Failure to Follow Procedures When Working in High Radiation AreasML031250056 |
Person / Time |
---|
Site: |
Beaver Valley, Millstone, Hatch, Monticello, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Mcguire, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Kewaunee, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Oyster Creek, Watts Bar, Hope Creek, Grand Gulf, Cooper, Sequoyah, Byron, Pilgrim, Arkansas Nuclear, Three Mile Island, Braidwood, Susquehanna, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, Limerick, North Anna, Turkey Point, River Bend, Vermont Yankee, Crystal River, Haddam Neck, Ginna, Diablo Canyon, Callaway, Vogtle, Waterford, Duane Arnold, Farley, Robinson, Clinton, South Texas, San Onofre, Cook, Comanche Peak, Yankee Rowe, Maine Yankee, Quad Cities, Humboldt Bay, La Crosse, Big Rock Point, Rancho Seco, Zion, Midland, Bellefonte, Fort Calhoun, FitzPatrick, McGuire, LaSalle, 05000000, Zimmer, Fort Saint Vrain, Shoreham, Satsop, Trojan, Atlantic Nuclear Power Plant, Skagit, Marble Hill |
---|
Issue date: |
06/10/1986 |
---|
From: |
Jordan E NRC/IE |
---|
To: |
|
---|
References |
---|
IN-86-044, NUDOCS 8606040010 |
Download: ML031250056 (5) |
|
Similar Documents at Beaver Valley, Millstone, Hatch, Monticello, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Mcguire, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Kewaunee, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Oyster Creek, Watts Bar, Hope Creek, Grand Gulf, Cooper, Sequoyah, Byron, Pilgrim, Arkansas Nuclear, Three Mile Island, Braidwood, Susquehanna, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, Limerick, North Anna, Turkey Point, River Bend, Vermont Yankee, Crystal River, Haddam Neck, Ginna, Diablo Canyon, Callaway, Vogtle, Waterford, Duane Arnold, Farley, Robinson, Clinton, South Texas, San Onofre, Cook, Comanche Peak, Yankee Rowe, Maine Yankee, Quad Cities, Humboldt Bay, La Crosse, Big Rock Point, Rancho Seco, Zion, Midland, Bellefonte, Fort Calhoun, FitzPatrick, McGuire, LaSalle, 05000000, Zimmer, Fort Saint Vrain, Shoreham, Satsop, Trojan, Atlantic Nuclear Power Plant, Skagit, Marble Hill |
---|
Category:NRC Information Notice
MONTHYEARInformation Notice 2020-02, Flex Diesel Generator Operational Challenges2020-09-15015 September 2020 Flex Diesel Generator Operational Challenges ML20225A0322020-09-0303 September 2020 NRC Choice Letter to NAC International with Attached Safety Inspection Report, IR 0721015/2020201, February 24-27, 2020 and July 22, 2020, Inspection of NAC International in Norcross, Georgia Information Notice 2012-09, PWROG-16043-NP-A, Revision 2, PWROG Program to Address NRC Information Notice 2012-09: Irradiation Effects on Fuel Assembly Spacer Grid Crush Strength for Westinghouse and CE PWR Fuel Designs.2019-11-30030 November 2019 PWROG-16043-NP-A, Revision 2, PWROG Program to Address NRC Information Notice 2012-09: Irradiation Effects on Fuel Assembly Spacer Grid Crush Strength for Westinghouse and CE PWR Fuel Designs. Information Notice 2011-20, NRC060 - NRC Information Notice 2011-20: Concrete Degradation by Alkali-Silica Reaction (Nov. 18, 2011)2019-07-24024 July 2019 NRC060 - NRC Information Notice 2011-20: Concrete Degradation by Alkali-Silica Reaction (Nov. 18, 2011) ML19196A2452019-07-15015 July 2019 Public Notice - Sequoyah Nuclear Plant, Unit 2 - Exigent Amendment to Facility Operating License Information Notice 2019-01, Inadequate Evaluation of Temporary Alterations2019-03-12012 March 2019 Inadequate Evaluation of Temporary Alterations ML16028A3082016-04-27027 April 2016 NRC Information Notice; IN 2016-05: Operating Experience Regarding Complications From a Loss of Instrumentation Air Information Notice 2015-05, Inoperability of Auxiliary and Emergency Feedwater Auto Start Circuits on Loss of Main Feedwater Pumps2015-05-12012 May 2015 Inoperability of Auxiliary and Emergency Feedwater Auto Start Circuits on Loss of Main Feedwater Pumps Information Notice 2015-05, Inoperability Of Auxiliary And Emergency Feedwater Auto Start Circuits On Loss Of Main Feedwater Pumps2015-05-12012 May 2015 Inoperability Of Auxiliary And Emergency Feedwater Auto Start Circuits On Loss Of Main Feedwater Pumps Information Notice 2013-20, OFFICIAL EXHIBIT - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143)2013-10-0303 October 2013 OFFICIAL EXHIBIT - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143) Information Notice 2013-20, Official Exhibit - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143)2013-10-0303 October 2013 Official Exhibit - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143) Information Notice 2013-11, OFFICIAL EXHIBIT - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013)2013-07-0303 July 2013 OFFICIAL EXHIBIT - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013) Information Notice 2013-11, Official Exhibit - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013)2013-07-0303 July 2013 Official Exhibit - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013) Information Notice 2010-12, Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Contain2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2010-12, Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Con2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2010-12, Intervenors' Fifth Motion to Amend And/Or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notic2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend And/Or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2012-13, Boraflex Degradation Surveillance Programs and Corrective Actions in the Spent Fuel Pool2012-08-10010 August 2012 Boraflex Degradation Surveillance Programs and Corrective Actions in the Spent Fuel Pool Information Notice 2012-13, Boraflex Degradation Surveillance Programs And Corrective Actions In The Spent Fuel Pool2012-08-10010 August 2012 Boraflex Degradation Surveillance Programs And Corrective Actions In The Spent Fuel Pool Information Notice 2012-11, Age Related Capacitor Degradation2012-07-23023 July 2012 Age Related Capacitor Degradation ML12031A0132012-02-0606 February 2012 U.S. Nuclear Regulatory Commission Investigation Report No. 2-2010-058, Cpn International, Inc Information Notice 2011-19, Licensee Event Reports Containing Information Pertaining to Defects to Basic Components2011-09-26026 September 2011 Licensee Event Reports Containing Information Pertaining to Defects to Basic Components Information Notice 2011-15, Steel Containment Degradation and Associated License Renewal Aging Management Issues2011-08-0101 August 2011 Steel Containment Degradation and Associated License Renewal Aging Management Issues Information Notice 2011-17, Calculation Methodologies for Operability Determinations of Gas Voids in Nuclear Power Plant Piping2011-07-26026 July 2011 Calculation Methodologies for Operability Determinations of Gas Voids in Nuclear Power Plant Piping Information Notice 2011-13, Official Exhibit - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13)2011-06-29029 June 2011 Official Exhibit - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13) Information Notice 2011-13, Official Exhibit - Nys000329-00-Bd01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (Nrc in 2011-13)2011-06-29029 June 2011 Official Exhibit - Nys000329-00-Bd01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (Nrc in 2011-13) Information Notice 2011-13, OFFICIAL EXHIBIT - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13)2011-06-29029 June 2011 OFFICIAL EXHIBIT - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13) Information Notice 2011-04, IN: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 IN: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2011-04, In: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 In: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2011-04, in: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 in: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2010-26, New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-2010-12-30030 December 2010 New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-19 Information Notice 2010-26, New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review2010-12-30030 December 2010 New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-19 Information Notice 2010-26, 2010/12/21-NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-262010-12-21021 December 2010 2010/12/21-NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 ML13066A1872009-12-16016 December 2009 Draft NRC Information Notice 2009-xx - Underestimate of Dam Failure Frequency Used in Probabilistic Risk Assessments ML1007804482009-11-23023 November 2009 Email from Peter Bamford, NRR to Pamela Cowan, Exelon on TMI Contamination Control Event Information Notice 2009-11, NSP000059-Revised Prefiled Testimony of Northard/Petersen/Peterson-NRC Information Notice 2009-112009-07-0707 July 2009 NSP000059-Revised Prefiled Testimony of Northard/Petersen/Peterson-NRC Information Notice 2009-11 Information Notice 2009-10, Official Exhibit - NYS000019-00-BD01- NRC Information Notice 2009-10, Transformers Failures - Recent Operating Experience (Jul. 7, 2009) (NRC in 2009-10)2009-07-0707 July 2009 Official Exhibit - NYS000019-00-BD01- NRC Information Notice 2009-10, Transformers Failures - Recent Operating Experience (Jul. 7, 2009) (NRC in 2009-10) Information Notice 2009-09, Improper Flow Controller Settings Renders Injection Systems Inoperable and Surveillance Did Not Identify2009-06-19019 June 2009 Improper Flow Controller Settings Renders Injection Systems Inoperable and Surveillance Did Not Identify Information Notice 2008-12, Reactor Trip Due to Off-Site Power Fluctuation2008-07-0707 July 2008 Reactor Trip Due to Off-Site Power Fluctuation Information Notice 2008-11, Service Water System Degradation at Brunswicksteam Electric Plant Unit 12008-06-18018 June 2008 Service Water System Degradation at Brunswicksteam Electric Plant Unit 1 Information Notice 2008-04, Counterfeit Parts Supplied to Nuclear Power Plants2008-04-0707 April 2008 Counterfeit Parts Supplied to Nuclear Power Plants Information Notice 1991-09, Counterfeiting of Crane Valves2007-09-25025 September 2007 Counterfeiting of Crane Valves Information Notice 2007-28, Potential Common Cause Vulnerabilities in Essential Service Water Systems Due to Inadequate Chemistry Controls2007-09-19019 September 2007 Potential Common Cause Vulnerabilities in Essential Service Water Systems Due to Inadequate Chemistry Controls Information Notice 2007-29, Temporary Scaffolding Affects Operability of Safety-Related Equipment2007-09-17017 September 2007 Temporary Scaffolding Affects Operability of Safety-Related Equipment Information Notice 2007-14, Loss of Offsite Power and Dual-Unit Trip at Catawba Nuclear Generating Station2007-03-30030 March 2007 Loss of Offsite Power and Dual-Unit Trip at Catawba Nuclear Generating Station Information Notice 2007-06, Potential Common Cause Vulnerabilities in Essential Service Water Systems2007-02-0909 February 2007 Potential Common Cause Vulnerabilities in Essential Service Water Systems Information Notice 2007-05, Vertical Deep Draft Pump Shaft and Coupling Failures2007-02-0909 February 2007 Vertical Deep Draft Pump Shaft and Coupling Failures Information Notice 2006-31, Inadequate Fault Interrupting Rating of Breakers2006-12-26026 December 2006 Inadequate Fault Interrupting Rating of Breakers Information Notice 2006-29, Potential Common Cause Failure of Motor-operated Valves as a Result of Stem Nut Wear2006-12-14014 December 2006 Potential Common Cause Failure of Motor-operated Valves as a Result of Stem Nut Wear Information Notice 2006-29, Potential Common Cause Failure of Motor-operated Valves As a Result of Stem Nut Wear2006-12-14014 December 2006 Potential Common Cause Failure of Motor-operated Valves As a Result of Stem Nut Wear Information Notice 2006-13, E-mail from M. Mclaughlin on NRC, Regarding NRC Information Notice 2006-13: Groundwater Contamination2006-07-13013 July 2006 E-mail from M. Mclaughlin on NRC, Regarding NRC Information Notice 2006-13: Groundwater Contamination 2020-09-03 The following query condition could not be considered due to this wiki's restrictions on query size or depth: <code> [[:Beaver Valley]] OR [[:Millstone]] OR [[:Hatch]] OR [[:Monticello]] OR [[:Calvert Cliffs]] OR [[:Dresden]] OR [[:Davis Besse]] OR [[:Peach Bottom]] OR [[:Browns Ferry]] OR [[:Salem]] OR [[:Oconee]] OR [[:Mcguire]] OR [[:Nine Mile Point]] OR [[:Palisades]] OR [[:Palo Verde]] OR [[:Perry]] OR [[:Indian Point]] OR [[:Fermi]] OR [[:Kewaunee]] OR [[:Catawba]] OR [[:Harris]] OR [[:Wolf Creek]] OR [[:Saint Lucie]] OR [[:Point Beach]] OR [[:Oyster Creek]] OR [[:Watts Bar]] OR [[:Hope Creek]] OR [[:Grand Gulf]] OR [[:Cooper]] OR [[:Sequoyah]] OR [[:Byron]] OR [[:Pilgrim]] OR [[:Arkansas Nuclear]] OR [[:Three Mile Island]] OR [[:Braidwood]] OR [[:Susquehanna]] OR [[:Summer]] OR [[:Prairie Island]] OR [[:Columbia]] OR [[:Seabrook]] OR [[:Brunswick]] OR [[:Surry]] OR [[:Limerick]] OR [[:North Anna]] OR [[:Turkey Point]] OR [[:River Bend]] OR [[:Vermont Yankee]] OR [[:Crystal River]] OR [[:Haddam Neck]] OR [[:Ginna]] OR [[:Diablo Canyon]] OR [[:Callaway]] OR [[:Vogtle]] OR [[:Waterford]] OR [[:Duane Arnold]] OR [[:Farley]] OR [[:Robinson]] OR [[:Clinton]] OR [[:South Texas]] OR [[:San Onofre]] OR [[:Cook]] OR [[:Comanche Peak]] OR [[:Yankee Rowe]] OR [[:Maine Yankee]] OR [[:Quad Cities]] OR [[:Humboldt Bay]] OR [[:La Crosse]] OR [[:Big Rock Point]] OR [[:Rancho Seco]] OR [[:Zion]] OR [[:Midland]] OR [[:Bellefonte]] OR [[:Fort Calhoun]] OR [[:FitzPatrick]] OR [[:McGuire]] OR [[:LaSalle]] OR [[:05000000]] OR [[:Zimmer]] OR [[:Fort Saint Vrain]] OR [[:Shoreham]] OR [[:Satsop]] OR [[:Trojan]] OR [[:Atlantic Nuclear Power Plant]] OR [[:Skagit]] OR [[:Marble Hill]] </code>.
[Table view]The following query condition could not be considered due to this wiki's restrictions on query size or depth: <code> [[:Beaver Valley]] OR [[:Millstone]] OR [[:Hatch]] OR [[:Monticello]] OR [[:Calvert Cliffs]] OR [[:Dresden]] OR [[:Davis Besse]] OR [[:Peach Bottom]] OR [[:Browns Ferry]] OR [[:Salem]] OR [[:Oconee]] OR [[:Mcguire]] OR [[:Nine Mile Point]] OR [[:Palisades]] OR [[:Palo Verde]] OR [[:Perry]] OR [[:Indian Point]] OR [[:Fermi]] OR [[:Kewaunee]] OR [[:Catawba]] OR [[:Harris]] OR [[:Wolf Creek]] OR [[:Saint Lucie]] OR [[:Point Beach]] OR [[:Oyster Creek]] OR [[:Watts Bar]] OR [[:Hope Creek]] OR [[:Grand Gulf]] OR [[:Cooper]] OR [[:Sequoyah]] OR [[:Byron]] OR [[:Pilgrim]] OR [[:Arkansas Nuclear]] OR [[:Three Mile Island]] OR [[:Braidwood]] OR [[:Susquehanna]] OR [[:Summer]] OR [[:Prairie Island]] OR [[:Columbia]] OR [[:Seabrook]] OR [[:Brunswick]] OR [[:Surry]] OR [[:Limerick]] OR [[:North Anna]] OR [[:Turkey Point]] OR [[:River Bend]] OR [[:Vermont Yankee]] OR [[:Crystal River]] OR [[:Haddam Neck]] OR [[:Ginna]] OR [[:Diablo Canyon]] OR [[:Callaway]] OR [[:Vogtle]] OR [[:Waterford]] OR [[:Duane Arnold]] OR [[:Farley]] OR [[:Robinson]] OR [[:Clinton]] OR [[:South Texas]] OR [[:San Onofre]] OR [[:Cook]] OR [[:Comanche Peak]] OR [[:Yankee Rowe]] OR [[:Maine Yankee]] OR [[:Quad Cities]] OR [[:Humboldt Bay]] OR [[:La Crosse]] OR [[:Big Rock Point]] OR [[:Rancho Seco]] OR [[:Zion]] OR [[:Midland]] OR [[:Bellefonte]] OR [[:Fort Calhoun]] OR [[:FitzPatrick]] OR [[:McGuire]] OR [[:LaSalle]] OR [[:05000000]] OR [[:Zimmer]] OR [[:Fort Saint Vrain]] OR [[:Shoreham]] OR [[:Satsop]] OR [[:Trojan]] OR [[:Atlantic Nuclear Power Plant]] OR [[:Skagit]] OR [[:Marble Hill]] </code>. |
LIS ORIGINAL SSINS No.: 6835 IN 86-44 UNITED STATES
NUCLEAR REGULATORY COMMISSION
OFFICE OF INSPECTION AND ENFORCEMENT
WASHINGTON, D.C. 20555 June 10, 1986 IE INFORMATION NOTICE NO. 86-44: FAILURE TO FOLLOW PROCEDURES WHEN WORKING
IN HIGH RADIATION AREAS
Addressees
All nuclear power reactor facilities holding an operating license (OL) or a
construction permit (CP) and research and test reactors.
Purpose
This information notice is provided to alert licensees of the problem of
recurring, unauthorized entries by maintenance workers into high radiation
areas. A recent event is discussed below, and a related event is summarized in
Attachment 1. Since the workers ignored and bypassed maintenance procedures
that include radiological controls established to limit exposures in high
radiation areas, it is fortuitous that during these entries no personnel
exposure limits were exceeded.
It is expected that recipients will review this notice for applicability to
their facilities' work controls programs and consider actions, if appropriate, to preclude the occurrence of a similar problem at their facilities. Sugges- tions contained in this information notice do not constitute NRC requirements
and, therefore, no specific action or written response is required.
Past Related Correspondence:
INPO Significant Event Report (SER) 50-85, "Uncontrolled Personnel Radiation
Exposure," November 4, 1985 (discusses two events).
INPO Significant Operating Experience Report (SOER) 85-3, "Excessive Personnel
Radiation Exposures," April 30, 1985 (discusses seven events).
IE Information Notice No. 84-19, "Two Events Involving Unauthorized Entries
Into PWR Reactor Cavities," March 21, 1984.
IE Information Notice No. 84-59, "Deliberate Circumventing of Station Health
Physics Procedures," August 6, 1984 (discusses six events).
8606040010
IN 86-44 June 10, 1986
Description of Circumstances
On January 8, 1986, at Turkey Point, an instrument and controls (IC)technician
made an unaccompanied, unauthorized entry into a high radiation area to com- plete repairs on the traversing incore probe (TIP) drive unit with an irradi- ated TIP withdrawn into the work area. Earlier that same day, with a health
physics (HP) technician providing job coverage, the IC technician had made
adjustments to the TIP drive unit (dose rates only 5 to 25 mR/hr), which later
enabled the technician to successfully withdraw the TIP into the accessible TIP
drive work area.
During the unauthorized entry, the IC technician received 500 millirem whole
body exposure during an approximately 5-minute stay time in a work area, which
was later calculated to be 6 R/hr in the general area. The radiation level 1 foot away from the work area was 65-70 R/hr on contact with the tubing contain- ing the irradiated TIP. The low-range Geiger-Mueller (GM) portable survey
instrument (scale of 0-1 R/hr) used by the IC technician upon entering the high
radiation area initially moved up the scale to 800 mR/hr and then reportedly
went rapidly down the scale to zero, when moved closer the the radiation
source. The IC technician failed to recognize the malfunctioning survey
instrument and stayed in the area to complete his maintenance task. At these
dose rates, it was fortuitous that the technician did not remain in the TIP
area for any longer period.
Subsequent licensee and NRC regional review of the event revealed several key
factors that contributed to the incident.
1. Failure To Follow Procedures
Numerous procedural violations occurred before and during the unauthorized
entry. These violations included failure to notify HP personnel before
operating the TIP, performing craft work outside the scope of the author- ized plant work order (PWO), and making entry and working alone on the TIP
system.
2. Personnel Shortcomings
The IC technician's foreman failed to clearly define the TIP system problem
and provide adequate instructions on the PWO. The IC technician failed to
obey the local radiological area warning, a posting that read "high
radiation area - keep out." Inadequate training caused the IC technician
to fail to recognize a malfunctioning survey instrument (downscale reading
caused by GM detector tube continuous discharge response to intense
radiation levels), which he was using to help control his exposure.
The NRC noted subsequent to the event that, although not contributory to this
incident, governing maintenance procedures for the TIP system did not require
tagging out of other operable TIPs (to prevent inadvertent withdrawal into an
occupied work area) with work in progress on a malfunctioning TIP unit. For
future TIP work, the licensee agreed to control movement of the irradiated TIPs
with equipment tag out controls.
IN 86-44 June 10, 1986 Discussion:
The NRC continues to note repeated occurrences of unauthorized entries into
high radiation areas (see Past Related Correspondence). In most of the indi- vidual events discussed in these documents and the two events in this notice, failure of personnel to adhere to existing work/control procedures or radiation
work permits (RWP), or both, is a central cause of the exposure incidents.
Adherence to work/surveillance procedures forms a basic framework for providing
effective, consistent radiological controls for work in high radiation areas.
Short of providing direct, continuous health physics coverage for each and
every task, these procedures serve as the formal mechanism for initiating
necessary communications between various plant worker crafts groups and the
health physics support group. This communication results in appropriate
radiological support (e.g., RWP issuance) for the maintenance/surveillance
activities. Bypassing these procedures and thus failing to comply with the
radiological precautions in them seriously weakens the health physics control
program established to protect the workers. It is the licensee's responsibil- ity to ensure that these procedures are adhered to.
To emphasize the importance of workers properly performing work activities in
high radiation areas, appropriate enforcement action has been proposed for the
Turkey Point event (proposed $50,000 civil penalty).
No specific action or written response is required by this information notice.
If you have any questions about this matter, please contact the Regional
Administrator of the appropriate regional office or this office.
dwario Jor D , irector
Division of Emergency Preparedness
and Engineering Response
Office of Inspection and Enforcement
Technical Contacts: James E. Wigginton, IE
(301) 492-4967 Roger L. Pedersen, IE
(301) 492-9425 Attachments:
1. Related Exposure Event
2. List of Recently Issued IE Information Notices
Attachment 1 IN 86-44 June 10, 1986 RELATED EVENT SUMMARY
At the Cooper Nuclear Station on August 28, 1985, two IC technicians performed
maintenance (TIP alignment) as required by a craft work procedure. Contrary to
the work procedure's radiological-cautions warnings, these workers failed to
obtain a special RWP and entered the TIP drive enclosure housing, ignoring the
access posting, "Notify Health Physics Prior to Opening." The TIP maintenance
procedure further warned that the drive unit's Gleason reel is spring loaded
and the incore detector could be withdrawn by the spring tension. It further
warned that the withdrawn incore detector probe could be highly radioactive.
Upon opening the unsurveyed enclosure, they found the TIP had withdrawn into
the enclosure and the detector had broken off. The technicians immediately
exited the high radiation and high airborne radioactivity area. The indivi- duals each received approximately 200 mrem whole body exposure and airborne
intakes of 44 and 90 MPC-hrs.
As corrective actions, the licensee (1) stressed to all station personnel the
importance of properly following radiological controls and (2) revised the
governing maintenance procedure to require written documentation (signoff)
notifying HP before working on the TIP system.
Attachment 2 IN 86-44 June 10, 1986 LIST OF RECENTLY ISSUED
IE INFORMATION NOTICES
Information Date of
Notice No. Subject Issue Issued to
86-43 Problems With Silver Zeolite 6/10/86 All power reactor
Sampling Of Airborne Radio- facilities holding
iodine an OL or CP
86-42 Improper Maintenance Of 6/9/86 All power rector
Radiation Monitoring Systems facilities holding
an OL or CP
86-41 Evaluation Of Questionable 6/9/86 All byproduct
Exposure Readings Of Licensee material licensees
Personnel Dosimeters
86-32 Request For Collection Of 6/6/86 All power reactor
Sup. 1 Licensee Radioactivity facilities holding
Measurements Attributed to an OL or CP
The Chernobyl Nuclear Plant
Accident
86-40 Degraded Ability To Isolate 6/5/86 All power reactor
The Reactor Coolant System facilities holding
From Low-Pressure Coolant an OL or CP
Systems in BWRS
86-39 Failures Of RHR Pump Motors 5/20/86 All power reactor
And Pump Internals facilities holding
an OL or CP
86-38 Deficient Operator Actions 5/20/86 All power reactor
Following Dual Function Valve facilities holding
Failures an OL or CP
86-37 Degradation Of Station 5/16/86 All power reactor
Batteries facilities holding
an OL or CP
86-36 Change In NRC Practice 5/16/86- All power reactor
Regarding Issuance Of facilities holding
Confirming Letters To an OL or CP
Principal Contractors
OL = Operating License
CP = Construction Permit
|
---|
|
list | - Information Notice 1986-01, Failure of Main Feedwater Check Valves Causes Loss of Feedwater System Integrity and Water-Hammer Damage (6 January 1986)
- Information Notice 1986-02, Failure of Valve Operator Motor During Environmental Qualification Testing (6 January 1986)
- Information Notice 1986-03, Potential Deficiencies in Enviromental Qualification of Limitorque Motor Valve Operator Wiring (14 January 1986)
- Information Notice 1986-04, Transient Due to Loss of Power to Intergrated Control System at a Pressurized Water Reactor Designed by Babcock & Wilcox (31 January 1986)
- Information Notice 1986-05, Main Steam Safety Valve Test Failures and Ring Setting Adjustments (31 January 1986)
- Information Notice 1986-06, Failure of Lifting Rig Attachment, While Lifting Upper Guide Structure at St. Lucie Unit 1 (3 February 1986, Topic: Control of Heavy Loads)
- Information Notice 1986-06, Failure of Lifting Rig Attachment, while Lifting Upper Guide Structure at St. Lucie Unit 1 (3 February 1986)
- Information Notice 1986-07, Lack of Detailed Instruction & Inadequate Observance of Precautions During Maintenance & Testing of Diesel Generator Woodward Governors (3 February 1986)
- Information Notice 1986-08, Licensee Event Report (LER) Format Modification (3 February 1986)
- Information Notice 1986-09, Failure of Check & Stop Check Valves Subjected to Low Flow Conditions (3 February 1986)
- Information Notice 1986-10, Degradation of Reactor Coolant System Pressure Boundary Resulting From Boric Acid Corrosion. (5 January 1995, Topic: Boric Acid)
- Information Notice 1986-10, Feedwater Line Break (10 November 1988, Topic: Coatings, Anchor Darling)
- Information Notice 1986-10, Degradation of Reactor Coolant System Pressure Boundary Resulting from Boric Acid Corrosion. (5 January 1995, Topic: Boric Acid)
- Information Notice 1986-11, Anomalous Behavior of Recirculation Loop Flow in Jet Pump BWR Plants (31 December 1986)
- Information Notice 1986-13, Standby Liquid Control System Squib Valves Failure to Fire (21 February 1986, Topic: Squib)
- Information Notice 1986-13, Standby Liquid Control Squib Valves Failure to Fire (5 August 1986, Topic: Squib)
- Information Notice 1986-14, Overspeed Trips of AFW, HPCI & RCIC Turbines (26 August 1991, Topic: Fire Barrier)
- Information Notice 1986-14, Overspeed Trips of Afw, HPCI & RCIC Turbines (26 August 1991)
- Information Notice 1986-15, Loss of Offsite Power Caused by Problems in Fiber Optics Systems (10 March 1986, Topic: Squib)
- Information Notice 1986-16, Failures to Identify Containment Leakage Due to Inadequate Local Testing of BWR Vacuum Relief System Valves (11 March 1986, Topic: Squib)
- Information Notice 1986-17, Update of Failure of Automatic Sprinkler System Valves to Operate (24 March 1986, Topic: Squib)
- Information Notice 1986-18, NRC On-Scene Response During a Major Emergency (26 March 1986, Topic: Squib, Backfit)
- Information Notice 1986-19, Reactor Coolant Pump Shaft Failure at Crystal River (21 March 1986, Topic: Squib)
- Information Notice 1986-20, Low-Level Radioactive Waste Scaling Factors, 10 CFR Part 61 (28 March 1986, Topic: Squib)
- Information Notice 1986-21, Recognition of American Society of Mechanical Engineers Accreditation Program for N Stamp Holders (31 March 1986, Topic: Squib)
- Information Notice 1986-22, Underresponse of Radiation Survey Instrument to High Radiation Fields (31 March 1986, Topic: High Radiation Area, Squib)
- Information Notice 1986-23, Excessive Skin Exposures Due to Contamination with Hot Particles (9 April 1986)
- Information Notice 1986-23, Excessive Skin Exposures due to Contamination with Hot Particles (9 April 1986)
- Information Notice 1986-24, Respirator Users Notice: Increased Inspection Frequency for Certain Self-Contained Breathing Apparatus Air Cylinders (11 April 1986, Topic: Hydrostatic)
- Information Notice 1986-25, Traceability and Material Control of Material and Equipment, Particularly Fasteners (11 April 1986)
- Information Notice 1986-26, Potential Problems in Generators Manufactured by Electrical Products Incorporated (17 April 1986)
- Information Notice 1986-27, Access Control at Nuclear Facilities (21 April 1986, Topic: Contraband)
- Information Notice 1986-28, Telephone Numbers to the NRC Operations Center and Regional Offices (24 April 1986)
- Information Notice 1986-29, Effects of Changing Valve Moter-Operator Switch Settings (25 April 1986)
- Information Notice 1986-30, Design Limitations of Gaseous Effluent Monitoring Systems (29 April 1986)
- Information Notice 1986-31, Unauthorized Transfer and Loss of Control of Industrial Nuclear Gauges (14 July 1986)
- Information Notice 1986-32, Request for Collection of Licensee Radioactivity Measurements Attributed to Chernobyl Nuclear Plant Accident (2 May 1986, Topic: Chernobyl)
- Information Notice 1986-33, Information for Licensee Regarding the Chernobyl Nuclear Plant Accident (6 May 1986, Topic: Chernobyl)
- Information Notice 1986-34, Improper Assembly, Material Selection, & Test of Valves & Their Actuators (13 May 1986)
- Information Notice 1986-34, Improper Assembly, Material Selection, & Test of Valves & their Actuators (13 May 1986)
- Information Notice 1986-35, Fire in Compressible Material at Dresden Unit 3 (15 May 1986, Topic: Chernobyl)
- Information Notice 1986-36, Change in NRC Practice Regarding Issuance of Confirming Letters to Principal Contractors (16 May 1986, Topic: Chernobyl)
- Information Notice 1986-37, Degradation of Station Batteries (16 May 1986, Topic: Chernobyl)
- Information Notice 1986-38, Deficient Operator Actions Following Dual Function Valve Failures (20 May 1986, Topic: Chernobyl)
- Information Notice 1986-39, Failures of RHR Pump Motors and Pump Internals (20 May 1986, Topic: Chernobyl)
- Information Notice 1986-40, Degraded Ability to Isolate the Reactor Coolant System from Low-Pressure Coolant Systems in Bwrs (5 June 1986, Topic: Chernobyl)
- Information Notice 1986-40, Degraded Ability to Isolate the Reactor Coolant System from Low-Pressure Coolant Systems in BWRs (5 June 1986, Topic: Chernobyl)
- Information Notice 1986-41, Evaluation of Questionable Exposure Readings of Licensee Personnel Dosimeters (9 June 1986, Topic: Chernobyl)
- Information Notice 1986-42, Improper Maintenance of Radiation Monitoring Systems (9 June 1986, Topic: Temporary Modification, Chernobyl)
- Information Notice 1986-43, Problems with Silver Zeolite Sampling of Airborne Radioiodine (10 June 1986, Topic: Chernobyl)
... further results |
---|