ML071360092

From kanterella
Jump to navigation Jump to search
Submittal of Core Operating Limits Report, Revision 15
ML071360092
Person / Time
Site: Perry FirstEnergy icon.png
Issue date: 05/09/2007
From: Pearce L
FirstEnergy Nuclear Operating Co
To:
Document Control Desk, NRC/NRR/ADRO
References
PY-CEI/NRR-3032L PDB-F0001, Rev 15
Download: ML071360092 (23)


Text

FENOC Perry Nuclear Power Station 10 Center Road FirstEnergy Nuclear Operating Company Perry, Ohio 44081 L. William Pearce 440-280-5382 Vice President Fax: 440-280-8029 May 9, 2007 PY-CEI/NRR-3032L United States Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555 Perry Nuclear Power Plant Docket No. 50-440 Submission of Core Operating Limits Report Ladies and Gentlemen:

Enclosed is a copy of the Perry Nuclear Power Plant (PNPP) Core Operating Limits Report (COLR), Revision 15. The COLR is submitted in accordance with Technical Specification 5.6.5, "Core Operating Limits Report."

COLR, Revision 13 which documented a mid-cycle revision to the PNPP Operating Cycle 11 was submitted to the NRC by letter dated August 28, 2006 (PY-CEI/NRR-2987L). PNPP Operating Cycle 12, the upcoming operating cycle, was documented into COLR, Revision

14. Prior to the start of Operating Cycle 12, it was noted that COLR, Revision 14 contained minor editorial errors. COLR, Revision 15 which supersedes Revision 14, reflects the Operating Cycle 12 information and corrects the editorial errors.

If you have questions or require additional information, please contact Mr. Henry L. Hegrat, Supervisor - FirstEnergy Nuclear Operating Company Fleet Licensing at (330) 374-3114.

Very t~r yyour Enclosure cc:

NRC Project Manager NRC Resident Inspector NRC Region III

PDB-FOO01 Page:

i Rev.:

15 PERRY OPERATIONS MANUAL Plant Data Book Entry TITLE: CORE OPERATING LIMITS REPORT FOR THE PERRY NUCLEAR POWER PLANT UNIT 1 CYCLE 12 (RELOAD 11)

PDB -

F0001 /Rev.

15 MPL:

Jill EFFECTIVE DATE:

5-7-07

SUMMARY

OF LAST CHANGE:

Procedure Correction -

correct typographical errors.

REFERENCES:

Technical Specification 5.6.5, "Core Operating Limits Report" COMMITMENTS: None PREPARED BY:

Charles S.

Oroqvany 5-3-07 Date

PDB-FOO01 Page:

1 Rev.:

15 UNIT 1 CORE OPERATING LIMITS REPORT INDEX Specification Page INTRODUCTION AND REFERENCES AVERAGE PLANAR LINEAR HEAT GENERATION RATE (TS 3.2.1)

Figure 3.2.1-1 Figure 3.2.1-2 Figure 3.2.1-3 Flow Dependent MAPLHGR Factor (MAPFACf),

Fuel Type GE14 Power Dependent MAPLHGR Factor (MAPFACP),

Fuel Type GE14 MAPLHGR Versus Average Planar Exposure, Fuel Type GE14 31 51 6!

7 8

91 MINIMUM CRITICAL POWER RATIO (TS 3.2.2)

Figure 3.2.2-1 Figure 3.2.2-2 Figure 3.2.2-3 Figure 3.2.2-4 Figure 3.2.2-5 Figure 3.2.2-6 Power Dependent MCPR Limit (MCPRP),

Fuel Type GE14 (Two Loop Operation)

Flow Dependent MCPR Limit (MCPRf),

Fuel Type GEl4 (Two Loop Operation)

Power Dependent MCPR Limit (MCPRP),

Fuel Type GE14 (Single Loop Operation)

Flow Dependent MCPR Limit (MCPRf),

Fuel Type GE14 (Single Loop Operation)

Power Dependent MCPR Limit (MCPRp),

Fuel Type GEl4 (Two Loop Operation)

Pressure Regulator Out Of Service Power Dependent MCPR Limit (MCPRP),

Fuel Type GE14 (Single Loop Operation)

Pressure Regulator Out Of Service 11 12 13 14 15 16 PERRY UNIT I CYCLE 12 CORE OPERATING LIMITS REPORT

PDB-F0001 Page:

2 Rev.:

15 UNIT 1 CORE OPERATING LIMITS REPORT INDEX (Continued)

Specification Figure 3.2.2-7 Page Maximum Fraction Limiting Critical Power Ratio Limit (MFLCPR),

Fuel Type GET4 With One Pressure Regulator Out Of Service LINEAR HEAT GENERATION RATE (TS 3.2.3)

Figure 3.2.3-1 LHGR Versus Average Planar Exposure, Fuel Type GE14 REACTOR PROTECTION SYSTEM INSTRUMENTATION (TS 3.3.1.1)

Simulated Thermal Power Time Constant OSCILLATION POWER RANGE MONITOR (OPRM)

INSTRUMENTATION (TS 3.3.1.3) 17 18 19 20 21 PERRY UNIT 1 CYCLE 12 CORE OPERATING LIMITS REPORT

PDB-FOO01 Page:

3 Rev.:

15 INTRODUCTION AND REFERENCES INTRODUCTION This Core Operating Limits Report for PNPP Unit 1 Cycle 12 is prepared in accordance with the requirements of PNPP Technical Specification Administrative Controls 5.6.5.

The core operating limits presented were developed using NRC-approved methods (Reference 2).

Results from the reload analysis for the General Electric fuel in PNPP Unit 1 for Cycle 12 are documented in References 3, 4 and 15.

The cycle-specific core operating limits for the following PNPP Unit 1 Technical Specifications are included in this report:

1.

Average Planar Linear Heat Generation Rate (APLHGR) Limits for each fuel/lattice type, including the power and flow dependent MAPFAC curves with the single loop MAPLHGR reduction factor.

(Technical Specification 3.2.1)

2.

Minimum Critical Power Ratio Operating Limit including the power and flow dependent MCPR curves for Two Loop Operation and Single Loop Operation.

(Technical Specification 3.2.2)

Additional power dependent MCPR curves for Two Loop Operation and Single Loop Operation are provided for operation with one pressure regulator out of service.

3.

Linear Heat Generation Rate (LHGR)

Limits for each fuel/lattice type, including the power and flow dependent MAPFAC curves with the single loop MAPLHGR reduction factor.

(Technical Specification 3.2.3)

4.

The simulated thermal power time constant.

(Technical Specification 3.3.1.1, SR 3.3.1.1.14)

5.

Oscillation Power Range Monitor (OPRM)

Instrumentation.

(Technical Specification 3.3.1.3)

REFERENCES

1.

Perry Nuclear Power Plant Updated Safety Analysis Report, Unit 1, Appendix 15B-Reload Safety Analysis.

2.

"General Electric Standard Application for Reactor Fuel-GESTAR II",

NEDE-24011-P-A-15 and NEDE-24011-P-A-15-US (US Supplement),

September 2005.

3.

"Supplemental Reload Licensing Report for Perry Nuclear Power Plant Unit 1 Reload 11 Cycle 12",

GNF Document 0000-0052-0343SRLR, Rev 0, December 2006.

PERRY UNIT 1 CYCLE 12 CORE OPERATING LIMITS REPORT

PDB-FOO01 Page:

4 Rev.:

15

4.

"Fuel Bundle Information Report for Perry Nuclear Power Plant Unit 1 Reload 11 Cycle 12",

GNF Document 0000-0052-0343FBIR, Rev 0, December 2006.

5.

License Amendment No.

61 to Facility Operating License NPF -

58, June 2, 1994.

6.

Generic Letter 88-16, "REMOVAL OF CYCLE-SPECIFIC PARAMETERS FROM TECHNICAL SPECIFICATIONS".

7.

Technical Specification 3.2.1, Average Planar Linear Heat Generation Rate.

8.

Technical Specification 3.2.2, Minimum Critical Power Ratio.

9.

Technical Specification 3.2.3, Linear Heat Generation Rate.

10. Technical Specification 3.3.1.1, Reactor Protection System Instrumentation.
11. Technical Specification 5.6.5, Core Operating Limits Report.
12. Technical Specification 2.1.1.2, Safety Limit MCPR.
13.

License Amendment No.

33 to Facility Operating License NPF -

58, September 13, 1990.

14.

License Amendment 112 to Facility Operating License NPF-58, June 1, 2000.

15.

"Supplemental Reload Licensing Report for Perry Nuclear Power Plant Unit 1 Reload 8 Cycle 9",

GNF Document JII-03754SRLR, Rev 1, January 2003.

16.

CR 03-01377, "Equation for OL MCPR(P) in the Core Operating Limits Report is Suspect."

17.

License Amendment 132, Perry Nuclear Power Plant, Unit 1 - Issuance of Amendment RE: Revision of the Minimum Critical Power Ratio Safety Limit (TAC No.

MC 2599),

February 3, 2005.

18.

License Amendment 134, Perry Nuclear Power Plant, Unit 1 - Issuance of Amendment RE: Single Recirculation Loop Operation (TAC No.

MC 4224),

March 31, 2005.

19.

Calculation FM-012, OPRM Device Settings and Setpoints, Revision 3.

PERRY UNIT 1 CYCLE 12 CORE OPERATING LIMITS REPORT

PDB-FOO01 Page:

5 Rev.:

15 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (TS 3.2.1)

All AVERAGE PLANAR LINEAR HEAT GENERATION RATES (APLHGRs) shall not exceed the result obtained from multiplying the applicable MAPLHGR limits* by the smaller of either the flow dependent MAPLHGR factor (MAPFACf)

Figure 3.2.1-1 or the power dependent MAPLHGR factor (MAPFACp)

Figure 3.2.1-2.

The following table lists the MAPLHGR limits as a function of exposure for GEl4 fuel:

Exposure (GWD/st)

ECCS MAPLHGR Limit (KW/FT) 0.00 12.82 14.51 12.82 19.13 12.82 57.61 8.00 63.50 5.00 NOTE:

MAPLHGR Limits are defined in Reference 3.

MAPFACf and MAPFACp are defined in Reference 15.

NOTE:

The Single Loop Operation limits take effect when reset for single loop operation per LCO 3.4.1,"Recirculation Loops Operating".

This is consistent with note "(b)"

to Table 3.3.1.1-1 of the Technical Specifications.

Use FTI-B0012 Single Loop Operation to implement the revised MAPLHGR Limits.

These applicable MAPLHGR limits are:

1.

Those for the respective fuel as a function of the average planar exposure (as described by the NRC approved methodology described in GESTAR-II) or,

2.

When hand calculations are required, the MAPLHGR limit as a function of the average planar exposure as shown in Figures 3.2.1-3 (GEl4).

PERRY UNIT 1 CYCLE 12 CORE OPERATING LIMITS REPORT

PDB-FOQ01 Page:

6 Rev.:

15 Flow Dependent MAPLHGR Factor (MAPFACf),

Fuel Type GEl4 1.1 1.0 0.9 0

L 0.8 0.7 0.6 0.5 GE14 - Clamped at 0.80 During SLLJ MAPF~f--I14(.0,0.4574+0.0tJ6758F) 0 20 40 so 80 100 120 CORE: FLOW (% RATED)

Figure 3.2.1-1 PERRY UNIT 1

CYCLE 12 CORE OPERATING LIMITS REPORT

PDB-F0001 Page:

7 Rev.:

15 Power Dependent MAPLHGR Factor (MAPFACp),

Fuel Type GEl4 1.1 1.0¸ 0.9 UL. 0,8 0.

0;7 0.6 I

0.5 0

20 40 60 80 CORE THERMAL POWER (% RATED)

Figure 3.2.1-2 100 PERRY UNIT 1 CYCLE 12 CORE OPERATING LIMITS REPORT

PDB-FOO01 Page:

8 Rev.:

15 MAPLHGR Versus Averaqe Planar Exposure, Fuel Type GE14 14 12 10 R

U-E 0

I 0~

C,,

C.,

C.,

w 8

6

-0GE14 ECOS'MAPLHGR Limit MAPLHGR'= 12.82 fo~r Exposures </= 19.13 MAPLHGR =12.82 + (ýO. 12526)*(Exposure - 19.13):

for 19.13:< Exposures </= 57.61, MAPLHGR = 8.0 + (-0.'50934)*(Exposure - 57.61)'

fr 57.61 < Exposures </= 63.5

~

I-4 2

.0 0

5 1

15 20 25 30 35 40 45 50 55 Average Planar Exposure`(GWD/ST),:..

60 65 70 NOTE:

1.

Intermediate MAPLHGR values are obtained by linear interpolation between adjacent points.

Figure 3.2.1-3 PERRY UNIT 1 CYCLE 12 CORE OPERATING LIMITS REPORT

PDB-F0001 Page:

9 Rev.:

15 MINIMUM CRITICAL POWER RATIO (TS 3.2.2)

The MINIMUM CRITICAL POWER RATIO (MCPR) shall be equal to or greater than the higher of the MCPRf and MCPRP limits at the indicated core flow and THERMAL POWER as specified in Figures 3.2.2-1 and 3.2.2-2 for Two Loop Operation and Figures 3.2.2-3 and 3.2.2-4 for Single Loop Operation.

The MCPR Safety Limit for Cycle 12 is 1.08 and the MCPR Safety Limit for Single Loop Operation is 1.10 <TECHNICAL SPECIFICATIONS 2.1.1.2> (Reference 3 and 17).

During Single Loop Operation with 3D MONICORE monitor in "2

LOOPS ON" mode, the Maximum Fraction of Limiting Critical Power Ratio (MFLCPR) shall be equal to or less than 0.98.

Use FTI-B0012 Single Loop Operation to implement this revised MFLCPR.

NOTE 1:

For Cycle 12 no change to MCPR limits is required for planned reduction of feedwater temperature to as low as 325.5'F.

Final feedwater temperature may be reduced to 255.5°F after all control rods are withdrawn at the end of cycle if the OPRMs are OPERABLE.

NOTE 2:

Planned reduction of rated feedwater temperature from nominal rated feedwater temperature is not permitted during plant operation with the reactor recirculation system in Single Loop Operation, if the OPRMs are operable.

NOTE 3:

Figures 3.2.2-1 and 3.2.2-2 depict the limiting fuel type for Two Loop Operation.

Figures 3.2.2-3 and 3.2.2-4 depict the limiting fuel type for Single Loop operation.

Specific values are found in References 3 and 15.

Figures 3.2.2-5 and 3.2.2-6 depict power dependent MCPR curves for Two Loop Operation and Single Loop Operation for operation with one pressure regulator out of service.

This may be implemented as either a change to the core monitoring software or appropriate administrative limit.

Figure 3.2.2-7 depicts implementing an administrative limit to the Maximum Fraction Limiting Critical Power Ratio with One Pressure Regulator Out Of Service.

This is intended as an interim measure until such time that the 3D Monicore Data Bank can be updated to reflect the MCPRp(PROOS) curve.

Once the 3DM Data Bank is updated, the MFLCPR limit would return to 1.00.

Figure 3.2.2-7 represents the ratio of MCPRp to MCPRp(PROOS).

In the case where a Pressure Regulator is out of service and the plant is in Single Loop Operations, limit MFLCPR to the smaller of 0.98 and Figure 3.2.2-7, MFLCPR Limit With One Pressure Regulator Out Of Service.

PERRY UNIT 1 CYCLE 12 CORE OPERATING LIMITS REPORT

PDB-F0001 Page:

10 Rev.:

15 NOTE 4:

There are a total of 19 safety/relief valves, the two lowest setpoint valves are assumed to be out-of-service in the transient analysis.

NOTE 5:

The MCPR operating limit is increased 0.02 to account for the increase in the single loop MCPR safety limit with the reactor recirculation system in Single Loop Operation.

NOTE 6:

The Single Loop Operation limits take effect when reset for Single Loop Operation per LCO 3.4.1, "Recirculation Loops Operating".

This is consistent with note "(b)"

to Table 3.3.1.1-1 of the Technical Specifications.

NOTE 7:

The standard off-rated limits established as part of the GE14 new fuel introduction from Cycle 9 are applicable for the current Cycle 12 with the appropriate scaling.

The SLMCPR basis for MCPR(P) limits below Pbypass for GE14 is 1.10, and the MCPR(F) coefficients are based on a SLMCPR of 1.07.

Therefore, scaling of (1.08/1.10) was applied to the MCPR(P) graphs and scaling of (1.08/1.07) is applied to MCPR(F) coefficients to account for the changes in the SLMCPR (Reference 3).

PERRY UNIT 1 CYCLE 12 CORE OPERATING LIMITS REPORT

PDB-FOO01 Page:

11 Rev.:

15 Power Dependent MCPR Limit (MCPRp),

Fuel Type GE14 (Two Loop Operation)*

2.5 2.4 2.3 2.2 2.1 0,

2;0 C..

0 CL 1.9 00

-J 0

1.8 C-i.

CL 1.7 0

1.6 1.5 1.4 1.3 1.2 31 0

20 40 60 80 CORE THERMAL POWER (% RATED) 1o00

  • Refer to NOTE 3 on Page 9 Figure 3.2.2-1 PERRY UNIT 1 CYCLE 12 CORE OPERATING LIMITS REPORT

PDB-FOO01 Page:

12 Rev.:

15 Flow Dependent MCPR Limit (MCPRf),

Fuel Type GE14 (Two Loop Operation)*

1.8 1.7 0

1.6 1..

0.

0.

0.

0 1.5 1.4 1,2 0

20 40 60

-80 100 120 COREFLOW (% RATED)

  • Refer to NOTE 3 on Page 9 and Note 7 on Page 10 Figure 3.2.2-2 PERRY UNIT 1 CYCLE 12 CORE OPERATING LIMITS REPORT

PDB-FOO01 Page:

13 Rev.:

15 IPower Dependent MCPR Limit (MCPRp),

Fuel Tvpe GEl4 (Sinqle Loop Operation)*

qr 0

CL 0

C.

0 0.

0 0

CL I0 0.

0v C.

20 40 60 80 CORE THERMAL POWER (% RATED) 100

  • Refer to NOTE 3 and NOTE 5 on Page 9 Figure 3.2.2-3 PERRY UNIT 1 CYCLE 12 CORE OPERATING LIMITS REPORT

PDB-FOO01 Page:

14 Rev.:

15 Flow Dependent MCPR Limit (MCPRf),

Fuel Type GEl4 (Single Loop Operation)*

1.8 1.7 0

° 1.6 0

0 0.

01 a.

0 1.4 1.3 1,2 0

20 40 0-

80.

100 CORE FLOW (% RATED) 120 Refer to NOTE 3 and NOTE 5 on Page 9 and Note 7 on Page 10.

Figure 3.2.2-4 PERRY UNIT 1 CYCLE 12 CORE OPERATING LIMITS REPORT

PDB-FOO01 Page:

15 Rev.:

15 Power Dependent MCPR Limit (MCPRp),

Fuel Type GEl4 (Two Loop Operation)*

Pressure Regulator Out Of Service 2.5 2.4 2.3 2.2 F

2.1 0

0

,2.0 a

'U o 1.9 a.

0 C.

00 1.8

-j 0

I,-

1.7 a2.

0.

S1.6 1.5 1.4 1.3 1.2 0

20 40 80 so CORE THERMAL POWER. (% RATED)

'100.

  • Refer to NOTE 3 on Page 9 Figure 3.2.2-5 PERRY UNIT 1 CYCLE 12 CORE OPERATING LIMITS REPORT

PDB-FOO01 Page:

16 Rev.:

15 Power Dependent MCPR Limit (MCPRp),

Fuel Type GEl4 (Single Loop Operation)*

Pressure Requlator Out Of Service 2.5

  • 2.4 2.3 2.2 2.1 0

0 0,

-2.0 0

p r.L 1.9 0

0.00 01 O 1.7 a.

M,s1.6 1.5 1.4 1.3 1.2 0

20 40 60 80 100 CORE THERMAL POWER (% RATED)

  • Refer to NOTE 3 and NOTE 5 on Page 9 Figure 3.2.2-6 PERRY UNIT 1 CYCLE 12 CORE OPERATING LIMITS REPORT

PDB-F0001 Rev. :

15 Page:

17 Maximum Fraction Limiting Critical Power Ratio Limit (MFLCPR),

Fuel Type GEl4 With One Pressure Regulator Out Of Service MFLCPR Limit With One Pressure Regulator Out Of Service 1;010 1.0 05 1.000-0.995 0.985 0'.980 0.975 0.970 0.965 0 960 0 955 0.950 0.945 Unsafe Single Loop°

% RTP I perýaring Limit 38%

+

4

+

4

  • -+
4.

+

.4

+

4

+

4

.4 4

4 4

4

+

4-

+

+

4 U.

.0 V-

+

4

+<.

4 4

4 4

4 4

+

A

+

4 U.

0.

b 935 0.925 0.920 0.915 0.910 0.905 0.900 0.895 0.890 0.885 0.880 0.875 0.870 0.865 0.860 0.855 0.850 1.

1-.;00ý8ý0%RTPý 80% RTP

.10 66.7% RTP

-safe 20 25 30 35, 40 45 50 55 60 65 70 75 80 85 90 95 100

% Reactor Thermal Power

  • Refer to NOTE 3 and NOTE 5 on Page 9 Figure 3.2.2-7 PERRY UNIT 1 CYCLE 12 CORE OPERATING LIMITS REPORT

PDB-FOO01 Page:

18 Rev.:

15 LINEAR HEAT GENERATION RATE (TS 3.2.3)

All LINEAR HEAT GENERATION RATES (LHGRs) shall not exceed the result obtained from multiplying the applicable LHGR values* by the smaller of either the flow dependent MAPLHGR factor (MAPFACf)

Figure 3.2.1-1 or the power dependent MAPLHGR factor (MAPFACp)

Figure 3.2.1-2.

NOTE:

LHGR Limits are defined in Reference 4.

MAPFACf and MAPFACP are defined in Reference 15.

NOTE:

The Single Loop Operation limits take effect when reset for single loop operation per LCO 3.4.1,"Recirculation Loops Operating".

This is consistent with note "(b)"

to Table 3.3.1.1-1 of the Technical Specifications.

Use FTI-B0012 Single Loop Operation to implement the revised LHGR Limits.

These applicable LHGR values are:

1.

Those for the respective fuel type and Gadolinium content as a function of the average planar exposure (as described by the NRC approved methodology described in GESTAR-II) or,

2.

When hand calculations are required, the LHGR as a function of the average planar exposure shown in Figures 3.2.3-1 (GEl4).

PERRY UNIT 1

PDB-FOO01 Page:

19 Rev.:

15 LHGR Versus Averace Planar Exposure, Fuel Type GE14 16 14 12 10 E

LL

.-J 8

,*U02,LHGR Limit

-*UO2/Gd LHGR Limit U02 MHG6 Limit LHGR.= 13.4 for Exposures,</= 14.51.

LHGR = 13.4 + (-0.12529)(Exposure - 14.51) for 14.51 Exposures <J1=

57.61 LHGR = 8.0 + (-0.50934)*(Exposure. 7-57.61) -for 57.61< <Exposures </=. 63.5 UO2IGd LHGR Lrrimi LHGR,= 12.00 for Exposures <= 12.17 LHGR = 12.00 + (-0.1141029(Expasure -12.17) for 12.17 < Exposures <= 54.59 LHGR = 7.16 + (-0.462079)(Exposure -,54.59) for 54.596 < Exposures <1=3. 60.39 I

I.

i-1 L

I.

6 4

2 0

0 5

10 15 20 25 30 35 40" 45 50 55 Peak Pellet Exposure (GWDiST) 60 65 70 NOTE:

I.

Intermediate LHGR values are obtained by linear interpolation between adjacent points.

Figure 3.2.3-1 PERRY UNIT 1

PDB-FOO01 Page:

20 Rev.:

15 REACTOR PROTECTION SYSTEM INSTRUMENTATION (TS 3.3.1.1)

The simulated thermal power time constant shall be 6+/-0.6 seconds.

PERRY UNIT 1

PDB-FOO01 Page:

21 -

LAST Rev.:

15 OSCILLATION POWER RANGE MONITOR (OPRM)

INSTRUMENTATION (TS 3.3.1.3)

These are the Cycle 12 OPRM setpoints for operable OPRMs.

Current Settings:

1.

Confirmation Count Setpoint (Np

= N2 ) :

12

2.

Amplitude Setpoint (Sp):

1.10

Reference:

Calculation:

FM-012, Revision 3 PERRY UNIT 1 CYCLE 12 CORE OPERATING LIMITS REPORT