_
__
UNITED ST ATES l
g* 88 O Y,
gig NUCLEAR REGULATORY COMMISSION
!
f
,
^* I o
REGloN IV
!
611 RYAN PLAZA DRIVE, SUITE 400 o%,,
,#
AR tiNcTow. t ExAS 7soti 8064 l
,
tm 2 31993
!
Dockets: 50-498 50-499
'
Licenses: NPF-76 l
+
!
Houston _ Lighting & Power Company ATTN: William T. Cottle, Group Vice President, Nuclear i
P.O. Box 289 Wadsworth, Texas 77483 l
SUBJECT: NRC INSPECTION REPORT 50-498/93-16; 50-499/93-16
.
Thank you for your letter of July 9,1993, in response to our letter i
dated May 7, 1993. We have reviewed your reply and find it' responsive to the
,
i concerns raised in NRC Inspection Report _50-498/93-16; 50-499/93-16. We will
.
review the implementation of your corrective actions during a future I
-
inspection to determine that full compliance has been achieved and will be j
maintained.
i P
Sincerely,
-
Dwi ht D. Chamberlain Acting Director Division of Radiation Safety and Safeguards cc:
Houston Lighting & Power Company ATTN: James J. Sheppard, General Manager Nuclear Licensing P.O. Box 289 Wadsworth, Texas 77483 I
r 9312030059 931123
-[/ '
PDR ADOCK 05000498
.
G PDR,
.-
i
___..
_
.. _
_.
_
_.
. ~ _.. _ _
...
.
.
!
-
.
.
Houston Lighting &
-2-Power Company City of Austin
Electric Utility Department j
ATTN:
J. C. Lanier/M. B.' Lee i
721 Barton Springs Road j
City Public Service Board l
ATTN:
K. J. Fiedler/M. T. Hardt
P.O. Box 1771
!
San Antonio, Texas 78296
!
I Newman & Holtzinger, P. C.
!
ATTN: Jack R. Newman, Esq.
!
1615 L Street, NW l
Washington, D.C.-
20036
!
r Central Power and Light Company
!
l ATTN:
G. E. Vaughn/T. M. Puckett j
P.O. Box 2121 i
'
Corpus Christi, Texas 78403 i
I
!
Records Center
!
i 700 Galleria Parkway I
Atlanta, Georgia 30339-5957 l
l
!
Mr. Joseph M. Hendrie t
50 Bellport Lane
'
Bellport, New York 11713
!
Bureau of Radiation Control i
State of Texas l
1100 West 49th Street
,
t j
Judge, Matagorda County i
Matagorda County Courthouse i
'
1700 Seventh Street Bay City, Texas 77414 Licensing Representative Houston Lighting & Power Company Suite 610 Three Metro Center Bethesda, Maryland 20814 Houston Lighting & Power Company ATTN: Rufus S. Scott, Associate General Counsel P.O. Box 61867 Houston, Texas 77208 l
,.
,
__
. -.
-.
.
-
._
__
.. _ -
_
_
_.
_
__
,
l
.
\\
'
'
.
Houston Lighting &
-3-
. Power Company.
(DMBI(IE04);XJ
!
bec w/ copy of letter dated July 9,1993:
l J. L. Milhoan i
South Texas Resident Inspector l
T. W. Dexter, FIPS A. B. Earnest, FIPS Section Chief (DRP/A)
l Project Engineer (DRP/A)
I Section Chief (DRP/TSS)
-
!
Lisa Shea, RM/ALF, MS: MNBB 4503 l
R. Bachmann, 0GC, MS:
15-B-18
{
MIS System l
FIPS File
!
RIV File
'-
R. Bachmann OGC, MS: 15-B-18 R. A. Scarano, RV/DRSS
l
!
,
!
I
~
!.;
I
!
.
.
!
l l
,
.
!
!
i
- /
RIV:F N C:FIPS Y
AD:DRSSb ABddstTnh BMurrg ChDChamberlain j
// /22/93 kh/kN/93 (l/22/93
!
i
,
i l
29 IC4
!
t
.
.
..
.
-
.
tiousto'n Lighting &
-3-Power Company DMB (IE04)
bec w/ copy of letter dated July 9,1993:
'
J. L. Milhoan South Texas Resident Inspector T. W. Dexter, FIPS A. B. Earnest, FIPS
'
Section Chief (DRP/A)
Project Engineer (DRP/A)
Section Chief (DRP/TSS)
Lisa Shea, RM/ALF, MS: MNBB 4503 R. Bachmann, 0GC, MS:
15-B-18 MIS System FIPS File RIV File R. Bachmann, OGC, MS: 15-B-18 R. A. Scarano, RV/DRSS i
l l
h/
M AD:DRSSh8 RIV:F4Udf[
C:FIPS AB[IdstTnh BMurcaf hDChamberlain u /f)/93 h/hf/93 (( /22/93
,
,