Letter Sequence Other |
---|
|
Results
Other: ML033030017, ML033030030, ML033030041, ML033030046, ML033030053, ML033030058, ML033030061, ML033030065, ML033030070, ML033030079, ML033030097, ML033030158, ML033030185, ML033030359, ML033030415, ML033030423, ML033030434, ML033030459, ML033030488, ML033090383
|
MONTHYEARML0330300972003-11-24024 November 2003 G20030560/LTR-03-0646 - Martin Rennert Ltr Re Ucs/Riverkeeper 2.206 - Indian Point Project stage: Other ML0330300172003-11-24024 November 2003 G20030560/LTR-03-0629 - Paul Feiner Ltr Ucs/Riverkeeper 2.206 - Indian Point Project stage: Other ML0330300302003-11-24024 November 2003 G20030560/LTR-03-0631 - Lea Wood Ltr Ucs/Riverkeepers, Inc. 2.206 - Indian Point Project stage: Other ML0330300412003-11-24024 November 2003 G20030560/LTR-03-0633 - Stephen Nevin Ltr Ucs/Riverkeepers, Inc. 2.206 - Indian Point Project stage: Other ML0330300462003-11-24024 November 2003 G20030560/LTR-03-0634 - Barbara Carrellas Ltr. Ucs/Riverkeepers, Inc. 2.206 - Indian Point Project stage: Other ML0330300532003-11-24024 November 2003 G20030560/LTR-03-0635 - Laura Miner Ltr. Ucs/Riverkeepers, Inc. 2.206 - Indian Point Project stage: Other ML0330300582003-11-24024 November 2003 G20030560/LTR-03-0637 - Paul Harris Ltr. Ucs/Riverkeeper 2.206 - Indian Point Project stage: Other ML0330300612003-11-24024 November 2003 G20030560/LTR-03-0638 - Robert Lesko Ltr Re Ucs/Riverkeeper 2.206 - Indian Point Project stage: Other ML0330300702003-11-24024 November 2003 G20030560/LTR-03-0642 - James B. Richardson Ltr Re Ucs/Riverkeeper 2.206 - Indian Point Project stage: Other ML0330300792003-11-24024 November 2003 G20030560/LTR-03-0643 - Ron I. Wish Ltr Re Ucs/Riverkeeper 2.206 - Indian Point Project stage: Other ML0330304342003-11-24024 November 2003 G20030560/LTR-03-0641 - Lawrence E. Rozenfeld Ltr Re Ucs/Riverkeeper 2.206 - Indian Point Project stage: Other ML0330301582003-11-24024 November 2003 G20030560/LTR-03-0654 - Laurie N. Lehey, Et Al., Ltrs Re Ucs/Riverkeeper 2.206 - Indian Point Project stage: Other ML0330301852003-11-24024 November 2003 G20030560/LTR-03-0604, 0605, 0606, 0608, 0609 and 0610 Ltr Re Ucs/Riverkeeper 2.206 - Indian Point Project stage: Other ML0330303592003-11-24024 November 2003 G20030560/LTR-03-0645 - Elizabeth Bernsohn Ltr Re Ucs/Riverkeeper 2.206 - Indian Point Project stage: Other ML0330304152003-11-24024 November 2003 G20030560/LTR-03-0632 - Stan Goff Ltr Ucs/Riverkeepers, Inc. 2.206 - Indian Point Project stage: Other ML0330304232003-11-24024 November 2003 G20030560/LTR-03-0636 - Susan Black Ltr Ucs/Riverkeeper Inc., 2.206 - Indian Point Project stage: Other ML0330304592003-11-24024 November 2003 G20030560/LTR-03-0644 - Carol and Donald Gardner Ltr Ucs/Riverkeeper 2.206 - Indian Point Project stage: Other ML0330304882003-11-24024 November 2003 G20030560/LTR-03-0677 - Dennis Heller, Et Al., Ltr Re Ucs/Riverkeeper 2.206 - Indian Point Project stage: Other ML0330903832003-11-24024 November 2003 G20030560/LTR-03-0608 Ltr to Joan and Ronald Keaton Regarding Indian Point 2.206 Project stage: Other ML0330300652003-11-24024 November 2003 G20030560/LTR-03-0639 - Salvatore Rao Ltr Re Ucs/Riverkeeper 2.206 - Indian Point Project stage: Other 2003-11-24
[Table View] |
|
---|
Category:Letter
MONTHYEARML24011A1982024-01-12012 January 2024 ISFSI, Notice of Organization Change for Site Vice President ML23342A1082024-01-0909 January 2024 Independent Spent Fuel Storage Installation Security Inspection Plan ML23353A1742023-12-19019 December 2023 ISFSI, Emergency Plan, Revision 23-04 L-23-019, Proof of Financial Protection 10 CFR 140.152023-12-18018 December 2023 Proof of Financial Protection 10 CFR 140.15 ML23339A0442023-12-0505 December 2023 Issuance of Amendment No. 68, 301 and 277 Regarding Changes to Implement the Independent Spent Fuel Storage Installation Physical Security Plan ML23326A1322023-12-0505 December 2023 Issuance of Amendment No. 67, 300 & 276 to Implement the Independent Spent Fuel Storage Installation Only Emergency Plan ML23338A2262023-12-0404 December 2023 Signed Amendment No. 27 to Indemnity Agreement No. B-19 ML23356A0212023-12-0101 December 2023 American Nuclear Insurers, Secondary Financial Protection (SFP) Program ML23242A2772023-11-30030 November 2023 NRC Letter Issuance - IP LAR for Units 2 and 3 Renewed Facility Licenses and PDTS to Reflect Permanent Removal of Spent Fuel from SFPs ML23338A0482023-11-30030 November 2023 ISFSI, Report of Changes to Physical Security, Training and Qualification, Safeguards Contingency Plan, and ISFSI Security Program, Revision 28 ML22339A1572023-11-27027 November 2023 Letter - Indian Point - Ea/Fonsi Request for Exemptions from Certain Emergency Planning Requirements for 10 CFR 50.47 and 10 CFR Part 50, Appendix E IR 05000003/20230032023-11-21021 November 2023 NRC Inspection Report Nos. 05000003/2023003, 05000247/2023003, 05000286/2023003, and 07200051/2023003 ML23100A1172023-11-17017 November 2023 NRC Response - Indian Point Energy Center Generating Units 1, 2, and 3 Letter with Enclosures Regarding Changes to Remove the Cyber Security Plan License Condition ML23050A0032023-11-17017 November 2023 Letter - Issuance Indian Point Unit 2 License Amendment Request to Modify Tech Specs for Staffing Requirements Following Spent Fuel Transfer to Dry Storage ML23100A1252023-11-17017 November 2023 Letter and Enclosure 1 - Issuance Indian Point Energy Center Units 1, 2, and 3 Exemption for Offsite Primary and Secondary Liability Insurance Indemnity Agreement ML23100A1432023-11-16016 November 2023 Letter - Issuance Indian Point Energy Center Generating Units 1, 2, and 3 Exemption Concerning Onsite Property Damage Insurance (Docket Nos. 50-003, 50-247, 50-286) ML23064A0002023-11-13013 November 2023 NRC Issuance for Approval-Indian Point EC Units 1, 2 and 3 Emergency Plan and Emergency Action Level Scheme Amendments L-23-012, Master Decommissioning Trust Agreement Changes for Indian Point Nuclear Generating Units 1, 2 and 3, Pilgrim Nuclear Power Station, Palisades Nuclear Plant and the Non-Qualified Trust for Big Rock Point2023-11-13013 November 2023 Master Decommissioning Trust Agreement Changes for Indian Point Nuclear Generating Units 1, 2 and 3, Pilgrim Nuclear Power Station, Palisades Nuclear Plant and the Non-Qualified Trust for Big Rock Point ML23306A0992023-11-0202 November 2023 and Indian Point Energy Center, Notification of Changes in Schedule in Accordance with 10 CFR 50.82(a)(7) ML23063A1432023-11-0101 November 2023 Letter - Issuance Holtec Request for Indian Point Energy Center Generating Units 1, 2, and 3 Exemptions from Certain Emergency Planning Requirements of 10 CFR 50.47 and Part 50 ML23292A0262023-10-19019 October 2023 LTR-23-0211-RI Thomas Congdon, Executive Deputy, Department of Public Service, Chair, Indian Point Decommissioning Oversight Board, Letter Independent Spent Fuel Storage Installation Inspection and Office of the Inspector General Report-RI ML23289A1582023-10-16016 October 2023 Decommissioning International - Registration of Spent Fuel Casks and Notification of Permanent Removal of All Indian Point Unit 3 Spent Fuel Assemblies from the Spent Fuel Pit ML23270A0082023-09-27027 September 2023 Registration of Spent Fuel Casks ML23237A5712023-09-22022 September 2023 09-22-2023 Letter to Dwaine Perry, Chief, Ramapo Munsee Nation, from Chair Hanson, Responds to Letter Regarding Opposition of the Release and Dumping of Radioactive Waste from Indian Point Nuclear Power Plant Into the Hudson River ML23242A2182023-09-12012 September 2023 IPEC NRC Response to the Town of New Windsor, Ny Board Certified Motion Letter Regarding Treated Water Release from IP Site (Dockets 50-003, 50-247, 50-286) ML23250A0812023-09-0707 September 2023 Registration of Spent Fuel Casks ML23255A0142023-08-31031 August 2023 LTR-23-0211 Thomas Congdon, Executive Deputy, Department of Public Service, Chair, Indian Point Decommissioning Oversight Board, Letter Independent Spent Fuel Storage Installation Inspection and Office of the Inspector General Report IR 05000003/20230022023-08-22022 August 2023 NRC Inspection Report 05000003/2023002, 05000247/2023002, 05000286/2023002, and 07200051/2023002 ML23227A1852023-08-15015 August 2023 Request for a Revised Approval Date Regarding the Indian Point Energy Center Permanently Defueled Emergency Plan and Emergency Action Level Scheme ML23222A1442023-08-10010 August 2023 Registration of Spent Fuel Casks ML23208A1642023-07-26026 July 2023 Village of Croton-on-Hudson New York Letter Dated 7-26-23 Re Holtec Wastewater ML23200A0422023-07-19019 July 2023 Registration of Spent Fuel Casks ML23235A0602023-07-17017 July 2023 LTR-23-0194 Dwaine Perry, Chief, Ramapo Munsee Nation, Ltr Opposition of the Release and Dumping of Radioactive Waste from Indian Point Nuclear Power Plant Into the Hudson River ML23194A0442023-07-11011 July 2023 Clarification for Indian Point Energy Center License Amendment Request, Independent Spent Fuel Storage Installation Physical Security Plan ML23192A1002023-07-11011 July 2023 Response to Request for Additional Information Regarding License Amendment Request to Revise the Emergency Plan and Emergency Action Level Scheme ML23171B0432023-06-23023 June 2023 Letter - Indian Point Energy Center - Request for Additional Information for Independent Spent Fuel Storage Installation Facility-Only Emergency Plan License Amendment ML23118A0972023-06-0606 June 2023 06-06-23 Letter to the Honorable Michael V. Lawler, Et Al., from Chair Hanson Regarding Holtec'S Announcement to Expedite Plans to Release Over 500,000 Gallons of Radioactive Wastewater from Indian Point Energy Center Into the Hudson River ML23144A3512023-05-25025 May 2023 Clementina Bartolotta of Pearl River, New York Email Against Treated Water Release from Indian Point Site ML23144A3522023-05-25025 May 2023 Loredana Bidmead of New York E-Mail Against Treated Water Release from Indian Point Site ML23144A3412023-05-25025 May 2023 Dianne Schirripa of Rockland County, New York Email Against Treated Water Release from Indian Point Site ML23144A3472023-05-25025 May 2023 David Mart of Blauvelt, New York Email Against Treated Water Release from Indian Point Site ML23144A3402023-05-25025 May 2023 Melvin Israel of New York Email Against Treated Water Release from Indian Point Site ML23144A3542023-05-25025 May 2023 Terri Thal of New City, New York Email Against Treated Water Release from Indian Point Site ML23144A3532023-05-25025 May 2023 John Shaw of New York Email Against Treated Water Release from Indian Point Site 2024-01-09
[Table view] |
Text
November 24, 2003 Mr. Lawrence Ethan Rozenfeld 31 Ross Ave.
Spring Valley, NY 10977
Dear Mr. Rozenfeld:
On behalf of the Nuclear Regulatory Commission (NRC), I am responding to your letter of September 15, 2003, to Chairman Diaz urging the NRC to order the immediate shutdown of Indian Point Nuclear Generating Unit Nos. 2 and 3 (IP2 and 3) as requested in a petition filed on September 8, 2003, by the Union of Concerned Scientists and Riverkeeper, Inc. The petitioners requested that the NRC take this action because of a concern with the potential for blockage of the containment sumps at IP2 and 3 during an accident.
After thorough consideration of the issues raised in the petition, the NRC denied the request for the immediate shutdown of IP2 and 3 in a letter dated October 22, 2003. The NRC has been addressing this concern with all licensees of pressurized-water reactors and concluded that continued operation of the plants does not pose an undue risk to public health and safety while the issue is being resolved generically.
On June 9, 2003, the NRC issued a bulletin informing licensees of the results of an NRC-sponsored study that identified the potential susceptibility of recirculation sump screens to debris blockage in the event of an accident. The NRC was evaluating whether piping insulation and other materials dislodged by a steam or water jet emerging from a postulated break in the reactor coolant piping would be transported and accumulate in the sump and subsequently impede the operation of the emergency core cooling pumps. During certain postulated accidents scenarios, water is taken from the sump and recirculated back to the reactor vessel after the supply of water from the large-volume storage tanks is exhausted. An NRC-approved methodology for evaluating each plants susceptibility to debris clogging is being developed to ensure that each evaluation is based on state-of-the-art, plant-specific information and to provide the NRC with the technical basis for ensuring that any proposed solution adequately addresses the issue. While the evaluations are being done, many plants, including IP2 and 3 have taken steps to minimize the potential risk associated with this issue. It is also important to recognize that the probability of an accident that would require recirculation from the sump is very unlikely.
The petitioners had based their request on a generic NRC-sponsored study that does not provide sufficient basis and level of detail for drawing conclusions about the operation of sumps at individual plants. The purpose of that study was to determine if the issue needed further evaluation and whether plant-specific reviews were warranted. There are also limitations in the study that make it inappropriate to apply the study data to individual plants such as IP2 and 3.
In particular for IP2 and 3, the NRC took exception with the petitioners statement that failure of the sump during an accident is ?almost certain. The study used plant data that is at least 5-7
L. Rozenfeld years old, and the data was not verified for accuracy. Many plants, including IP2 and 3, have made significant changes so that plant characteristics modeled in the study do not reflect current plant configurations. For example, at IP2 and 3, the amount of calcium silicate insulation (a major contributor to sump blockage) was greatly reduced when the steam generators were replaced. Further, the study did not recognize that IP2 and 3 each have two independent and redundant sumps that are located in different parts of the containment. The containment sump is a completely independent backup sump that can be used if the normal recirculation sump loses suction due to debris clogging of its sump screen.
I hope that you find this information useful in understanding the NRCs actions on this generic issue and the implications for IP2 and 3. Although having denied their request for immediate action to shut down the facility, we are continuing to evaluate the petition. We will complete our review and respond to the petitioners in a Directors Decision in accordance with our review process in the near future. A copy of the October 22 NRC letter (Accession No. ML032930295) can be accessed electronically from the Agencywide Documents Access and Management System (ADAMS) Public Electronic Reading Room on the Internet at the NRC Web site, http://www.nrc.gov/reading-rm/adams.html. Persons who do not have access to ADAMS or who encounter problems in accessing the documents located in ADAMS, should contact the NRC PDR Reference staff by telephone at 1-800-397-4209 or 301-415-4737, or by e-mail to pdr@nrc.gov.
Sincerely,
/RA/
James W. Clifford, Acting Director Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation
L. Rozenfeld years old, and the data was not verified for accuracy. Many plants, including IP2 and 3, have made significant changes so that plant characteristics modeled in the study do not reflect current plant configurations. For example, at IP2 and 3, the amount of calcium silicate insulation (a major contributor to sump blockage) was greatly reduced when the steam generators were replaced. Further, the study did not recognize that IP2 and 3 each have two independent and redundant sumps that are located in different parts of the containment. The containment sump is a completely independent backup sump that can be used if the normal recirculation sump loses suction due to debris clogging of its sump screen.
I hope that you find this information useful in understanding the NRCs actions on this generic issue and the implications for IP2 and 3. Although having denied their request for immediate action to shut down the facility, we are continuing to evaluate the petition. We will complete our review and respond to the petitioners in a Directors Decision in accordance with our review process in the near future. A copy of the October 22 NRC letter (Accession No. ML032930295) can be accessed electronically from the Agencywide Documents Access and Management System (ADAMS) Public Electronic Reading Room on the Internet at the NRC Web site, http://www.nrc.gov/reading-rm/adams.html. Persons who do not have access to ADAMS or who encounter problems in accessing the documents located in ADAMS, should contact the NRC PDR Reference staff by telephone at 1-800-397-4209 or 301-415-4737, or by e-mail to pdr@nrc.gov.
Sincerely,
/RA/
James W. Clifford, Acting Director Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation DISTRIBUTION:
EDO Reading File K. Cyr P. Milano K. Johnson W. Travers H. Miller, RI J. Goldberg SECY C. Paperiello J. Dyer D. Skay (Ltr-03-0641)
S. Collins B. Sheron B. Benney NRR Mailroom W. Kane T. Marsh S. Little (GT20030560)
P. Norry J. Clifford D. Lew, R-I OGC W. Dean R. Laufer T. Walker, R-I OPA S. Burns S. Weerakkody L. Cox OCA ADAMS Accession Numbers: Package: ML033030036 , Incoming: ML032760260, Response: ML033030434 OFFICE PDI-1/PM PDI-1/LA PDI-1/SC PDI-1 NAME PMilano SLittle PMilano for RLaufer JClifford DATE 11/24/03 11/24/03 11/24/03 11/24/03 OFFICIAL RECORD COPY