ML20153G965
Person / Time
Site: Beaver Valley
Issue date: 09/22/1998
From: Jain S
DUQUESNE LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
RTR-NUREG-1394 L-98-190, NUDOCS 9809300276
Download: ML20153G965 (3)


Text

.. _ _ _ . _ m __ .. . _ . . _ _ = _ _ _ _,2._-

' l

.. o g Beave Valley Power Station Shippingport, PA 15077 00G4 l I

l SUSHIL C. JAIN (412) 393 5512 Senior Vice President Fax (724) 643-8069 Nuclear Services Nuclear Power Division September 22, 1998 L-98-190 U. S. Nuclear Regulatory Conunission Attention: Document Control Desk Washington, DC 20555-0001

Subject:

Beaver Valley Power Station, Unit No.1 Docket No. 50-334, License No. DPR-66 Emergency Response Data System (ERDS)

In accordance with the requirements of 10 CFR Part 50, Appendix E, Section l VI.3.a and NUREG-1394, Revision 1, Section 3.5, " Administrative Implementation

-Requirements," the enclosed Data Point Library (DPL) changes are being submitted.

Two(2) Beaver Valley Power Station (BVPS) Unit No.1 DPLs have undergone a change in the containment hydrogen concentration Channel 1 and Channel 2 high alarm )

setpoints (from 1% to 0.5%). These changes are currently in effect on the BVPS plant computers which provide data to the ERDS computer.

If you have any questions concerning the DPL changes, please contact Mr. Sam Hobbs, Director, Safety & Licensing Department, (412) 393-5203.

Sincerely, Sushil C. Jain lf c: Mr. D. S. Brinkman, Sr. Project Manager Mr. J. R. Jolicoeur, USNRC Incident Response Division y Mr. D. M. Kern, Sr. Resident Inspector 0 4

Mr. H. J. Miller, NRC Region I Administrator

- - " ,DillVERING. ,

9909300276 900922 -

l PDR ADOCK 05000334 'OUALlIY F PDR (g q

i i

l e i 8 a

a BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY BV1 ERDS INPUT Date: 08/24/98 n e l

Reactor Unit BV1 Data Feeder: IPC hRC ERDS Parameter H2-CONC 1 Point ID: CO201A Plant Spec Point Desc. CNMT HYDROGEN CONCENTRATION CH 1 Generic /Cond Desc. CONTAINMENT HYDROGEN CONC Anal og/ Digital . A Engr Units / Dig States t Engr Units Conve;sion: LINEAR Minimum Instr Ranget 0 Maximum Instr Ranger 10 Zero Point

Reference:

N/A Reference Point Notes: N/A PROC or SENS: S Number Of Sensors: 1 How Processed: N/A Sensor Locations: SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm / Trip SC. Points: HI A1 ARM AT 0.5%

NI Detector Power Supply Cut-off Power Level- N 'a NI Detector Power Supply Turn-on Power Levelt N/A Instrument Failure Mode LOW Temperature Compensation For DP Transmitters: N Level Reference Leg: N/A Unique System Desc.: CONTAINMENT GAS IS SAMPLED AND ANALYZED AT HYDROGEN ANALYZER H2-HY101A. HYDROGEN CONCENTRATION IS INDICATED LOCALLY AND ON THE MAIN CONTROL BOARD. H2-HY101A SENSES HYDROGEN CONCENTRATION ALTERNATELY IN STREAM 1 THE PRESSURIZER CUBICLE, THEN IN STREAM 2 THE SUCTION LINE FOR THE CONTAINMENT EVACUATION PUMP 1A (CONTAINMENT DOME). OP MANUAL CHAPTER 46, RM-150-1

e I

e *.

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY l BV1 ERDS INPUT l Date: 08/24/98 Reactor Unit BV1 Data Feeder: IPC NRC ERDS Parameter: EXTRA 22 Point ID: CO202A Plant Spec Point Desc.: CNMT HYDROGEN CONCENTRATION CH 2 Generic /Cond Desc.: CONTAINMENT HYDROGEN CONC Analog / Digital: A Engr Units / Dig States  %

Engr Units Conversion LINEAR Minimum Instr Range: 0 Maximum Instr Rangen 10 Zero Point

Reference:

N/A Reference Point Notes: N/A i

PROC or SENS: S  !

Number Of sensors: 1 How Processed: N/A Sensor Locations: SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm / Trip Set Points: HI ALARM AT 0.5%

NI Detector Power Supply Cut-off Power Leveli N/A i

NI Detector Power Supply Turn-on Power Level: N/A l Instrument Failure Moda LOW Temperature Compensation For DP Transmitters: N Level Reference Leg N/A Unique System Desc : CONTAINMENT GAS IS SAMPLED AND ANALYZED AT HYDROGEN ANALYZER H2-HY1018. HIDROGEN CONCENTRATION IS INDICATED LOCAILY AND ON THE MAIN CONTROL LDARD. H2-HY101B SENSES HYDROGEN CONCENTRATION ALTERNATELY IN STREAM 1 THE PRESSURIZER CUBICLE, THEN IN STREAM 2 THE SUCTION LINE FOR THE CONTAINMENT EVACUATION PUMP IB (CONTAINMENT DOME). OP MANUAL CHAPTER 46, RM-150-1