L-22-178, Spent Fuel Storage Cask Registration

From kanterella
(Redirected from L-22-178)
Jump to navigation Jump to search
Spent Fuel Storage Cask Registration
ML22207A858
Person / Time
Site: Beaver Valley, 07201043, 07201042
Issue date: 07/25/2022
From: Grabnar J
Energy Harbor Nuclear Corp
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation
References
L-22-178
Download: ML22207A858 (2)


Text

energy Energy Harbor Nuclear Corp.

harbor Beaver Valley Power Station P.O. Box4 Shippingport, PA 15077 John J. Grabnar 724-682-5234 Site Vice President July 25, 2022 L-22-178 10 CFR 72.212 ATTN: Document Control Desk Director, Division of Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

SUBJECT:

Beaver Valley Power Station, Unit Nos. 1 and 2 Docket No. 50-334, License No. DPR-66 Docket No. 50-412, License No. NPF-73 Docket No. 72-1043 Spent Fuel Storage Cask Registration In accordance with the registration requirements of 10 CFR 72.212(b)(2), Energy Harbor Nuclear Corp. is providing the enclosed information to register spent fuel storage casks at the Beaver Valley Power Station (BVPS) independent spent fuel storage installation.

There are no regulatory commitments contained in this letter. If there are any questions or if additional information is required, please contact Steve Sawtschenko, Manager, Regulatory Compliance and Emergency Response, at 724-682-4284.

Sincerely, I

John J. Grabnar

Attachment:

Spent Fuel Storage Cask Registration Information cc: NRC Region I Administrator NRC Resident Inspector NRC Project Manager Director BRP/DEP Site BRP/DEP Representative

Attachment L-22-178 Spent Fuel Storage Cask Registration Information Page 1 of 1 The following information is provided in accordance with 10 CFR 72.212(b)(2) for registration of the spent fuel storage casks at the Beaver Valley Power Station:

Licensee Name: Energy Harbor Nuclear Corp.

Licensee Address: Beaver Valley Power Station P.O. Box 4, Route 168 Shippingport, Pennsylvania 15077 Reactor License Number: DPR-66 (Unit No. 1), NPF-73 (Unit No. 2)

Reactor Docket Number: 50-334 (Unit No. 1), 50-412 (Unit No. 2)

Independent Spent Fuel Storage Installation Docket Number: 72-1043 Contact Name and

Title:

Steve Sawtschenko, Manager, Regulatory Compliance and Emergency Response Cask Certificate Number and Certificate of Compliance (CoC)

Amendment Number: 1042; Amendment 1 Cask Model Number: EOS-37PTH Service Date: June 30, 2022 Cask Identification Number: Dry Shielded Canister (DSC) Serial Number: BV-EOS-37PTH-15-B4H/B4L Horizontal Storage Module (HSM) Serial Number: BV-3-HSM-15 Service Date: July 8, 2022 Cask Identification Number: Dry Shielded Canister (DSC) Serial Number: BV-EOS-37PTH-16-B4H/B4L Horizontal Storage Module (HSM) Serial Number: BV-3-HSM-16 Service Date: July 14, 2022 Cask Identification Number: Dry Shielded Canister (DSC) Serial Number: BV-EOS-37PTH-17-B4H/84L Horizontal Storage Module (HSM) Serial Number: BV-3-HSM-17