CPSES-200200528, Annual Operating Report for 2001

From kanterella
(Redirected from ML020710639)
Jump to navigation Jump to search
Annual Operating Report for 2001
ML020710639
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 02/28/2002
From: Terry C, Walker R
TXU Electric
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
CPSES-200200528, TXX-02040
Download: ML020710639 (19)


Text

t TXU TXU Electric C. Lance Terry Comanche Peak Senior Vice President & Principal Nuclear Officer Steam Electric Station P. O. Box 1002 Glen Rose,TX 76043 Tel: 254 897 8920 Fax:254 897 6652 lance.terry@txu.com CPSES-200200528 Log # TXX-02040 File # 10250 (RP-85)

Ref. # 10CFR50.36 February 28, 2002 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET NOS. 50-445 AND 50-446 ANNUAL OPERATING REPORT FOR 2001 Gentlemen:

Attached is the CPSES Annual Operating Report for 2001 prepared and submitted pursuant to guidance provided in C. .b of U.S. NRC Regulatory Guide 1.16, Revision

4. The attachment also submits the annual Occupational Radiation Exposure Report as required by Technical Specification 5.6.1 contained in Appendix A to the Comanche Peak Steam Electric Station Unit 1 Operating License NPF-87 and Unit 2 Operating License NPF-89.

If you have any questions, please contact Mr. Douglas W. Snow at (254) 897-8448.

This communication contains no new licensing basis commitments regarding CPSES Units 1 and 2.

/A-00O

TxU CPSES-200200528 TXX-02040 PAGE 2 OF 2 Sincerely, TXU Generation Company LP By: TXU Generation Management Company LLC Its General Partner C. L. Terry Senior Vice President and Principal Nuclear Officer By:

RoaD. Walker Regulatory Affairs Manager DWS/dws Attachment c- E. W. Merschoff, Region IV D. N. Graves, Region IV D. H. Jaffe, NRR Resident Inspectors, CPSES Mail Original copy of Personnel Exposure & Monitoring Report to:

Ms. M.L. Thomas, REIRS Project Manager Office of Nuclear Regulatory Research U.S. Nuclear Regulatory Commission Washington, DC 20555

CPSES-200200528 Attachment to TXX-02040 COMANCHE PEAK STEAM ELECTRIC STATION ANNUAL OPERATING REPORT 2001 TXU Generation Company LP I

CPSES-200200528 Attachment to TXX-02040 TABLE OF CONTENTS 1.0 Summary of Operating Experience 2.0 Outages and Reductions in Power 3.0 Personnel Exposure and Monitoring Report 4.0 Irradiated Fuel Inspection Results 5.0 Outage Related Single Radioactivity Release or Radiation Exposure to an Individual that Accounts for More than 10 Percent of Allowable Annual Values 2

CPSES-200200528 Attachment to TXX-02040 1.0

SUMMARY

OF OPERATING EXPERIENCE The Comanche Peak Steam Electric Station (CPSES) is a dual unit pressurized water reactor power plant, Unit 1 is licensed at 3411 Megawatt thermal (MWt) and Unit 2 is licensed at 3458 MWt. It is located in Somervell County in North Central Texas approximately 65 miles southwest of the Dallas-Fort Worth Metropolitan area. The nuclear steam supply system was purchased from Westinghouse Electric Corporation and is rated for a 3425 MWt output. On October 16, 2001, Unit 2 implemented Technical Specification Amendment 89 and TRM Rev.

38, increasing the rating of Unit 2 from 3445 MWt to 3458 MWt output.

1.1 CPSES UNIT I CPSES Unit 1 achieved initial criticality on April 3, 1990. Initial power generation occurred on April 24, 1990, and the plant was declared commercial on August 13, 1990. Since being declared commercial, CPSES Unit 1 has generated 91,573,905 net Megawatt-hours (MWH) of electricity as of December 31, 2001, with a net unit capacity factor of 79.8% (using MDC). The unit and reactor availability factors were 86.6% and 90.3%, respectively, for the year 2001.

On March 24, 2001, the unit began the power ramp down for its eight refueling outage. The unit entered the refueling outage on March 24.

During the refueling outage, 92 fresh fuel assemblies were loaded for Cycle 9. The refueling outage lasted 29 days and ended on April 22, 2001. Unit 1 was returned to 100% power on April 28, 2001.

During the refueling outage, the major work scope completed included:

  • Power range detector replacement
  • Replaced flux thimble tube
  • Smart Motor Modification on RCP 1-03
  • Low Pressure Turbine and Casing Replacement.
  • Eddy current inspection of Last Stage Blades for both LP Turbines
  • Refueling machine Modifications for increased reliability Figure 1.1-1 provides the generation profile of the average daily net electrical output of Unit I for 2001. Table 1.1-1 is a compilation of the monthly summaries of the operating data and Table 1.1-2 contains the yearly and total summaries of the operating data.

1.2 CPSES UNIT 2 CPSES Unit 2 achieved initial criticality on March 24, 1993. Initial power generation occurred on April 9, 1993, and the plant was declared commercial on August 3, 1993. Since being declared commercial, CPSES Unit 2 has generated 70,138,093 net Megawatt-hours (MWH) of electricity as of December 31, 2001, with a net unit capacity factor of 82.7% (using MDC). The unit and reactor availability factors were 88.3% and 92.0%, respectively, for the year 2001.

There were no refueling outages for this unit in 2001. During this reporting period there were no failures or challenges to the Power Operated Relief Valves or Safety Valves.

3

CPSES-200200528 Attachment to TXX-02040 On October 16, 2001, Unit 2 implemented Technical Specification Amendment 89 and TRM Rev. 38, increasing the rating of Unit 2 from 3445 MWt to 3458 MWt output.

Figure 1.2-1 provides the generation profile of the average daily net electrical output of Unit 2 for 2001. Table 1.2-1 is a compilation of the monthly summaries of the operating data and Table 1.2-2 contains the yearly and the total summaries of the operating data.

During this reporting period there were no failures or challenges to the Safety Valves.

2.0 OUTAGES AND REDUCTIONS IN POWER 2.1 CPSES UNIT 1 Table 2.1 describes unit operating experience including unit shutdowns and provides explanations of significant dips in average power levels for CPSES Unit 1.

2.2 CPSES UNIT 2 Table 2.2 describes unit operating experience including unit shutdowns and provides explanations of significant dips in average power levels for CPSES Unit 2.

3.0 EXPOSURE AND MONITORING REPORT The personnel exposure and monitoring report for CPSES is provided in Table 3.0.

4.0 IRRADIATED FUEL INSPECTION RESULTS 4.1 CPSES UNIT 1 The reactor coolant fission product activity levels were carefully monitored throughout Unit 1, Cycle 8. Analysis of the activity levels indicated no leaking fuel throughout the cycle. During refueling outage 1RFO8, visual inspections were performed by inspection personnel from the edge of the spent fuel pool to assess the external condition of the fuel assemblies. Underwater camera inspections of randomly selected fuel assemblies were also performed. During 2001, several Westinghouse fueled plants continued to report fractured fuel assembly top nozzle holddown spring screws. As a result, underwater camera visual inspections of the top nozzle clamps of the only Westinghouse fuel assembly which operated in Cycle 8 was performed in order to observe any indications of fractured holddown spring screw damage. All fuel assemblies inspected appeared to be in good condition with no anomalies observed.

4.2 CPSES UNIT 2 There were no irradiated fuel inspections performed on Unit 2 fuel since Unit 2 did not have a refueling outage in 2001.

4

CPSES-200200528 Attachment to TXX-02040 4.3 CPSES FUEL POOL As a result of reports of potential top nozzle separation in certain Westinghouse fuel assemblies, CPSES performed underwater camera visual inspections of 9 of 26 Westinghouse fuel assemblies at CPSES that were identified as potentially susceptible to this condition. The inspections were performed in the CPSES spent fuel pool area in June 2001, and consisted of underwater camera visual inspections of a sample of the top nozzle-to-guide tube bulge joints in each of the 9 assemblies. Also, a Westinghouse review of CPSES spent fuel pool chemistry had concluded that the chemistry data was considered good and that potentially susceptible fuel could be handled normally. The results of the visual inspections showed no significant indications of guide tube sleeve corrosion, which would lead to top nozzle separation.

5.0 OUTAGE RELATED SINGLE RADIOACTIVITY RELEASE OR RADIATION EXPOSURE TO AN INDIVIDUAL THAT ACCOUNTS FOR MORE THAN 10 PERCENT OF ALLOWABLE ANNUAL VALUES CPSES Units 1 and 2 did not experience any single release of radioactivity greater than 10% of an allowable dose limit during an outage or forced reduction in power of over 20% of designed power level during 2001.

During 2001 CPSES 1 conducted a refueling outage (see section and 1.1). During the outage activities, two individuals received radiation exposure exceeding 10% of an allowable dose limit in a single exposure event. Exposure is tabulated in Table 6.0.

5

CPSES-200200528 Attachment to TXX-02040 FIGURE 1.1-1 COMANCHE PEAK STEAM ELECTRIC STATION - UNIT 1 GENERATION PROFILE AVERAGE DAILY UNIT POWER LEVEL for 2001 NRC UNIT I GENERATION PROFILE Daily Unit Power Level 1,400 1,200 1,000 800 600 400 200 0

JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 6

CPSES-200200528 Attachment to TXX-02040 TABLE 1.1-1 (PAGE 1 OF 2)

COMANCHE PEAK STEAM ELECTRIC STATION - UNIT 1 MONTHLY ELECTRIC POWER GENERATION DATA (2001)

January February March April May June Hours RX was Critical 744 672 565.5 224.7 744 720 RX Reserve Shutdown Hours 0 0 0 0 0 0 Hours Generator On-line 744 672 565.6 200.7 744 720 Unit Reserve Shutdown Hours 0 0 0 0 0 0 Gross Thermal Energy Generated (MWH) 2,497,884 2,290,169 1,839,526 509,186 2,535,590 2,453,316 Gross Electric Energy Generated (MWH) 841,880 775,826 621,059 171,025 860,289 825,328 Net Electric Energy Generated (MWH) 809,489 746,416 594,420 156,022 824,791 791,051 RX Service Factor (%) 100.0 100.0 76.0 31.2 100.0 100.0 RX Availability Factor(%) 100.0 100.0 76.0 31.2 100.0 100.0 Unit Service Factor (%) 100.0 100.0 76.0 27.9 100.0 100.0 Unit Availability Factor (%) 100.0 100.0 76.0 29.9 100.0 100.0 Unit Capacity Factor(%, using MDC net) 94.6 96.6 69.5 18.9 96.4 95.5 Unit Capacity Factor(%, using DER net) 94.6 96.6 69.5 18.9 96.4 95.5 Unit Forced Outage Rate (%) 0.0 0.0 0.0 0.0 0.0 0.0 Hours in Month 744 672 744 719 744 720 7

CPSES-200200528 Attachment to TXX-02040 TABLE 1.1-1 (PAGE 2 OF 2)

COMANCHE PEAK STEAM ELECTRIC STATION - UNIT 1 MONTHLY ELECTRIC POWER GENERATION DATA (2001)

July August September October November December Hours RX was Critical 744 505.4 720 745 720 744 RX Reserve Shutdown Hours 0 238.6 0 0 0 0 Hours Generator On-line 744 463.8 720 745 720 744 Unit Reserve Shutdown Hours 0 0 0 0 0 0 Gross Thermal Energy Generated (MWH) 2,532,595 1,547,417 2,453,381 2,538,204 2,451,413 2,533,493 Gross Electric Energy Generated (MWH) 845,417 513,078 823,704 859,399 829,190 860,315 Net Electric Energy Generated (MWH) 809,808 481,606 789,870 822,826 795,545 822,474 RX Service Factor (%) 100.0 67.9 100.0 100.0 100.0 100.0 RX Availability Factor (%) 100.0 100.0 100.0 100.0 100.0 100.0 Unit Service Factor (%) 100.0 62.3 100.0 100.0 100.0 100.0 Unit Availability Factor (%) 100.0 62.3 100.0 100.0 100.0 100.0 Unit Capacity Factor(%, using MDC net) 94.6 56.3 95.4 96.0 96.1 96.1 Unit Capacity Factor(%, using DER net) 94.6 56.3 95.4 96.0 96.1 96.1 Unit Forced Outage Rate (%) 0.0 37.7 0.0 0.0 0.0 0.0 Hours in Month 744 744 720 745 720 744 8

CPSES-200200528 Attachment to TXX-02040 TABLE 1.1-2 COMANCHE PEAK STEAM ELECTRIC STATION - UNIT 1 ANNUAL ELECTRIC POWER GENERATION DATA (2001)

YEAR CUMULATIVE Hours RX was Critical 7,848.7 87,234 RX Reserve Shutdown Hours 238.6 2,871 Hours Generator On-line 8,784 78,665 Unit Reserve Shutdown Hours 0 0 Gross Thermal Energy Generated (MWH) 26,182,174 285,982,131 Gross Electric Energy Generated (MWH) 8,826,510 95,766,621 Net Electric Energy Generated (MWH) 8,444,318 91,573,905 RX Service Factor (%) 89.6 87.4 RX Availability Factor (%) 92.3 90.3 Unit Service Factor (%) 88.8 86.6 Unit Availability Factor (%) 88.8 86.6 Unit Capacity Factor(%, using MDC net) 83.8 79.8 Unit Capacity Factor(%, using DER net) 83.8 79.8 Unit Forced Outage Rate (%) 3.5 3.0 9

CPSES-200200528 Attachment to TXX-02040 FIGURE 1.2-1 COMANCHE PEAK STEAM ELECTRIC STATION - UNIT 2 GENERATION PROFILE AVERAGE DAILY UNIT POWER LEVEL for 2001 UNIT 2 GENERATION PROFILE Daily Unit Power Level 1,400 1,200

- --u 1,000 Electro Hydraulic Control Pressure Switch Failure Automatic Reactor 800 Trip due to Spurious Signal from AMSAC Indicator 600 400 200 0

JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 10

CPSES-200200528 Attachment to TXX-02040 TABLE 1.2-1 (PAGE 1 OF 2)

COMANCHE PEAK STEAM ELECTRIC STATION - UNIT 2 MONTHLY ELECTRIC POWER GENERATION DATA (2001)

January February March April May June Hours RX was Critical 744 672 744 719 744 720 RX Reserve Shutdown Hours 0 0 0 0 0 0 Hours Generator On-line 744 672 744 719 744 720 Unit Reserve Shutdown Hours 0 0 0 0 0 0 Gross Thermal Energy Generated (MWH) 2,560,733 2,308,855 2,551,289 2,478,854 2,561,153 2,474,729 Gross Electric Energy Generated (MWH) 881,704 795,045 877,443 852,120 878,011 842,391 Net Electric Energy Generated (MWH) 849,500 765,984 844,311 818,892 845,478 810,717 RX Service Factor (%) 100.0 100.0 100.0 100.0 100.0 100.0 RX Availability Factor (%) 100.0 100.0 100.0 100.0 100.0 100.0 Unit Service Factor (%) 100.0 100.0 100.0 100.0 100.0 100.0 Unit Availability Factor (%) 100.0 100.0 100.0 100.0 100.0 100.0 Unit Capacity Factor(%, using MDC net) 99.3 99.1 98.7 99.0 98.8 97.9 Unit Capacity Factor(%, using DER net) 99.3 99.1 98.7 99.0 98.8 97.9 Unit Forced Outage Rate (%) 0.0 0.0 0.0 0.0 0.0 0.0 Hours in Month 744 672 744 719 744 720 11

CPSES-200200528 Attachment to TXX-02040 TABLE 1.2-1 (PAGE 2 OF 2)

COMANCHE PEAK STEAM ELECTRIC STATION - UNIT 2 MONTHLY ELECTRIC POWER GENERATION DATA (2001)

July Augus September October November December Hours RX was Critical 724.6 744 707.52 745 720 744 RX Reserve Shutdown Hours 0 0 0 0 0 0 Hours Generator On-line 715 744 707.52 745 720 744 Unit Reserve Shutdown Hours 0 0 0 0 0 0 Gross Thermal Energy Generated (MWH) 2,431,970 2,560,721 2,478,055 2,565,725 2,486,882 2,569,795 Gross Electric Energy Generated (MWH) 820,754 864,510 841,292 878,006 853,557 882,796 Net Electric Energy Generated (MWH) 787,919 831,509 809,215 844,979 818,754 850,689 RX Service Factor (%) 97.4 100.0 100.0 100.0 100.0 100.0 RX Availability Factor (%) 97.4 100.0 100.0 100.0 100.0 100.0 Unit Service Factor (%) 96.1 100.0 100.0 100.0 100.0 100.0 Unit Availability Factor (%) 96.1 100.0 100.0 100.0 100.0 100.0 Unit Capacity Factor(%, using MDC net) 92.1 97.2 97.7 98.6 98.9 99.4 Unit Capacity Factor(%, using DER net) 92.1 97.2 97.7 98.6 98.9 99.4 Unit Forced Outage Rate (%) 0.0 0.0 0.0 0.0 0.0 0.0 Hours in Month 744 744 720 745 720 744 12

CPSES-200200528 Attachment to TXX-02040 TABLE 1.2-2 COMANCHE PEAK STEAM ELECTRIC STATION - UNIT 2 ANNUAL ELECTRIC POWER GENERATION DATA (2001)

YEAR CUMULATIVE Hours RX was Critical 8,740.6 65,503 RX Reserve Shutdown Hours 0 2,366 Hours Generator On-line 8,731.0 65,089 Unit Reserve Shutdown Hours 0 0 Gross Thermal Energy Generated (MWH) 30,028,761 215,590,765 Gross Electric Energy Generated (MWH) 10,267,629 73,148,859 Net Electric Energy Generated (MWH) 9,877,947 70,138,093 RX Service Factor (%) 99.8 88.8 RX Availability Factor (%) 99.8 92.0 Unit Service Factor (%) 99.7 88.3 Unit Availability Factor (%) 99.7 88.3 Unit Capacity Factor(%, using MDC net) 98.1 82.7 Unit Capacity Factor(%, using DER net) 98.1 82.7 Unit Forced Outage Rate (%) 0.3 3.1 13

CPSES-200200528 Attachment to TXX-02040 TABLE 2.1 (PAGE 1 OF 1)

COMANCHE PEAK STEAM ELECTRIC STATION - UNIT 1 UNIT OPERATING EXPERIENCE INCLUDING SHUTDOWNS AND POWER REDUCTIONS DURING 2001 METHOD OF TYPE SHUTTING DOWN F: FORCED DURATION* THE REACTOR OR NO DATE S: SCHEDULED (HOURS) REASON REDUCING POWER CORRECTIVE ACTION/COMMENTS 1 010125 F A 4 At 0819 on January 25, 2001, the unit began downpower to 88% power to repair feedwater heater 11B tube leak. The leak was repaired and the unit returned to 100% power at 0530 on January 28, 2001.

2 010324 S 178.4 C 4 At 1336, on March 24, 2001, the unit initiated a manual reactor trip per procedure to begin IRF08 refueling outage. The unit ended the month in Mode 6 in 1RF08.

2a 010401 S 518.3 C 4 At 1336, on March 24, 2001, the unit initiated a manual reactor trip per procedure to begin 1RF08 refueling outage. The unit began the month of April in Mode 6 in 1RF08. The refueling was completed and the unit returned to power operations, sync to grid at 1516 on April 22, 2001. The unit returned to 100% power on April 27, 2001 at 1720.

3 010818 F 280.20 A I On August 18, 2001 at 0335, the unit began to power down to repair a leak in the primary water system. The unit was taken offline at 0601 August 18, 2001. The leak was isolated to the main generator exciter rotor. The exciter rotor was repaired and replaced and the unit returned to power operations on August 29, 2001 at 2213.

The unit returned to full power on August 30, 2001 at 1806.

I) REASON

2) METHOD A: EQUIPMENT FAILURE (EXPLAIN) E: OPERATOR TRAINING AND LICENSE EXAMINATION I: MANUAL B: MAINT OR TEST F: ADMINISTRATIVE 2: MANUAL SCRAM C: REFUELING G: OPERATIONAL ERROR (EXPLAIN) 3: AUTOMATIC SCRAM D: REGULATORY RESTRICTION H: OTHER (EXPLAIN) 4: OTHER (EXPLAIN)
  • INDICATES SHUTDOWN HOURS/OTHERWISE "NA" FOR NOT APPLICABLE 14

Attachment to TXX-02040 TABLE 2.2 (PAGE 1 OF 1)

COMANCHE PEAK STEAM ELECTRIC STATION - UNIT 2 UNIT OPERATING EXPERIENCE INCLUDING SHUTDOWNS AND POWER REDUCTIONS DURING 2001 METHOD OF TYPE SHUTTING DOWN F: FORCED DURATION* THE REACTOR OR NO DATE S: SCHEDULED (HOURS) REASON REDUCING POWER CORRECTIVE ACTION/COMMENTS 1 010718 F 29.00 A 3 On July 18, 2001 at 0759, the unit experienced a turbine trip/ reactor trip from 100% power due to a spurious signal from a short in an AMSAC (Anticipated Transient Without SCRAM Mitigation System Actuation Circuitry) indicator. The AMSAC indicator was repaired and the unit returned to power operations. The unit was critical on July 19, 2001 at 0322 and sync to the grid at 1259. The unit returned to 100% power on July 20 at 0620. During this event the Atmospheric Relief Valves opened slightly in auto. (Reference LER 446-2001 -001-00)

1) REASON 2) METHOD A: EQUIPMENT FAILURE (EXPLAIN) E: OPERATOR TRAINING AND LICENSE EXAMINATION 1: MANUAL B: MAINT OR TEST F: ADMINISTRATIVE 2: MANUAL SCRAM C: REFUELING G: OPERATIONAL ERROR (EXPLAIN) 3: AUTOMATIC SCRAM D: REGULATORY RESTRICTION H: OTHER (EXPLAIN) 4: OTHER (EXPLAIN)
  • INDICATES SHUTDOWN HOURS/OTHERWISE DNAfl FOR NOT APPLICABLE 15

Attachment to TXX-02040 TABLE 3.0 COMANCHE PEAK STEAM ELECTRIC STATION - UNITS 1 AND 2 2001 PERSONNEL EXPOSURE AND MONITORING REPORT

  1. Personnel Total Person - rem Work & Job Function Station Utility Contract Station Utilitiy Contract Reactor Operations & Surveillance Maintenance & Construction 147 0 167 0.311 .000 0.299 Operations 315 0 183 2.294 .000 0.171 Health Physics & Lab 56 0 39 1.413 .000 0.098 Supervisory & Office Staff 40 1 9 0.029 .000 0.034 Engineering Staff 162 0 84 0.331 .000 0.063 Routine Plant Maintenance Maintenance & Construction 207 0 471 3.618 .000 22.125 Operations 147 0 30 3.290 .000 0.305 Health Physics & Lab 44 0 72 1.158 .000 3.386 Supervisory & Office Staff 18 0 2 0.067 .000 0.147 Engineering Staff 73 0 135 0.917 .000 0.516 In-service Inspection Maintenance & Construction 4 0 7 0.110 .000 0.018 Operations 10 0 3 0.426 .000 0.471 Health Physics & Lab 21 0 22 1.374 .000 1.961 Supervisory & Office Staff 0 0 0 0.000 .000 0.000 Engineering Staff 4 0 115 0.009 .000 28.487
  • Special Plant Maintenance Maintenance & Construction 56 0 195 0.625 .000 22.406 Operations 43 0 10 0.166 .000 0.663 Health Physics & Lab 41 0 7 0.268 .000 0.013 Supervisory & Office Staff 6 0 0 0.021 .000 0.000 Engineering Staff 28 0 56 0.526 .000 6.830 Waste Processing Maintenance & Construction 21 0 21 0.081 .000 0.203 Operations 24 0 9 0.283 .000 0.274 Health Physics & Lab 36 0 21 0.619 .000 0.173 Supervisory & Office Staff 0 0 0 0.000 .000 0.000 Engineering Staff 1 0 0 0.017 .000 0.000 Refueling Maintenance & Construction 72 0 112 0.771 .000 1.698 Operations 44 0 4 1.091 .000 0.009 Health Physics & Lab 26 0 32 0.698 .000 1.617 Supervisory & Office Staff 3 0 0 0.045 .000 0.000 Engineering Staff 20 1 63 0.320 .001 11.749 Totals Maintenance & Construction 507 0 973 5.516 .000 46.748 Operations 583 0 239 7.549 .000 1.893 Health Physics & Lab 224 0 193 5.529 .000 7.247 Supervisory & Office Staff 67 1 11 0.162 .000 0.182 Engineering Staff 288 1 453 2.122 .001 47.644 Grand Totals 1669 2 1869 20.879 0.001 103.714
  • PRZ Spray Permanent Shielding, PRZ Compartment permanent platform, Modify S/G Platform access, Grating clamp replacement, Festoon modification/Crane Digital Controls, Spent Fuel Rerack.

16

CPSES-200200528 Attachment to TXX-02040 TABLE 6.0 2001 COMANCHE PEAK STEAM ELECTRIC STATION - UNITS I AND 2 OUTAGE RELATED RADIATION EXPOSURE TO AN INDIVIDUAL FOR A SINGLE MAINTENANCE ACTIVITY WHICH EXCEEDS 10 PERCENT OF AN ALLOWABLE ANNUAL DOSE LIMIT*

Individual's Maintenance Single Event Total Annual Activit Department Exposure (mrem) Exposure (mrem)

Steam Generator Nozzle DES Inc. 715 818 Dam Installation Steam Generator Nozzle DES Inc. 530 815 Dam Removal