Recent Identified Problems with Limitorque Motor OperatorsML031250108 |
Person / Time |
---|
Site: |
Beaver Valley, Millstone, Hatch, Monticello, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Mcguire, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Kewaunee, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Oyster Creek, Watts Bar, Hope Creek, Grand Gulf, Cooper, Sequoyah, Byron, Pilgrim, Arkansas Nuclear, Three Mile Island, Braidwood, Susquehanna, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, Limerick, North Anna, Turkey Point, River Bend, Vermont Yankee, Crystal River, Haddam Neck, Ginna, Diablo Canyon, Callaway, Vogtle, Waterford, Duane Arnold, Farley, Robinson, Clinton, South Texas, San Onofre, Cook, Comanche Peak, Yankee Rowe, Maine Yankee, Quad Cities, Humboldt Bay, La Crosse, Big Rock Point, Rancho Seco, Zion, Midland, Bellefonte, Fort Calhoun, FitzPatrick, McGuire, LaSalle, 05000000, Zimmer, Fort Saint Vrain, Shoreham, Satsop, Trojan, Atlantic Nuclear Power Plant, Skagit, Marble Hill |
---|
Issue date: |
08/19/1986 |
---|
From: |
Jordan E NRC/IE |
---|
To: |
|
---|
References |
---|
IN-86-071, NUDOCS 8608150010 |
Download: ML031250108 (4) |
|
Similar Documents at Beaver Valley, Millstone, Hatch, Monticello, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Mcguire, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Kewaunee, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Oyster Creek, Watts Bar, Hope Creek, Grand Gulf, Cooper, Sequoyah, Byron, Pilgrim, Arkansas Nuclear, Three Mile Island, Braidwood, Susquehanna, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, Limerick, North Anna, Turkey Point, River Bend, Vermont Yankee, Crystal River, Haddam Neck, Ginna, Diablo Canyon, Callaway, Vogtle, Waterford, Duane Arnold, Farley, Robinson, Clinton, South Texas, San Onofre, Cook, Comanche Peak, Yankee Rowe, Maine Yankee, Quad Cities, Humboldt Bay, La Crosse, Big Rock Point, Rancho Seco, Zion, Midland, Bellefonte, Fort Calhoun, FitzPatrick, McGuire, LaSalle, 05000000, Zimmer, Fort Saint Vrain, Shoreham, Satsop, Trojan, Atlantic Nuclear Power Plant, Skagit, Marble Hill |
---|
Category:NRC Information Notice
MONTHYEARInformation Notice 2020-02, Flex Diesel Generator Operational Challenges2020-09-15015 September 2020 Flex Diesel Generator Operational Challenges ML20225A0322020-09-0303 September 2020 NRC Choice Letter to NAC International with Attached Safety Inspection Report, IR 0721015/2020201, February 24-27, 2020 and July 22, 2020, Inspection of NAC International in Norcross, Georgia Information Notice 2012-09, PWROG-16043-NP-A, Revision 2, PWROG Program to Address NRC Information Notice 2012-09: Irradiation Effects on Fuel Assembly Spacer Grid Crush Strength for Westinghouse and CE PWR Fuel Designs.2019-11-30030 November 2019 PWROG-16043-NP-A, Revision 2, PWROG Program to Address NRC Information Notice 2012-09: Irradiation Effects on Fuel Assembly Spacer Grid Crush Strength for Westinghouse and CE PWR Fuel Designs. Information Notice 2011-20, NRC060 - NRC Information Notice 2011-20: Concrete Degradation by Alkali-Silica Reaction (Nov. 18, 2011)2019-07-24024 July 2019 NRC060 - NRC Information Notice 2011-20: Concrete Degradation by Alkali-Silica Reaction (Nov. 18, 2011) ML19196A2452019-07-15015 July 2019 Public Notice - Sequoyah Nuclear Plant, Unit 2 - Exigent Amendment to Facility Operating License Information Notice 2019-01, Inadequate Evaluation of Temporary Alterations2019-03-12012 March 2019 Inadequate Evaluation of Temporary Alterations ML16028A3082016-04-27027 April 2016 NRC Information Notice; IN 2016-05: Operating Experience Regarding Complications From a Loss of Instrumentation Air Information Notice 2015-05, Inoperability of Auxiliary and Emergency Feedwater Auto Start Circuits on Loss of Main Feedwater Pumps2015-05-12012 May 2015 Inoperability of Auxiliary and Emergency Feedwater Auto Start Circuits on Loss of Main Feedwater Pumps Information Notice 2015-05, Inoperability Of Auxiliary And Emergency Feedwater Auto Start Circuits On Loss Of Main Feedwater Pumps2015-05-12012 May 2015 Inoperability Of Auxiliary And Emergency Feedwater Auto Start Circuits On Loss Of Main Feedwater Pumps Information Notice 2013-20, OFFICIAL EXHIBIT - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143)2013-10-0303 October 2013 OFFICIAL EXHIBIT - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143) Information Notice 2013-20, Official Exhibit - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143)2013-10-0303 October 2013 Official Exhibit - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143) Information Notice 2013-11, OFFICIAL EXHIBIT - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013)2013-07-0303 July 2013 OFFICIAL EXHIBIT - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013) Information Notice 2013-11, Official Exhibit - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013)2013-07-0303 July 2013 Official Exhibit - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013) Information Notice 2010-12, Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Contain2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2010-12, Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Con2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2010-12, Intervenors' Fifth Motion to Amend And/Or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notic2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend And/Or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2012-13, Boraflex Degradation Surveillance Programs and Corrective Actions in the Spent Fuel Pool2012-08-10010 August 2012 Boraflex Degradation Surveillance Programs and Corrective Actions in the Spent Fuel Pool Information Notice 2012-13, Boraflex Degradation Surveillance Programs And Corrective Actions In The Spent Fuel Pool2012-08-10010 August 2012 Boraflex Degradation Surveillance Programs And Corrective Actions In The Spent Fuel Pool Information Notice 2012-11, Age Related Capacitor Degradation2012-07-23023 July 2012 Age Related Capacitor Degradation ML12031A0132012-02-0606 February 2012 U.S. Nuclear Regulatory Commission Investigation Report No. 2-2010-058, Cpn International, Inc Information Notice 2011-19, Licensee Event Reports Containing Information Pertaining to Defects to Basic Components2011-09-26026 September 2011 Licensee Event Reports Containing Information Pertaining to Defects to Basic Components Information Notice 2011-15, Steel Containment Degradation and Associated License Renewal Aging Management Issues2011-08-0101 August 2011 Steel Containment Degradation and Associated License Renewal Aging Management Issues Information Notice 2011-17, Calculation Methodologies for Operability Determinations of Gas Voids in Nuclear Power Plant Piping2011-07-26026 July 2011 Calculation Methodologies for Operability Determinations of Gas Voids in Nuclear Power Plant Piping Information Notice 2011-13, Official Exhibit - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13)2011-06-29029 June 2011 Official Exhibit - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13) Information Notice 2011-13, Official Exhibit - Nys000329-00-Bd01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (Nrc in 2011-13)2011-06-29029 June 2011 Official Exhibit - Nys000329-00-Bd01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (Nrc in 2011-13) Information Notice 2011-13, OFFICIAL EXHIBIT - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13)2011-06-29029 June 2011 OFFICIAL EXHIBIT - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13) Information Notice 2011-04, IN: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 IN: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2011-04, In: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 In: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2011-04, in: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 in: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2010-26, New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-2010-12-30030 December 2010 New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-19 Information Notice 2010-26, New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review2010-12-30030 December 2010 New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-19 Information Notice 2010-26, 2010/12/21-NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-262010-12-21021 December 2010 2010/12/21-NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 ML13066A1872009-12-16016 December 2009 Draft NRC Information Notice 2009-xx - Underestimate of Dam Failure Frequency Used in Probabilistic Risk Assessments ML1007804482009-11-23023 November 2009 Email from Peter Bamford, NRR to Pamela Cowan, Exelon on TMI Contamination Control Event Information Notice 2009-11, NSP000059-Revised Prefiled Testimony of Northard/Petersen/Peterson-NRC Information Notice 2009-112009-07-0707 July 2009 NSP000059-Revised Prefiled Testimony of Northard/Petersen/Peterson-NRC Information Notice 2009-11 Information Notice 2009-10, Official Exhibit - NYS000019-00-BD01- NRC Information Notice 2009-10, Transformers Failures - Recent Operating Experience (Jul. 7, 2009) (NRC in 2009-10)2009-07-0707 July 2009 Official Exhibit - NYS000019-00-BD01- NRC Information Notice 2009-10, Transformers Failures - Recent Operating Experience (Jul. 7, 2009) (NRC in 2009-10) Information Notice 2009-09, Improper Flow Controller Settings Renders Injection Systems Inoperable and Surveillance Did Not Identify2009-06-19019 June 2009 Improper Flow Controller Settings Renders Injection Systems Inoperable and Surveillance Did Not Identify Information Notice 2008-12, Reactor Trip Due to Off-Site Power Fluctuation2008-07-0707 July 2008 Reactor Trip Due to Off-Site Power Fluctuation Information Notice 2008-11, Service Water System Degradation at Brunswicksteam Electric Plant Unit 12008-06-18018 June 2008 Service Water System Degradation at Brunswicksteam Electric Plant Unit 1 Information Notice 2008-04, Counterfeit Parts Supplied to Nuclear Power Plants2008-04-0707 April 2008 Counterfeit Parts Supplied to Nuclear Power Plants Information Notice 1991-09, Counterfeiting of Crane Valves2007-09-25025 September 2007 Counterfeiting of Crane Valves Information Notice 2007-28, Potential Common Cause Vulnerabilities in Essential Service Water Systems Due to Inadequate Chemistry Controls2007-09-19019 September 2007 Potential Common Cause Vulnerabilities in Essential Service Water Systems Due to Inadequate Chemistry Controls Information Notice 2007-29, Temporary Scaffolding Affects Operability of Safety-Related Equipment2007-09-17017 September 2007 Temporary Scaffolding Affects Operability of Safety-Related Equipment Information Notice 2007-14, Loss of Offsite Power and Dual-Unit Trip at Catawba Nuclear Generating Station2007-03-30030 March 2007 Loss of Offsite Power and Dual-Unit Trip at Catawba Nuclear Generating Station Information Notice 2007-06, Potential Common Cause Vulnerabilities in Essential Service Water Systems2007-02-0909 February 2007 Potential Common Cause Vulnerabilities in Essential Service Water Systems Information Notice 2007-05, Vertical Deep Draft Pump Shaft and Coupling Failures2007-02-0909 February 2007 Vertical Deep Draft Pump Shaft and Coupling Failures Information Notice 2006-31, Inadequate Fault Interrupting Rating of Breakers2006-12-26026 December 2006 Inadequate Fault Interrupting Rating of Breakers Information Notice 2006-29, Potential Common Cause Failure of Motor-operated Valves as a Result of Stem Nut Wear2006-12-14014 December 2006 Potential Common Cause Failure of Motor-operated Valves as a Result of Stem Nut Wear Information Notice 2006-29, Potential Common Cause Failure of Motor-operated Valves As a Result of Stem Nut Wear2006-12-14014 December 2006 Potential Common Cause Failure of Motor-operated Valves As a Result of Stem Nut Wear Information Notice 2006-13, E-mail from M. Mclaughlin on NRC, Regarding NRC Information Notice 2006-13: Groundwater Contamination2006-07-13013 July 2006 E-mail from M. Mclaughlin on NRC, Regarding NRC Information Notice 2006-13: Groundwater Contamination 2020-09-03 The following query condition could not be considered due to this wiki's restrictions on query size or depth: <code> [[:Beaver Valley]] OR [[:Millstone]] OR [[:Hatch]] OR [[:Monticello]] OR [[:Calvert Cliffs]] OR [[:Dresden]] OR [[:Davis Besse]] OR [[:Peach Bottom]] OR [[:Browns Ferry]] OR [[:Salem]] OR [[:Oconee]] OR [[:Mcguire]] OR [[:Nine Mile Point]] OR [[:Palisades]] OR [[:Palo Verde]] OR [[:Perry]] OR [[:Indian Point]] OR [[:Fermi]] OR [[:Kewaunee]] OR [[:Catawba]] OR [[:Harris]] OR [[:Wolf Creek]] OR [[:Saint Lucie]] OR [[:Point Beach]] OR [[:Oyster Creek]] OR [[:Watts Bar]] OR [[:Hope Creek]] OR [[:Grand Gulf]] OR [[:Cooper]] OR [[:Sequoyah]] OR [[:Byron]] OR [[:Pilgrim]] OR [[:Arkansas Nuclear]] OR [[:Three Mile Island]] OR [[:Braidwood]] OR [[:Susquehanna]] OR [[:Summer]] OR [[:Prairie Island]] OR [[:Columbia]] OR [[:Seabrook]] OR [[:Brunswick]] OR [[:Surry]] OR [[:Limerick]] OR [[:North Anna]] OR [[:Turkey Point]] OR [[:River Bend]] OR [[:Vermont Yankee]] OR [[:Crystal River]] OR [[:Haddam Neck]] OR [[:Ginna]] OR [[:Diablo Canyon]] OR [[:Callaway]] OR [[:Vogtle]] OR [[:Waterford]] OR [[:Duane Arnold]] OR [[:Farley]] OR [[:Robinson]] OR [[:Clinton]] OR [[:South Texas]] OR [[:San Onofre]] OR [[:Cook]] OR [[:Comanche Peak]] OR [[:Yankee Rowe]] OR [[:Maine Yankee]] OR [[:Quad Cities]] OR [[:Humboldt Bay]] OR [[:La Crosse]] OR [[:Big Rock Point]] OR [[:Rancho Seco]] OR [[:Zion]] OR [[:Midland]] OR [[:Bellefonte]] OR [[:Fort Calhoun]] OR [[:FitzPatrick]] OR [[:McGuire]] OR [[:LaSalle]] OR [[:05000000]] OR [[:Zimmer]] OR [[:Fort Saint Vrain]] OR [[:Shoreham]] OR [[:Satsop]] OR [[:Trojan]] OR [[:Atlantic Nuclear Power Plant]] OR [[:Skagit]] OR [[:Marble Hill]] </code>.
[Table view]The following query condition could not be considered due to this wiki's restrictions on query size or depth: <code> [[:Beaver Valley]] OR [[:Millstone]] OR [[:Hatch]] OR [[:Monticello]] OR [[:Calvert Cliffs]] OR [[:Dresden]] OR [[:Davis Besse]] OR [[:Peach Bottom]] OR [[:Browns Ferry]] OR [[:Salem]] OR [[:Oconee]] OR [[:Mcguire]] OR [[:Nine Mile Point]] OR [[:Palisades]] OR [[:Palo Verde]] OR [[:Perry]] OR [[:Indian Point]] OR [[:Fermi]] OR [[:Kewaunee]] OR [[:Catawba]] OR [[:Harris]] OR [[:Wolf Creek]] OR [[:Saint Lucie]] OR [[:Point Beach]] OR [[:Oyster Creek]] OR [[:Watts Bar]] OR [[:Hope Creek]] OR [[:Grand Gulf]] OR [[:Cooper]] OR [[:Sequoyah]] OR [[:Byron]] OR [[:Pilgrim]] OR [[:Arkansas Nuclear]] OR [[:Three Mile Island]] OR [[:Braidwood]] OR [[:Susquehanna]] OR [[:Summer]] OR [[:Prairie Island]] OR [[:Columbia]] OR [[:Seabrook]] OR [[:Brunswick]] OR [[:Surry]] OR [[:Limerick]] OR [[:North Anna]] OR [[:Turkey Point]] OR [[:River Bend]] OR [[:Vermont Yankee]] OR [[:Crystal River]] OR [[:Haddam Neck]] OR [[:Ginna]] OR [[:Diablo Canyon]] OR [[:Callaway]] OR [[:Vogtle]] OR [[:Waterford]] OR [[:Duane Arnold]] OR [[:Farley]] OR [[:Robinson]] OR [[:Clinton]] OR [[:South Texas]] OR [[:San Onofre]] OR [[:Cook]] OR [[:Comanche Peak]] OR [[:Yankee Rowe]] OR [[:Maine Yankee]] OR [[:Quad Cities]] OR [[:Humboldt Bay]] OR [[:La Crosse]] OR [[:Big Rock Point]] OR [[:Rancho Seco]] OR [[:Zion]] OR [[:Midland]] OR [[:Bellefonte]] OR [[:Fort Calhoun]] OR [[:FitzPatrick]] OR [[:McGuire]] OR [[:LaSalle]] OR [[:05000000]] OR [[:Zimmer]] OR [[:Fort Saint Vrain]] OR [[:Shoreham]] OR [[:Satsop]] OR [[:Trojan]] OR [[:Atlantic Nuclear Power Plant]] OR [[:Skagit]] OR [[:Marble Hill]] </code>. |
LI S P161 SSINS NO.
IN 86-71 6835 UNITED STATES
NUCLEAR REGULATORY COMMISSION
OFFICE OF INSPECTION AND ENFORCEMENT
WASHINGTON, D.C. 20555 August 19, 1986 IE INFORMATION NOTICE NO. 86-71: RECENT IDENTIFIED PROBLEMS WITH
LIMITORQUE MOTOR OPERATORS
Addressees
All nuclear power reactor facilities holding an operating license or a
construction permit.
Purpose
This notice is provided to alert recipients of two potential problems discovered
with Limitorque motor operators. It is expected that recipients will review this
information for applicability to their facilities and consider actions, if
appropriate, 'to preclude a similar problem from occurring at their facilities.
However, suggestions contained in this notice do not constitute NRC requirements;
therefore, no specific action or written response is required.
Past Related Documents:
IE Information Notice 86-03 "Potential Deficiencies in Environmental Qualification
of Limitorque Motor Valve Operator Wiring," January 14, 1986.
Description of Circumstances
- Burn Damage to Internal Wiring
On November 8, 1985 Georgia Power Company submitted a preliminary report to the
NRC indicating that it had discovered burn damage to internal wiring in several
Limitorque motor operators installed in their Vogtle Unit 1 Power Plant.
Evidence suggested the burn damage had been caused by electric heater elements
installed in the limit switch compartment for storage purposes within certain
types of Limitorque motor operators.
On March 20, 1986 Georgia Power Company submitted a final report to the NRC
which suggested that the burn damage was a generic problem applicable to all
Limitorque motor operators. This assumption was based on a sampling inspection
of 104 Limitorque motor operators installed in Vogtle Unit 1. Forty-six of the
motor operators examined were Limitorque type SMB-000, and six of these were
found to have burnt internal wiring. Out of the 58 operators other than type
SMB-OOO which were inspected, 5 were found to contain wires deemed susceptible
to damage because of their close proximity to the heater elements (less than
h inch).
8608150010
IN 86-71 August 19, 1986 On May 20, 1986 an NRC inspector, along with Limitorque, Georgia Power, and
Bechtel personnel, performed a random inspection on four type SMB-000 operators
installed in Vogtle Unit 2. Three of the four operators were found to contain
burnt internal wiring. One type SMB-OO operator also was inspected and was
found to contain wiring susceptible to damage.
Discussion:
The wiring in question is Limitorque installed internal wiring located in the
operator limit switch compartment. The wiring is being burnt as a result of
its close proximity to, or contact with, the installed limit switch compartment
electric heater element or heater bracket. The wiring is not properly routed
and is not restrained from contacting the heater or heater bracket. Although
the heater is not a seismically or environmentally qualified part and is intended
for use only during storage, its use has been shown to cause serious degradation
of environmentally qualified internal wiring.
The burnt wiring has been discovered only in Limitorque type SMB-OOO motor
operators that contain previously energized heaters, although any Limitorque
operator that contains a previously energized heater could possibly exhibit a
similar problem.
Description of Circumstances
- Cracked Limit Switch Rotors
Several licensees have submitted reports to the NRC concerning a problem with
cracked limit switch rotors on Limitorque motor operators installed inside and
outside of containment. The limit switches are used for control of the motor
operator and also provide indication of valve position in the control room.
The cracks have been found on white melamine limit switch rotors. Most of these
cracks were found in the area where the limit switch rotors are pinned-to the
pinion shafts. Some cracks have been found to extend halfway through the
melamine rotors, weakening them to the extent that they are easily broken.
Discussion:
In its letter dated February 21, 1984 to the Westinghouse Electric Corporation, Electro Mechanical Division, Cheswick, Pennsylvania, Limitorque recommended
that any white limit switch components which are found with cracks should be
replaced with components manufactured with a later design, brown colored material.
Violations of 10 CFR Part 21 have been issued to Limitorque for failure to report
and for failure to evaluate defects discovered in their motor operators. Licensees
are reminded of their responsibility to ensure that procurement documents include
a contractual requirement that the provisions of 10 CFR Part 21 apply (when
applicable) and that Criterion VII of 10 CFR Part 50 Appendix B requires that
purchased material, equipment, and services conform to the requirements of the
procurement documents.
IN 86-71 August 19, 1986 No specific action or written response is required by this information notice.
If you have any questions about this matter, please contact the Regional Admin- istrator of the appropriate NRC regional office or this office.
Edward L. 4ordan, Director
Division Xf Emergency Preparedness
and Eng neering Response
Office of Inspection and Enforcement
Technical Contact:
Jeffrey Jacobson, IE
(301) 492-8845 Attachment: List of Recently Issued IE Information Notices
Attachment 1 IN 86-71 August 19, 1986 LIST OF RECENTLY ISSUED
IE INFORMATION NOTICES
Information Date of
Notice No. Subject Issue Issued to
86-70 Spurious System Isolation 8/18/86 All GE BWR facilities
Caused By The Panalarm Model holding an OL or CP
86 Thermocouple Monitor
86-69 Scram Solenoid Pilot Valve 8/18/86 All BWR facilities
(SSPV) Rebuild Kit Problems holding an OL or CP
86-68 Stuck Control Rod 8/15/86 All BWR facilities
holding an OL or CP
86-67 Portable Moisture/Density 8/15/86 All NRC licensees
Gauges: Recent Incidents And authorized to possess, Common Violations Of Require- use, transport, and
ments For Use, Transportation, store sealed sources
And Storage
86-66 Potential For Failure Of 8/15/86 All power reactor
Replacement AC Coils Supplied facilities holding
By The Westinghouse Electric an OL or CP
Corporation For Use In Class
lE Motor Starters And
Contractors
86-65 Malfunctions Of ITT Barton 8/14/86 All power reactor
Model 580 Series Switches facilities holding
During Requalification Testing an OL or CP
86-64 Deficiencies In Upgrade 8/14/86 All power reactor
Programs For Plant Emergency facilities holding
Operating Procedures an OL or CP
86-63 Loss Of Safety Injection 8/6/86 All PWR facilities
Capability holding an OL or CP
86-62 Potential Problems In West- 7/31/86 All power reactor
inghouse Molded Case Circuit facilities holding
Breakers Equipped With A an OL or CP
Shunt Trip
OL = Operating License
CP = Construction Permit
|
---|
|
list | - Information Notice 1986-01, Failure of Main Feedwater Check Valves Causes Loss of Feedwater System Integrity and Water-Hammer Damage (6 January 1986)
- Information Notice 1986-02, Failure of Valve Operator Motor During Environmental Qualification Testing (6 January 1986)
- Information Notice 1986-03, Potential Deficiencies in Enviromental Qualification of Limitorque Motor Valve Operator Wiring (14 January 1986)
- Information Notice 1986-04, Transient Due to Loss of Power to Intergrated Control System at a Pressurized Water Reactor Designed by Babcock & Wilcox (31 January 1986)
- Information Notice 1986-05, Main Steam Safety Valve Test Failures and Ring Setting Adjustments (31 January 1986)
- Information Notice 1986-06, Failure of Lifting Rig Attachment, While Lifting Upper Guide Structure at St. Lucie Unit 1 (3 February 1986, Topic: Control of Heavy Loads)
- Information Notice 1986-06, Failure of Lifting Rig Attachment, while Lifting Upper Guide Structure at St. Lucie Unit 1 (3 February 1986)
- Information Notice 1986-07, Lack of Detailed Instruction & Inadequate Observance of Precautions During Maintenance & Testing of Diesel Generator Woodward Governors (3 February 1986)
- Information Notice 1986-08, Licensee Event Report (LER) Format Modification (3 February 1986)
- Information Notice 1986-09, Failure of Check & Stop Check Valves Subjected to Low Flow Conditions (3 February 1986)
- Information Notice 1986-10, Degradation of Reactor Coolant System Pressure Boundary Resulting From Boric Acid Corrosion. (5 January 1995, Topic: Boric Acid, Stress corrosion cracking)
- Information Notice 1986-10, Feedwater Line Break (10 November 1988, Topic: Coatings, Anchor Darling)
- Information Notice 1986-10, Degradation of Reactor Coolant System Pressure Boundary Resulting from Boric Acid Corrosion. (5 January 1995, Topic: Boric Acid, Stress corrosion cracking)
- Information Notice 1986-11, Anomalous Behavior of Recirculation Loop Flow in Jet Pump BWR Plants (31 December 1986)
- Information Notice 1986-13, Standby Liquid Control System Squib Valves Failure to Fire (21 February 1986, Topic: Squib)
- Information Notice 1986-13, Standby Liquid Control Squib Valves Failure to Fire (5 August 1986, Topic: Squib)
- Information Notice 1986-14, Overspeed Trips of AFW, HPCI & RCIC Turbines (26 August 1991, Topic: Fire Barrier)
- Information Notice 1986-14, Overspeed Trips of Afw, HPCI & RCIC Turbines (26 August 1991)
- Information Notice 1986-15, Loss of Offsite Power Caused by Problems in Fiber Optics Systems (10 March 1986, Topic: Squib)
- Information Notice 1986-16, Failures to Identify Containment Leakage Due to Inadequate Local Testing of BWR Vacuum Relief System Valves (11 March 1986, Topic: Squib)
- Information Notice 1986-17, Update of Failure of Automatic Sprinkler System Valves to Operate (24 March 1986, Topic: Squib)
- Information Notice 1986-18, NRC On-Scene Response During a Major Emergency (26 March 1986, Topic: Squib, Backfit)
- Information Notice 1986-19, Reactor Coolant Pump Shaft Failure at Crystal River (21 March 1986, Topic: Squib)
- Information Notice 1986-20, Low-Level Radioactive Waste Scaling Factors, 10 CFR Part 61 (28 March 1986, Topic: Squib)
- Information Notice 1986-21, Recognition of American Society of Mechanical Engineers Accreditation Program for N Stamp Holders (31 March 1986, Topic: Squib)
- Information Notice 1986-22, Underresponse of Radiation Survey Instrument to High Radiation Fields (31 March 1986, Topic: High Radiation Area, Squib)
- Information Notice 1986-23, Excessive Skin Exposures Due to Contamination with Hot Particles (9 April 1986)
- Information Notice 1986-23, Excessive Skin Exposures due to Contamination with Hot Particles (9 April 1986)
- Information Notice 1986-24, Respirator Users Notice: Increased Inspection Frequency for Certain Self-Contained Breathing Apparatus Air Cylinders (11 April 1986, Topic: Hydrostatic)
- Information Notice 1986-25, Traceability and Material Control of Material and Equipment, Particularly Fasteners (11 April 1986)
- Information Notice 1986-26, Potential Problems in Generators Manufactured by Electrical Products Incorporated (17 April 1986)
- Information Notice 1986-27, Access Control at Nuclear Facilities (21 April 1986, Topic: Contraband)
- Information Notice 1986-28, Telephone Numbers to the NRC Operations Center and Regional Offices (24 April 1986)
- Information Notice 1986-29, Effects of Changing Valve Moter-Operator Switch Settings (25 April 1986)
- Information Notice 1986-30, Design Limitations of Gaseous Effluent Monitoring Systems (29 April 1986)
- Information Notice 1986-31, Unauthorized Transfer and Loss of Control of Industrial Nuclear Gauges (14 July 1986)
- Information Notice 1986-32, Request for Collection of Licensee Radioactivity Measurements Attributed to Chernobyl Nuclear Plant Accident (2 May 1986, Topic: Chernobyl)
- Information Notice 1986-33, Information for Licensee Regarding the Chernobyl Nuclear Plant Accident (6 May 1986, Topic: Chernobyl)
- Information Notice 1986-34, Improper Assembly, Material Selection, & Test of Valves & Their Actuators (13 May 1986)
- Information Notice 1986-34, Improper Assembly, Material Selection, & Test of Valves & their Actuators (13 May 1986)
- Information Notice 1986-35, Fire in Compressible Material at Dresden Unit 3 (15 May 1986, Topic: Chernobyl)
- Information Notice 1986-36, Change in NRC Practice Regarding Issuance of Confirming Letters to Principal Contractors (16 May 1986, Topic: Chernobyl)
- Information Notice 1986-37, Degradation of Station Batteries (16 May 1986, Topic: Chernobyl)
- Information Notice 1986-38, Deficient Operator Actions Following Dual Function Valve Failures (20 May 1986, Topic: Chernobyl)
- Information Notice 1986-39, Failures of RHR Pump Motors and Pump Internals (20 May 1986, Topic: Chernobyl)
- Information Notice 1986-40, Degraded Ability to Isolate the Reactor Coolant System from Low-Pressure Coolant Systems in Bwrs (5 June 1986, Topic: Chernobyl)
- Information Notice 1986-40, Degraded Ability to Isolate the Reactor Coolant System from Low-Pressure Coolant Systems in BWRs (5 June 1986, Topic: Chernobyl)
- Information Notice 1986-41, Evaluation of Questionable Exposure Readings of Licensee Personnel Dosimeters (9 June 1986, Topic: Chernobyl)
- Information Notice 1986-42, Improper Maintenance of Radiation Monitoring Systems (9 June 1986, Topic: Temporary Modification, Chernobyl)
- Information Notice 1986-43, Problems with Silver Zeolite Sampling of Airborne Radioiodine (10 June 1986, Topic: Chernobyl)
... further results |
---|