FENOC Perry Nuclear Power Plant 10 Center Road FirstEnergy Nuclear Operating Company Perry Ohio 44081 William R. Kanda 440-280-5579 Vice President - Nuclear Fax: 440-280-8029 May 20, 2003 PY-CEI/NRR-2709L United States Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555 Perry Nuclear Power Plant Docket No. 50-440 Submission of Core Operating Limits Report Ladies and Gentlemen:
Enclosed is a copy of the Cycle 10 Core Operating Limits Report (COLR) for Perry Nuclear Power Plant (PNPP), Unit 1. The COLR is submitted in accordance with Technical Specification 5.6.5, "Core Operating Limits Report."
If you have questions or require additional information, please contact Mr. Vernon K. Higaki, Manager - Regulatory Affairs, at (440) 280-5294.
Very truly yours, Enclosure cc: NRC Project Manager NRC Resident Inspector NRC Region III D I
_. r PDB-FOO01 Page: i Rev.: 10 PERRY OPERATIONS MANUAL Plant Data Book Entry TITLE: CORE OPERATING LIMITS REPORT FOR THE PERRY NUCLEAR POWER PLANT UNIT 1 CYCLE 10 (RELOAD 9)
PDB - F0001 /Rev. 10 MPL: Jll EFFECTIVE DATE: 5-21-03
SUMMARY
OF LAST CHANGE: This incorporates the core thermal limits for Cycle 10.
Rev. 9 - Added clarification for Single Loop Operation. Added Pressure Regulator Out Of Service limits. Added power, flow and exposure dependent Linear Heat Generation Rate limits rather than using constant values.
Rev. 10 - The Y-axis label on Figure 3.2.1-2 of the Perry Unit 1 Cycle 10 COLR is being corrected to read MAPFACP . Figure 3.2.1-2 is the Power Dependent MAPLHGR Factor (MAPFACp), Fuel Types GE12 and GE14.
REFERENCES:
Technical Specification 5.6.5, 'Core Operating Limits Report" COMMITMENTS: None PREPARED BY: Mark Laris/John Pelcic 5-20-03 Date
PDB-FO001 Page: 1 Rev.: 10 UNIT 1 CORE OPERATING LIMITS REPORT INDEX Specification Page INTRODUCTION AND REFERENCES AVERAGE PLANAR LINEAR HEAT GENERATION RATE (CORRESPONDS TO TS 3.2.1)
Figure 3.2.1-1 Flow Dependent MAPLHGR Factor (MAPFACf),
Fuel Types GE12 and GE14 6 Figure 3.2.1-2 Power Dependent MAPLHGR Factor (MAPFACp),
Fuel Types GE12 and GE14 7 Figure 3.2.1-3 MAPLHGR Versus Average Planar Exposure, Fuel Type GE12 8 Figure 3.2.1-4 MAPLHGR Versus Average Planar Exposure, Fuel Type GE14 9 MINIMUM CRITICAL POWER RATIO (CORRESPONDS TO TS 3.2.2)
Figure 3.2.2-1 Power Dependent MCPR Limit (MCPRp),
Fuel Type GE12 and GE14 (Two Loop Operation) 11 Figure 3.2.2-2 Flow Dependent MCPR Limit (MCPRf),
Fuel Type GE12 and GE14 (Two Loop Operation) 12 Figure 3.2.2-3 Power Dependent MCPR Limit (MCPRp),
Fuel Type GE12 and GE14 (Single Loop Operation) 13 Figure 3.2.2-4 Flow Dependent MCPR Limit (MCPRf),
Fuel Type GE12 and GE14 (Single Loop Operation) 14 Figure 3.2.2-5 Power Dependent MCPR Limit (MCPRp)
Fuel Type GE12 and GE14 (Two Loop Operation)
Pressure Regulator Out Of Service 15 Figure 3.2.2-6 Power Dependent MCPR Limit (MCPRp),
Fuel Type GE12 and GE14 (Single Loop Operation)
Pressure Regulator Out Of Service 16 PERRY UNIT 1 CYCLE 10 CORE OPERATING LIMITS REPORT
PDB-FOOOI Page: 2 Rev.: 10 UNIT 1 CORE OPERATING LIMITS REPORT INDEX (Continued)
Specification Page LINEAR HEAT GENERATION RATE (CORRESPONDS TO TS 3.2.3)
Figure 3.2.3-1 LHGR Versus Average Planar Exposure, Fuel Type GE12 18 Figure 3.2.3-2 LHGR Versus Average Planar Exposure, Fuel Type GE14 19 REACTOR PROTECTION SYSTEM INSTRUMENTATION (CORRESPONDS TO TS 3.3.1.1)
Simulated Thermal Power Time Constant 20 OSCILLATION POWER RANGE MONITOR (OPRM) INSTRUMENTATION (CORRESPONDS TO TS 3.3.1.3) 21 PERRY UNIT CYCLE 10 CORE OPERATING LIMITS REPORT
PDB-FOO01 Page: 3 Rev.: 10 INTRODUCTION AND REFERENCES INTRODUCTION This Core Operating Limits Report for PNPP Unit 1 Cycle 10 is prepared in accordance with the requirements of PNPP Technical Specification Administrative Controls 5.6.5. The core operating limits presented were developed using NRC-approved methods (Reference 2). Results from the reload analysis for the General Electric fuel in PNPP Unit 1 for Cycle 10 are documented in References 3, 4 and 15.
The cycle-specific core operating limits for the following PNPP Unit 1 Technical Specifications are included in this report:
- 1. Average Planar Linear Heat Generation Rate (APLHGR) Limits for each fuel/lattice type, including the power and flow dependent MAPFAC curves with the single loop MAPLHGR reduction factor. (Technical Specification 3.2.1)
- 2. Minimum Critical Power Ratio Operating Limit including the power and flow dependent MCPR curves for Two Loop Operation and Single Loop Operation.
(Technical Specification 3.2.2) For Single Loop Operation the MCPR operating limits are increased by 0.01. (Reference 3)
Additional power dependent MCPR curves for Two Loop Operation and Single Loop Operation are provided for operation with one pressure regulator out of service.
- 3. Linear Heat Generation Rate (LHGR) Limits for each fuel/lattice type, including the power and flow dependent MAPFAC curves. (Technical Specification 3.2.3)
- 4. The simulated thermal power time constant. (Technical Specification 3.3.1.1, SR 3.3.1.1.14)
- 5. Oscillation Power Range Monitor (OPRM) Instrumentation. (Technical Specification 3.3.1.3)
REFERENCES
- 1. Perry Nuclear Power Plant Updated Safety Analysis Report, Unit 1, Appendix 15B-Reload Safety Analysis.
- 2. 'General Electric Standard Application for Reactor Fuel-GESTAR II",
NEDE-24011-P-A-14 and NEDE-24011-P-A-14-US (US Supplement), June 2000.
- 3. "Supplemental Reload Licensing Report for Perry Nuclear Power Plant Unit 1 Reload 9 Cycle 10", GNF Document 0000-0004-4479SRLR, Rev 1, April 2003 PERRY UNIT 1 CYCLE 10 CORE OPERATING LIMITS REPORT
PDB-F001 Page: 4 Rev.: 10
- 4. "Fuel Bundle Information Report for Perry Nuclear Power Plant Unit 1 Reload 9 Cycle 10", GNF Document 0000-0004-4479FBIR, Rev 0, December 2002
- 5. License Amendment No. 61 to Facility Operating License NPF - 58, June 2, 1994.
- 6. Generic Letter 88-16, "REMOVAL OF CYCLE-SPECIFIC PARAMETERS FROM TECHNICAL SPECIFICATIONS'
- 7. Technical Specification 3.2.1, Average Planar Linear Heat Generation Rate
- 8. Technical Specification 3.2.2, Minimum Critical Power Ratio
- 9. Technical Specification 3.2.3, Linear Heat Generation Rate
- 10. Technical Specification 3.3.1.1, Reactor Protection System Instrumentation
- 11. Technical Specification 5.6.5, Core Operating Limits Report
- 12. Technical Specification 2.1.1.2, Safety Limit MCPR
- 13. License Amendment No. 33 to Facility Operating License NPF - 58, September 13, 1990.
- 14. License Amendment 112 to Facility Operating License NPF-58, June 1, 2000.
- 15. "Supplemental Reload Licensing Report for Perry Nuclear Power Plant Unit 1 Reload 8 Cycle 9", GNF Document Jll-03754SRLR, Rev 1, January 2003
PERRY UNIT 1 CYCLE 10 CORE OPERATING LIMITS REPORT
PDB-FOO01 Page: 5 Rev.: 10 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (TS 3.2.1)
All AVERAGE PLANAR LINEAR HEAT GENERATION RATES (APLHGRs) shall not exceed the result obtained from multiplying the applicable MAPLHGR values* by the smaller of either the flow dependent MAPLHGR factor (MAPFACf) Figure 3.2.1-1 or the power dependent MAPLHGR factor (MAPFACp) Figure 3.2.1-2.
The following table lists the MAPLHGR limits as a function of exposure for GE14 fuel:
Exposure (GWD/st) ECCS MAPLHGR Limit (KW/FT) 0.00 12.82 14.51 12.82 19.13 12.82 57.61 8.00 63.50 5.00 The following table lists the MAPLHGR limits as a function of exposure for GE12 fuel:
Exposure (GWD/st) ECCS MAPLHGR Limit (KW/FT) 0.00 10.90 13.24 10.90 21.61 10.90 63.50 6.39 NOTE: The Single Loop Operation limits take effect when reset for single loop operation per LCO 3.4.1,"Recirculation Loops Operating". This is consistent with note (b)" to Table 3.3.1.1-1 of the Technical Specifications.
- These applicable MAPLHGR values are:
- 1. Those for the respective fuel as a function of the average planar exposure (as described by the NRC approved methodology described in GESTAR-II) or,
- 2. When hand calculations are required, the MAPLHGR limit as a function of the average planar exposure as shown in Figures 3.2.1-3 (GE12) and Figure 3.2.1-4 (GE14) for the applicable type of fuel.
PERRY UNIT 1 CYCLE 10 CORE OPERATING LIMITS REPORT
PDB-FOO0l Page: 6 Rev.: 10 Flow Dependent MAPLHGR Factor (MAPFACf), Fuel Types GEl2 and GEl4 1.1 1.0 0.9
'I-
^ 0.8
'I 0.7 0.6 0.5 20 40 60 80 100 120 CORE FLOW (% RATED)
Figure 3.2.1-1 PERRY UNIT 1 CYCLE 10 CORE OPERATING LIMITS REPORT
PDB-FOO01 Page: 7 Rev.: 10 Power Dependent MAPLHGR Factor (MAPFACp), Fuel Types GE12 and GE14 1.1 1.0 0.9 C,
0.
0.7 0.6 0.5 0 20 40 60 s0 100 CORE THERMAL POWER (% RATED)
Figure 3.2.1-2 PERRY UNIT 1 CYCLE 10 CORE OPERATING LIMITS REPORT
PDB-FOO0l Page: 8 Rev.: 10 MAPLHGR Versus Average Planar Exposure, Fuel Type GE12 12 10 8
E
-J 6 w
4 2
-GE12ECCS MAPLHGR Limit MAPLHGR =10.9 for Exposures </= 21.61 MAPLHGR = 10.9 + (-0.10766)*(Exposure - 21.61) for 21.61< Exposures <I= 63.5 0 . . . . . . . . . . . . . . . .. .. ... ... ...
. -. ..I .
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Average Planar Exposure (GWDIST)
NOTE: 1. Intermediate MAPLHGR values are obtained by linear interpolation between adjacent points.
Figure 3.2.1-3 PERRY UNIT 1 CYCLE 10 CORE OPERATING LIMITS REPORT
PDB-FO001 Page: 9 Rev.: 10 MAPLHGR Versus Average Planar Exposure, Fuel Type GE14 14 12 10 U.
_ 8, a.
<86 C) \
4 L_*-GE14 ECCS MAPLHGR Limit]
MAPLHGR = 12.82 for Exposures </= 19.13 MAPLHGR = 12.82 + (-0.12526)*(Exposure - 19.13) for 19.13 < Exposures <= 57.61 MAPLHGR = 8.0 + (-0.50934)*(Exposure - 57.61) for 57.61 < Exposures </= 63.5 2
c . . . . . . . . . . . . . . . . .. . . . . . . .
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Average Planar Exposure (GWDIST)
NOTE: 1. Intermediate MAPLHGR values are obtained by linear interpolation between adjacent points.
Figure 3.2.1-4 PERRY UNIT 1 CYCLE 10 CORE OPERATING LIMITS REPORT
PDB-FOO01 Page: 10 Rev.: 10 MINIMUM CRITICAL POWER RATIO (TS 3.2.2)
The MINIMUM CRITICAL POWER RATIO (MCPR) shall be equal to or greater than the higher of the MCPRf and MCPRp limits at the indicated core flow and THERMAL POWER as specified in Figures 3.2.2-1 and 3.2.2-2 for Two Loop Operation and Figures 3.2.2-3 and 3.2.2-4 for Single Loop Operation.
The MCPR Safety Limit for Cycle 10 is 1.10. The MCPR Safety Limit for Single Loop Operation is 1.11 <TECHNICAL SPECIFICATIONS 2.1.1.2>. During Single Loop Operation, the Maximum Fraction of Limiting Critical Power Ratio (MFLCPR) shall be equal to or less than 0.99. Use FTI-B12 Single Loop Operation to implement this revised MFLCPR.
NOTE 1: For Cycle 10 no change to MCPR limits is required for planned reduction of feedwater temperature to as low as 325.5 0F. Final feedwater temperature may be reduced to 255.5 0F after all control rods are withdrawn at the end of cycle.
NOTE 2: Planned reduction of rated feedwater temperature from nominal rated feedwater temperature is not permitted during plant operation with the reactor recirculation system in Single Loop Operation.
NOTE 3: Figures 3.2.2-1 and 3.2.2-2 depict the limiting fuel type for Two Loop Operation. Figures 3.2.2-3 and 3.2.2-4 depict the limiting fuel type for Single Loop operation. Specific values are found in References 3 and 15.
Figures 3.2.2-5 and 3.2.2-6 depict power dependent MCPR curves for Two Loop Operation and Single Loop Operation are provided for operation with one pressure regulator out of service. This may be implemented as either a change to the core monitoring software or appropriate administrative limit.
NOTE 4: There are a total of 19 safety/relief valves, the two lowest setpoint valves are assumed to be out-of-service in the transient analysis.
NOTE 5: The MCPR operating limit is increased 0.01 to account for the increase in the single loop MCPR safety limit with the reactor recirculation system in Single Loop Operation.
NOTE 6: The Single Loop Operation limits take effect when reset for Single Loop Operation per LCO 3.4.1,"Recirculation Loops Operating". This is consistent with note (b)" to Table 3.3.1.1-1 of the Technical Specifications.
PERRY UNIT 1 CYCLE 10 CORE OPERATING LIMITS REPORT
PDB-FOO01 Page: 11 Rev.: 10 Power Dependent MCPR Limit (MCPRp),
Fuel Type GE12 and GE14 (Two Loop Operation)*
2 2.3 2.2 ____ _ MCPRp = [2.02 +0.0246(38 - P)]
\For 23.8% P 38%; Core Flow > 50%
<=
2.1 ForMCPRp =[1.99 + 0.0162(38 -)
23.8%= P 38%; Core Flow-50%
0 a
- 0. lPERMISSIBLEl 0L 1.9 . REGION OF.
0.
0
-j 0
t 8 !i ~~~~~~~OPERATION 0.
0 (3
MCPRp = 1.36 ^ 11.223 +0.004(66.7 - Pf)]
For 38% < P <=66.7%; All Core Flows 1.5\
I~ A IA MCPRgl = 1.36 *([1+0.005 100 - P)]
t3 0
20
__I I___ 40 1cP= 100%; All Core Flows 60 80 100 CORE THERMAL POWER (% RATED)
- Refer to NOTE 3 on Page 10 Figure 3.2.2-1 PERRY UNIT 1 CYCLE 10 CORE OPERATING LIMITS REPORT
PDB-FOOOI Page: 12 Rev.: 10 Flow Dependent MCPR Limit (MCPRf),
Fuel Type GE12 and GE14 (Two Loop Operation)*
1.8 1.7 p 1.6 cU a.
C 0
a.
0 a
-J 1.6 IA 1.3 1.2 0 20 40 60 so 100 120 CORE FLOW (% RATED)
- Refer to NOTE 3 on Page 10 Figure 3.2.2-2 PERRY UNIT 1 CYCLE 10 CORE OPERATING LIMITS REPORT
PDB-F0001 Page: 13 Rev.: 10 Power Dependent MCPR Limit (MCPRp),
Fuel Type GEl2 and GE14 (Single Loop Operation)*
2.5 2.4 2.2~~~ MCPRp = [2.02 + 0.0246(38 - P)] + 0.01
\ ~~~For 23.8% c= p c= 38%; Core Flow> 50%
2.2-MCPRp = .99 + 0.0162(38 - P)+ +0.01 2.1 \\ _ For 23.8% <z P<= 38%; Core Flow<= 50%
0 e 2.0-c0.
0 0
C REGION OFa 0m1B OPERATION.
1e*_MCPRp =(1.36 0.01) ' 1.223 + 0.004(66.7 - P)-
For 38% < P<=66.7%; All Cof D Flows
.2 MCPRp = (1.36+0.01)' 11 +0.005(1 00 -P) \
1.4 Feor 66.7% < P <=100 4; All Core Flows 1.3 0 20 40 60 80 1W0 CORE THERMAL POWER (% RATED)
- Refer to NOTE 3 and NOTE 5 on Page 10 Figure 3.2.2-3 PERRY UNIT 1 CYCLE 10 CORE OPERATING LIMITS REPORT
PDB-FOO01 Page: 14 Rev.: 10 Flow Dependent MCPR Limit (MCPRf),
Fuel Type GE12 and GE14 (Single Loop Operation)*
1.8 1.7
\ ~~~~~PEIRMISSIBLE REGION OF
. IF OPERATION E1.6 CD 0
0m1.5 0.
0.
0~ .
tY C
CL MCPRf*MAX [(1.36+0.01),
1.4 ((1.8134-0.006948F)*(1.1Ill .07))I For GE12 and GE14 Fuel E121GE14 OLMCPR 1.38 + 0.
1.3 1.2 0 20 40
_~~~~~- 60 Bo 100 120 CORE FLOW (% RATED)
- Refer to NOTE 3 and NOTE 5 on Page 10 Figure 3.2.2-4 PERRY UNIT 1 CYCLE 10 CORE OPERATING LIMITS REPORT
PDB-F0001 Page: 15 Rev.: 10 Power Dependent MCPR Limit (MCPRp),
Fuel Type GE12 and GE14 (Two Loop Operation)*
Pressure Regulator Out Of Service 2.5 2.4 2.3 2.2 a 2.1 0
0 X 2.0
.2 2
0 1.9 11 tL 0
0 o 1.5
-j 0
I-t,1.7 a .0 1.5 1.4 1.3 1.2 20 40 60 s0 100 CORE THERMAL POWER (% RATED)
- Refer to NOTE 3 on Page 10 Figure 3.2.2-5 PERRY UNIT 1 CYCLE 10 CORE OPERATING LIMITS REPORT
PDB-FOO0l Page: 16 Rev.: 10 Power Dependent MCPR Limit (MCPRp),
Fuel Type GEl2 and GEl4 (Single Loop Operation)*
Pressure Regulator Out Of Service 2.6 2.4 MCPRp = 12.02 + 0.0246 * (38 P)l + 0.01 2.3 For 23.8% <= P < 38%; Core Flow> 60%
2.2 2.1 0
0 0x PEMSSIBLE
- 2.0 0
MCPRp [1.99 +0.0162 (38 - P)j + 0.01 _
1 For 23.8% <z P<= 38%; Core Flow<= 50%
0 0 t.8 0.
0 CL 0
MCPRp = (1.36 + 0.01) 11.180 + 0.008(80.00 - P)J For 38% < P<=80%; All Core Flows 1.6 15 U)1.7 ====>~~~~~~~~=,0 el MCR= (1.36 + 0.01) * [1 + 0.005(100 - P)]
For 80% < P <=100%; All Core Flows 0 20 40 60 80 100 CORE THERMAL POWER (% RATED)
- Refer to NOTE 3 and NOTE 5 on Page 10 Figure 3.2.2-6 PERRY UNIT CYCLE 10 CORE OPERATING LIMITS REPORT
PDB-FOO01 Page: 17 Rev.: 10 LINEAR HEAT GENERATION RATE (TS 3.2.3)
All LINEAR HEAT GENERATION RATES (LHGRs) shall not exceed the result obtained from multiplying the applicable LHGR values* by the smaller of either the flow dependent MAPLHGR factor (MAPFACf) Figure 3.2.1-1 or the power dependent MAPLHGR factor (MAPFACp) Figure 3.2.1-2.
NOTE: The SLO MAPFACp and MAPFACf clamps are not applicable to LHGR.
- These applicable LHGR values are:
- 1. Those for the respective fuel type and Gadolinium content as a function of the average planar exposure (as described by the NRC approved methodology described in GESTAR-II) or,
- 2. When hand calculations are required, the LHGR as a function of the average planar exposure shown in Figures 3.2.3-1 (GE12) and Figure 3.2.3-2 (GE14) for the applicable type of fuel.
PERRY UNIT 1 CYCLE 10 CORE OPERATING LIMITS REPORT
PDB-FOOOl Page: 18 Rev.: 10 LHGR Versus Average Planar Exposure, Fuel Type GEl2 14 12 10 I 8 E
0 6
-J
- U02 LHGR Limit I UO21Gd LHGR Limit 4
U02 LHGR Limit LHGR =11.8 for Exposures <1= 13.24 LHGR = 11.8 + (-0.10764)*(Exposure -13.24) for 13.24 < Exposures </= 63.5 2
UO2/Gd LHGR Limit LHGR = 11.13 for Exposures </= 11.62 LHGR = 11.13 + (-0.097918)*(Exposure - 11.62) for 11.62 < Exposures </= 63.5 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Peak Pellet Exposure (GWDIST)
NOTE: 1. Intermediate LHGR values are obtained by linear interpolation between adjacent points.
Figure 3.2.3-1 PERRY UNIT 1 CYCLE 10 CORE OPERATING LIMITS REPORT
PDB-FOOO1 Page: 19 Rev.: 10 LHGR Versus Average Planar Exposure, Fuel Type GE14 16 14 12 10 i
IL 8
-J
-J 6
l-U02 LHGR Limit Li\
l 1,U021Gd LHGR Umitl 4
U02 LHGRLIit LHGR 13.4 for Exposures </I 14.51 LHGR '13.4 +(-0.12529)'(Exposure -14.51) for 14.51 <Exposures </ 57.61 LHGR 8.0 +(-0.50934)'(Exposure - 57.61) for 57.61 < Exposures </= 63.5 2
U02IGd LHGR Limit LHGR 11.75 for Exposures VJ=12.08 LHGR=11.76+(-0.11251)'(Exposure -12.08) for 12.08< Exposures <1 54.21 LHGR = 7.02 +(-0.45581)'(Exposure -54.21) for 54.21 < Exposures <1 59.98 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Peak Pellet Exposure (GWDIST)
NOTE: 1. Intermediate LHGR values are obtained by linear interpolation between adjacent points.
Figure 3.2.3-2 PERRY UNIT 1 CYCLE 10 CORE OPERATING LIMITS REPORT
PDB-FOOOI Page: 20 Rev.: 10 REACTOR PROTECTION SYSTEM INSTRUMENTATION (TS 3.3.1.1)
The simulated thermal power time constant shall be 6+/-0.6 seconds.
PERRY UNIT 1 CYCLE 10 CORE OPERATING LIMITS REPORT
PDB-FOOOI Page: 21 - LAST Rev.: 10 OSCILLATION POWER RANGE MONITOR (OPRM) INSTRUMENTATION (TS 3.3.1.3)
This page was not updated for Cycle 10 Operations. The OPRM's are inoperable due to the setpoint methodology issues identified in CR 01-2582.
Current Settings:
- 1. Confirmation Count Setpoint (Np = N2 ): 12
- 2. Amplitude Setpoint (Sp): 1.09
Reference:
Calculation: FM12, Revision 0 PERRY UNIT 1 CYCLE 10 CORE OPERATING LIMITS REPORT