From:

"Kozyra, Jan" <jan.kozyra@pgnmail.com>

To:

"RLE@NRC.GOV" <RLE@NRC.GOV>, "SFX@NRC.GOV"

<SFX@NRC.GOV>

Date:

4/8/03 9:00AM

Subject:

Robinson IPEEE Fire Analysis During the conference call on April 2, 2003, NRC asked if we would review the IPEEE fire analysis to see if there were additional cost effective improvements. We did a review and looked at historical activities.

On three separate occasions we have reviewed the IPEEE fire analysis for risk insights. Since the original IPEEE was prepared, a significant reduction in fire CDF has been achieved and additional conservatisms identified. We did not identify any further cost effective improvements.