Commercial Grade Dedication Report 05000528/2023012 and 05000529/2023012 and 05000530/2023012 (1)
ML23291A089
Person / Time
Site: Palo Verde  
(NPF-041, NPF-051, NPF-074)
Issue date: 10/23/2023
From: Vincent Gaddy
NRC/RGN-IV/DORS/EB1
To: Heflin A
Arizona Public Service Co
References
IR 2023012
Download: ML23291A089 (8)


Text

October 23, 2023

SUBJECT:

PALO VERDE NUCLEAR GENERATING STATION - COMMERCIAL GRADE DEDICATION REPORT 05000528/2023012 AND 05000529/2023012 AND 05000530/2023012

Dear Adam Heflin:

On September 28, 2023, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Palo Verde Nuclear Generating Station and discussed the results of this inspection with John Hernandez, Vice President, Site Services and other members of your staff. The results of this inspection are documented in the enclosed report.

No findings or violations of more than minor significance were identified during this inspection.

This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.

Sincerely, Vincent G. Gaddy, Chief Engineering Branch 1 Division of Operating Reactor Safety Docket Nos. 05000528 and 05000529 and 05000530 License Nos. NPF-41 and NPF-51 and NPF-74

Enclosure:

As stated

Inspection Report

Docket Numbers:

05000528, 05000529 and 05000530

License Numbers:

NPF-41, NPF-51 and NPF-74

Report Numbers:

05000528/2023012, 05000529/2023012 and 05000530/2023012

Enterprise Identifier:

I-2023-012-0004

Licensee:

Arizona Public Service

Facility:

Palo Verde Nuclear Generating Station

Location:

Tonopah, AZ

Inspection Dates:

September 11, 2023 to September 29, 2023

Inspectors:

W. Cullum, Senior Reactor Inspector

C. Franklin, Reactor Inspector

D. Reinert, Senior Reactor Inspector

Approved By:

Vincent G. Gaddy, Chief

Engineering Branch 1

Division of Operating Reactor Safety

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting a Commercial Grade Dedication at Palo Verde Nuclear Generating Station, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors.

Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.

List of Findings and Violations

No findings or violations of more than minor significance were identified.

Additional Tracking Items

None.

INSPECTION SCOPES

Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.

REACTOR SAFETY

71111.21N.03 - Commercial Grade Dedication Commercial Grade Dedication (section 03.01)

The inspectors reviewed the implementation of the licensees processes for dedicating commercial-grade items/services as basic components and/or for procuring safety-related structures, systems, and components for the following samples:

(1) APN 66773 - Meter - Valve Position Indicator For Containment Spray Valve 3JSIAZI672
(2) APN 73268 - Filter - Oil Filter for Charging Pump E 1MCHEP01**PUMPXX
(3) APN 76400 - Belzona - Coating for internal surface of Diesel Generator B Air Intercooler 2MDGBE01A**HTEXCH
(4) APN 00165399 - Screw - Screw fastener mounting for Diesel Generator B Overspeed Fuel Trip Solenoid Valve 1JDGBUV0238**VALVEX
(5) APN 84882 - Gauge - Gauge for Charging Pump Lube Oil Pressure Indicator 1JCHAPI0056
(6) APN 00127849 - Integrated Circuit - Optical Isolator on Remote Gate Firing Module in the Diesel Generator Voltage Regulator 3JDGAB02**INSTRU
(7) APN 89233 - Flow Meter - Flow Meter for Control Room Air Intake Radiation Monitor 1JSQARU0029
(8) APN 44930900 - Terminal Block - Electrical Terminal Block for Safety Injection Tank 1A Narrow Range Pressure 3JSIAPT0333
(9) APN 162423 - Monitor - Xycom Status Display for Diverse Auxiliary Feedwater Actuation System (DAFAS) 2JSAAC05
(10) APN 16536 - Lube Oil - Stem Lubricating Grease for Containment Isolation Valve 3PAFBV524
(11) APN 43900053 - Lube - Dow Silicones Corp. Molykote 41 Grease for Containment Purge Isolation Valve 2JCPAUV0002A
(12) APN 44510268 - Relay - Industrial Control 125 VDC 4 Pole for Emergency Diesel Generator A 1EPEAG01
(13) APN 44011367 - Printed Circuit Board, Controller for Containment Area Radiation Monitor 3JSQARI0148
(14) APN 45002175 - Valve - Solenoid 3-Way for Emergency Diesel Generator A 3JDGAB01**INSTRU
(15) APN 00165717 - Valve - Pressure and Vacuum Breather for Condensate Storage Tank 1JCTNPSV0008 & 1JCTNPSV0023

INSPECTION RESULTS

No findings were identified.

EXIT MEETINGS AND DEBRIEFS

The inspectors verified no proprietary information was retained or documented in this report.

  • On September 28, 2023, the inspectors presented the Commercial Grade Dedication results to John Hernandez, Vice President, Site Services and other members of the licensee staff.

DOCUMENTS REVIEWED

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

Corrective Action

Documents

CR-

17-17289, 20-09615, 21-00099, 21-06680, 19-16155, 21-

05171, 22-10235, 22-10630, 23-02102, 23-02160, 21-

04688, 23-05675, 17-06581, 20-15688, 20-16508, 13-

01496, 22-00263, 21-14872, 21-04989, 22-03262

Corrective Action

Documents

Resulting from

Inspection

CR-

23-09301, 23-09304, 23-09361, 23-09409, 23-09492, 23-

09583, 23-09699, 23-09705, 23-09809

20-08051-001

Filter Assembly

21-04989-005

Evaluation New Model Vacuum Breather Valves

Engineering

Evaluations

23-05675-001

Evaluation of Oconee Q Paperwork for Molykote 41

IPS-K020-020

Karman RIC Controller - Item Procurement Specification

ITTE-MEE 02509

Dedication Requirements of Protective Barrier Coatings

for NON-DBA Tested Safety Related Use At PVNGS

MEE-01005

Terminal Block (Strip) Item Type Technical Evaluation

MEE-01006

Relay (Electro-Mechanical) - Item Type Technical

Evaluation

MEE-01012

Lubricant (Oil, Grease) Item Type Technical Evaluation

MEE-01020

Meters - Item Type Technical Evaluation

MEE-01024

Integrated Circuits Item Type Technical Evaluation

MEE-01026

Filters - Item Type Technical Evaluation

MEE-01029

Eternal Fasteners Item Type Technical Evaluation

71111.21N.03

Miscellaneous

MEE-01041

Globe Valve - Item Type Technical Evaluation

MEE-01070

Pressure and Differential Gauges Item Type Technical

Evaluation

71111.21N.03

Miscellaneous

MEE-01157

Flow Indicator Item Type Technical Evaluation

MEE-02378

ASCO Solenoid Valve - Item Type Technical Evaluation

MEE-03590

Electro-Luminescent Video Display Terminal Item Type

Technical Evaluation

MEE-04377

Substitution Evaluation of Integrated Circuit

Purchase Orders

(PO)

500571671, 500521881, 500542372, 500643080,

500651745, 500642016, 500297484, 500623627,

500628518, 500651076, 500638258

2DP-0MC25

Stores

2DP-0MC29

Warehouse Discrepancy Notice (WDN)

2DP-0MC46

Receipt Inspection

64DP-0QQ09

Supplier Source Verification

87DP-0MC09

Item Procurement Specification (IPS) Requirements

Procedures

87DP-0MC39

Commercial Grade Dedication (CGD) Process

Work Orders

4863419, 5262440, 5334174, 5374990, 5377145,

0005260676, 0004972121, 5081098, 5467588,

0005391992, 5087390, 5298332, 4636040, 5339150,

5404057, 5432029, 5554508