August 28, 2017
SUBJECT:
UPDATED INSPECTION PLAN FOR RIVER BEND STATION (REPORT 05000458/2017005)
Dear Mr. Maguire:
The enclosed inspection plan lists the inspections scheduled through June 30, 2019, for River Bend Station. The U.S. Nuclear Regulatory Commission (NRC) provides the inspection plan to allow for the resolution of any scheduling conflicts and personnel availability issues. Routine inspections performed by resident inspectors are not included in the inspection plan. The inspections listed during the last twelve months of the inspection plan are tentative and may be revised. The NRC will contact you as soon as possible to discuss changes to the inspection plan should circumstances warrant any changes. This inspection plan does not include the plan for security-related inspections, which will be sent via separate, non-publicly available correspondence.
In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390 of the NRCs Rules of Practice, a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
Please contact me at 817-200-1144 with any questions you have regarding this letter.
Sincerely,
/RA/
Jason W. Kozal, Chief Division of Reactor Projects UNITED STATES NUCLEAR REGULATORY COMMISSION
REGION IV
1600 E. LAMAR BLVD ARLINGTON, TX 76011-4511 Docket No. 50-458 License No. NPF-47 Enclosure:
Inspection Plan for River Bend Station
SUNSI Review:
ADAMS:
Non-Publicly Available Non-Sensitive Keyword:
By: CHY/dll Yes No Publicly Available Sensitive NRC-002 OFFICE BC:DRP/C NAME JKozal SIGNATURE
/RA/
DATE 8/28/17
Report 22 Unit Number Planned Dates Start End Inspection Activity Title No. of Staff on Site River Bend Inspection / Activity Plan 07/01/2017 - 06/30/2019 Page 1 of 2 08/25/2017 08:23:40 RS 8
- RAD SAFETY 08
1 IP Radioactive Solid Waste Processing and Radioactive Material Handling, Storage, and Transportation 71124.08 07/24/2017 07/28/2017 RS 5678
- RS TEAM
1 IP Radiation Monitoring Instrumentation 71124.05 08/21/2017 08/25/2017
IP Radioactive Gaseous and Liquid Effluent Treatment 71124.06 08/21/2017 08/25/2017
IP Radiological Environmental Monitoring Program 71124.07 08/21/2017 08/25/2017 EB1-07T
- RBS HEAT SINK PERFORMANCE
1 IP Heat Sink Performance 7111107T 09/18/2017 09/22/2017 EXAM
- INITIAL EXAM
1 INITIAL EXAM RB(6/18)
X02622 06/25/2018 06/29/2018
INITIAL EXAM RB(6/18)
X02622 07/23/2018 07/27/2018 RS 24
- RAD SAFETY
1 IP Occupational ALARA Planning and Controls 71124.02 01/22/2018 01/26/2018
IP Occupational Dose Assessment 71124.04 01/22/2018 01/26/2018 EB2-02
- LICENSE RENEWAL INSPECTION
1 IP License Renewal Inspection 71002 03/05/2018 03/09/2018
IP License Renewal Inspection 71002 03/19/2018 03/23/2018 EP-1
- EP EXERCISE INSPECTION
1 IP Exercise Evaluation 7111401 06/25/2018 06/29/2018
IP Emergency Action Level and Emergency Plan Changes 7111404 06/25/2018 06/29/2018
IP Drill/Exercise Performance 71151-EP01 06/25/2018 06/29/2018
IP ERO Readiness 71151-EP02 06/25/2018 06/29/2018
IP Alert & Notification System Reliability 71151-EP03 06/25/2018 06/29/2018 BRQ
- BRQ
1 IP Licensed Operator Requalification Program 7111111B 08/27/2018 08/31/2018 EB1-17T
- RBS 50.59 CHANGES, TESTS, EXPERIMENTS
1 IP Evaluations of Changes, Tests, and Experiments 7111117T 09/10/2018 09/14/2018 RS 13PI
- RAD SAFETY
1 IP Radiological Hazard Assessment and Exposure Controls 71124.01 11/05/2018 11/09/2018
IP In-Plant Airborne Radioactivity Control and Mitigation 71124.03 11/05/2018 11/09/2018
IP Occupational Exposure Control Effectiveness 71151-OR01 11/05/2018 11/09/2018
IP RETS/ODCM Radiological Effluent Occurrences 71151-PR01 11/05/2018 11/09/2018 This report does not include INPO and OUTAGE activities.
This report shows only on-site and announced inspection procedures.
Report 22 Unit Number Planned Dates Start End Inspection Activity Title No. of Staff on Site River Bend Inspection / Activity Plan 07/01/2017 - 06/30/2019 Page 2 of 2 08/25/2017 08:23:40 PI&R
- BIENNIAL PI&R INSPECTION
1 IP Problem Identification and Resolution 71152B 02/11/2019 02/15/2019
IP Problem Identification and Resolution 71152B 02/25/2019 03/01/2019 7111108
- INSERVICE INSPECTION RF20
1 IP Inservice Inspection Activities - BWR 7111108G 02/14/2019 04/25/2019 7111108
- INSERVICE INSPECTION RF20
1 IP Inservice Inspection Activities - BWR 7111108G 02/18/2019 02/22/2019 RS 12 PI
- RP INSPECTION
1 IP Radiological Hazard Assessment and Exposure Controls 71124.01 02/25/2019 03/01/2019
IP Occupational ALARA Planning and Controls 71124.02 02/25/2019 03/01/2019
IP Occupational Exposure Control Effectiveness 71151-OR01 02/25/2019 03/01/2019
IP RETS/ODCM Radiological Effluent Occurrences 71151-PR01 02/25/2019 03/01/2019 This report does not include INPO and OUTAGE activities.