Entergy Entergy Nuclear Northeast Entergy Nuclear Operations, Inc.

James A FitzPatrick NPP PO Box 110 Lycoming, NY 13093 Tel 315 349 6024 Fax 315 349 6480 April 15, 2003 JAFP-03-0052 T. A. Sullivan Vice President, Operations-JAF United States Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop O-P1-17 Washington, DC 20555

SUBJECT:

2002 PERSONNEL RADIATION EXPOSURE

SUMMARY

REPORT, DPR-59, DOCKET 50-333 Attached is the 2002 Personnel Radiation Exposure Summary Report submitted in accordance with the James A. FitzPatrick Nuclear Power Plant operating license DPR-59 Appendix A, Section 6.9(A)2a. The summary is formatted in accordance with Regulatory Guide 1.16.

For calendar year 2002 the total collective station dose was 230.294 person-rem (TEDE). The enclosed summary accounts for 96% of 229.40 person-rem which is the dose that can be attributed to the listed job functions.

The difference is due to occupational exposure received for work performed outside of the listed job functions.

If you have any questions concerning this report, please contact Marcia Anderson of the plant staff at 315-349-6724.

Very truly y0?Trvs RLB/TAS/bld Enclosure xc:

NRC Regional Administrator NRC Resident Inspector Kevin Pushee Licensing Mike Colomb RP File (3)

ENERGY NUCLEAR NORTHEAST JAMES A. FITZPATRICK NPP 2002 ANNUAL EXPOSURE

SUMMARY

NUMBER OF PERSONNEL AND PERSON-REM BY WORK AND JOB FUNCTION 3/28/2003 All Personnel Total Person-Rem Work and Job Function Station Utility Contractors Station Utility lContractors Employees lEmployees land Others Employees lEmployees land Others Reactor Operation and Surveillance

- Maintenance 19 0

1 31 0.311 l

0000 0.707

- Operations Personnel 21 0

1 100.189 0.000 1

0.000

- Health Physics 32 0

1 0.511 0.000 0.000

- Supervisory Personnel 19 0

12 0.101 0.000 0.181

- Engineering Personnel 4

1 11 0.024 0.000 0.049 Routine Maintenance

- Maintenance

[

127 2

874 27.949 0.006 81.989

- Operations Personnel 141 0

34 19.326 0.000 0.724

- Health Physics 74 0

62 13.463 0.000 4.647

- Supervisory Personnel 119 13 142 2.565 0.002 3.890

- Engineering Personnel 100 15 99 3.015 0.053 3.721 Inservice Inpsection

- Maintenance l

1 0

l 309 l

0.017 0.000 l

33.240

- Operations Personnel 25 0

1 2.036 0.000 0.201

- Health Physics 10 0

3

0.

2 0.000 0.014

- Supervisory Personnel 10 1

15 0.211 0.000 0.376

- Engineering Personnel 7

3 2

0.015 0.020 0.334 Special Maintenance

- Maintenance 4

l 0

l 0

l 0.000 l

0.000 l

0.000

- Operations Personnel 3

0 0

0.000 0.000 0.000

- Health Physics 19 0

0 0.001 0.000 0.000

- Supervisory Personnel 1

0 0

0.000 0.000 0.000

- Engineering Personnel 1

0 0

0.000 0.000 0.000 Waste Processing

- Maintenance l

0 l

0 l

0 l

0.000 0.000 0.000

- Operations Personnel 0

0 0 °0.000 0.000 0.000

- Health Physics 13 0

l 0

l 0.323 0.000 0.000

- Supervisory Personnel 0

0 J

0 ° 0.000 0.000 0.000

- Engineering Personnel 0

0 l

0 j

0.000 l

0.000 0.000 Refueling

- Maintenance l

50 l

0 l

62 l

1.314 l

0.000 10.101

- Operations Personnel 1

27 6

10.887 0.000 0.705

- Health Physics l

44 0

l 13 l

3.037 0.000 1.318

-Supervisory Personnel J

18 0

J 11 j

0.116 0.000 0.624

- Engineering Personnel 9

l 1

16 j

0.022 0.026 1.720 TOTALS

- Maintenance 211 l

2 J

1276 29.592 0.006 126.036

- Operations Personnel 217 1

0 1

42 22.438 1

0.000 1.630

- Health Physics 192 7

0 79 17.357 J 0.000 5.979

- Supervisory Personnel 167 l

14 180 2.994 1

0.002 5.071

- Engineering Personnel 121 l

20 128 3.075 j

0.099 5.824 GRAND TOTALS 908 36 1705 75.456 0.107 144.540

. 2