervisor judgement based on plant conditions.

B. assumes both trains of containment building spray are operating to ensure a success path.

C. is considered a dual function guideline because it addresses both orange and red path conditions within the same guideline.

D. provides no alternate method to reduce containment pressure other than to restore normal containment cooling methods.

Proposed Answer:

D Explanation of answer: Per lesson 1422i and background documents for FR-Z.1 there is no alternative success path to lower containment pressure if normal methods are not available. This makes FR-Z. 1 unique.

Explanation of distractors:

A - incorrect because this statement is contrary to rules of usage according to OP 9.2. Containment FRP has higher than yellow path entry conditions which are required to be entered based on rules of usage. The FRP is not unique in this respect.

B - incorrect because like most EOPs they assume one train only with two being preferable. The FRPs are beyond design bases so therefore seeks to reduce containment pressure with whatever CBS pumps are available.

C - incorrect because FR-S. 1, FR-P. 1 are also dual hnction FRPs so therefore it is not unique in this respect.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Bank #16072 Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

OP-9.2 EOP Users Guide, FR-Z. 1, Response to High Containment Pressure, LP 14221 None Knowledge of the reasons for normal, abnormal and emergency operating procedures associated with High Containment Pressure.

55.41.10 L1422104RO Describe the basic difference between the operator actions of FR-Z. 1 and those of other functional restoration procedures.

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 1

Question # 26 Group #

2 2

WA #

WiE15.EK1.3 Importance Rating 2.8 3.0 Proposed Question:

Given the following plant conditions:

With the plant initially at 100% power, a large break LOCA occurs in Containment resulting in Phase A & B isolation.

Based on Containment Building Level > 5 feet, the crew has entered FR-Z.2, Response To Containment Flooding, and is trying to identify and isolate the sources of water to the CTMT sump per FR-Z.2 step 1.

The Reactor Operator (RO) has been directed to check the Reactor Makeup Water (RMW), Primary Component Cooling Water (PCCW), and Fire Protection (FP) systems as potential water sources into Containment.

How will the RO check these three paths, and which of these paths, if any, would still need to be isolated from Containment?

A. The Containment isolation valves for all three systems can be verified closed on the A Main Control Board front section. All three paths should already be isolated.

B. The RMW and PCCW isolation valves can be verified on the Main Control Board. The FP path can only be verified locally. All three paths should already be isolated.

C. The Containment isolation valves for all three systems can be verified closed on the A Main Control Board front section. The RMW System still needs to be isolated.

D. The RMW and PCCW isolations can be verified on the Main Control Board. The FP path can only be verified locally and would require local operator action to isolate.

Proposed Answer:

B Explanation of answer: FR-Z.2, step 1 has the operator identify unexpected sources of water to the containment sump.

Only the RMW and PCCW isolations can be operated from the MCB. It should be recognized that most containment isolation valves which are manual and cannot be operated from the control room are normally closed valves unless open under administrative controls. There is no control room indication of FP valves. Note that this scenario was encountered during the 2004 graded E-Plan exercise.

Explanation of distractors:

A - incorrect because although RMW and PCCW can be verified on the MCB, FP cannot.

C - incorrect because of the same reason above. Additionally, RMW-V-30 closed on Phase A isolation.

D - incorrect because the FP is already isolated. The first portion of the answer is plausible since it is correct.

Technical Reference( s):

FR-Z.2, Response to Containment Flooding.iOX0443.75, Establishing Containment Fire Protection.

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

None Knowledge of the operational implications of annunciators and condition indicating signals and remedial actions associated with Containment Flooding.

55.4 1.415.10 L 12 121 1 OR0 Summarize the major actions of FR-Z.2.

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level Tier #

Question #i 27 Group #

WA #

RO SRO 1

1 2

2 W/E 16.EK2.1 Importance Rating 3.O 3.3 Proposed Question:

FR-Z.3, Response to High Containment Radiation Level, (step 2) checks if the containment recirculation filter should be placed in service. Why is containment pressure verified less than 18 psig?

A. The P signal will prevent the containment recirculation filter fans, FN-3A and FN-3B, from starting.

B. The P signal will prevent the containment recirculation filter system realignment to the Filter Mode.

C. The radioactive release associated with a containment pressure of 18 psig exceeds the limits of the recirculation filter capability.

D. Containment pressure greater than 18 psig could damage the recirculation filter dampers when they are realigned to the Filter Mode.

Proposed Answer:

B Explanation of answer: The P signal or Phase B isolation realigns dampers to recirculation Mode, bypassing the filter at I8 psig.

Explanation of distractors:

A - incorrect because the P signal is what actually starts the fans. The P signal occurs at 18 psig.

C - incorrect and could be a common misconception.

D - incorrect because although potentially plausible that this pressure could cause damage, the logics prevent this from happening because it is not possible to realign to filter Mode until interlock is satisfied.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

FR-Z.3, Response to High Containment Radiation, CHV Detailed System Text (4.1.3)

None Knowledge of the interrelationships between High Containment Radiation and components, finctions of control and safety systems, including instrumentation, signals, interlocks, failure Modes, and automatic and manual features Bank #22288/ 2003 NRC Exam 55.41.7/10 L1212112RO Summarize the major actions of FR-Z.3 L8038104RO Describe the response of the CAH components to the following protective actions signals......

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

Question # 28 Group #

1 1

WA #

003.K1.10 Importance Rating 3.0 3.2 Proposed Question:

The following plant conditions exist:

0 Loop flow measurement determined the A Reactor Coolant Pump impeller has degraded such that its Reactor Coolant System (RCS) loop flow has DECREASED by 5% from its original value.

The other three RCS loop flows remain UNCHANGED.

The Reactor is operating at 100% Power.

Based on these conditions, which one of the following would be a result of the decreased flow rate in the A loop?

A. Delta temperature in the A RCS loop at full power will be lower.

B. Demand on the pressurizer variable heaters at 2235 psig will be lower.

C. Steam pressure in the A Steam Generator at full power will be higher.

D. The reactor core margin to Departure from Nucleate Boiling will be lower.

Proposed Answer:

D Explanation of answer: putting out the same MWt with a reduced flowrate means reduced heat transfer capabilities and therefore operation closer to DNB.

Explanation of distractors:

A - Delta T should actually be higher in this situation.

B - Loop A & C RCPs provide PZR spray. However, based on plant design, the A RCP is less effective than the C RCP and provides limited flow. Additionally under steady state1 2235 psig conditions, the sprays are closed and bypasses provide minimal flow to keep the lines warm, so therefore not much impact on current draw from variable heaters.

C - Higher Delta T means Tcold should be lower and therefore steam pressure should be lower.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

L8138i, Core Thermal Limits None Knowledge of the physical connections andor cause effect relationships between the RCPS and the RCS.

55.41.3114 L8138103RO Describe factors that effect peaking and hot channel factors.

~~

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level Tier #

Question # 29 Group #

WA ##

RO SRO 2

2 1

1 004.K5.06 Importance Rating 3.0 3.3 Proposed Question:

Given the following plant conditions:

The plant is operating at 90% power during Middle of Life.

Primary Component Cooling Water (PCCW) flow through the letdown heat exchanger is DECREASED.

Assume no automatic actions occur in the Chemical Volume and Control System (CVCS) and no operator actions are taken.

Based on these conditions, which of the following describes how reactor coolant system (RCS) temperature will be INITIALLY affected?

RCS Temperature A. decreases because the CVCS demineralizers are releasing boron into the letdown flow.

B. increases because the CVCS demineralizers are absorbing boron from the letdown flow.

C. decreases because loop delta temperature is being decreased by hotter CVCS charging flow.

D. increases because loop delta temperature is being increased by hotter CVCS charging flow.

Proposed Answer:

A Explanation of answer: With less PCCW flow through the letdown HXs the RCS water is not cooled as much.

Therefore the inlet temperature of water flowing through the letdown demineralizers is warmer which result in more boron being released into CVCS. This boron once completing the flowpath back into the RCS will result in a drop in RCS temperature which impacts reactivity.

Explanation of distractors:

B - incorrect because exactly the opposite is true. This distractor is a common misconception and describes the effect if PCCW cooling increased and CVCS water temperature drops.

C & D are both incorrect as the cold narrow range RCS temperature RTDs are upstream of charging tap to the loop.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Bank #20895 Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

L8114i, Demineralizers & IXs None Knowledge of the operational implications of the concept of boron worth or IBW (reactivity, pcdppm) 55.41.115 L8 1 14122RO Describe the demineralizer characteristics that can cause a change in boron concentration.

ES-401 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

Question # 30 Group #

1 1

WA #

005.K6.03 Importance Rating 2.5 2.6 Proposed Question:

Given the following plant conditions:

0 The Pressurizer is solid.

The plant is being cooled down in preparation for refueling.

Reactor Coolant System (RCS) temperature is 175°F.

RCS pressure is 305 PSIG.

Charging flow control is in manual.

Residual Heat Removal (RHR) is in the cooldown Mode, with the A Train in service.

The A RHR heat exchanger suddenly develops a 50 gpm tube leak.

Based on these conditions and assuming no operator action is taken, what will be the result of this event?

A. Indicated RHR Pump flow decreases. Pressurizer pressure increases. RCS cooldown rate increases.

B. Indicated RHR Pump flow remains the same. Pressurizer pressure decreases. RCS cooldown rate decreases.

C. PCCW surge tank level will increase, until overflowing to the Primary Auxiliary Building exhaust plenum.

D. PCCW surge tank level will decrease, until the A PCCW pump trips, resulting in a loss of shutdown cooling.

Proposed Answer:

B Explanation of answer: RHR system pressure is higher than PCCW system pressure, causing an RCS leak into PCCW.

Pump flow would remain the same after automatic system adjustment. The system flow control valve is auto set to maintain around 3500 gpm. Downstream of the HX the increased flow would be sensed and the bypass valve would open to accommodate the increased flowate to maintain overall system flowrate constant. Since more flow is now bypassing the RHR HX, the RCS cooldown will not be as effective. With a solid plant and charging in manual a 50 gpm loss from the RCS will result in decreasing RCS pressure Explanation of distractors:

A - incorrect because pump flow would decrease and therefore all parameters are exactly opposite of what would happen.

C - incorrect because although PCCW head tank increases and overflows, the overflow goes to the liquid waste system versus the PAB exhaust system. The tank is vented to the PAB exhaust via an unvalved line where it is directed to the plant vent.

D - incorrect because RHR system pressure is higher than PCCW system pressure which is around 60 to 80 psig, therefore leakage will be into the PCCW system and head tank level will increase.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Higher I O CFR Part 55 Content:

FWR Detailed System Text None Knowledge of the effect of a loss or malfunction on the heat exchanger will have on the RHRS.

55.4 1.7114

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Learning Objective:

L8033107RO Describe the RHR HX outlet tempiflow control scheme.

L8033111RO Describe the flowpath through the FWR system during plant cooldown.

ES-40 1

~~

~~

Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

Question # 3 1 Group #

1 1

WA #

006.K6.03 Importance Rating 2.5 2.6 Proposed Question:

Given the following plant conditions:

The plant has sustained a Large Break Loss of Coolant Accident.

Cold leg Emergency Core Cooling System flow on SI-FI-9 17 is 900 gpm.

Residual Heat Removal flow is 4000 gpm in EACH train.

Containment Building Spray flow is 3000 gpm in EACH train.

Safety Injection Pumps both FAILED to start.

Based on these conditions and assuming Refieling Water Storage Tank was at its Technical Specification MINIMUM level when the accident occurred, approximately how much time will pass before initiation of swap-over to cold leg recirculation?

A. 15 minutes B. 24minutes C. 30 minutes D. 44 minutes Proposed Answer:

B Explanation of answer: TS mimimum volume is 477,000 gallons. Swapover to cold leg recirculation occurs at about 120,000. Approximately 357,000 gallons will be pumped into containment at the following flowrates: SI Flow = 0, Charging Flow = 900 gpm, RHR flow = 8000 gpm, CBS flow = 6000 gpm. Total flow = 14,900 gpm. 357,000/14900 =

24 minutes Technical Reference(s):

Proposed references to be provided to applicants during examination:

TS 3.5.4, CBS & SI Detailed System Text Calculator WA Topic:

Question Source:

Knowledge of the effect of a loss or malfunction of safety injection pumps will have on the ECCS.

Modified Bank #23 134 Original question attached to reference.

Question Cognitive Level:

Higher 10 CFR Part 55 Content:

55.41.8

ES-401 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

Question # 32 Group #

1 1

WA #

007.K3.0 1 Importance Rating 3.3 3.6 Proposed Question:

Given the following plant conditions and sequence of events:

The plant is in Mode 1 at 100% power.

One of the Pressurizer Operated Relief Valves (PORVs) is leaking past its shut seat.

Primary Relief Tank (PRT) cooling does NOT function as designed.

If no operator action is taken, which of the following statements describes an expected outcome of this situation?

A. PRT pressure rises causing rupture disks to rupture to containment atmosphere.

B. PRT pressure rises causing the PRT relief valves to lift to containment atmosphere.

C. PRT level rises causing water to be diverted to containment sump via overflow lines.

D. PRT level rises causing water to be diverted to containment sump via sparging lines.

Proposed Answer:

A Explanation of answer: Without the normal cooling system available, the PRT level would rise and pressure in the tank would continue to increase until rupture disks blowout at 9 1 psig to containment atmosphere.

Explanation of distractors:

B - incorrect because the PRT has rupture disks not relief valves.

C - incorrect because although it is plausible that level will rise, there is no divert to the containment sump.

D - incorrect because again, although it is plausible that level will rise and the sparging lines are located inside the tank and do not interface externally with containment atmosphere.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Modified Bank #24018 Original question attached to reference.

Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

PZR & PRT Detailed System Text None Knowledge of the effect that a loss or malfunction of the PRTS will have on the containment.

55.4 1.3/8 L8022I 1 1 RO Explain how the PRT is protected from overpressurization.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

Question # 33 Group #

1 1

WA #

008.K2.02 Importance Rating 3.0 3.2 Proposed Question:

The following plant conditions exist:

0 The Reactor Operator is in the process of swapping running Primary Component Cooling Water (PCCW) pumps in the A PCCW Loop.

Both A & C PCCW pumps are running when a loss of off-site power occurs.

All system function as designed.

0 Based on these conditions, what will be the status of Train A PCCW pumps at the completion of the emergency power sequencing?

A. Both A and C PCCW pumps tripped.

B. Both A and C PCCW pumps running.

C. Only the A PCCW pump is running and the C PCCW pump is tripped.

D. Only the C PCCW pump is running and the A PCCW pump is tripped.

Proposed Answer:

D Explanation of answer: The C PCCW pump is electrically the preferred pump. Therefore any loss of off-site power and subsequent re-energization of Bus 5 for the A Train will result in the C pump starting. The purpose of this configuration is to prevent the A EDG from overloading during initial starting and sequencing. The A pump gets locked out until RMO is reset by the operator.

Explanation of distractors: Each distractors seeks to cover the other various combinations of pumps starts or lack of starts and are incorrect because of how the interlock is configured as discussed above.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Bank #20230 Original question attached to reference.

Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

CC Detailed System Text None Knowledge of the bus power supplies to the CCW pump, including emergency backup.

55.41.518 L8036106RO Describe the interaction between the EPS and the CC pumps.

ES-40 1

~

~~

Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level Tier #

Question # 34 Group #

WA #

RO SRO 2

2 1

1 008.A4.07 Importance Rating 2.9 2.9 Proposed Question:

Which of the following describes the automatic operation of the Primary Component Cooling Water (PCCW) System in response to PCCW B head tank level decreasing to 40%?

A. Train A and B Waste Processing Building PCCW isolation valves close.

B. Train A and B Waste Processing Building (WPB) Containment isolation valves close.

C. Train B PCCW Radiation Monitor isolation valve and B WPB isolation valves close.

D. Train B PCCW Radiation Monitor isolation valve and B Containment isolation valves close.

Proposed Answer:

C Explanation of answer: According to the OAS page of OS1212.01 and the CC Detailed System Text, the B train PCCW Radiation Monitor and WPB valves will isolate off of a B Train signal at 42%.

Explanation of distractors: The combination of train related signals tends to be a common misconception for this isolation and is the basis for all of the distractors.

A & B - incorrect because the Train A PCCW components are unaffected by a low head tank level in Train B PCCW head tank.

D - incorrect because the containment isolation valves go closed on a Lo-Lo head tank level of 36% vs. the 42% stated in the stem of the question.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

U A

~

~

~

i

~

Question Source:

Bank # 23128 Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

OS12 12.01, PCCW Malhnction OAS Page, CC Detailed System Text None Ability to manually operate and/or monitor control of minimum level in the CCWS surge tank in the control room.

55.41.7 L8036112RO Describe the auto responses of each CC loop to the following signals..... lo tank level.

ES-401

~

Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 1

Question # 35 Group #

1 1

WA #

APE.01 Y017.AK2.07 Importance Rating 2.9 2.9 Proposed Question:

The following plant conditions exist:

0 The plant is operating at 40% power.

Alarms for D Reactor Coolant Pump (RCP) seal leakoff flow are received.

D RCP Total Leakoff Flow indicates 9.0 gpm and increasing.

Based on these conditions, which of the following sequence of actions should be taken by the operating crew according to OS 120 1.O 1, RCP Malhction?

A. Trip the D RCP, take manual control of D SG feedwater control, close the #1 seal leakoff valve after the pump has stopped, and commence a plant shutdown.

B. Feed D SG to 60-70% narrow range, trip D RCP, close the #1 seal leakoff valve after the pump has stopped, and commence a plant shutdown.

C. Trip the reactor and go to E-0, Reactor Trip or Safety Injection. After step 4 of E-0, stop D RCP and close the

  1. 1 seal leakoff valve after the pump has stopped.

D. Trip D RCP, close the #I seal leakoff valve after the pump has stopped, trip the reactor, and perform the immediate actions of E-0, Reactor Trip or Safety Injection.

Proposed Answer:

B Explanation of answer: B is correct because it gives the appropriate series of actions based on a seal leakoff problem when the plant is < P-8 (50%). Isolation of seal return valve after tripping the RCP is one of those actions that is an important interrelationship which is vital to prevent further RCP degradation.

Explanation of distractors:

A - incorrect because it gives the sequence of actions for shutting down an RCP due to high vibrations.

C - incorrect because the plant is < P-8 (50%) setpoint, therefore a reactor trip is not required.

D - incorrect because a reactor trip is not necessary when the plant is < 50% power, where a normal reactor shutdown will be commenced.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Bank # 20453 Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Comment:

Learning Objective:

OS 1201.01, RCP Malfunction None Knowledge of the interrelationship between RCP malfunctions and RCP seals.

55.4 1.51 10 Note that this question was swapped with WA #5 for exam design purposes.

Lll81103RO Summarize the major actions ofOS1201.01.

ES-401 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Question # 36 Level Tier #

Group #

WA #

Importance Rating RO SRO 2

2 1

1 010.K6.03 3.2 3.6 Proposed Question:

Given the following plant conditions:

0 The plant is operating at 100% steady state power, with all systems in AUTOMATIC.

The output of the Pressurizer Master Pressure Controller fails to 40%.

Based on these conditions, what effect will this have on Pressurizer heaters and spray valves?

A. Backup heaters energize, and spray valves open.

B. Backup heaters remain off, and spray valves open.

C. Backup heaters energize, and spray valves remain closed.

D. Backup heaters remain off, and spray valves remain closed.

Proposed Answer:

C Explanation of answer: The master pressure controller output varies from 0 to loo%, with 40% demand acting as if PZR pressure is low. A low failure of the master pressure controller will turn on all PZR heaters in auto and inhibit spray valves in auto.

Explanation of distractors: All combinations of heaters and sprays in the distractors are incorrect.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

KIA Topic:

Question Source:

New Question Cognitive Level:

Higher 10 CFR Part 55 Content:

55.41.7 Learning Objective:

L8027106RO Describe the auto control hnctions of the PZR pressure and level control system.

L8027114RO Explain the auto response of the plant to a high or low failure of the PZR press or level instrument.

PPLC Detailed System Text None Knowledge of the effect of a loss or malhnction of the PZR sprays and heaters will have on the PZR PCS.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 1

WA #

APE.027.AK1.02 Importance Rating 2.8 3.1 Question # 37 Group #

1 1

Proposed Question:

The following plant conditions exist:

0 0

The unit is at 100% power, steady state conditions.

A malfunction of the Master Pressurizer Pressure Controller has caused Reactor Coolant system pressure to increase 80 psig from its normal setpoint.

Given these conditions, which one of the following items will be MOST impacted by this malfinction?

A. Volume Control Tank Level.

B. Pressurizer Relief Tank Pressure.

C. Pressurizer Vapor Space Temperature.

D. Overpower Delta Temperature Trip Setpoints.

Proposed Answer:

C Explanation of answer: Since the PZR operates in a saturated condition, a pressure change will result in a change in saturation temperature. Saturation temperature of 2235 psig (NOP) is 652.7 F. An 80# decrease would drop this value to about 648 F. An 80 # increase would raise value to 658 F.

Explanation of distractors:

A - Incorrect because a small change of 80# would have only a minimal impact on charging and letdown flowrate, plus auto level control maintaining PZR level constant means VCT level will be constant.

B - Incorrect because an increase of 80 # is not high enough to lift the PORV so therefore there is no effect on PRT D - Incorrect because OPDT doesnt use pressure input to calculate the trip setpoint (OTDT does however-common misconception)

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

PZR Detailed System Text Steam Tables Knowledge of the operational implications of the concept of expansion of liquids as temperature increases as applied to PZR Pressure Control Malfinctions.

55.41.5114 L8027114RO Explain the auto response of the plant to a high or low failure of the PZR press or level instrument.

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

Question # 38 Group #

1 1

Proposed Question:

Importance Rating 2.9 3.3 WA #

013.K5.02 Which of the following describes the logic required to initiate the ESF actuations generated by the following signals?

Containment HI-1 Containment HI-2 Containment HI-3 m

(MSLI)

(CBS/P/CVI)

A.

2 of3 2 of3 2 o f 3 D.

2 o f 3 2 of3 2 of4 Proposed Answer:

D Explanation of answer: RP system text, lesson plan, and functional diagram all describe the actuation coincidence for ESF actuations based upon containment pressure. Only D contains the correct combination of system logic.

Explanation of Distractor: Note distractors are combinations of the plausible answers.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA RP Detailed System Text, Functional Diagram 1 -NHY-50904 None Knowledge of the operational implications of the safety system logic and reliability as applied to ESFAS.

Topic:

Question Source:

Bank Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

55.41.7 L8057108RO For each of the following ESFAS signals, describe how the signal is generated, reset. and blocked..........

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

Question # 39 Group #

1 1

WA #

013.A4.03 Importance Rating 4.5 4.7 Proposed Question:

The following plant conditions exist:

The plant has sustained a Steam Line Break.

The reactor has been manually tripped due to INCREASING power range indication.

Subsequent to the plant trip, the following plant parameters indicate as follows:

A S/G Pressure is 800 psig and STABLE B S/G Pressure is 760 psig and DECREASING C S/G Pressure is 800 psig and STABLE D S/G Pressure is 800 psig and STABLE RCS Pressure is 1880 psig and DECREASING Containment Pressure is 6.1 psig and INCREASING Based on these plant conditions and assuming NO additional actions have been taken and all safeguards systems function as designed, which of the following describes the Engineering Safeguard Features Actuations that should have occurred, in addition to Safety Injection?

A. Containment Isolation Phase A ONLY.

B. Containment Isolation Phase A, and Main Steam Isolation ONLY.

C. Containment Isolation Phase A, Main Steam Isolation, and Containment Spray ONLY.

D. Containment Isolation Phase A, Main Steam Isolation, Containment Spray, and Containment Isolation Phase B.

Proposed Answer:

B Explanation of answer: A SLB has occurred in Containment. Containment pressure has increased sufficiently to satisfy the logic for Safety Injection and MSI at 4.3 psig. The fact that the A,C, & D S/G pressures are stable indicates MSI was successful in isolating the SLB to B S/G inside containment. Phase A isolation is generated in conjunction with an SI signal Explanation of Distractors:

A - incorrect because MSI also occurred based on containment pressure > 4.3 psig.

C & D - incorrect because containment pressure did not satisfy the required logic for CBS to occur. The same signal which generates CBS also generates Phase B isolation which would also not occur.

Technical Reference( s):

Proposed references to be provided to applicants during examination:

KIA Topic:

Question Source:

Bank #23200 Question Cognitive Level:

Higher 10 CFR Part 55 Content:

55.41.7 IS & RP Detailed System Text None Ability to manually operate andor monitor ESFAS initiation in the control room.

Form ES-40 1-5 ES-401 Seabrook Written Examination Question Worksheet Comments:

Learning Objective:

Minor editorial modifications to bank question.

L8057108RO For each of the following ESFAS signals, describe how the signal is generated, reset, and blocked..........

L8057110RO For each of the following ESFAS signals list the actions auto initiated by the signal.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Question ## 40 Level Tier #

Group ##

WA #

Importance Rating RO SRO 2

2 1

1 022.K4.03 3.6 4.0 Proposed Question:

Given the following plant conditions:

CGC-VI4 and CGC-V28, Containment Structure Purge Isolation Valves are open for surveillance testing.

All systems are operating as designed.

Based on these conditions, which of the following choices correctly identifies the system response to an automatically generated Train A T signal?

A. CGC-V14 and CGC-V28 BOTH CLOSE.

B. CGC-V14 and CGC-V28 BOTH remain OPEN.

C. CGC-VI4 remains OPEN and CGC-V28 CLOSES.

D. CGC-V14 CLOSES and CGC-V28 remains OPEN.

Proposed Answer:

D Explanation of answer: It is important that the operator is aware of the potential for releasing airborne activity from containment to the outside environment and should take appropriate actions if the situation warrants. In the case of containment purge, if a Train A T signal is generated only the train A valve (CGC-V14) will close. CGC-V28 will remain open.

Explanation of distractors:

B,C & A are incorrect because their combinations do not warrant a correct answer.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA

~

~

~

i

~

automatic containment isolation.

Question Source:

Modified Bank #24422 Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

CHV Detailed System Text None Knowledge of CCS design feature(s) andor interlock(s), which provide for 55.4 1.7 L8038112RO Describe the Response of the CGC components to a T signal.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 1

Question # 4 1 Group #

1 1

WA #

APE.054.AA1.04 Importance Rating 4.4 4.5 Proposed Question:

The following plant conditions exist:

A Total Loss of Feedwater has occurred.

0 The crew is performing FR-H.1, Response to Loss of Secondary Heat Sink and are currently at step 5, Try to Establish SUFP flow to at least one Steam Generator (S/G).

0 Containment conditions are normal.

0 Reactor Coolant Pumps are tripped.

Pressurizer Pressure is 2385 psig.

Which of the conditions below support the initiation of bleed and feed cooling using this criteria?

A. SG wide range levels are all 50%

RCS Thot is 570 F and slowly rising RCS Tcold is 560 F and relatively constant B. SG wide range levels are all 40%

RCS Thot is 570 F and relatively constant RCS Tcold is 560 F and relatively constant C. Two SG wide range levels are 50%, the other two are 5%

RCS Thot is 570 F and relatively constant RCS Tcold is 560 F and relatively constant D. Two SG wide range levels are 7%, the other two are 5%

RCS Thot is 570 F and slowly rising RCS Tcold is 570 F and slowly rising Proposed Answer:

D Explanation of answer: With the onset of natural circulation (due to securing RCPs) RCS pressure continues to rise and may reach the PORV setpoint. The key to determining if RCS pressure rise is due to loss of heat sink as opposed to natural circulation is loop DT. Loop DT is expected to be large for natural circulation and small for loss of heat sink since there is no heat transfer. Additionally, there is insufficient inventory in the S/Gs (3 < 26% WR) which warrants Bleed and Feed conditions. (common misconception)

Explanation of distractors:

A - Incorrect because it does not meet S/G water level criteria & more reflects natural circulation conditions.

B - Incorrect because adverse containment is not applicable and a larger DT more reflects natural circulation.

C - Incorrect because a third S/G would need to be below 26% and a larger DT more reflects natural circulation Technical Reference(s):

Proposed references to be provided to applicants during examination:

K/A Topic:

FR-H. 1 Operator Action Summary, FR-H. 1 Background Document None Ability to operate and/or monitor HPI, under total feedwater loss conditions as applied to Loss of Main Feedwater.

\\

Question Source:

Bank #20656

ES-401 Seabrook Written Examination Question Worksheet Form ES-401-5 Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

55.4 1.10/14 L1211103RO State the basis for steps, notes, and cautions in FR-H.l

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

Question # 42 Group #

1 1

WA #

026.A1.01 Proposed Question:

Importance Rating 3.9 4.2 A Large Break Loss of Coolant Accident is occurring. The following specific plant conditions exist:

0 0

Highest Containment Pressure = 35 psig.

RWST Level = 480,000 gallons and decreasing.

A Containment Spray Pump (CBS-P-9A) Suction Pressure = 60 psig and decreasing.

A Containment Spray Pump (CBS-P-9A) Discharge Pressure = 120 psig and decreasing.

B Containment Spray Pump (CBS-P-9B) Suction Pressure = 60 psig and decreasing.

B Containment Spray Pump (CBS-P-9B) Discharge Pressure = 265 psig and decreasing.

Based on the above parameters, which one of the following choices is correct?

A. CBS-P-9A is below its design flow; containment pressure exceeded design.

B. CBS-P-9A is pumping normally; containment pressure did NOT exceed design.

C. CBS-P-9B is below its design flow; containment pressure exceeded design.

D. CBS-P-9B is pumping normally; containment pressure did NOT exceed design.

Proposed Answer:

D Explanation of answer: Based on detailed system text and LP information, the design pressure of the CBS pump is 350 psig. As the CBS pumps do not have indicators, it is important (and is the source of common misconceptions) that the candidates be able to discern proper CBS operating characteristics. A computer alarm comes in at 300 psig to warn the operator. A low discharge pressure alarm of 62 psig is also available. With the RWST full the static head of that tank should be about 60 psig which is felt on the suction of the CBS pump. Design containment pressure is 52 psig.

Explanation of distractors:

A & C - are incorrect based on containment pressure not exceeding design alone.

B - design pressure not exceeded is correct, however, the combination of discharge pressure choices makes this choice incorrect.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Modified Bank #22830 Original question attached to reference.

Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

CBS Detailed System Text, LP8035 CBS System None Ability to predict and/or monitor changes in parameters associated with operating the CSS controls including Containment Pressure.

55.41.718 L8035110RO State the design flowrate and approximate head for the CBS pumps.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

Question # 43 Group #

1 1

WA #

039.K5.08 Importance Rating 3.6 3.6 Proposed Question:

Given the following plant conditions:

0 The plant is operating at 12% power, Middle of Life (MOL).

Control Bank D rods are at 150 steps withdrawn in MANUAL.

Main turbine is steady at 800 RPM during turbine startup.

Main Steam Dumps are set for 1050 psig in the STEAM PRESSURE Mode of control.

Given these conditions, if the main steam dump AUTO setpoint is lowered to 1040 psig, what effect will this have on Tavg and reactor power assuming NO other operator action?

A. Tavg will RISE, Reactor Power will RISE.

B. Tavg will LOWER, Reactor Power will RISE.

C. Tavg will RISE, Reactor Power will LOWER.

D. Tavg will LOWER, Reactor Power will LOWER.

B Proposed Answer:

Explanation of answer: When the steam dump setpoint is adjusted downward, the control system will automatically attempt to control steam header pressure at the new setpoint by opening the steam dump valves further to reduce pressure. Tc will lower to the new saturation temp for the new lower steam pressure. Tave will lower, and positive reactivity added will cause reactor power to rise. Reactor power follows steam demand.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

Reactor Theory Fundamentals, SD Detailed System Text None Knowledge of the operational implications of the effect of steam removal on reactivity as applied to MRSS.

55.4 1.16 L8047106RO Describe the two Modes of operation of the SD system.

L8 12812 1RO Explain the relationship between reactor power and steam flow.

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

Question # 44 Group #

1 1

WA #

059.A3.02 Importance Rating 3.2 3.3 Proposed Question:

Which one of the following describes the fimctional relationship (with respect to controlling steam generator (S/G) levels) between the Main Feedwater Pumps (MFPs) and the Main Feedwater Regulating Valves (MFRVs) when the unit is ramping from 50% to 100% power?

A. The MFPs maintain a variable differential pressure across the MFRVs, while the MFRVs throttle to maintain a constant S/G water level.

B. The MFPs maintain a constant differential pressure across the MFRVs, while the MFRVs throttle to maintain a variable S/G water level.

C. The MFPs maintain a variable differential pressure across the MFRVs, while the MFRVs throttle to maintain a variable S/G water level.

D. The MFPs maintain a constant differential pressure across the MFRVs, while the MFRVs throttle to maintain a constant S/G water level.

Proposed Answer:

A Explanation of answer: The design of the SGWLC system is to maintain a constant level in the S/Gs at all power levels.

The MFW control system however varies the programming to maintain an optimum DP across the MFRVs.

Explanation of distractors:

B,C, & D - All incorrect because the combination of answers makes them so.

Technical Reference(s):

LP8046, SGWLC Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Bank #22280 Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

None Ability to monitor automatic operation of the MFW, including programmed levels of the S/G.

55.41.7 L8046105RO Describe how an auto feed pump control signal is generated.

L8046106RO Explain how each of the following process parameters are used in SGWLC........

L8046103RO Describe how an auto MFRV control signal is generated.

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

Question # 45 Group #

1 1

WA #

061.K4.14 Importance Rating 3.5 3.7 Proposed Question:

Given the following plant conditions and sequence of events:

0 The reactor has tripped due to a Main Steam Line Break inside containment from the C Steam Generator (S/G).

Emergency Feedwater (EFW) flow to the C S/G is 500 gpm and INCREASING.

EFW flow to the A, B, & D S/Gs is 220 gpm each and STABLE.

All systems are automatic and functioning as designed.

Based on these conditions, which of the following describes the expected response regarding EFW flow to the C S/G?

A. EFW control valves will auto close when flow reaches 525 gpm.

B. EFW flow control valves will modulate to maintain flow at setpoint.

C. EFW flow will be limited to 525 gpm by the venturi in the EFW piping.

D. EFW flow will be limited to 750 gpm by the differential pressure across the flow orifice.

Proposed Answer:

A Explanation of answer: By design downstream of each EFW headers flow venturi there is a flow sensing orifice. DP across this orifice is sensed by two train specific transmitters. When 525 gpm is sensed a signal is sent to its associated MOV flow control valve to isolate feedwater to the effected faulted S/G. The isolation should only occur to the first S/G without operator action. This is to prevent cascading isolation of EFW to all S/Gs. The function of the flow venturi and orifice is a common misconception which is used in the design of the distractors.

Explanation of distractors:

B - incorrect because these particular valves have no modulation feature such as that of the MFRVs. (plausible misconception)

C - incorrect because the venture limits flow to a faulted header to a maximum of 750 gpm if both FCV fail to close.

D - incorrect because the orifice function is to sense a flow of 525 to close the FCV MOV when this high flow is sensed.

Technical Reference( s):

Proposed references to be provided to applicants during examination:

WA L8045, EFW SYSTEM EFW Detailed System Text None Knowledge of AFW design feature(s) and/or interlock(s) which provide for AFW automatic isolation.

Topic:

Question History:

Modified Bank # 23143 Original question attached to reference.

Question Cognitive Level:

Higher 10 CFR Part 55 Content:

55.41.7 Learning Objective:

L8045107RO State the functions of the flow venture and the flow orifice in each S/G EFW supply line.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Question # 46 Proposed Question:

Tier #

2 2

Group #

1 1

WA #

061.GEN 2.1.32 Importance Rating 3.4 3.8 Given the following plant conditions:

A reactor trip from 100% power has occurred.

The Balance of Plant Operator is throttling Emergency Feedwater (EFW) flow to all Steam Generators (SIG).

Based on these conditions, whch of the following describes the system design limits used to minimize the potential for Loss of Heat Sink when throttling EFW?

A. Throttle or isolate flow to each S/G using Train A EFW flow control valve.

B. Throttle or isolate flow to each SIG using Train B EFW flow control valve.

C. Throttle or isolate flow to TWO SlGs using Train A EFW flow control valve, and to TWO SIGs using the Train B EFW flow control valve.

D. Throttle EFW flow to each SIG by using ONE EFW flow control valve. Isolate EFW flow to each S/G with the OPPOSITE train EFW flow control valve.

Proposed Answer:

C Explanation of answer: According to EFW system text and the USFAR, it is a precaution to use opposite train EFW control valves so that a loss of power will not interrupt flow to all SIGs at one time. This would result in a loss of potential flow control to only two S/Gs vs. all four.

Explanation of distractors: All are incorrect because the combination of responses result in a loss of flow to all S/Gs with a loss of all AC power.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

EFW Detailed System Text, USFAR Section 6.8 None Ability to explain and apply all system limits and precautions.

Bank I 1998 Seabrook NRC RO #92 55.4 1.8/ 1 0 L8045106RO Describe the train separation requirements for the EFW flow control valves and the basis for these requirements.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO

\\.

Tier #

2 2

Question # 47 Group #

1 1

WA #

062.A2.09 Importance Rating 2.7 3.0 Proposed Question:

Given the following plant conditions:

0 0

The Unit is at 100% steady state power.

Multiple VAS alarms are received related to the Unit Auxillary Transformer (UAT).

The operating crew concludes that an Overcurrent condition has caused the 86UB lockout device to trip for the A Train UAT(s).

Based on these conditions, which of the following correctly predicts the outcome and procedure that the crew should enter?

A. Buses 1, 3, & 5 will have power, the crew should enter E-0, Reactor Trip or Safety Injection B. Buses 1, 3, & 5 will have NO power, the crew should enter E-0, Reactor Trip or Safety Injection.

C. Buses 1,3, & 5 will have power, the crew should respond using VAS and Abnormal procedures ONLY.

D. Buses 1,3, & 5 will have NO power, the crew should respond using VAS and Abnormal procedures ONLY Proposed Answer:

Explanation of answer: The 86UB device senses overcurrent (unique to UATs only). Once actuated, the turbine will trip, the main generator output breaker will open, the exciter breaker will open, the UAT associated busses supply breakers will open (in this case 13.8 kV for Bus 1,4160 kV for Bus 3 & 5). Additionally 345 kV PCBs 1 1 and 163 will open and the affected UAT cooing fans will trip. Since the reactor is above P-9, the. turbine trip will cause the reactor to trip. Entry into E-0 in this case is required. The 86UB device once actuated wil@&ent transfer from the UAT to the RAT backup supply of power, so therefore Bus 1, 3, & 5 will remain knergized.

Explanation of distractors:

Bp(- incorrect because transfer to RAT power supply will &occur. E-0 is correct procedural reference.

C - incorrect because again the busses will have no power and additionally, although it is plausible the crew could use VAS procedures and eventually AOPs, E-0 would be the overriding procedure once the reactor trips.

D - incorrect because although it is plausible that the busses will have no power, the procedural references are incorrect for the reasons stated above.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

309742 sieet 8 4~a+eL+,ve

~ b 2, -

-4c OAT w - 2 ~

ELL^> K e b - Y y,

.v,deo A h -

13.8 kV Detailed GternText, L8012I 13.8 kV Lesson

,-w i-t-D d S Respa-% 4-bet-2A M 5yS 2 TglPr None a

Ability to predict the impacts of the consequences of exceeding current limitations on the AC distribution system and based on these predictions, use procedures to correct, control, or mitigate the consequences of these malhnctions or operations.

55.41.51718 L8012108RO Describe how an electrical fault within a UATIRAT will effect the station electrical distribution system alignment.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO L

Tier #

2 2

Question # 48 Group #

1 1

WA #

062.GEN2.4.1 Importance Rating 4.3 4.6 Proposed Question:

Given the following plant conditions and sequence of events:

0 0

The plant is operating at 100% Power.

A Emergency Diesel Generator (EDG) is Danger Tagged out of service for oil pump replacement.

A Loss of Offsite Power occurs.

Based on these conditions, which of the following choices is the correct course of action for the operating crew?

A.

B.

C.

D.

Verify reactor and turbine trip in accordance with ECA-0.0, Loss of All AC Power.

Verify reactor trip, turbine trip, and restoration of power to Bus 6 in accordance with E-0, Reactor Trip or Safety Injection.

Verify reactor trip and Bus 6 restoration of emergency power in accordance with 081246.01, Loss of Offsite Power - Plant Shutdown.

Verify turbine trip and restoration of power to Bus 6 in accordance with OS1246.02, Loss of a Vital Unit Substation or MCC.

Proposed Answer:

B Explanation of answer: Based on given set of plant conditions, a loss of offsite power will result in a reactor trip due to loss of RCS flow. Therefore E-0 immediate actions must be carried out which include verifying reactor & turbine trip &

ensuring power to AC Emergency busses making choice B correct. The operator must distinguish between a loss of offsite power and complete loss of AC power and recognize what entry conditions are required. These are immediate action steps and therefore are required to be performed from memory.

Explanation of distractors:

A - incorrect because a complete loss of AC power did not occur, so therefore it would not be correct to direct entry into ECA-0.0. Direct entry into ECA-0.0 is allowed if a complete loss of onsite and offsite power occurs. In the case of this question, the stem does not state the status of Bus 6 EDG which is assumed to start and load onto bus 6. The operator cannot assume this did or did not happen, it must be checked before direct entering ECA-0.0.

D - incorrect although plausible because the turbine does trip. EOPs take precedence over AOPs when the reactor trips.

C - incorrect although plausible because it contains all of the aspects of the correct answer with the improper procedural reference because EOPs take precedence over AOPs and the reactorhrbine trip is not verified in the AOP.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

E-0 immediate actions, ECA-0.0 immediate actions None Knowledge of EOP entry conditions and immediate action steps as applied to AC Distribution system.

55.41.10 Lf 202IOIRO State symptoms and entry conditions for E-0.

Seabrook Written Examination Question Worksheet Form ES-40 1-5 ES-40 1 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

Question # 49 Group #

1 1

WA #

063.K3.02 Importance Rating 3.5 3.7 Proposed Question:

Which of the following hnctions of Diesel Generator 1A is lost if 125 VDC bus 1 1A is de-energized?

A. Engine operating parameter indication.

B. All Engine protective tripping capability.

C. Control of DG-1A supply and exhaust fans.

D. Normal and emergency engine start capability.

Proposed Answer:

D Explanation of answer: Loss of Vital Bus 11A results in Loss of DG-1A start capability. The test start and emergency start relays cannot be energized with Loss of DC control power.

Explanation of distractors: The controVprotection features for a diesel provided from 125vdc is a source of common misconceptions and helps frame the structure of the distractors.

A - incorrect because the EDG will still trip on mechanical overspeed.

B - incorrect because engine operating parameters such as speed ad coolant flows and temperatures can be read on DG instrument panel on the end of the engine.

C - incorrect because control power for the supply & exhaust fans is from MCC-52 1 versus Bus 1 1A Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Knowledge of the effect that a loss or malfunction of the DC Electrical Distribution System will have on components using DC Control power.

Question Source:

Bank Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

OS1248.01 Loss of A Vital DC BusDAH Print 310928 None 55.41.7 L1189115RO Describe the effects of losing vital DC power on the following equipment---EDGs.

L8020123RO Describe the importance of 125VDC power for the proper auto operation of the EDG and EPS.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

Question # 50 Group #

1 1

WA #

064. A2.04 Importance Rating 2.7 3.O Proposed Question:

Given the following plant conditions and sequence of events:

The plant is in Mode 5.

A Loss of off-site power occurs.

Emergency Diesel Generator(s) load to approximately 1300 KW.

Once offsite power is restored, which of the following best describes how an Emergency Diesel Generator (EDG) will be unloaded?

Once paralleled with an off-site source, A.

B.

C.

D.

lower load to 1200 to 1225 KW and open the EDG output breaker, using the guidance of ECA-0.0, Loss of All AC Power.

lower load to 1200 to 1225 KW and open the EDG output breaker, using the guidance of OS 1246.0 1, Loss of Offsite Power Plant Shutdown.

lower KVARS to less than 200 lagging and lower load to 75 to 125 KW, and open the EDG output breaker using the guidance of ECA-0.0, Loss of All AC Power.

lower KVARS to less than 200 lagging and lower load to 75 to 125 KW, and open the EDG output breaker using the guidance of 081246.01, Loss of Offsite Power Plant Shutdown.

Proposed Answer:

D Explanation of answer: Since the plant is in Mode 5, 081246.01 is the applicable procedure during these plant conditions. ECA-0.0 is not applicable in Mode 5 or 6. Attachment C of this procedure states that prior to opening the output breaker the EDG should be unloaded to ~ 2 0 0 KVARS and load to 75 to 125 KW.

Explanation of distractors:

A - incorrect because both the methodology and procedure reference are incorrect. Opening the EDG output breaker without unloading could cause equipment damage.

B - incorrect because of methodology, procedural reference is correct.

C - incorrect because although procedural reference is correct the methodology is incorrect.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

081246.01, Loss of Offsite Power Plant Shutdown, Attachment C None Ability to predict the impacts of unloading the EDG prior to securing and based on these predictions, use procedures to correct, control, or mitigate the consequences of this malhnctiodoperation.

55.41.10 L1192109RO Recognize symptoms or entry conditions for 081246.01 L1192110RO Summarize the major actions of OS1246.01.

ES-401 Seabrook Written Examination Question Worksheet FOITII ES-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

Question # 5 1 Group #

1 1

WA #

073.A1.01 Importance Rating 3.2 3.5 Proposed Question:

Which of the following describes the automatic response of the Waste Gas System to a high process radiation reading at the Waste Gas Compressors?

A. Waste Gas Inlet radiation monitor (RM-6503) alarms & WG-FV-1602, Waste Gas Compressor Discharge Flow Control Valve, modulates.

B. Waste Gas Inlet radiation monitor (RM-6503) alarms & WG-FV-1602, Waste Gas Compressor Discharge Flow Control Valve, closes.

C. Waste Gas Outlet radiation monitor (RM-6504) alarms & WG-FV-1602, Waste Gas Compressor Discharge Flow Control Valve, modulates.

D. Waste Gas Outlet radiation monitor (RM-6504) alarms & WG-FV-1602, Waste Gas Compressor Discharge Flow Control Valve, closes.

Proposed Answer:

D Explanation of answer: Attachment A of 081252.01 provides a listing of all Seabrook Process and Effluent Radiation Monitors as well as automatic functions. For a Waste Gas alarm, RM-6504-1 senses outlet waste gas compressor radiation and functions to close WG-FV-1602.

Explanation of distractors:

A - incorrect because inlet radiation vs outlet and the isolation valve closes vs. modulates.

B - incorrect because inlet radiation vs outlet, valve closing is plausible.

C-incorrect because valve closes vs modulatess, outlet radiation is plausible.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

K/A Topic:

Question Source:

Bank #19439 Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

081252.01, Process or Effluent High Radiation None Ability to predict andor monitor changes in parameters associated with operating the PRM system controls including radiation levels.

55.4 1.12/ 13 L8064107RO Describe the auto actions associated with the Waste Gas radiation monitors upon a high radiation signal.

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO L.

Tier #

2 2

Question # 52 Group #

1 1

WA #

073.A4.0 1 Importance Rating 3.9 3.9 Proposed Question:

The following plant conditions exist:

A discharge of the Waste Test Tank (WTT) A is in progress.

A high eMuent alarm condition occurs on the radiation monitor associated with WTT A effluent (RM6509-1).

Based on these conditions, which of the following describes the required action and associated time requirement in accordance with CP 4.1, Effluent Surveillance Program?

A. Resample immediately.

B. Resample within 15 minutes.

C. Isolate the release immediately.

D. Isolate the release within 15 minutes.

Proposed Answer:

C Explanation of answer: CP-4.1 states that when a monitor indicates a high level andor trip, the release shall be terminated immediately. Since this is an immediate action, it is prudent that an operator should know this information closed book without reference to protect the health and safety of the public.

Explanation of distractors: all other combinations of potential answers are incorrect.

Technical Reference(s):

CP-4.1 Section 4.2.

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Bank #26 160 Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

None Ability to manually operate andor monitor effluent release in the control room.

55.4 1.12/13 L 15 171 1 OR0 Describe the immediate action which must be performed should a process rad monitor identify an alarm condition while a release is in progress.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level Tier #

Question # 53 Group #

WA #

RO SRO 2

2 1

1 076.K2.01 Importance Rating 2.7 2.7 Proposed Question:

Given the following plant conditions and sequence of events:

0 0

0 0

0 Service Water Pumps P-4 1A and P-4 1B are running.

A loss of 345 kV Switchyard has occurred.

4 160 VAC Bus 5 has been de-energized due to a Bus differential relay actuation.

Control room operators have initiated a MANUAL safety injection.

All safety systems are automatically functioning as designed.

Based on these conditions and assuming no operator action, which of the following choices identifies the Service Water Pump(s) that will be running TWO minutes after the Safety Injection initiated?

A. P-41B ONLY.

B. P-41D ONLY.

C. P-41C and D.

D. P-41B and D.

Proposed Answer:

A Explanation of answer: With Bus 5 de-energized, the A & C SW pumps will not have power, and therefore will not start. With a loss of off-site power, both EDGs will start on under voltage, however, only the Bus 6 EDG will repower its associated bus since Bus 5 has an electrical fault which will prevent its re-energization. Since only P-41B was running, it will restart at the appropriate time in the reloading sequence (HR8) well before the 2 minute point.

Explanation of distractors: In addition the interface of the EPS with the preferred SW pump operation is a common misconception and frames the structure of the distractors.

B-incorrect because both pumps were not running prior to loss of power and SI. This is a plausible distractor because if both were running P-41D would be the preferred pump.

C - incorrect because P-41C is powered from Bus 5 which has no power.

D - incorrect because only one of these pumps will reload automatically unto the bus without operator action. Both pumps are powered from Bus 6.

Technical Reference(s):

SW & EDG Detailed System Text Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Higher 10 CFR Part 55 Content:

55.4 1.7 Learning Objective:

L8037106RO Describe the interlocks and auto stadstop or opedclosed features associated with the following components---SW pumps.

None Knowledge of the bus power supplies to Service Water.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

Question # 54 Group #

1 1

WA #

078.K4.02 Importance Rating 3.2 3.5 Proposed Question:

Which of the following describes the operation of the Service Air isolation valves, SA-V92 and SA-V93, during an Instrument Air leak?

A. AUTOMATICALLY CLOSE at 90 psig decreasing, AUTOMATICALLY OPEN above 93 psig INCREASING.

B. AUTOMATICALLY CLOSE at 80 psig decreasing, AUTOMATICALLY OPEN above 83 psig INCREASING.

C. AUTOMATICALLY CLOSE at 90 psig decreasing, resets to allow MANUAL OPENING above 93 psig INCREASING.

D. AUTOMATICALLY CLOSE at 80 psig decreasing, resets to allow MANUAL OPENING above 83 psig INCREASING.

Proposed Answer:

C Explanation of answer: LP 8023i states that SA-V-92 close < 90 psig and reset > 93 psig. The reset allows manual opening via control switch as specified in ON1242.01.

Explanation of distractors:

A - incorrect because SA-V-92 & 93 do not reopen automatically when pressure is regained.

B & D - incorrect because the listed set-points are inaccurate. Additionally, B is incorrect because valves do not automatically reopen.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

ON1242.01, Loss of IA, L8023i Compressed Air Lesson None Knowledge of the IAS design feature(s) and/or interlock(s) which provide for cross over to other air systems.

Bank/ 1998 NRC Exam RO# 34 55.41.4 L8023116RO Describe the impact on plant operation if both IA loops within either compressed air system should become depressurized.

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO 4

Tier #

2 2

Question # 55 Group #

1 1

WA #

103.K3.02 Importance Rating 3.8 4.2 Proposed Question:

Given that each of the following conditions concerning the Containment System have existed for greater than four hours, which one does NOT meet the associated Technical Specification action statement?

A. In Mode 1, an automatic containment isolation valve is OPEN and fully OPERABLE.

B. In Mode 1, a manual containment isolation valve is OPEN and under admmistrative control.

C. In Mode 2, an automatic containment isolation is SHUT and declared INOPERABLE.

D. In Mode 2, a manual containment isolation valve is SHUT and under administrative control.

Proposed Answer:

C Explanation of answer: Per TS 3.6.3, in Modes 1-4, each containment isolation valve shall be OPERABLE.

Explanation of distractors:

A - incorrect because automatic containment isolation valves may be opened as long as they are capable of carrying out their automatic protective functions. Since the valve is operable it can perform its safety function.

B - incorrect because there is an exception at the bottom of the page which allows a containment isolation valve to be open under administrative control.

D - incorrect because it meets no criteria for any LCO. The valve is shut, mentions nothing about operability and is under administrative control.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

TS 3.6.1.1 & 3.6.3 None Knowledge of the effect that a loss or malfunction of the containment system will have on Loss of containment.

55.41.9 L8038105aRO State from memory an apply the LCO and actions for the following TSs: 3.6.1.1

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

Question # 56 Group #

2 2

WA #

002.K3.03 Importance Rating 4.2 4.6 Proposed Question:

Consider each of the following situations separately during Mode 1 operations with NO operator action.

Over the next 20 minutes, which of the following situations would be expected to raise containment humidity?

A. A fourth Containment Air Handling Fan is started.

B. A #1 seal failure is experienced on a Reactor Coolant Pump.

C. Letdown Isolation Valve (CS-V-145) inadvertently shuts due to loss of air.

D. RCS Loop #3 Flow Transmitter (RC-FT-434) low pressure side develops a leak.

Proposed Answer:

D Explanation of answer: This was an actual event at Seabrook following last refueling outage (OR09). A high temperature coolant leak from a pressurized system when exposed to atmospheric pressure will flash to steam and rapidly increase humidity levels in the containment.

Explanation of distractors:

A - is incorrect because more coolingheat transfer will actually reduce humidity levels.

B - is incorrect because #1 seal failure could result in high leakoff, however the increased flow will still go to the VCT via seal return line. A portion of the high leakoff might go to #2 seal whch is hard piped to the RCDT.

C - is incorrect because letdown flow would isolate which would increase PZR level until the high level reactor trip occurred at 92%. However it would be a long term of no operator action until PORVs lifted and filled the PRT which would eventually rupture and raise containment humidity levels.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Higher 10 CFR Part 55 Content:

55.41.5 Learning Objective:

L802 1107RO Describe how flow is measure in the RCS loop.

L802 1127RO Describe the principles of operation of the three seals in the RCP seal package.

L1180104RO Entry conditions for an RCS leak.

L802 li RCS Lesson None Knowledge of the effect that a loss or malfunction of the RCS will have on the containment.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Question # 57 Level RO SRO Tier #

2 2

Group #

2 2

KIA #

014.A2.02 Importance Rating 3.1 3.6 Proposed Question:

Given the following plant conditions and sequence of events:

The plant is at 100% power.

Power is lost to MCC-53 1.

Soon afterwards, the Reactor Protection system generates an automatic reactor trip signal and all plant systems respond normally.

The US directs entry into E-0, Reactor Trip or Safety Injection.

Based on these conditions, which of the following predictions and resultant actions should be performed by the operating crew?

A. Rod bottom lights are lit, decreasing reactor power is verified by the reactor operator and the crew should proceed on to verify turbine trip.

B. Rod bottom lights are NOT lit, the crew should exit the procedure and go to FR-S. 1, Response to Nuclear Power GeneratiodATWS, Step 1.

C. Rod bottom lights are NOT lit, but reactor trip is verified by reactor trip breaker open indication and neutron flux levels decreasing. The crew should proceed on to verify turbine trip.

D. Rod bottom lights are lit, the primary side operator should perform a manual trip using the manual trip switches.

Reactor trip is then verified so the crew should proceed on to verify turbine trip.

Proposed Answer:

C Explanation of answer: DRPI indication only is lost. Without MCC-53 1, rod bottom lights cannot be verified. Positive trip indication is provided by reactor trip breaker position and neutron flux levels. The crew should proceed on to verify turbine trip in E-0. These steps are immediate actions and required to be known from memory.

Explanation of distractors:

A - is incorrect because rod bottom lights are not lit with a loss of MCC-53 1. Upon reactor trip there is no transfer of power which reenergizes this indication. The remainder of the question is correct and therefore makes it plausible.

B - is incorrect because positive trip indication is provided by reactor trip breaker position and neutron flux levels. The crew should remain in E-0 not transition to FR-S. 1.

D - is incorrect because the stem of the question indicates that power is lost to MCC-53 1 de-energizing DRPI indication so rod bottom lights would not be lit. If rod bottom lights were lit an attempt to manually trip the reactor would not be required.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

KIA Topic:

Question Source:

New E-0, Step 1, LP8032i pg 16 None Ability to predict the impacts of Loss of Power to RPIS and based upon those predictions, use procedures to correct, control, or mitigate the consequences.

Question Cognitive Level:

Higher

ES-401 Seabrook Written Examination Question Worksheet Form ES-401-5 10 CFR Part 55 Content:

Learning Objective:

55.4 1.61 10 L8032106RO State the source of power for the DRPI data cabinets and MCB display.

L1202103RO State the basis for the following steps, notes, or cautions contained in E-0 I A steps.

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level Tier #

Question # 58 Group #

WA #

RO SRO 2

2 2

2 01 7.GEN.2.4.24 Importance Rating 3.3 3.7 Proposed Question:

The following plant conditions exist:

The operating crew is responding to FR-C.l, Inadequate Core Cooling.

The crew is unable to re-initiate Emergency Core Cooling (ECCS) flow.

Steam Generator (S/G) depressurization proved ineffective.

All core exit thermocouples (CETs) indicate >1100 F.

S/G narrow range levels are all 30% and increasing.

Reactor Vessel Level Indicating System (RVLIS) indicates 35% and slowly decreasing.

Reactor Coolant Pump (RCP) seal injection startup criteria cannot be established.

Based on these conditions, which of the following actions are required by FR-C.1?

A. Do NOT start RCPs; continue attempts to reestablish ECCS flow.

B. Start RCPs one at a time in any available RCS loop, continue operation of one RCP until CETs are < 1100 F.

C. Do NOT start RCPs; continue attempts to reestablish secondary heat sink.

D. Start RCPs one at a time in any available RCS loop, continue operation of one RCP until CETs are < 725 F.

Proposed Answer:

B Explanation of answer: According to FR-C.l, if CETs are indicating > 1 100 F and narrow range S/G water level is > 5%

(to avoid S/G tube creep), RCPs should be started one at a time in an attempt to reduce CETs -= 1100 F.

Explanation of distractors:

A & C are incorrect because the procedure does direct starting RCPs if there is adequate secondary inventory.

D - incorrect because the procedure loops the operator around until a yes answer to CETs <1100 F is answered or no RCPs are available or until insufficient water is available in the S/Gs.

Technical Reference( s):

Proposed references to be provided to applicants during examination:

K/A Topic:

Question Source:

Bank # 26618 Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

FR-C. 1, Response to Inadequate Core Cooling.

Steam Tables Knowledge of Loss of Cooling Water Procedures related to in-core temperature monitoring.

55.4 1.10 L1227103RO State the basis for the following steps notes, or cautions from FR-C. 1 :

step 18

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

KIA #

028.K2.01 Importance Rating 2.5 2.8 Question # 59 Group #

2 2

Proposed Question:

The hydrogen recombiners (CGC-MM-284m) are powered from which of the following power supplies?

A. MCC-521 and 621.

B. MCC-131 and 142 C. MCC-211 and 261 D. Unit Substation 53 and 63.

Proposed Answer:

A Explanation of answer: The hydrogen recombiners are installed inside the containment and are powered from safeguards MCC 521 and 62 1 according to the HV Detailed system text.

B - incorrect because these are turbine building 2 1 and water treatment non-safety related MCCs C - incorrect because these are non-safety related MCCs.

D-incorrect because it is not the correct power supply, however plausible since it is safety related.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

CHV Detailed System Text, LP8038I Containment CHV None Knowledge of the bus power supplies to the hydrogen recombiners.

~

~~

Question Source:

New Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

55.41.7 L8038107RO Describe the operation of the Hydrogen Recombiners.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

Question # 60 Group #

2 2

WA #

033.A1.01 Importance Rating 2.7 3.3 Proposed Question:

The following plant conditions exist:

0 The plant is in MODE 1.

Spent fuel pool water level LO alarms are received in the control room.

Control room operators enter OS1215.07, Loss of Spent Fuel Pool Cooling as directed by alarm response procedures.

Spent Fuel Pool Level is 21.5 feet and slowly decreasing.

Based on these conditions, which of the following describes a source of EMERGENCY makeup to the Spent Fuel Pool?

A. Refueling Water Storage Tank (RWST).

B. Chemical Volume Control System (CVCS).

C. Demineralized Water Storage Tank (DWST).

D. Secondary Component Cooling Water (SCCW).

Proposed Answer:

A Explanation of answer: Answer is directly from procedure. RWST is the source of water in an emergency situation.

Attachment A also allows CST gravity feed and Fire Protection system fill.

Explanation of distractors:

B & C - incorrect because these sources are specified for normal makeup methods only.

D - incorrect because SCCW is not an alternative for makeup to the SFP.

Technical Reference(s):

OS1 2 15.07 Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

None Ability to predict and/or monitor changes in parameters associated with SFP cooling system operating the controls including spent fuel pool water level.

Modified Bank # 23 150 Original question attached to reference.

55.41.10 L 1 192108RO List the emergency makeup water sources available to the SFP and the preferred order of use IAW attachment A of OS1215.07.

ES-401 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

Question # 6 1 Group #

2 2

WA #

04 1.A4.07 Importance Rating 2.9 3.0 Proposed Question:

The following plant conditions exist:

0 0

The Plant is operating at Full Power.

Control Rods are Full Out in AUTO.

A Condenser Steam Dump Valve fails open and a Nuclear System Operator (NSO) is immediately dispatched to locally isolate this steam dump.

Assume no other operator action occurs.

Given these conditions, what indications will you have in the control room that the NSO has successfully isolated the Condenser Steam Dump?

Reactor Coolant Svstem Tavg Reactor Power A. INCREASES INCREASES B. DECREASES DECREASES C. INCREASES DECREASES D. DECREASES INCREASES Proposed Answer:

C Explanation of answer: The failure of the condenser steam dump valve will result in an increase in steam demand which will increase reactor power and result in a drop in Tavg. As the control rods are in the full out position they will not restore RCS temperature. When the operator shuts the steam dump, steam demand will drop and reactor power will decrease. Since not as much energy is being extracted from the RCS, Tavg will increase. There is no valve indication that lets the control room crew know that this valve is shut and this is an operationally relevant situation.

Explanation of distractors: All other combinations are incorrect.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

L8 124i, Reactivity Coefficients None Ability to manually operate and/or monitor in the control room remote gagging of stuck open relief valves as related to Steam Dumps.

55.4 1.115 L8 12812 1RO Explain the relationship between reactor power and steam flow.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

Question # 62 Group #

2 2

WA #

045.K4.13 Importance Rating 2.6 2.8 Proposed Question:

The following plant conditions exist:

The plant is operating at 18% power with plant conditions established to support Turbine Overspeed Testing.

The crew will be performing this test using ON1431.08, Main Turbine Overspeed Test.

All Pre-job briefings have occurred and permission has been granted to commence testing.

The Balance of Plant Operator depresses and holds the OVERSPEED TEST pushbutton.

Assume all systems function normally as designed.

What Main Turbine Generator System design feature(s), will occur as a result of this action?

When Turbine speed reaches A. 1 lo%, the turbine will automatically trip.

B. 105%, the turbine will automatically trip.

C. 1 lo%, the turbine will be automatically runback.

D. 105%, the turbine will be automatically runback Proposed Answer:

A Explanation of answer: Based on procedural reference and lesson plan, the design of the turbine control system is to automatically trip the turbine once the turbine reaches 110% of 1800 RPM. This test is accomplished by holding the Overspeed test pushbutton. Once the turbine automatically trips the pushbutton is released.

Explanation of distractors:

B - incorrect because the turbine trips at 1 10% vs 105% of rated speed. It is correct that the turbine will auto trip. The 105% value is plausible because during normal operations if turbine speed reaches 105% of rated speed, the control valves will be driven closed by the negative output signal generated by the speed control unit.

C - incorrect because the turbine will auto trip. It is correct that the turbine trips at 110%.

D - Incorrect because again it is an auto trip vs auto runback and trips at 110% vs 105%.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

protection.

Question Source:

New Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

ON143 1.08, MT Overspeed Test, L8049, EHC System Lesson, EHC Detailed System Text None Knowledge of the MT/G system design feature(s) andor interlock(s), which provide for overspeed 55.41.418 L8049I 13R0 State any interlock associated with the EHC pushbuttons and describe their functions.

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

Question # 63 Group #

2 2

WA #

056.K1.03 Importance Rating 2.6 2.6 Proposed Question:

Which one of the following provides water to the shaft seal system for the A Main Feedwater Pump?

A. A MFP discharge.

B. Steam seal condensate.

C. Condensate storage tank.

D. Condensate pump discharge.

Proposed Answer:

D Explanation of answer: This question was used on the 2003 NRC exam and has been validated to be technically correct.

Explanation of distractors: All distractors are incorrect, however, plausible since they are system related.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

and MFW.

Question Source:

Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

FW Detailed System Text pg 8 None Knowledge of the physical connections and/or cause-effect relationships between the condensate system Bank / 2003 NRC RO#36 55.41.4 L8042104RO List the 6 components provided sealing or cooling water by the condensate system.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier ##

2 2

KIA #

068.K6.10 Importance Rating 2.5 2.9 Question ## 64 Group #

2 2

Proposed Question:

Given the following list of Process/Effluent Radiation Monitors:

1.
2.
3.
4.
5.

R-6509, Waste Test Tank Discharge Monitor.

R-6514, Waste Liquid Test Tank Inlet Monitor.

R-6505, Condenser Air Evacuation Discharge Monitor.

R-65 19, Steam Generator Blowdown Flash Tank Discharge Monitor.

R-65 16, Primary Component Cooling Water Loop A Activity Monitor.

An automatic system isolation will occur in response to a loss of power to which of the above radiation monitor combinations?

A. 1 and5.

B. 2and3.

C. 2and4.

D. 3and5.

Proposed Answer:

C Explanation of answer: According to 081252.01 as well as System Lesson L8059i, several process or emuent radiation monitors have automatic control hctions associated with them. #1,2 & 4 above fall into this category. A loss of the radiation monitor will result in these control functions occurring since they are fail safe in the alarm condition. C is the only correct combination of radiation monitors listed which provide these automatic functions. These monitors are all associated with the Liquid Radwaste System. This is operationally relevant because operators should be aware of system isolation status if high radiation should occur to protect the health and safety of the general public.

Explanation of distractors: Any other combination of these detectors is either partially correct or does not have an automatic control function associated with it. All choices are plausible in that they are radiation monitors listed in Attachment A ofOS1252.01.

Technical Reference(s):

OS1252.01, Process or EfNuent High Radiation, RDMS Detailed System Text Table

~

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Modified Bank #23206 Original question attached to reference.

Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

None Knowledge of the effect of a loss or malfunction on the radiation monitors will have on the liquid radwaste system.

55.41.7113 L8059106RO Describe the auto actions (control signals) that result when the below listed monitors reach their alarm setpoints.....

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 2

Question # 65 Group #

2 2

WA #

086.K5.04 Importance Rating 2.9 3.5 Proposed Question:

Which of the following choices correctly identifies the applicable fire typeklass, firelsafety hazard and associated fire protection for the 13.8 kV Unit Auxiliary Transformers?

Fire Tvpe/Class Fire/Safetv Hazard Fire Protection A. ClassA Explosion Halon System B. Class B Explosion Dry-Pipe, Open-Head Sprinkler System C. Class C Electrocution Halon System D. Class D Electrocution Dry-Pipe, Open-Head Sprinkler System Proposed Answer: B Explanation of answer: B is correct because the UAT(s) contain transformer insulating oil which is flammable. The concern is that an internal electrical fault could produce a high temperature before protective systems could de-energize the UAT causing explosion. Therefore, the transformer is surrounded by a dry-pipe, open-head sprinkler system which will spray water on the UATs when actuated to quickly reduce temperature. According to the definitions of fire typesklasses in the Fire Protection Manual, a fire involving energized electrical equipment (Class C) is classified according to construction of components within, so therefore, Class B is most correct because it is a Class I11 liquid having a flash point above 140 F.

Explanation of distractors:

A - is incorrect but plausible because the fire hazard is an explosion, however, it would not be classified as a type A fire nor is Halon an applicable fire protection system in this case since the UATs are located outside.

C - is incorrect but highly plausible since it could be classified as a Class C fire and electrocution is an applicable safety hazard. The Halon system is what makes this choice clearly incorrect. Since fire protection is applicable system knowledge, this distractor is relevant.

D - is incorrect but again highly plausible because the hazard and fire protection is applicable and valid. However, a Class D fire is clearly incorrect since it does not involve burning of magnesium, sodium etc.....

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

Fire Protection Manual Glossary, 13.8 kV Detailed System Text.

None Knowledge of the operational implications of the hazards to personnel as a result of fire type and methods of protection as applied to fire protection system.

55.41.4 L801211 OR0 Describe the UAT/RAT fire protection schemes.

ES-401 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

3 3

Question # 66 Group #

1 1

WA #

GEN 2.1.1 Importance Rating 3.7 3.8 Proposed Question:

In accordance with OP 9.2, Emergency Operating Procedure Users Guide of the Operation Management Manual (OPMM), which of the following is an example of when skill of the operator can be used? (assume in all cases permission has been granted from the Unit Supervisor whether correct or incorrect)

A. Lining up for a normal dilution to the Reactor Coolant System.

B. Manual initiation of Safety Injection when the automatic actuation setpoint is exceeded.

C. Carrying out immediate action of E-0, Reactor Trip or Safety Injection and all equipment functions as designed.

D. Starting an Emergency Diesel Generator and closing its respective breaker after one failed attempt onto its respective bus during a Loss of Offsite Power event.

Proposed Answer:

B Explanation of answer: OP 9.2 specifically uses this choice as an example of when skill of the operator can be used.

Explanation of distractors:

A - incorrect because besides it being a strictly controlled reactivity evolution, it is not a simple task as defined by OP 9.2. Additionally, the system is not deviating from its design function, so there would be no need for skill of the operator. Procedure use would be required.

C - incorrect because although the operator performs these from memory, this is not skill of the operator related because everything is functioning as designed.

D - incorrect because although a component is not functioning as designed (ie: the EDG should have started), it is not a simple in nature and skill of the operator is not to be used for tasks that are beyond routine. The IAs allow one attempt for an emergency start but do not reference closing breakers. If a breaker does not close initially, this goes into troubleshooting and is beyond skill of the operator.

Technical Reference(s):

OP 9.2 OPMM Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

None Knowledge of the conduct of operations requirements.

55.41.10 L1505123RO Describe a Skill of the operator task and when they might be used.

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier ##

3 3

Question # 67 Group #

1 1

KIA ##

GEN 2.1.7 Importance Rating 3.7 4.4 Proposed Question:

At 0300, a plant trip occurred from 100% power and the plant is in MODE 3 at 555 F.

The following events occur:

0 0

The Reactor Operator reports that Tavg has begun decreasing at a rate of approximately 1 F/min.

The Balance of Plant Operator reports that the low setpoint safety valve on the C SG has apparently failed partially open.

A Nuclear Systems Operator is dispatched and visually confirms one of the SG Safety Valves on the C SG is passing steam to the atmosphere.

The Reactor Operator confirms an RCS cooldown rate of 5F in the last 5 minutes.

0 Based on these conditions and assuming constant cooldown rate and NO operator action is taken in response to the stuck open safety valve, which of the following conditions will exist by time 0400?

1.
2.
3.
4.

A.

B.

C.

D.

Main Steamline isolation.

The Tech. Spec. for RCS Cooldown Rate will be exceeded.

The actual amount by which the reactor is shutdown will decrease (Shutdown Margin).

A PTS challenge to reactor vessel integrity will occur.

1 and4 2 Only 3 only 2 and 4 Proposed Answer:

C Explanation of answer: As Tavg is reduced due to the stuck open safety valve, positive reactivity will be inserted into the core from the negative MTC. With rods fully inserted and no change in RCS boron concentration, the actual amount that the reactor is shutdown will decrease over the next hour.

A - is incorrect because with a cooldown rate of 60 Fhr, Tavg will be 495 F by 0400. Steam pressure for this value is 636 psig which is above the MSLI value of 585. Even if the rate of cooldown was enough to actuate the rate compensated portion of MSLI, the answer is still incorrect because A PTS challenge is not a concern as further explained below.

B - is incorrect because the RCS cooldown rate is approximately 60 F h. Tech. Specs. limit the RCS cooldown rate to a maximum of 100Fhr in any one hour period. This limit will not be exceeded.

D - is incorrect because the Integrity Critical Safety Function Status Tree (F-0.4) will remain Green over the next hour because the rate of RCS cooldown is < 100Fhr and RCS temperatures will be approximately 495 F at the end of the one hour period.

Seabrook Written Examination Question Worksheet Form ES-40 1-5 ES-40 1 Technical Reference( s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Bank Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

UFSAR Chapter 15.112, Reactor Theory Fundamentals, TS 3.4.9.2, FR-P. 1 Status Tree Steam Tables, Calculator Ability to evaluate plant performance and make operational judgments based on operating characteristics, reactor behavior, and instrument interpretation.

55.41 & 55.45 L14 11106RO State the core parameter of the most concern for the stuck open steam generator safety valve accident.

L8128128RO Evaluate the change in SDM due to changes in plant parameters.

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

3 3

Question ## 68 Group #

1 1

WA #

GEN 2.1.28 Importance Rating 3.2 3.3 Proposed Question:

Which of the following choices contains ONLY items that are described in 10 CFR 50.46 as acceptance criteria for Emergency Core Cooling System (ECCS) which form the basis for this systems componentkontrol function and design?

I.

11.

111.

IV.

V.

VI.

VII.

The total oxidation shall not exceed 17% of the total cladding thickness.

The calculated maximum fuel element cladding temperature shall not exceed 2200 F.

Calculated changes in core geometry shall be such that the core remains amenable to cooling.

The calculated total amount of hydrogen generated from the zirc-water reaction shall not exceed 0.01 times the amount that would be generated if all the cladding surrounding the fuel were to react.

The calculated total oxidation of the cladding shall nowhere exceed 0.03 times the total cladding thickness before oxidation.

After any successful initial operation of the ECCS, the calculated core temperature shall be maintained at an acceptably low value and decay heat shall be removed for the extended period of time required by the long-lived radioactivity remaining in the core.

The zirc-water reaction postulated to occur at 1800 F will not become self-sustaining under any circumstance.

A. I, 111, V, VI1 B. 11, 111, IV, VI1

c. 111, IV, v, VI D. I, 11, 111, IV Proposed Answer:

D Explanation of answer: 10CFR46 paragraph b delineates the acceptance criteria for a LOCA. Seabrook UFSAR contains the same criteria. The only answer which contains ONLY correct criteria is answer D. All other distractors contain either V or VII, neither of which are correct.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA topic:

Question Source:

New Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

UFSAR Section 6.3, Pg 27, ECC Detailed System Text, Pg 1 None Knowledge of the purpose and function of major system components and controls.

55.41.216 L8034103RO List the five ECCS Acceptance criteria for LOCA's.

ES-401 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

3 3

Question # 69 Group #

2 2

WA #

GEN 2.2.12 Importance Rating 3.0 3.4 Proposed Question:

According to surveillance procedure OX1401.02, RCS Steady State Leak Rate Calculation, which of the following parameters is an input into the calculation for IDENTIFIED RCS leakage?

A. Pressurizer Level B. Containment Sump Level.

C. Integrated Makeup Total.

D. Pressurizer Relief Tank Level.

Proposed Answer:

D Explanation of answer: This procedure is used by operations every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> to determine sources of RCS leakage.

Common misconceptions surrounding sources of IDENTIFIED versus UNIDENTIFIED leakage have in the past led to inaccuracies in these calculations. The surveillance specifies the difference between the two variables in order to comply with Technical Specifications. According to Form B, the PRT is a source of identified RCS leakage.

Explanation of distractors:

All distractors are incorrect however plausible since they are referenced in OX1401.02 as sources of UNIDENTIFIED RCS leakage. The candidate must be able to distinguish between the two sources of which all distractors are credible unidentified sources.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

OX1401.02, TS Section 1 Definitions None Knowledge of surveillance procedures.

55.41.5110 L8010I 1 OR0 State the functions of the surveillance requirements.

L8010103RO Define from memory the following terms as they are found in section 1 of TS----identified & unidentified leakage.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

3 3

Question # 70 Group #

2 2

WA #

GEN 2.2.23 Importance Rating 3.6 3.8 Proposed Question:

The following plant conditions exist:

0 The plant is in Mode 6.

Fuel movements between containment and the fuel storage building are in progress.

Which of the following conditions would require core alterations to be suspended?

A. Direct communications between control room and refueling machine are lost.

B. Direct communications between control room and outage control center are lost.

C. Direct communications between refueling machine and fuel storage building are lost.

D. Direct communications between refueling machine and outage control center are lost.

Proposed Answer:

A Explanation of answer: TR 25-3.9.5 requires direct communications maintained between the control room and personnel at the refueling station. At Seabrook we require both RO and SRO candidates to know from memory the less than 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> TS. This TS has an immediate action to suspend core alterations if communications is lost.

Explanation of distractors:

All distractors are plausible incorrect answers in that they are areas in which the ability to communicate related to refueling is applicable.

Technical Reference(s):

Technical Requirements 25 Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Modified Bank #26135 Original question attached to reference.

Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

None Ability to track limiting conditions for operation.

55.4 1.10 L8060110 Given a plant situation apply the TS LCO action statements & basis related to refueling operations.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

3 3

KIA #

GEN 2.3.1 Question # 7 1 Group #I 3

3 Proposed Question:

Importance Rating 2.6 3.0 The following radiological conditions exist for a room in the plant:

General dose rate levels range from 25 - 45 me&.

Measurements taken on pipes and valves include:

o o

o Point 1 is 100 me&

at 30 cm.

Point 2 is 500 me&

at 30 cm.

Point 3 is 1100 mre&

at 30 cm.

0 The room is accessible to plant personnel.

Based on these conditions what is the radiological posting required for this room and who can authorize an individual to exceed Federal Annual TEDE limits while working in this room during a non-emergency situation?

A. High Radiation Area; Station Director.

B. Technical Specification Locked High Radiation Area; Station Director.

C. High Radiation Area; Nobody can authorize exceeding the Federal Limits.

D. Technical Specification Locked High Radiation Area; Nobody can authorize exceeding the Federal Limits.

Proposed Answer:

D Explanation of answer: In accordance with TS Admm Controls section 6.1 1.2, areas accessible to personnel with radiation levels greater than 1000 mrk @ 30 cm from the radiation source or from any surface that the radiation penetrates shall be provided with locked doors to prevent unauthorized entry. Additionally, according to the radiation protection manual, approval and extension of approvals are applicable only up to the extent of a workers federal limits of 5000 mrem.

Explanation of distractors: All distractors are combinations of plausible incorrect answers or incorrect conditions.

Technical Reference(s):

TS6.11.1 &6.11.2,RP5.1,Pg Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

None Knowledge of 10CFR 20 and related facility radiation control requirements.

55.41.12/13 L1525109RO Define the area designations........

L1525113RO State the required approvals for exposure limit upgrades.

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

3 3

WA #

GEN 2.3.4 Importance Rating 2.5 3.1 Question # 72 Group #

3 3

Proposed Question:

The following plant conditions exist:

0 0

0 0

A Site Area Emergency has been declared due to a Loss of Coolant Accident (LOCA) outside containment.

A pathway to the environment exists.

Limited makeup to the Refieling Water Storage Tank is available.

An operator is sent into the area of the leak for local isolation.

The intended action has all of the required approvals.

The action will result in a significant reduction in offsite dose, protecting a large population.

The operators current TEDE dose is as follows:

0 0

Exposure for the year: 200 mrem Current total lifetime exposure: 1200 mrem Based on these conditions, what is the maximum emergency exposure this operator may receive while perfonning this action?

A. 4800 mrem TEDE B. 10000 mrem TEDE C. 23600 mrem TEDE D. 25000 mrem TEDE Proposed Answer:

D Explanation of answer: Emergency exposure limits for life saving or protection of large populations is 25 Rem.

Explanation of distractors:

A - incorrect however plausible since this dose would bring the workers dose to 5 Rem which is the maximum TEDE dose allowed per year (non-emergency situation).

B - incorrect however plausible since this is the emergency dose limit for protection of valuable property.

C - incorrect however plausible since this would bring the worker dose to 25 R for the year, which is the emergency limit, but this limit is independent of previous dose.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

ER 4.3, Pg 5-7, Figure 2 & 3.

None Knowledge of radiation exposure limits and contamination control, including permissible levels in excess of those authorized.

55.4 1.1211 3 L1525113RO State the required approvals for exposure limit upgrades.

ES-401 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level Tier #

Question # 73 Group #

WA #

RO SRO 3

3 3

3 GEN 2.3.1 1 Importance Rating 2.7 3.2 Proposed Question:

The following plant conditions exist:

The crew is reducing containment pressure in accordance with OS1023.69, Containment On-Line Purge (COP)

System Operation.

COP Exhaust Containment Isolation Valves COP-V-3 and COP-V-4 have been opened.

The crew is establishing COP flow through COP-V-8, COP Exhaust Throttle Valve (Coarse Control).

RM-6527A-1 and RM-6527A-2, Train A COP go into HIGH alarm.

Assume all systems h c t i o n as designed.

Based on these conditions, which of the following choices describes how the control room crew will control the radiological release?

A. Control room operators must ensure COP-V-4 automatically closes to stop the release.

B. Control room operators must ensure COP-V-3 and COP-V-8 automatically close to stop the release.

C. Control room operators must ensure COP-V-4 and COP-V-8 automatically close to stop the release.

D. Control room operators must manually close COP-V-3 and COP-V-4 since no automatic actions will occur.

Proposed Answer:

A Explanation of answer: COP Valves (3 & 4) receive an automatic CVI signal to close when high radiation is sensed.

COP Valves 1 & 4 are Train A. COP Valves 2 & 3 are Train B.

Explanation of distractors:

B - incorrect because COP-V-8 does not receive an auto signal nor does it need to be closed to stop the release.

C - incorrect because again COP-V-8 does not receive a CVI signal. Also in ths case COP-V-4 is a Train Ava1ve and will receive a signal.

D - incorrect because COP-V-3 will not auto close. It is plausible that COP-V-4 will receive an auto signal since it is in the A Train. Only one valve needs to close to isolate the release.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Bank #22062 Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

CHV Detailed System Text None Ability to control radiation releases.

55.4 1.7113 L8059106RO Describe the auto actions (control signals) that result when the below listed monitors reach their alarm setpoints.........

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level Tier #

Question # 74 Group #

WA #

Importance Rating Proposed Question:

RO SRO 3

3 4

4 GEN 2.4.48 3.5 3.8 Given the following plant conditions and sequence of events:

The plant is operating at 75% power.

A manual boration is directed by the Unit Supervisor.

All control systems are in AUTOMATIC.

The Reactor Operator then inadvertently opens the emergency boration valve (CS-V-426) instead of the boration flow control valve (CS-FCV-1 10A) and then turns the BLENDER MODE START Switch to START which successfilly starts a boric acid pump.

Based on these conditions, which of the following symptoms would indicate that CS-V-426 was inadvertently opened instead CS-FCV-1 10A? (assume the operator took no other action)

A. Tavg remains steady, the makeup batch flow indicator controller (CS-FIQ-Ill) does NOT sense system flow, control rods begin to step out.

B. Tavg begins to decrease, the makeup batch flow indicator controller (CS-FIQ-Ill) does sense system flow, control rods begin to step in.

Tavg begins to decrease, the makeup batch flow indicator controller (CS-FIQ-1 control rods begin to step out.

D. Tavg begins to decrease, the makeup batch flow indicator controller (CS-FIQ-I rods begin to step out.

C.

1) does NOT sense system flow,
1) does sense system flow, control Proposed Answer:

C Explanation of answer: Opening CS-V-426 is the method used in the Rapid Boration AOP and in FR-S. 1 to injects large quantities of boric acid directly from the RWST or BWST to the CCP suction. This negative reactivity also causes RCS temperature to drop. As a result of dropping RCS temperature with control rods in normal they will begin to step out once Tavg is 1.5 F is lower than Tref. The impact on the RMUW controls is that it is essentially bypassed and will not sense the boric acid flow, therefore the controllers do not count down the amount of boric acid selected to be added.

Explanation of distractors:

A - incorrect because Tavg drops vs remaining steady. All other portions of answer are plausible.

B - incorrect because rods step out with lowering Tavg. Additionally, the controller does not sense flow.

D - incorrect because the controller does not sense flow. All other portions of answer are plausible, Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New RMU Detailed System Text, L8025i RMUW System None Ability to interpret control room indications to verify the status and operation of system, and understand how operator actions and directives affect plant system conditions.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-401-5 Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

55.4 1.1/5/6 L8025112RO Describe the operations of the ABB boric acid makeup flow, total makeup flow, and makeup batch flow controllers.

L8 1241 1 1RO Describe the effects of boratioddilution on reactivity.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

3 3

Question # 75 Group #

4 4

WA #

GEN 2.4.49 Proposed Question:

Importance Rating 4.0 4.0 The following plant conditions exist:

The reactor failed to trip on demand.

The crew has entered FR-S. 1,Response to Nuclear Power GeneratiodATWS.

The Reactor Operator is manually driving control rods inward.

The Balance of Plant Operator tripped the turbine and noted #2 stop valve indicates 10% open.

Based on these conditions, what procedurally driven action must the crew perform next?

A. Manually runback the turbine.

B. Immediately open the generator breaker.

C. Close the Main Steam Isolation Valves and bypass valves.

D. Open the generator breaker when generator ouput is ZERO Mwe.

Proposed Answer:

A Explanation of answer: Refer to immediate step #2 of FR-S. 1. The first item to perform is a turbine runback if the turbine does not trip.

Explanation of Distractors:

B - incorrect because the RNO says to open the output breaker after verifying turbine Mwe at ZERO.

C - incorrect because it is after running back the turbine.

D - incorrect because although a correct step again it is out of order and performed last.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Ability to perform without reference to procedures those actions that require immediate operation of system components and controls.

Question Source:

Bank #22661 Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

FR-S. 1, Step 2 None 55.4 1.10 L 120010 1 RO List from memory IA steps including RNOs.

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level Tier #

Question # 76 Group #

WA #

RO SRO 1

1 EPE.009.EA2.04 Importance Rating 4.0 Proposed Question:

The following plant conditions exist:

0 0

0 A reactor trip and safety injection have occurred.

The crew is responding to a Small Break Loss of Coolant Accident (LOCA).

All Reactor Coolant Pumps are tripped.

The crew is depressurizing the Reactor Coolant System (RCS) in accordance with Step 1 1 of ES-1.2, Post LOCA Cooldown and Depressurization.

A PORV is being used to depressurize the RCS until Pressurizer level is > 25% (50% adverse).

Based on these conditions, as the depressurization occurs what is the expected trend of PZR level and what adverse operating condition may INITIALLY occur as a result?

A. DECREASING PZR Level; Uncovering PZR heaters.

B. INCREASING PZR Level; Water solid conditions in the PZR.

C. INCREASING PZR Level; Upper head region voiding may occur.

D. DECREASING PZR Level; Upper head region voiding may occur.

Proposed Answer:

C Explanation of answer: The caution prior to commencing depressurization in ES-1.2 to refill the PZR, states that a head void may occur as indicated by a increasing PZR level as water in transferred from the RCS to the PZR.

Explanation of distractors:

A - incorrect because PZR will increase during depressurization versus decrease. It is plausible that if the operator does not understand this concept and they believe PZR level will drop that the heaters would become uncovered which is an undesirable condition.

B - incorrect because although it is correct that PZR level will increase and it is plausible that eventually the PZR would go solid, that this would not INITIALLY occur.

D - incorrect because PZR level will increase vs. decrease. The reason is plausible and tests whether the student correctly understands the important concept.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Question Cognitive Level:

Higher 10 CFR Part 55 Content:

55.43.5 Learning Objective:

L1204103RO Summarize the major action of ES-1.2.

ES-1.2, Pg 9, WOG B/G Document for ES-1.2 caution prior to step 11.

None Ability to determine or interpret PZR level as applied to a SBLOCA.

Modified Bank #497 1 Original question attached to reference.

Seabrook Written Examination Question Worksheet Form ES-401-5 ES-401 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Question # 77 Group ##

1 WA #

APE01 510 17.AA2.11 Importance Rating 3.8 Proposed Question:

The following plant conditions exist:

0 0

A Loss of Coolant Accident has occurred.

Currently the crew is performing the steps of FR-C.1, Response to Inadequate Core Cooling and preparations are being made to start the C Reactor Coolant Pump (RCP).

Core Exit Thermocouples are approximately 1205 F.

Steam Generators (S/G) are depressurized to 85 psig.

Reactor Coolant System pressure is 1400 psig and increasing.

C S/G level is 50% Narrow Range.

0 Based on these conditions, WHICH of the following choices must the Unit Supervisor require prior to directing a start of the C RCP?

ADEQUATE S/G INVENTORY LIFT OIL INTERLOCK SEAL DP > 220 PSID A.

Satisfied Required Required B.

Satisfied NOT Required NOT Required C.

NOT Satisfied Required Required D.

NOT Satisfied NOT Required NOT Required Proposed Answer:

A Explanation of answer: Per the note prior to step 18 of FR-C. 1, normal conditions in this situation are desired but not required to start RCPs. However, the starting interlockslpermissives must be met which are the lift oil pump and minimum seal differential pressure. Additionally, the SRO should be aware of the S/G tube creep issue of starting RCPs when inadequate inventory in the S/G is available with high RCS temperatures (in this case >1100F) which can lead to S/G tube ruptures. Whether the containment is adverse or not, with S/G NR Level > 25%, S/G inventory is satisfied.

Explanation of distractors:

All distractors are credible since they contain combinations which are similar and are designed to discriminate between competent supervisors.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

FR-C. 1, Pg 10, RC Detailed System Text None Ability to determine and interpret when to jog RCPs during ICC as applied to RCP malfunctions.

55.43.115 L1227103RO State the basis for the following notes, steps, cautions from FR-C. 1.

L802 1I33RO Describe the MCB RCP controls including control interlocks.

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level Tier #

Question # 78 Group #

WA #

RO SRO 1

1 APE.022.GEN.2.4.44 Importance Rating 4.0 Proposed Question:

The following plant conditions exist:

0 0

The Short Term Emergency Director declared a Site Area Emergency at 1215 due to a Loss of make-up capability to the Reactor Coolant System suffered as a result of an armed intruder attack.

The initial report to the state and local government was completed at 1217.

A Vital Area of the plant has been occupied by armed intruders.

An upgrade to a general emergency was declared at 1230.

Based on todays date, the Protective Action Recommendation (PAR) to the state must be given by which of the following times?

A. 1230 B. 1245 C. 1300 D. 1317 Proposed Answer:

B Explanation of answer: PAR must be made within 15 minutes of declaration of a GE.

Explanation of distractors: All distractors are plausible but incorrect as they are intervals of the given time in the stem.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Lower 10 CFR Part 55 Content:

55.43.1 Learning Objective:

ER-1.1 pg 3 and ER-1.2 pg 1 of 6 None Knowledge of emergency plan protective action recommendations.

L1509119RO State the time requirement related to the following: PARS.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Question # 79 Group #

1 WA #

APE027.AA2.15 Importance Rating 4.0 Proposed Question:

The following plant conditions and sequence of events:

Seabrook is operating at 50% power with all control systems in AUTOMATIC.

The controlling Pressurizer (PZR) Pressure Channel slowly fails high.

The Reactor Operator reports pressure is 1940 psig and slowly dropping.

The Unit Supervisor enters OS1201.06, PZR Pressure InstrumentKomponent Failure.

Attempts to close RC-PCV-455A (PZR Spray Valve) are unsuccessful.

Based on these conditions, which of the following actions should you direct as Unit Supervisor?

A. Commence a power reduction, and raise charging flow to compress the PZR bubble.

B. Trip the reactor, initiate safety injection, and enter E-0, Reactor Trip or Safety Injection, while concurrently tripping the A RCP.

C. Energize ALL PZR heaters, commence a rapid power reduction in anticipation of tripping the reactor and stopping ALL Reactor Coolant Pumps.

D. Trip the reactor, when immediate actions of E-0, Reactor Trip or Safety Injection, are complete, stop the C RCP and up to two more RCPs as necessary to stop RCS pressure drop.

Proposed Answer:

D Explanation of answer: A failure of the controlling pressurizer channel high will cause spray valves to open and RCS pressure to drop. According to step 2 of OS 1206.0 1, if spray control has failed and PZR pressure drops to < 1945 psig, the reactor should be tripped and after IAs, the C RCP should be stopped. Base on Salem OE, the abnormal has been changed to reflect the fact that additional RCPs may need to be secured to stop the RCS pressure drop.

Explanation of distractors:

A - incorrect because although it might be plausible to reduce power, it is not procedurally driven and because pressure is so low would be conservative to trip the reactor iaw OS1206.01.

B - incorrect although plausible because tripping the reactor is correct and recently Seabrook has aligned ourselves with the industry with regard to initiating SI after tripping the reactor. However, in this case, SI is not required until <1800 psig, so this action would be incorrect. Additionally, the A RCP is associated with the B Spray Valve (human factoring)

C - incorrect because this is non-procedurally driven and non-conservative in this situation. Additionally, stopping all RCPs is not desirable or correct as forced circulation is better than natural circulation.

Technical Reference(s):

OS1201.06 step 2.

Proposed references to be provided to applicants during examination:

WA Topic:

PZR pressure control malfunctions.

Question Source:

New Question Cognitive Level:

Higher 10 CFR Part 55 Content:

55.43.5 Learning Objective:

L1182105RO Summarize the major actions for OS1201.06.

None Ability to determine and interpret actions to be taken if PZR pressure instrument fails high as applied to L

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Question # 80 Group #

1 WA #

APE. 05 6.GEN.2.4.7 Importance Rating 3.8 Proposed Question:

The following plant conditions exist:

A Loss of Off-Site Power event is in progress.

The crew is preparing to perform a cooldown using ES-0.2, Natural Circulation Cooldown Only one CRDM fan is available.

How does having only one CRDM fan impact the natural circulation cooldown?

A. The crew will go to ES-0.3, Natural Circulation Cooldown with Steam Void in Vessel (With RVLIS).

B. The crew will maintain the natural circulation cooldown rate LESS THAN 50 F h, and subcooling GREATER THAN 50 F ONLY.

C. The crew will maintain the natural circulation cooldown rate BETWEEN 30 - 50 F h, and subcooling BETWEEN 100 - 130 F ONLY and depressurize the plant WITHIN 88 hours0.00102 days <br />0.0244 hours <br />1.455026e-4 weeks <br />3.3484e-5 months <br />.

D. The crew will maintain the natural circulation cooldown rate BETWEEN 30 - 50 F h, and subcooling BETWEEN 100 - 130 F and NOT depressurize the RCS for 88 hours0.00102 days <br />0.0244 hours <br />1.455026e-4 weeks <br />3.3484e-5 months <br />.

Proposed Answer:

D Explanation of answer: With less than 2 CRDM fans available, cooling of the upper head and subsequent potential for head voiding is a concern. Therefore additional restrictions are placed on the cooldown and depressurization. D correctly depicts the requirements of ES-0.2 when <2 CRDM fans are running.

Explanation of distractors:

A - incorrect because entry into ES-0.3 is required only if the cooldown and depressurization rate are performed at a rate where a steam void may form in the vessel head. Procedurally there is no transition to this procedure based on insufficient CRDM fans.

B - incorrect because, although these are requirements of ES-0.2, they do not apply to this situation.

C - incorrect however plausible. It is not completely correct however because depressurization is not to occur until after the 88 hour0.00102 days <br />0.0244 hours <br />1.455026e-4 weeks <br />3.3484e-5 months <br /> soak to ensure the heat is transferred across the vessel head, therefore only D contain all the elements of a correct answer.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

ES-0.2, Natural Circulation Cooldown.

None Knowledge of EOP based mitigation strategies.

55.43.1/5 L1225114RO State the basis for all procedure steps found in ES-0.2.

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Question # 8 1 Group #

1 WA #

W/El1.GEN.2.1.9 Importance Rating 4.0 Proposed Question:

With the plant at 100% power, the following sequence of events occurs:

0 A Loss of Coolant Accident (LOCA) outside containment occurs, resulting in a reactor trip and safety injection.

The crew is responding using ECA-1.2, LOCA Outside Containment.

RWST level is 325,000 gallons and slowly decreasing.

PZR Level is 65% and slowly decreasing.

While attempting to isolate the break, the final valve the crew closes to isolate the break is the Residual Heat Removal Train B cross-connect valve (RH-V-2 1).

After closing RH-V-2 1, the Reactor Operator reports RCS pressure is still slowly decreasing.

0 Based on these conditions, which procedure will you as Unit Supervisor transition to from ECA-1.2?

A. ES-1.1, SI Termination.

B. ES-1.3. Transfer to Cold Leg Recirculation C. E-1, Loss of Reactor or Secondary Coolant D. ECA-1.1, Loss of Emergency Coolant Recirculation.

Proposed Answer:

D Explanation of answer: D is correct because after isolation of RH-V-2 1, it should be determined that the break is not isolated because RCS pressure continues to drop and is not increasing. Therefore step 5 of ECA-1.2 requires transition Explanation if distractors:

A - is incorrect but plausible because if the break was isolated the crew would go to E-1 and eventually to ES-1.1 to terminate SI.

B - incorrect because because during a LOCA outside containment, a loss of recirculation capability exists.

C - incorrect but plausible since step 5 directs transition to E-1 if the break is isolated.

to ECA-1.1.

Technical Reference@):

ECA-1.2, Step 5 Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Higher 10 CFR Part 55 Content:

5 5.43.5 Learning Objective:

L1209105RO Summarize the major actions of ECA-I.2.

None Ability to direct personnel activities inside the control room.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Question # 82 Group #

2 WA #

APE.OOS.GEN.2.1.7 Importance Rating 4.4 Proposed Question:

Given the following plant conditions and sequence of events:

The unit is operating at 100% power at End of Life.

The Reactor Operator (RO) manually inserts Control Bank C during quarterly Rod Operability testing.

The RO reports that one control rod in Bank C, Group 1, failed to move inward.

The affected rod is indicating 228 steps withdrawn on the Digital Rod Position Indication (DRPI) display.

The Control Bank C Group 1 and Group 2 step counters both indicate 215 steps.

The affected rod is being realigned in accordance with OS1210.06, Misaligned Control Rod.

What action must be taken if the affected rod will NOT move?

A. Enter OS1202.04, Rapid Boration B. Trip the reactor and enter E-0, Reactor Trip or Safety Injection C. Realign the control rods in Control Bank C, Groupl, by withdrawing the unaffected Control Bank C, Group 1 control rods to 228 steps.

D. Place all lift coil disconnect switches for the affected bank to ROD CONNECTED and enter OS12 10.02, Failure of Control Rod or Rod Bank to Move.

Proposed Answer:

D Explanation of answer: Misaligned Control Rod (OS1210.06) is entered when one or more rod position indications are not in agreement with the other rod group indications of the same group by 12 steps or more. Step 6c directs the operator to insert the affected rod to the same DRPI position as the group. If this is unsuccessfid, the RNO directs entry into OS1210.02 after placing all lift coil switches for affected bank to rod connected.

Explanation of distractors:

A - incorrect because more than one rod would have to fail to insert during a normal shutdown for this to be applicable.

It is plausible because it is a caution up front in this procedure.

B - incorrect because more than one rod would have to be misaligned by greater than 48 steps for this to apply. It is plausible because it is mentioned in step 2 of OS 12 10.06.

C - incorrect because this would be the action taken if the misaligned rod is low versus high which is plausible as it is directed by step 7 of this procedure.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Bank #18561 Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

OS 12 1 O.O6/OS 12 10.02 None Ability to evaluate plant performance and make operational judgments based on operating characteristics, reactor behavior, and instrument interpretation as related to an Inoperable/Stuck Control Rod.

55.43.21516 L1185110RO Summarize the major actions of OS1210.06.

L1185112RO For rods misaligned, both high and low as compared to affected bank position summarize the basic recovery method employed.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Question # 83 Group #

2 WA #

APE.037.AA2.16 Importance Rating 4.3 Proposed Question:

Given the following plant conditions and sequence of events:

0 0

The crew has determined that a steam generator (S/G) tube leak exists in both the A and C S/Gs.

While processing through 081227.02, S/G Tube Leak, the crew determines that they are unable to maintain Pressurizer Level with two Centrifugal Charging pumps running and decide to trip the reactor and actuate safety injection.

After proceeding through E-0, Reactor Trip or Safety Injection, the Unit Supervisor transitions to E-3, S/G Tube Rupture, identifies both A and C S/Gs are ruptured and proceeds to the step 7, Initiate RCS Cooldown.

The Reactor Operator reports S/G Pressures as follows:

0 o

o o

o A S/G is 925 psig B S/G is 875 psig C S/G is 1 125 psig D S/G is 1100 psig Based on these conditions, and using the attached step from E-3, what is the target temperature that you will select for the RCS cooldown?

A. 465F B. 470F C. 475F D. 480F Proposed Answer:

B Explanation of answer: The referenced step requires the cooldown be performed based on the lowest ruptured S/G pressure. Both A & C are leaking. A S/G has the lowest pressure and so conservatively, the required temperature based on 900 psig is 470 F. In addition the student must understand that interpolation is not allowed.

Explanation of distractor:

A - incorrect but plausible if the operator misreads and goes for the B S/G which has the lowest pressure based on EFW pump source of steam.

C - incorrect value which falls within the consistent numbering scheme.

D - incorrect however plausible if the operator does not understand that the temperature is based on pressure equal to or less than. It is always conservative to cooldown to the lower value to ensure sufficient subcooling prior or depressurization.

Technical Reference(s):

E-3, Step 7 Proposed references to be provided to applicants during examination:

WA Topic:

E-3, Step 7 Ability to determine and interpret the pressure at which to maintain RCS during S/G cooldown as applied

ES-401 Seabrook Written Examination Question Worksheet FOXTI ES-40 1-5 Question Source:

Bank Question Cognitive Level:

Higher 10 CFR Part 55 Content:

55.43.115 Learning Objective:

L1205107RO Using the RCS cooldown table in E-3, determine CET based on steam generator pressure.

Number Title E-3 STEAM GENERATOR TUBE RUPTURE STEP I ACTION/EXPECTED RESPONSE I

RESPONSE NOT OBTAINED Rev./Date 32 01 107104 CAUTION 0

RCP trip criteria does not apply after a controlled cooldown is initiated.

If NO RCPs running, ECCS flow may cause the affected RCS loop cold leg temperature to indicate less than 250°F: If this occurs, FR-P. 1, RESPONSE TO lMMlNENT PRESSURIZED THERMAL SHOCK CONDITIONS should not be implemented until after performing Step 29 After the low steamline pressure SI is blocked, a high steam pressure rat signal will cause a steamline isolation.

NOTE 7

  • Initiate RCS Cooldown:
a. Determine required core exit temperature based on pressure equal to or less than the lowest ruptured SG pressure:

LOWEST RUPTURED SG PRESSURE (PSIG) 1150 1 I00 1050 1000 950 900 850 800 750 CORE EXIT TEMP.

(OF) NORMAL OR ADVERSE 500 495 490 485 480 470 465 460 450 LOWEST RUPTURED SG PRESSURE (PSIG) 700 650 600 550 500 450 400 350 Step continued on the next page.

~~

CORE EXIT TEMP. (OF)

NORMAL OR ADVERSE 445 435 425 420 410 400 385 375 7 of 39

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

1 Question # 84 Group #

2 WA #

APE.068.AA2.O 1 Importance Rating 4.3 Proposed Question:

The following plant conditions exist:

The plant is operating at 50% power.

The crew is required to evacuate the control room and enters OS1200.02, Safe Shutdown and Cooldown from the Remote Safe Shutdown Facilities.

Based on these conditions, where will the Unit Supervisor go to monitor Steam Oenerator Water Levels?

A. Switchgear rooms where uncompensated wide range levels can be obtained.

B. Switchgear rooms where density compensated wide range levels can be obtained.

C. Emergency Feedwater pump room density compensated wide range levels can be obtained.

D. Emergency Feedwater pump room where uncompensated wide range levels can be obtained.

Proposed Answer:

A Explanation of answer: The US normal operating station outside the control room is CP-108 A & B which are located in the switchgear rooms. The US should be aware based on monthly surveillance that the S/G water levels at CP-108 are uncompensated S/G water levels.

Explanation of distractors: C & D are incorrect locations. B & C are incorrect because they reference density compensated water levels.

Technical Reference(s):

OX1400.01, Remote Safe Shutdown System Monthly Channel Check OS1200.02, Safe Shutdown and Cooldown from the Remote Safe Shutdown Facilities Applicable portions of OX1400.01 Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

Ability to determine and interpret S/G level as applied to Control Room Evacuation.

55.43.115 L82 1 OI05RO State the basis of caution, notes, steps of OS 1200.02.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level Tier #

Question # 85 Group #

KIA #

RO SRO 1

2 WfE03.EA2.1 Importance Rating 4.2 Proposed Question:

Given the following plant conditions:

The unit has tripped and experienced a safety injection.

While performing ES-1.2, Post LOCA Cooldown and Depressurization, an ORANGE path condition was noted for the Core Cooling Critical Safety Function.

FR-C.2, Response to Degraded Core Cooling was entered in response to this condition.

While performing steps of this procedure, the Shift Manager/Shift Technical Advisor reports a RED path condition exists for Core Cooling Critical Safety Function Simultaneously a RED path conditions exists for the Containment Critical Safety Function.

NO other abnormal conditions were noted.

Based on these plant conditions, which of the following is the appropriate action for the Unit Supervisor to take?

A. Complete actions of FR-C.2, and then transition to FR-Z. 1.

B. Complete actions of FR-C.2, and then transition to FR-C. 1.

C. Stop performing FR-C.2, and immediately transition to FR-Z. 1.

D. Stop performing FR-C.2, and immediately transition to FR-C.l.

Proposed Answer:

D Explanation of answer: Per OP-9.2, Rules of usage, when a Red path is encountered, immediately initiate the FRP. Because FR-C. 1 is a higher priority than FR-Z. 1, the US should proceed to FR-C. 1 vs. FR-Z. 1.

Explanation of distractors: All distractors are not in accordance with rules of usage, however, plausible if these rules are not understood.

Technical Reference( s) :

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Higher 10 CFR Part 55 Content:

55.43.5 Learning Objective:

L1196103RO State the priority to be used when given multiple challenged CSFs.

OP-9.2, Section 4.3 None Ability to operate andor monitor facility conditions and selection of appropriate procedures during abnormal and emergency operations as applied to LOCA cooldown and depressurization

Seabrook Written Examination Question Worksheet Form ES-40 1-5 ES-401 Examination Outline Cross-reference:

Level RO SRO Tier #

2 WA #

Question # 86 Group #

1 003.GEN.2.2.25 Importance Rating 3.7 Proposed Question:

Technical Specification 3.4.1.1 requires all Reactor Coolant loops be in operation in Modes 1 and 2. Which of the following describes the basis for this Technical Specification?

A. To ensure uniform differential temperature across each loop.

B. To ensure DNBR remains above 1.30 during all normal operations and anticipated transients.

C. To ensure even distribution of flow through the core to prevent exceeding excessive KW/FT limits.

D. To ensure maximum reactor coolant system flow so that boron concentration in all loops is uniform with the reactor vessel and pressurizer.

Proposed Answer:

B Explanation of answer: The plant is designed to operate with all reactor coolant loops in Modes 1 & 2 and to maintain DNBR above 1.30 during all normal and anticipated transients. All distractors are plausible bases for other specifications or precautions for operations.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Knowledge of the bases in TS for LCO and safety limits associated with reactor coolant pumps.

Question Source:

Bank #3357 Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

TS 3.4.1.1 and associated basis None 55.43.2 L802 1 I lOSRO Describe the basis for TS 3.4.1.1 that requires all RCS loops to be in operation in Modes 1 & 2.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level Tier #

Question # 87 Group #

WA #

RO SRO 9

L 1

004.A2.06 Proposed Question:

Importance Rating 4.3 Given the following plant conditions:

A reactor startup is in progress using OS1000.07, Approach to Criticality.

During the first control bank rod withdrawal, VAS alarm D5972 (Boron Dilution Monitor Train B) is received.

The operator reports that the A Boron Dilution Monitor is also in alarm.

Given these conditions, what action, if any, should be taken by the Unit Supervisor (US)?

A. Initiate rapid boration in accordance with OS 1202.04, Rapid Boration B. Stop the startup and recalculate the estimated critical position using RS 1735, Reactivity Calculations C. Reset or leave in the alarm condition at the discretion of the US and continue with the approach to criticality using OS1000.07.

D. Place the alarm BLOCK switches at the bottom of the Nuclear Instrument cabinet to BLOCK and continue with the approach to criticality using OS1 000.07.

Proposed Answer:

C Explanation of answer: OS1000.07 allows these alarms to be left in alarm or reset during the startup. The operator should understand the meaning and impact of these alarms.

Explanation of distractors:

A - incorrect however plausible if the operator does not understand the meaning of the alarm which is really based on monitoring inadvertent dilutions during shutdown conditions. A rapid boration would be the appropriate action to take in a non-startup situation neutron count-rate increase situation.

B - Incorrect but plausible since other actions within the startup procedure would require this action, such as indications of premature criticality etc.

D - incorrect because the alarms are turned off automatically when neutron countrate exceeds 10000 cps.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Bank #26239 Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

OS 1000.07, Pg 8 Note None Ability to predict the impacts of inadvertent boratioddilution on the CVCS and based on those predications, use procedures to correct, control, or mitigate the consequences.

55.43.516 L1162103RO Summarize the major steps of OS1000.07.

ES-40 1 Seabrook Written Examination Question Worksheet FOITII ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 Question # 88 Group #

1 WA #

013.A2.06 Proposed Question:

Importance Rating 4.0 Given the following plant conditions:

The Reactor Operator reports the following valves have repositioned CLOSED.

o o

CS-V149, Letdown Line Containment Isolation.

CS-V167, RCP Seal Water Return All systems function as designed.

Based on these conditions, what procedure should you enter as the Unit Supervisor and what impact would this event cause if no operator action were to occur?

Procedural Reference Predicted Plant Impact A. OS 1205.01, Inadvertent Phase A Containment Isolation B. OS 1205.O 1, Inadvertent Phase A Containment Isolation Automatic reactor trip on low PZR level.

Automatic reactor trip on high PZR level.

C. OS1290.01, Response to HELB Systems Actuation or Malfunction Automatic reactor trip on low PZR level.

D. OS1290.01, Response to HELB Systems Actuation or Malfunction Automatic reactor trip on high PZR level.

Proposed Answer:

B Explanation of answer: These alarms are consistent with the entry conditions for OS1205.01. Either train of isolation will cause letdown to isolate and pressurizer level to increase to the high PZR level reactor trip setpoint.

Explanation of distractors:

A - incorrect because the reactor trips on high vs. low PZR level. It is plausible that the US should enter OS1205.01.

C/D - incorrect because the HELB procedure is not the correct procedure to enter and although letdown will also isolate, PZR will go high vs. low.

Technical Reference(s):

OS1205.01 & OS1290.01 Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

None Ability to predict the impacts of inadvertent ESFAS actuation and based on predications, use procedures to correct, control, or mitigate the consequences.

55.43.5 L1181115RO Summarize the major actions of 1205.01.

L118 1 I1 4R0 Recognize entry conditions for OS 1205.O 1.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Question # 89 Level Tier #

Group #

WA #

Importance Rating RO SRO 2

1 059.A2.07 3.3 Proposed Question:

Given the following plant conditions:

The plant is at 100% power.

Both Main Feedwater Pumps trip.

All Safeguards systems perform as designed.

Based on these plant conditions, which of the following choices correctly states impact and correct mitigation strategy?

A. Plant will trip directly on AMSAC actuation circuitry, Emergency Feedwater will automatically actuate, safety limits are exceeded, enter E-0, Reactor Trip or Safety Injection.

B. Plant will trip directly on low-low steam generator level, Emergency Feedwater will automatically actuate, NO safety limits are exceeded, enter E-0, Reactor Trip or Safety Injection.

C. Plant will runback to lower power level within the capacity of Emergency Feedwater which will automatically actuate, safety limits will be exceeded, enter OS 123 1.03, Turbine Runback-Setback.

D. Plant will setback to lower power level within the capacity of Emergency Feedwater which will automatically actuate, NO safety limits will be exceeded, enter OS123 1.03, Turbine Runback-Setback.

Proposed Answer:

B Explanation of answer: A loss of both MFPs from 100% power will result in a direct reactor trip on Lo-Lo S/G Level.

This trip is designed to provide protection such that no safety limits are exceeded. The correct procedure to mitigate this ANS Condition I1 event is E-0 which is designed to verify actuation of EFW system to ensure continued heat sink.

Explanation of distractors:

A - incorrect however plausible because the AMSAC system is a backup system designed to provide protection during an ATWS event in the event of a complete loss of feedwater flow. It is also true that EFW will auto actuate since this is part of AMSAC design, no safety limits are exceeded and E-0 is the correct procedure to enter.

C - incorrect however plausible because a runback will occur, however at power levels greater than 85%, the plant cannot sustain a loss of 1 MFP. With both MFP lost, the runback will be overshadowed by loss of S/G inventory and subsequent reactor trip at about the same time EFW auto start occurs. The runback procedure would be correct if the reactor trip did not occur. It is not true that a safety limit will be exceeded.

D - incorrect for most of the reasons above, however even more plausible because it is true that safety limits will not be exceeded.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

UFSAR Section 15.2, Decrease in Heat Removal by Secondary System, L1400I Reactor Trips and Bases.

None

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 KIA Topic:

Ability to predict the impacts of tripping of MFW pump turbine on MFW and based on those predictions, use procedures to correct, control, or mitigate the consequences of the loss of MFW pump turbine.

Question Source:

Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

Modified Bank #163 17 Original question attached to reference.

55.43.115 L1400102R0, Describe the basis for each of the reactor trips and the purpose of all permissive and control interlocks.

L8056118RO Given any Reactor trip signal, state an accident or unsafe condition the trip is designed to provide protections against.

ES-401 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 K/A #

061.GEN.2.1.32 Importance Rating 3.8 Question # 90 Group #

1 Proposed Question:

The following plant conditions exist:

The reactor has tripped from 80% power.

The crew has transitioned to OS1 000.1 1 Post Trip to Hot Standby Which of the following describes the conditions that must be procedurally met for the crew to BYPASS the Startup Feedwater Pump (SUFP) LOW suction trip?

A. CST makeup capability is unavailable and level is less than 230,000 gallons.

B. CST has been shifted to the lower tap and level is less than 230,000 gallons.

C. CST makeup capability is unavailable and the SUFP is the only method to feed steam generators.

D. CST has been shifted to the lower tap and the SUFP is supplying steam generators via EFW cross-connect.

Proposed Answer:

D Explanation of answer: SROs are required to know the basis of TS of which 3.7.1.2 and 3.7.1.3 apply.

OS 1000.1 1 requires that the SUFP low suction trip may be bypassed only if the CST has been shifted to the lower tap and the SUFP is supplying the S/Gs via cross connect. The Seabrook CST is undersized and <2 15,000 gallons will cause a SUFP trip if realignment is not made. Realignment to the lower tap and via the cross connect extends the amount of NPSH to complete plant cooldown if necessary. Explanation of distractors: All distractors are plausible since they either contain some combination of the correct answer or they relate to precaution 3.4 which is a different issue.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Totic:

OS1000.11, pg 4 Precaution 3.3/TS 3.7.1.2/3 Bases None Ability to explain and apply all system limits and precautions.

Question Source:

Bank #24485 Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

55.43.112 L8062120RO Describe two actions which must be taken outside the control room in order to use the SUFP as a backup to the EFW pumps.

L1169103RO Describe the precautions, limitations, and setpoints for OSIOOO. 1 1.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 WA #

001.GEN.2.1.22 Question # 91 Group #

2 Proposed Question:

Importance Rating 3.3 In accordance with OS1000.07, Approach to Criticality, when is Mode 2 declared?

A. When the reactor is declared critical.

B. When the second count-rate doubling occurs.

C. When the operators commence control bank withdrawal.

D. When the operators commence shutdown bank withdrawal.

Proposed Answer: A Explanation of answer: OS1000.07 defines Mode 2 declaration when the reactor is critical. As defined by TS definitions, Mode 2 is when Keff is greater than or equal to.99. This is vague and W h e r defined in the startup procedure to provide consistency and conciseness.

Explanation of distractors: All distractors are plausible since they are times or specific items which occur during the reactor startup. Additionally they are items related to the control rod drive system which is part of the WA.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Bank # 15682 Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

OS1000.07, Pg 6 Note None Ability to determine Mode of Operation.

55.43.1/2/6 L1162103RO Summarize the major steps of OS1000.07.

L8010103RO Define form memory the following terms as found in TSs: Operational Mode.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

2 Question # 92 Group ##

2 Proposed Question:

Importance Rating 3.5 WA #

01 5.A2.02 The following plant conditions exist:

Power Range channel N44 was removed from service and its associated bistables tripped by Instrument & Controls (I & C) in accordance with abnormal OS121 1.04, Power Range NI Instrument Failure.

Due to a seal problem, the crew has just performed a downpower to 47% and removed the D RCP from service.

Power Range channel N41 begins to drift and is currently reading 52%.

Which of the following should be subsequently performed by the crew as directed by the Unit Supervisor?

A. Verify reactor trip and enter E-0, Reactor Trip or Safety Injection.

B. Continue with the power reduction and notify I & C to check power range channel N4 1.

C. Perform calorimetric calculation to correct N41 within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> or be in HOT STANDBY within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

D. Declare power range channel N4 1 inoperable and within one hour make preparations to be in MODE 3 within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

Proposed Answer:

A Explanation of answer: 2 PFWIs are now above P-8, reactor should trip on low RCS flow ( I of 4) - verify reactor trip and go to E-0.

Explanation of distractors:

All distractors are incorrect because the reactor should have tripped.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

OS121 1.04, RPS Detailed System Text pg 35, TS Table 3.3-1 None Ability to predict the impacts of faulty or erratic operation of detectors or compensating components on the NIS and based on these predictions, use procedures to correct, control or mitigate the consequences.

Bank #2203712003 NRC # 126 55.43.11215 L8030114RO Given the number of operable channels associated with the Rx trip system interlocks, state whether or not it is less than the minimum number of channels required to be operable and if so the required action.

L8030112RO Given a copy of TS, locate applicable LCOs and list applicable action statements for stated NI channel failures.

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier ##

2 WA #

034.A2.01 Question # 93 Group ##

2 Importance Rating 4.4 Proposed Question:

According to Seabrooks Updated Final Safety Analysis (UFSAR), Chapter 15 Accident Analysis, which of the following choices results in the most limiting fuel handling accident and what actions would you as a Unit Supervisor take to mitigate the consequences of this event?

A.

B.

C.

D.

A dropped spent fuel assembly within an open containment 80 hours9.259259e-4 days <br />0.0222 hours <br />1.322751e-4 weeks <br />3.044e-5 months <br /> following reactor shutdown, perform actions of OS 12 15.06, Fuel Handling Accident.

A dropped new fuel assembly within the Fuel Storage Building 60 hours6.944444e-4 days <br />0.0167 hours <br />9.920635e-5 weeks <br />2.283e-5 months <br /> following reactor shutdown, perform actions of OS12 15.06, Fuel Handling Accident.

A dropped spent fuel assembly within an open containment 120 hours0.00139 days <br />0.0333 hours <br />1.984127e-4 weeks <br />4.566e-5 months <br /> following reactor shutdown, perform actions of OS 1252.02, Airborne High Radiation.

A dropped loaded Spent Fuel Cask within the Fuel Storage Building 80 hours9.259259e-4 days <br />0.0222 hours <br />1.322751e-4 weeks <br />3.044e-5 months <br /> following reactor shutdown, perform actions of OS1 252.02, Airborne High Radiation.

Proposed Answer:

A Explanation of answer: According to Chapter 15, section 15.7, the most limiting fuel handling accident is a dropped spent fuel assembly in an open containment 80 hours9.259259e-4 days <br />0.0222 hours <br />1.322751e-4 weeks <br />3.044e-5 months <br /> following shutdown which is the earliest time when spent fuel can be first moved from the reactor vessel. The correct mitigation strategy is OS1215.06, Fuel Handling Accident.

Explanation of distractors:

B - incorrect but plausible because it was also analyzed in the UFSAR. This accident is not the bounding accident and therefore less limiting. Impacts are less than that of a containment fuel assembly drop. Once again this is the correct procedure.

C - incorrect but plausible because it is the correct accident, however, with more hours since shutdown, it is less limiting. It is possible that entry conditions for this procedure could be met making it even more plausible.\\

D-incorrect but plausible because it is one of the analyzed accident in the UFASR. The consequences of this event have minimal impact.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

UFSAR Chapter 15.7 Fuel Handling Accidents None Ability to predict the impacts of a Dropped Fuel Element on the Fuel Handling System and based on those predictions, use correct procedures to control, correct, or mitigate the consequences of the Dropped Fuel Element.

Question Source:

New Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

55.43.1141517 L8060103RO Describe the radiological hazards associated with spent fuel or new fuel.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

3 WA #

GEN.2.1.12 Importance Rating 4.0 Question # 94 Group #

1 Proposed Question:

With the Plant at 100% power the following conditions exist:

The Emergency Diesel Generator (EDG) Monthly Surveillance was successfully performed 30 days ago for the "A" EDG.

Preparation is being made to perform the Monthly Surveillance for the "A" EDG.

Due to a fuel oil leak, the "B" EDG becomes inoperable. Engineering determines that the potential exists for this to be a common Mode failure with the "A" EDG. Engineering will be contacting the vendor, and estimates the common cause failure possibility will be resolved within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />.

Using the Technical Specifications provided, what action, if any, is required with regard to the "A" Emergency Diesel Generator?

A. Do not start the "A" EDG until the "B" EDG is OPERABLE.

B. Restore the "A" EDG to OPERABLE within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

C. Start the "A" EDG to satisfy LCO ACTION requirements. Load the "A" EDG to 5600 to 6100 kW for at least 60 minutes.

D. Start the "A" EDG as required by the LCO ACTION requirements. The "A" EDG does not need to be loaded onto the Emergency Bus.

-~

Proposed Answer:

C Explanation of answer: LCO ACTION 3.8.1.1.b action b applies. This requires Surveillance 4.8.1.1.1.a. to be performed, and 4.8.1.1.2a.5 which is to start the "A" EDG and load to between 5600 - 6100 KW.

Explanation of distractors:

A - incorrect but plausible, since the "A" EDG run would not be required if the common cause failure concern could be resolved within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

B - incorrect but plausible, since this action is required for two inoperable EDGs, and engineering has reported that the potential exists for a common Mode failure.

D-incorrect but plausible, since the "A" EDG is required to be started, however because it was determined to be a common Mode failure it must be loaded unto its respective bus to satisfy operability requirements of the TS.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Higher 10 CFR Part 55 Content:

55.43.2 Learning Objective:

L8020124RO Given a copy of TS apply the TS associated with the EDG system and describe their bases.

Technical Specification 3.8 Electrical Power Systems Pgs 1-4 TS-3.8 pages 1-4 Ability to apply technical specifications for a system.

3/4.8 ELECTRICAL POWER SYSTEMS 3/4.8.1 A.C. SOURCES OPE RAT IN G LIMITING CONDITION FOR OPERATION 3.8.1.1 As

a.
b.

a minimum, the following A.C. electrical power sources shall be OPERABLE:

Two physically independent circuits between the offsite transmission network and the onsite Class ?E Distribution System, and Two separate and independent diesel generators, each with:

I) A separate day fuel tank containing a minimum fuel volume fraction of 3/8 (600 gallons),

2)

A separate Fuel Storage System containing a minimum volume of 62,000 gallons of fuel,

3).

A separate fuel transfer pump,

4)

Lubricating oil storage containing a minimum total volume of 275 gallons of lubricating oil, and Capability to transfer lubricating oil from storage to the diesel generator unit.

5)

APPLICABILITY: MODES 1,2, 3, and 4.

ACT1 ON :

a.

With an offsite circuit of the above required A.C. electrical power sources inoperable, demonstrate the OPERABILITY of the remaining A.C. source by performing Specification 4.8.1.1.I

a. within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and at least once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> thereafter; restore at least two offsite circuits to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in I COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SEABROOK - UNIT I 3/4 8-1 Amendment No. 3.3 W 8 0

ELECTRICAL POWER SYSTEMS A.C. SOURCES OPERATING LIMITING CONDITION FOR OPERATION 1

3.8.1. I (Continued)

ACTION:

b.

With a diesel generator inoperable, demonstrate the OPERABILITY of the remaining A.C. sources by performing Specification 4.8.1.I

.la within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Demonstrate the OPERABILITY of the remaining diesel generator by performing Specification 4.8.1.I.2a.5) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.* Restore at least two diesel generators to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

and at least once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> thereafter. Perform ACTION d.

I I

c.

With one offsite circuit and one diesel generator of the above required A.C.

electrical power sources inoperable, demonstrate the OPERABILITY of the remaining A.C: source by performing Specification 4.8.1.I

.la. within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and at least once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> thereafter. Perform ACTION d. Demonstrate the OPERABILITY of the remaining diesel generator by performing Specification 4.8.1.I

.2a.5) within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />." Restore at least one of the inoperable sources to OPERABLE status within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />. Restore at least two offsite circuits and two diesel generators to O f EMBLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> from the time of initial loss or I be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

I

  • The OPERABILITY of the remaining diesel generator need not be verified if it has been successfully operated within the last 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, or if currently operating, or if the diesel generator became inoperable due to:
1.

Preplanned preventive maintenance or testing,

2.

An inoperable support system with no potential common mode failure for the remaining diesel generator, or

3.

An independently testable component with no potential common mode failure for the remaining diesel generator.

SEABROOK - UNIT I 3/4 8-2 Amendment No. 33, 80

ELECTRICAL POWER SYSTEMS A.C. SOURCES OPE RAT IN G LIMITING CONDITION FOR OPERATION 3.8.1.l (Continued)

ACTION:

d.

With one diesel generator inoperable in addition to ACTION b. or c. above, verify that:

1.

All required systems, subsystems, trains, components, and devices that depend on the remaining OPERABLE diesel generator as a source of emergency power are also OPERABLE, and

2.

When in MODE 1, 2, or 3, the steam-driven emergency feedwater pump is OPERABLE.

If these conditions are not satisfied within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

L

e.

With two of the above required offsite A.C. circuits inoperable; restore at least one of the inoperable offsite sources to OPERABLE status within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />. With only one offsite source restored, restore at least two offsite circuits to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> from time of initial loss or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

I

f.

With two of the above required diesel generators inoperable, demonstrate the OPERABILITY of two offsite A.C. circuits by performing the requirements of Specification 4.8.1.1.la. within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and at least once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> thereafter; restore at least one of the inoperable diesel generators to OPERABLE status within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

Restore at least two diesel generators to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> from time of initial loss or be in least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SEABROOK - UNIT 1 L

3t4 8-2a Amendment No. %,80

ELECTRICAL POWER SYSTEMS A.C. SOURCES 0 PE RAT I N G SURVEILLANCE REQUIREMENTS 4.8.1.I.I transmission network and the Onsite Class I E Distribution,System shall be:

Each of the above required independent circuits between the offsite

a.

Determined OPERABLE at least once per 7 days by verifying correct breaker alignments, indicated power availability, and (manually and automatically) unit power supply from the normal circuit to the

b.

Demonstrated OPERABLE at least once per 18 months by transferring I

alternate circuit.*

I I

4.8.1.I

.2 Each diesel generator shall be demonstrated OPERABLE.*

a.

At least once per 31 days on a STAGGERED TEST BASIS by:

Verifying the fuel level in the day fuel tank:

Verifying the fuel level in the fuel storage tank; Verifying the fuel transfer pump starts and transfers fuel from the storage system to the day tank:

Verifying the lubricating oil inventory in storage:

Verifying the diesel starts from standby conditions and attains a steady-state generator voltage and frequency of 41 60 f 420 volts and 60 f 1.2 Hz.***

  • This surveillance requirement shall not be performed in Mode 1 or 2.
    • All planned starts for the purpose of these surveillances may be preceded by an engine I prelube period.
      • Performance of Specification 4.8.1.I

.2a.6) must immediately follow this surveillance.

Additionally, a modified start involving idling and gradual acceleration to synchronous speed may be used for this surveillance. When modified start procedures are not used, the time, voltage, and frequency tolerances of Specification 4.8.1.I

.2e must be met.

SEABROOK - UNIT 1 314 8-3 Amendment No. la, 38, M,80

ELECTRICAL POWER SYSTEMS A.C. SOURCES 0 P E RAT I N G SURVEILLANCE REQUIREMENTS 4.8.1.I

.2 (Continued)

6)

Verifying the generator is synchronized, gradually loaded-*

to greater than or equal to 5600 kW and less than or equal to 6100 kW, and operates within this load band for at least 60 minutes, and until stable engine operating temperature is attained; and

7)

Verifying the diesel generator is aligned to provide standby power to the associated emergency busses.

b.

At least once per 31 days by checking for and removing accumulated I

water from the day fuel tank;

c.

At least once per 31 days by checking for and removing accumulated water from the fuel oil storage tanks:

d.

By verifying fuel oil properties of new and stored fuel oil are tested in accordance with, and maintained within the limits of, the Diesel Fuel Oil Testing Program; At least once every 184 days' by verifying the diesel starts from standby condition and achieves:

e.
1)

A generator voltage and frequency greater than or equal to 3740 volts and 58.8 Hz within 10 seconds after the start signal, and

2)

A steady-state generator voltage and frequency of 41 60 f 420 volts and 60 f 1.2 Hz.

Diesel generator loading may be in accordance with manufacturers recommendations, including a warmup period. Momentary transients outside the load range, due to changing bus conditions, do not invalidate the test. In addition, this surveillance shall be preceded by and immediately follow without shutdown a successful performance of Specification 4.8.1.I.2a.5) or 4.8.1.I.2e.

  1. Performance of Specification 4.8.1. I.2a.6) must immediately follow this surveillance.

Additionally, Performance of Specification 4.8.1.I.2e satisfies Specification 4.8.1 - 1.2a.5).

\\

SEABROOK - UNIT 1 314 8-4 Amendment No. 4-3, 73, 80

ES-401

~

~

~

Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level Tier ##

Question # 95 Group #

KIA #

RO SRO 3

1 GEN.2.1.25 Importance Rating 3.1 Proposed Question:

Given the following plant conditions:

0 0

The plant has been shutdown for 10 days.

Reactor Coolant System (RCS) temperature is 120 F.

RCS water level is at the (-) 73.5inch elevation with nozzle dams installed.

The crew has just experienced a loss of the running Residual Heat Removal (RHR) pump and has entered OS 12 13.02, Loss of RHR While Operating at Reduced Inventory or Mid-Loop Conditions.

A representative from Reliability and Safety Engineering is not available.

Based on these conditions and using the attached reference material, determine the MINIMUM time to boiling?

A. 10 minutes B. 13 minutes C. 17 minutes D. 22 minutes Proposed Answer:

C Explanation of answer: Two Figures are provided. The correct figure OS12 13.02-4 versus 5 must be used. 10 days is 240 hours0.00278 days <br />0.0667 hours <br />3.968254e-4 weeks <br />9.132e-5 months <br /> at an initial RCS temperature of 120 F. the closest answer is about 17 minutes.

Explanation of distractors:

The other times chosen are based on common errors which could occur, such as in choice D which would be plausible if the incorrect figure is referenced or choice B if they mistakenly used 120 hours0.00139 days <br />0.0333 hours <br />1.984127e-4 weeks <br />4.566e-5 months <br /> vs. degrees.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

contain performance data.

Question Source:

Bank Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

Figure 081213.02-04/02-05, Time to Boiling vs. Time after Shutdown for RCS water level at Midloop Figure OS 12 13.02-04/02-05 Ability to obtain and interpret station reference materials such as graphs, monographs, and tables, which 55.43.5/6 L1705105RO Summarize major actions ofOS1213.02.

Number Title OS1213.02 LOSS OF RHR WHILE OPERATING AT REDUCED INVENTORY OR MID-LOOP CONDITIONS FIGURE OS1213.02 - 4 TIME TO BOILING vs. TIME AFTER SHUTDOWN FOR RCS WATER LEVEL AT MIDLOOP (below minus 71 inches)

Rev.lDate 08 CHG 03 0711 2/04 CAUTION 0

The best estimate of time to boil is provided by Reliability and Safety.

Engineering. The graph below provides conservative time to boil values and should only be used if no other information is available.

For planning purposes, the RCS time to boil should be based on the assumption of atmospheric pressure even when the RCS is evacuated.

NOTE The temperatures (e.g. IOOOF, 12OoF, 140°F etc.) for different curves refer to initial RCS temperature at the time that loss of RHR cooling occurs. All curves assume atmospheric pressure at the onset of boiling.

20 i 20 220 320 420 520 620 720 TIME AFTER SHUTDOWN (HOURS 1 41 of44

Number Title OS1213.02 LOSS OF RHR WHILE OPERATING AT REDUCED FIGURE OS1213.02 - 5 TIME TO BOILING vs. TIME AFTER SHUTDOWN FOR RCS WATER LEVEL AT MIDLOOP (below minus 36 inches)

CAUTlON 0

The best estimate of time to boil is provided by Reliability and Safety Engineering. The graph below provides conservative time to boil values and should only be used if no other information is available.

For planning purposes, the RCS time to boil should be based on the assumption of atmospheric pressure even when the RCS is evacuated.

The temperatures (e.g. IOOOF, 120°F, 140°F etc.) for different curves refer to initial RCS temperature at the time that loss of RHR cooling occurs. All curves assume atmospheric pressure at the onset of boiling.

NOTE Rev./Date 08 CHG 03 45 40 35 30 25 In

&I k- -

I W -

5

=!

b 20 Y

F 10 m

15 5

0 1 I I

I I

1 l

320 420 520 620 720 20 120 2 20 T I ME AFTER SHUTDOWN ( HOURS 1 100012-1 42 of 44

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

3 L

Question # 96 Group #

2 KIA #

GEN.2.2.22 Importance Rating 4.1 Proposed Question:

Which of the following statements describe the required actions in accordance with Seabrook Technical Specifications if Reactor Coolant System (RCS) pressure reaches 2785 psig while in Mode 2?

A. Restore compliance and be in Mode 3 within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. Notify NRC within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. Notify the Site Vice-president and NSARC within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

B. Reduce RCS pressure to below safety limit within 5 minutes. Notify NRC withm 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. Notify the Site Vice-President and NSARC within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

C. Restore compliance and be in Mode 3 within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. Notify the NRC as soon as possible. Submit a safety limit violation report to NSARC within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.

D. Reduce RCS pressure to below safety limit withm 5 minutes. Notify the NRC as soon as possible. Submit a safety limit violation report to NSARC within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.

Proposed Answer:

A Explanation of answer: If the RCS safety limit is exceeded TS requires compliance restored and be in Mode 3 within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. Additionally under the admin section of TS (6.6), it is required to notify the NRC within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and also inform NSARC and the site VP within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

Explanation of distractors:

B - incorrect because although pressure should be promptly restored, the TS only specifies an hour to be in Mode 3 and restore compliance, however the other portions of the answer are plausible. In the bases of TS, if the plant is in Mode 3-5, then pressure must be restored within 5 minutes. The five minutes in these Modes is based on colder temperatures and brittle conditions.

C - incorrect because the notification times are incorrect, however the first part of the answer is plausible.

D - incorrect because of reasons previously stated and this does not contain any of the requirements of the TS.

L Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Modified Bank #16007 Original question attached to reference.

Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

TS 2.1.2 & 6.6 None Knowledge of limiting conditions for operations and safety limits.

55.43.1J2 L801 OI04RO State from memory the required actions if a safety limit is exceeded.

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

3 Question # 97 Group #

2 WA #

GEN.2.2.25 Importance Rating 3.7 Proposed Question:

Which of the following statements is the bases for Technical Specification 2.1.2, Reactor Coolant System (RCS)

Pressure Safety Limit?

A. To protect the integrity of the reactor fuel, which prevents the release of radionuclides contained in the fuel to the RCS.

B. To protect the integrity of the reactor fuel, which prevents the main steam safety valves and reactor protective system actuation from occurring.

C. To protect the integrity of the RCS piping and components, which prevents the release of radionuclides contained in the RCS to the containment atmosphere.

D. To protect the integrity of the RCS piping and components, which prevents the main steam safety valves and reactor protective system actuation from occurring.

Proposed Answer:

C Explanation of answer: Answer C is correct - 2.1.2 Basis Explanation of distractors:

B - incorrect because both the first part and second part of the answer are incorrect. The answer describes the other safety limit and states the incorrect reason.

A -incorrect because protecting the fuel is the other safety limit at Seabrook. The second part of the answer is plausible as it is the correct reason why we protect the RCS pressure boundary.

D - incorrect because the MSSVs and RPS are designed to prevent safety limits from being exceeded. The first part of the answer is plausible.

Technical Reference(s):

TS 2.1.2 bases Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

New Question Cognitive Level:

Lower 10 CFR Part 55 Content:

Learning Objective:

None Knowledge of the bases in technical specifications for limiting conditions for operations and safety limits.

55.43.2 L8010105RO List and describe two safety limits and the protection afforded by each.

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-401-5 Examination Outline Cross-reference:

Level RO SRO Tier #

3 Question # 98 Group #

3 WA #

GEN.2.3.10 Importance Rating 3.3 Proposed Question:

The following plant conditions exist:

0 A General Emergency has been declared.

The Wide Range Gas Monitor (WRGM) is in HIGH Alarm.

Upper wind direction indicates 45 degrees.

Offsite Dose Calculation determines PAR Group A is applicable only.

Based ONLY on these conditions and using the Emergency Response Manual (ER-l.2D/G), which one of the following is the correct action to guard against personnel exposure?

Schiller Station Activation State Recommendation A. REQUIRED Evacuate 2 mile radius and 5 miles downwind-Shelter all others B. NOT REQUIRED Evacuate 2 mile radius and 5 miles downwind-Shelter all others C. REQUIRED Evacuate 5 mile radius and 10 miles downwind-Shelter all others D. NOTREQUIRED Evacuate 5 mile radius and 10 miles downwind-Shelter all others Proposed Answer:

B Explanation of answer: Based on ER-1.2D and G, the required outcome of the given set of conditions results in Schiller Station not being activated and Sheltering and Evacuation occurring in the 2-5 mile radius towns only.

Explanation of distractors:

All combinations of distractors are incorrect however plausible since they contain some aspect of valid reponses that would apply given a different set of initial conditions.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Emergency Response Manual ER-1.2DlG ER-1.2D and ER-1.2G Ability to perform procedures to reduce excessive levels of radiation and guard against personnel exDosure.

Question Source:

New Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

55 A3.415 L1509115SR Given a copy of ER-1.2, determine PAR for a GE using PAR group A

& B.

GENERAL EMERGENCY CHECKLIST -

SHORT TERM EMERGENCY DIRECTOR CAUTION Per 10 CFR 50, Appendix E, IV.D, state notification shall be initiated within 15 minutes of the emergency declaration. Per 10 CFR 50.72, NRC notification shall be initiated within one (1) hour of the emergency declaration.

1.

[ ]

If Security reports that an assault on the protected area is imminent or in progress (a Code Red condition), proceed to step 5.

2.

[ 3 DETERMINE SCHILLER STATION ACTIVATION IS THERE A WRGM HIGH ALARM (RM-6528-4)?

IS THE UPPER WIND DIRECTION BETWEEN 80 AND 1 BO DEGREES?

L I

No IS THERE A MAIN STEAM LINE (MSL)

MONITOR HIGH ALARM WITH AN OPEN ASDVORSRVONTHEAFFECTED LINE?

OR ALARM WITH THE STEAM DRIVEN EFW PUMP RUNNING AND FED FROM THE IS THERE A MS~MONITOR HIGH YeS IS THE LOWER WIND DIRECTION BETWEEN 80 AND 180 DEGREES?

I SCHILLER STATION ACTIVATED SCHILLER STATION NOT ACTIVATED p:\\ap_whrisio\\er3.1 D.vsd r

CAUTION BEFORE DIRECTING A SITE EVACUATION, ENSURE THERE ARE NO SAFETY HAZGRDS WITHIN THE SITE BOUNDARY TO EVACUATING PERSONNEL. IF KNOWN RADIOLOGICAL OR OTHER HAZARDOUS CONDITIONS PRECLUDE EVACUATING PERSONNEL FROM USING EITHER THE NORTH ACCESS ROAD OR THE SOUTH ACCESS ROAD, NOTIFY THE SECURITY SHIFT SUPERVISOR.

I

3.

[ 3 NOTIFY STATION PERSONNEL (SCHILLER STATION NOT ACTIVATED)

a.
b.

Ensure Gaitronics night muting is off.

Sound the plant emergency alarm.

ER 1.2D Rev. 45 Page 1 of 9

GENERAL EMERGENCY CHECKLIST -

SHORT TERM EMERGENCY DIRkCTOR (Continued)

c.

Using the Gaitronics override, make the following announcement:

"ATTENTION ALL PERSONNEL. A GENERAL EMERGENCY HAS BEEN DECLARED. ALL PERSONNEL WITH GENERAL EMERGENCY DUTIES EVACUATE THE SITE TO YOUR HOME."

REPORT TO YOUR ASSIGNED LOCATIONS. ALL NON-ASSIGNED PERSONNEL

d.
e.
f.
g.

Proceed to Step 6.

Enter the time of the initial announcement Repeat the plant emergency alarm.

Using the Gaitronics override, repeat the announcement.

CAUTION BEFORE DIRECTING A SITE EVACUATION, ENSURE THERE ARE NO SAFETY HAZARDS WITHIN THE SITE BOUNDARY TO EVACUATING PERSONNEL. IF KNOWN RADIOLOGICAL OR OTHER HAZARDOUS CONDITIONS PRECLUDE EVACUATING PERSONNEL FROM USING EITHER THE NORTH ACCESS ROAD OR THE SOUTH ACCESS ROAD, NOTIFY THE SECURITY SHIFT SUPERVISOR

4.

[ 3 NOTIFY STATION PERSONNEL (SCHILLER STATION ACTIVATED)

a.
b.

Ensure Gaitronics night muting is off.

Sound the plant emergency alarm.

c.

Using the Gaitronics override, make the following announcement:

"ATTENTION ALL PERSONNEL, A GENERAL EMERGENCY HAS BEEN DECLARED. ALL PERSONNEL WITH GENERAL EMERGENCY DUTIES REPORT TO YOUR ASSIGNED LOCATIONS. ALL OTHER PERSONNEL EVACUATE THE SITE TO SCHILLER STATION."

d.

Enter the time of the initial announcement

e.

Repeat the plant emergency alarm.

f.

Using the Gaitronics override, repeat the announcement.

g.

Proceed to step 6.

ER 1.2D Rev. 45 Page 2 of 9

GENERAL EMERGENCY CHECKLIST -

SHORT TERM EMERGENCY DIRECTOR (Continued)

5.

[ 1 NOTIFY STATION PERSONNEL (INTRUDER ENTRY INTO PROTECTED AREA)

Ensure Gaitronics night muting is OR

a.
b.

Sound the spare alarm.

c.

Using the Gaitronics override, make the following announcement:

ATTENTION ALL PERSONNEL, A GENERAL EMERGENCY HAS BEEN DECLARED, CLEAR ALL HALLWAYS AND STOP ALL MOVEMENT UNTIL ADVISED OTHERWISE.

I

d.

Enter the time of the initial announcement

e.

Repeat the spare alarm.

f.

Using the Gaitronics override, repeat the announcement.

6.

[ ]

NOTIFY GUARD ISLAND SECURITY

a.
b.

Contact Guard Island Seciuity at x4006.

If Guard Island Security cannot be contacted and a security event is in progress, proceed to step f.

c.

Provide the following information:

A General Emergency has been declared

,The emergency initiating condition designation (e.g., C Red, 6a, 12b, etc.)

Schiller Station idis not being activated (as determined above)

Time of declaration

d.

Direct implementation of procedure GN1332.00, Security Response to a Declared Radiological Emergency.

e.

Proceed to step 7.

f.

Activate ERO pagers (GUARD ISLAND SECURITY CANNOT BE CONTACTED/SECURlTY EVENT IN PROGRESS)

(1)

Using commercial telephone, dial 9-771-2400.

(2)

Listen for voice prompt, For ER use only, followed by 2 beeps.

ER 1.2D Rev. 45 Page 3 of 9

GENERAL EMERGENCY CHECKLIST -

SHORT TERM EMERGENCY DIRWTOR (Continued)

(3)

After the beeps, enter 22222.

(4)

Hangup.

(5)

If the call does not go through or no voice prompt is given, do the following:

(a)

Using commercial telephone, dial 9-508-522-8958.

(b)

Listen for voice prompt, For ER use only, followed by 2 beeps.

(c)

After the beeps, enter 22222.

(d)

Hangup.

7.

[ ]

COMPLETE FORM ER 2.OB, STATE NOTIFICATION FACT SHEET

a.

Block 1 - Leave blank

b.

Block 2 - Circle either declared or terminated, check General Emergency and enter either Time Declared or Time Terminated.

c.

Block 3 - Complete using the following information:

(1)

If a CSFST condition C Red or Z Red exist, or an already completed ODPS run indicates PAR Group By implement form ER 1.2G. If none of these indications exist, go to step (2).

(2)

If a release is in progress from the plant vent, enter the current upper wind direction - FROM degrees.

(3)

If a release from the plant vent is NOT in progress, enter the current lower wind direction - FROM degrees.

(4)

Identify the appropriate PAR GROUP A column based on the above wind direction to determine the towns to be evacuated and sheltered.

( 5 )

Check off the evacuated and sheltered towns and evacuated and closed beaches on form ER 2.OB, Block 3 ER 1.2D Rev. 45 Page 4 of 9

ERPA A

B -

C D

E F

G New H Massac -

GENERAL EMERGENCY CHECKLIST -

SHORT TERM EMERGENCY DIRECTOR (Continued) 1 1

TOWN Seabrook Hampton Falls Amesbury Salisbury Kensington South Hampton Hampton North Hampton Menimac Newburyport Newbury West Newbury Brentwood East Kingston Exeter Newfields Newton Kingston 1 Greenland Stratham Rye 1 New Castle Portsmouth mpshire Beaches usetts Beaches PAR CROUP A I

(El 303-33.9 Evacuate Evacuate Evacuate Evacuate Shelter Shelter Shelter Shelter Shelter Shelter Shelter Shelter Shelter Shelter Shelter Shelter Shelter Shelter I Shelter Shelter Shelter

~ Shelter Shelter Evacuate I Close -

uate 2 Mile Radius and 5 Miles Downwind-Shelter All Others) 281.5-100.9 122.9 167.9 281.4 302.9 Evacuate Evacuate Evacuate Shelter Shelter Evacuate Evacuate Evacuate Shelter Shelter Evacuate Evacuate Shelter Shelter I Shelter I Evacuate I Evacuate I Shelter Shelter I Shelter I Shelter 1 Shelter I Shelter Shelter Shelter Shelter Shelter Shelter Shelter Shelter n Shelter Shelter I Shelter Shelter Shelter Shelter Shelter Shelter Shelter Shelter Shelter Shelter Shelter Shelter Shelter Shelter Shelter Shelter Shelter Shelter Shelter Shelter 1 Shelter Shelter Shelter Shelter Shelter Shelter Shelter Shelter Shelter Shelter I Shelter I Shelter I Shelter I Shelter Shelter I Shelter I Shelter I Shelter I Shelter (6)

Check off Implement KI plans for the general public on form ER 2.OB, Block 3.

d.

Block 4 - Use the following guidance when completing this Block.

As used here, a release is defined as follows:

(NEXT PAGE)

ER I.2D Rev. 45 Page 5 of 9

GENERAL EMERGENCY CHECKLIST -

SHORT TERM EMERGENCY DIRECTOR (Continued)

Radioactive material is being released to the environment as indicated by 0

Wide Range Gas Monitor (WRGM) Alert or High Alarm (RM-65284 OR Main Steam Line Monitor Alert or High Alarm with an Open ASDV or Main Steam Line Safety Valve on the Affected Main Steam Line OR Main Steam Line Monitor Alert or High Alarm and the Steam Driven EFW Pump Operating and Fed from the Affected Line OR STED judgment that a radiological release has occurred and been terminated or is continuing

e.
f.
8.

[ I

a.
b.

C.

d.
e.

AND Block 5 - Self-explanatory Block 6 - Leave blank NOTIFY THE STATES Give the completed copy of form ER 2.OB to the Work Control Supervisor.

Direct the Work Control Supervisor to implement form ER 1.2E.

If the Work Control Supervisor is not available, implement form ER 1.2E.

Assign the Fire Brigade Leader as Control Room Communicator, and direct the Communicator to implement form ER 1.2F.

release of material is directly attributable to the event.

If notified that the ERO pagers failed to activate, direct the Control Room Communicator to notify a position holder for each Primary Responder position per form ER 1.2F.

I ER 1.2D Rev. 45 Page 6 of 9

GENERAL EMERGENCY CHECKLIST -

SHORT TERM EMERGENCY DIRECTOR (Continued)

I

9.

[ 3 FOLLOW-UP PAR ASSESSMENT

a.

Using form ER 1.2G, General Emergency PAR Worksheet, determine if upgraded protective action recommendations are warranted.

b.

Ifresults fiom the above assessment indicate a PAR Group B selection, complete a new form ER 2.OB and provide it to the Work Control Supervisor for transmittal.

10.

[ ]

COMPLETE FORM ER Z.OD, EVENT NOTIFICATION WORKSHEET If needed, detailed instructions are contained in procedure ER 2.0, Emergency Notification Documentation Forms Procedure.

1 1.

[ ]

ACTIVATE THE EMERGENCY RESPONSE DATA SYSTEM (ERDS)

a.

Select "Cancel" (this will return screen to main menu).

b.

C.

From the main menu screen, select "BOP."

From the BOP menu screen, select "EMERGENCY RESPONSE."

d.

From the Emergency Response menu screen, select "ERDS ACTIVATION."

e.

From the ERDS menu screen, select "ACTIVATE."

12.

[ I NOTIFYTHENRC

a.

Using form ER 2.OD, notify the NRC Headquarters Operations Officer on the FTS handset phone. If this phone is not operable, use a commercial line. The numbers below can be used for either phone.

1-(301) 816-5100 (primary) 1-(301) 951-0550 (backup)

b.

Ask the NRC Headquarters Operations Officer to verify that ERDS data is being satisfactorily received by the NRC. If not, use "Reconnect" to reactivate ERDS.

c.

Turn over NRC communications to the Control Room Communicator.

ER 1.2D Rev. 45 Page 7 of 9

GENERAL EMERGENCY CHECK@T -

SHORT TERM EMERGENCY DIWCTOR (Continued)

13.

[ ]

NHDPHS AND MDPH VERIFICATION CALLBACKS When representatives of the NH Office of Community and Public Health and/or the Massachusetts Department of Public Health call in, provide the following information, as requested:

14.

[ I

a.
b.

C.

d.
15.

[ I

a.
b.

C.

d.

Verification of the information contained on form ER 2.OB, State Notification Fact Sheet A brief description of events and prognosis.

EMERGENCY RECLASSIFICATION If an ODPS run is required and one has not yet been performed, initiate an ODPS run in accordance with procedure ER 5.7, Offsite Dose Projection System. An ODPS run is required for each of the following conditions:

A Wide Range Gas Monitor (WRGM) high alarm (RM-6528-4)

A Main Steam Line Monitor high alarm with an open ASDV or SRV on the A Main Steam Line Monitor high alarm with the steam driven EFW pump The results of effluent analysis or site boundary monitoring indicate a dose rate affected line running and fed from the affected line greater than or equal to 0.06 me&.

If there is a radiological release via the turbine-driven EFW pump exhaust, dispatch a monitoring team to the downwind site boundary location to obtain a site boundary dose rate and use the Unmonitored Release Path of ODPS.

Assess current emergency conditions and reclassifL in accordance with procedure ER 1.1, Classification of Emergencies.

If warranted, implement form ER 1.2A, ER 1.2B, or ER 1.2C as appropriate to the new classification.

RADIOLOGICAL RELEASE INITIATION OR TERMINATION If the radiological release status reported to the states on fonn ER 2.OB Block 4 changes such that a release has started or a previous release has terminated gncJ no further releases are expected, complete blocks 2 through 5 of a new form ER 2.OB.

Give the completed copy of form ER 2.OB to Work Control Supervisor.

Direct the Work Control Supervisor to implement form ER 1.2E.

If the Work Control Supervisor is not available, implement form ER 1.2E.

ER 1.2D Rev. 45 Page 8 of 9

GENERAL EMERGENCY CHECKLIST -

SHORT TERM EMERGENCY DIRECTOR (Continued)

16.

[ ]

PRIMARY RESPONDER BRIEFINGS As requested, brief Primary Responders on:

Station status, Accident mitigation and corrective actions taken, Status of the emergency response organization, Communications with offsite authorities, and Status of ERDS activation.

17.

[ 3 COMMAND AND CONTROL TURNOVER (Do not delegate)

a.

Turn over emergency command and control responsibilities to the Site Emergency Director.

b.

Provide all notification documentation.

C.

Enter the time of turnover:

d.

Announce turnover of command and control responsibilities in the Control Room.

18.

[ ]

EMERGENCY TERMINATION A General Emergency cannot be terminated by the STED except as discussed in Precaution 3.5.

The emergency shall be terminated by either the Site Emergency Director or the Response Manager.

ER 1.2D Rev. 45 Page 9 of 9

ES-40 1 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

3 Question # 99 Group #

4 KIA #

GEN.2.4.11 Importance Rating 3.6 Proposed Question:

The plant is operating at 75% power when the following alarms are received:

0 0

D4433 LTOP Train B ARMED D4434 LTOP Train A 100# FROM ACTUATION Which of the following is the proper abnormal operating procedure to enter in response to this condition?

A. OS1201.08, Tavg Delta T Instrument Failure due to RCS loop 2 narrow range Th failing low.

B. OS1247.01, Loss of a Vital Instrument Panel PP-lA, PP-lB, PP-IC, PP-1D due to loss ofpower to PP-1B.

C. OS1201.06, PT-455-458 PZR Pressure Instrument Failure due to pressurizer pressure channel P-456 failing high.

D. OS1201.09, RCS Wide Range Pressure or Temperature Instrument Failure, due to RCS loop 2 wide range Th failing low.

Proposed Answer:

D Explanation of answer: Auctioneered low Th is an input into the PORV control logic. OS1201.09 Attachment A provides a simplified diagram of this logic.

Explanation of distractors:

A - incorrect because RCS loop narrow range temperature channels do not feed PORV control logic.

B - incorrect because loss of PP-1B would result in the opposite train alarms.

C - incorrect because failure high of PZR pressure channel P-456 will not generate the stated conditions.

Technical Reference(s):

OS1201.09, Attachment A Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Bank Question Cognitive Level:

Higher 10 CFR Part 55 Content:

55.43.5 Learning Objective:

L1182107RO Recognize symptoms or entry conditions for OS1201.09.

L1182108RO Summarize major actions for OS1201.09.

None Knowledge of abnormal operating condition procedures.

ES-401 Seabrook Written Examination Question Worksheet Form ES-40 1-5 Examination Outline Cross-reference:

Level RO SRO Tier #

3 Question # 100 Group #

4 WA #

GEN.2.4.15 Importance Rating 3.5 Proposed Question:

The following conditions exist:

An Anticipated Transient Without Scram event occurs.

PRIOR to the Short Term Emergency Director (STED) evaluating the Emergency Plan, the crew locally trips the reactor.

The STED determines the plant was in a Site Area Emergency and determines that the Site Area Emergency condition has cleared and the plant is now in an Unusual Event.

Which of the following describes how the initial emergency plan notifications should be carried out?

A.

B.

C.

D.

Perform notifications at the Unusual Event level; during initial NRC notification inform them that a higher classification level had existed.

Perform notifications at the Site Area Emergency level; during initial NRC notifications inform them that the higher classification has cleared.

Perform notifications at the Unusual Event level; during follow-uD NRC notifications inform them that a higher classification level had existed.

Perform notifications at the Site Area Emergency level; during follow-up NRC notifications inform them that the higher classification cleared when the lower one clears.

Proposed Answer:

A Explanation of answer: According to the SSER, ER 1.1 states that if emergency related indications are received and reduced in severity such that the emergency classification went from an earlier higher to a current lower level, the lower level emergency should be declared, therefore the UE is the correct call above. Also this paragraph states that state and NRC notifications shall be made IAW ER 1.2. ER 1.2 states that if an emergency that was terminated or reclassified to a lower level prior to NRC notification, the initial notification shall include the fact that the higher emergency classification existed prior to initial notification.

Explanation of distractors:

B - incorrect because it is declared at a UE vs. SAE. The initial notification portion of the answer is plausible.

C - incorrect because it is on initial vs. follow-up notifications. The UE portion of the answer is plausible.

D - incorrect and not plausible but a consistent mix with the choices.

Technical Reference(s):

Proposed references to be provided to applicants during examination:

WA Topic:

Question Source:

Question Cognitive Level:

Higher 10 CFR Part 55 Content:

Learning Objective:

SSER ER-1.1 pg 4, ER 1.2, pg 4 None Knowledge of the communication procedures associated with EOP implementation.

Modified from 2003 NRC exam.

Original question attached to reference.

55.43.115 L1509111 SR Discuss the actions required if emergency related indications are received and reduced in severity, such that the emergency classification went from an earlier higher level to a current lower level.