UNITED STATES

NUCLEAR REGULATORY COMMISSION

OFFICE OF NUCLEAR REACTOR REGULATION

WASHINGTON, D.C. 20555-0001

January 18, 2002

NRC INFORMATION NOTICE 2002-06:

DESIGN VULNERABILITY IN BWR REACTOR

VESSEL LEVEL INSTRUMENTATION BACKFILL

MODIFICATION

Addressees

All holders of operating licenses or construction permits for boiling water reactors (BWRs).

Purpose

The U.S. Nuclear Regulatory Commission (NRC) is issuing this information notice to alert

addressees to a potential design vulnerability in a hardware modification to the reactor vessel

water level instrumentation system. It is expected that recipients will review the information for

applicability to their facilities and consider actions, as appropriate, to avoid similar problems.

However, suggestions contained in this information notice are not NRC requirements; therefore, no specific action or written response is required.

Background

NRC Bulletin (NRCB) 93-03, Resolution of Issues Related to Reactor Vessel Water Level

Instrumentation in BWRs, issued on May 28, 1993, requested that licensees implement

hardware modifications necessary to ensure the level instrumentation system design is of high

functional reliability for long-term operation. In response to this bulletin, all BWR licensees with

the exception of Big Rock Point, which does not use cold-reference-leg instrumentation, have

either implemented or committed to implement modifications. The majority of these licensees

have decided to install a reference leg backfill system to supply a continuous flow of water from

the control rod drive (CRD) hydraulic system through the reference legs. The back-fill system

precludes migration of dissolved noncondensible gases down the legs. In August 2001, a

design vulnerability in this backfill modification was found at the Pilgrim Nuclear Power Station.

Description of Circumstances

It was discovered that, under certain conditions, the safety-related reactor vessel water level

indicators that provide certain safety-related initiation signals could give nonconservative water

level readings. During a reactor trip at Pilgrim, both trains of the emergency core cooling

system (ECCS) reactor water level instruments indicated higher than actual levels. These

instrument inaccuracies were noted after operator actions were taken to isolate the CRD

system charging water header supply valve, CRD 301-25, to insert a control rod that had not

settled at position 00. Closure of the charging water header isolates the ECCS level indicator

reference-leg backfill system (see Attachment 1). The erroneous readings were attributed to

the reference legs draining back through the reference-leg keepfill system to the CRD hydraulic

control units (HCUs). With the CRD charging header valve shut, the reactor scram reset, and

reactor pressure rising, the reference legs drained back to the HCUs. This occurs when the

CRD system pump is secured or the charging header isolation valve is closed, the source of the

reference-leg keepfill system, is at a slightly lower pressure than the reactor so that the

differential pressure across the keepfill system check valve is not sufficient to fully seat the

check valves. The draining of the reference legs results in a transient false reference-leg

indication until the check valves seat and the reference legs refill via the condensate pots or

flow is reestablished through the CRD reference leg backfill system. Pilgrim concluded that this

phenomenon can occur with either the isolation of the reference leg backfill system or possibly

with the loss of the running CRD pump.

During the reactor scam at Pilgrim, this event resulted in both the wide-range vessel level

instruments indicating higher than actual water level with the A train reaching a maximum

deviation of 26 inches and the B train reaching a maximum of 11 inches. These erroneous high

readings occurred for approximately 30 minutes. During this time, the automatic emergency

core cooling system initiation function would not have occurred on low-low water level as

designed. This false reading is due to the relative locations of the reactor vessel instrument

nozzles and the differential pressure corresponding to the ECCS initiation setpoint.

Related Generic Communications:

NRC Information Notice 93-89

Potential Problems With BWR Level Instrumentation

Backfill Modifications, November 26, 1993 NRC Information Notice 92-54

Level Instrumentation Inaccuracies Caused by Rapid

Depressurization, July 24, 1992 Generic Letter 92-04 Resolution of the Issues Related to Reactor Vessel Water

Level Instrumentation in BWRs Pursuant to 10 CFR

50.54(f), August 19, 1992 NRC Information Notice 93-27

Level Instrumentation Inaccuracies Observed During

Normal Plant Depressurization, April 8, 1993 NRC Bulletin 93-03

Resolution of Issues Related to Reactor Vessel Water

Level Instrumentation in BWRs, May 28, 1993 This information notice requires no specific action or written response. If you have any

questions regarding the information notice, please contact the technical contacts listed below or

the appropriate Office of Nuclear Reactor Regulation (NRR) project manager.

/RA/

William D. Beckner, Program Director

Operating Reactor Improvements Program

Division of Regulatory Improvement Programs

Office of Nuclear Reactor Regulation

Technical contacts:

R. Arrighi, Region I

Thomas Koshy, NRR

508-747-0565

301-415-1176 E-mail: rja1@nrc.gov

E-mail: txk@nrc.gov

Attachments:

1. Sketch of Backfill Modification

2. List of Recently Issued NRC Information Notices

ML013470481

  • See previous concurrence

OFFICE

RORP

TECH ED

REG I:RI

DSSA/SRXB

(A) SC:RORP

PD:RORP

NAME

TKoshy

PKleene*

RArrighi*

JWermiel*

TKoshy*

WDBeckner*

DATE

01/ /2002

12/04/2001

12/17/2001

01/17/2002

01/17/2002

01/18/2002

RWL Reference Leg Backfill

HCUs

301-25 Scram Vlvs

CRD Pumps

Needle Valve

Charging Water Line

Variable Leg

Variable Leg

Reference Leg

Reference Leg

CRD

LT

LT

Condensing Chamber

Attachment 1 IN 2002-06

______________________________________________________________________________________

OL = Operating License

CP = Construction Permit

Attachment 2 LIST OF RECENTLY ISSUED

NRC INFORMATION NOTICES

_____________________________________________________________________________________

Information

Date of

Notice No.

Subject

Issuance

Issued to

_____________________________________________________________________________________

2002-05

Foreign Material in Standby

Liquid Control Storage Tanks

01/17/02

All holders of licenses for nuclear

power reactors.

2002-04

Wire Degradation at Breaker

Cubicle Door Hinges

01/10/02

All holders of operating licenses

for nuclear power reactors.

2002-03

Highly Radioactive Particle

Control Problems During Spent

Fuel Pool Cleanout

01/10/2002

All holders of operating licenses

for nuclear power reactors, holders of licenses for

permanently shutdown facilities

with fuel onsite, and holders of

licenses for non-power reactors.

2002-02

Recent Experience with

Plugged Steam Generator

Tubes

01/08/2002

All holders of operating licenses

for pressurized-water reactors

(PWRs), except those who have

permanently ceased operations

and have certified that fuel has

been permanently removed from

the reactor.

2002-01

Metalclad Switchgear Failures

and Consequent Losses of

Offsite Power

01/08/2002

All holders of licenses for nuclear

power reactors.

2001-19

Improper Maintenance and

Reassembly of Automatic Oil

Bubblers

12/17/2001

All holders of operating licenses

for nuclear power reactors, except those who have

permanently ceased operations

and have certified that fuel has

been permanently removed from

the reactor vessel.

2001-18

Degraded or Failed Automated

Electronic Monitoring, Control,

Alarming, Response, and

Communications Needed for

Safety and/or Safeguards

12/14/2001 All uranium fuel conversion, enrichment, and fabrication

licensees and certificate holders

authorized to receive safeguards

information. Information notice is

not available to the public

because it contains safeguards

information.