IR 05000400/1994006

From kanterella
Jump to navigation Jump to search
Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-400/94-06 on 940415
ML18011A467
Person / Time
Site: Harris 
Issue date: 05/19/1994
From: Christensen H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Robinson W
CAROLINA POWER & LIGHT CO.
References
NUDOCS 9406060118
Download: ML18011A467 (4)


Text

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

)

ACCESSION NBR:9406060118 DOC.DATE: 94/05/19 NOTARIZED:

NO

~

~

~

~

ACIL:50-400 Shearon Harris Nuclear Power Plant, Unit 1, Carolina AUTH.NAME AUTHOR AFFILIATION CHRISTENSEN,H.

Region 2 (Post 820201)

RECIP.NAME RECIPIENT AFFILIATION ROBINSON,W.R.

Carolina Power a Light Co.

SUBJECT:

Ack receipt of 940511 ltr informing NRC of steps taken to correct violations noted 'in insp rept 50-400/94-06 on 940415.

DISTRIBUTION CODE:

IE01D COPIES RECEIVED:LTR ENCL SIZE:

TITLE: General (50 Dkt)-Insp Rept/Notice of Violation Response NOTES:Application for permit renewal filed.

DOCKET N

05000400 S

05000400 F

RECIPIENT ID CODE/NAME PD2-1 PD INTERNAL: ACRS AEOD/DSP/ROAB AEOD/TTC NRR/DORS/OEAB NRR/DRIL/RPEB NRR/PMAS/ILPBl REG FI

RGN2 FILE

EXTERNAL: EGEiG/BRYCE,J.H.

NSIC COPIES LTTR ENCL RECIPIENT ID CODE/NAME LEFN AEOD/DEIB AEOD/DSP/TPAB DEDRO NRR/DRCH/HHFB NRR/DRSS/PEPB NUDOCS-ABSTRACT OGC/HDS1 RES/HFB NRC PDR COPIES LTTR ENCL NOTE TO ALL RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK.

ROOM P 1-37 (EXT. 504-2065) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR

ENCL

MAY I S SS4 Docket No.:

50-400 License No.:

NPF-63 Carolina Power 5 Light Company ATTN:

Hr.

W.

R. Robinson Vice President

- Harris Plant Shearon Harris Nuclear Power Plant P.

O.

Box 165, Hail Code:

Zone

New Hill, NC 27562-0165 Gentlemen:

SUBJECT:

REPORT NO. 50-400/94-06 Thank you for your response of May 11, 1994, to our Notice of Violation issued on April 15, 1994, concerning activities conducted at your Harris facility.

We have evaluated your response and found that it meets the requirements of

CFR 2.201.

We will examine the implementation of your corrective actions during future inspections.

We appreciate your cooperation in this matter.

Sincerely, Harold 0. Christensen, Acting Chief Reactor Projects Branch

Division of Reactor Projects cc:

Hr.

W. S. Orser Executive Vice President Carolina Power and Light Company Shearon Harris Nuclear Power Plant P. 0.

Box 1551

- Hail Code CPB

Raleigh, NC 27602-1551 H.

W. Habermeyer, Jr.

Vice President Nuclear Services Department Carolina Power 8} Light Company P. 0.

Box 1551

- Hail OHS7 Raleigh, NC 27602 (cc cont'd - See page 2)

O c'

8} p Q 9406060118 940519 PDR ADOCK 05000400 Q

PDR

NAY 19 N4 Carolina Power 8 Light Company (cc cont'd)

David McCarthy, Manager Regulatory Affairs Harris Nuclear Project P. 0.

Box 165 New Hill, NC 27562 H.

Ray Starling Vice President

- Legal Department Carolina Power and Light Co.

P. 0.

Box 1551 Raleigh, NC 27602 Dayne H. Brown, Director Division of Radiation Protection N.

C. Department of Environmental Commerce 5 Natural Resources P. 0.

Box 27687 Raleigh, NC 27611-7687 Karen E.

Long Assistant Attorney General State of North Carolina P. 0.

Box 629 Raleigh, NC 27602 Public Service Commission State of South Carolina P. 0.

Box 11649 Columbia, SC 29211 Admiral Kinnaird R.

McKee 214 South Morris Street Oxford, MD 21654 Robert D. Martin 3382 Sean May Lawrenceville, GA 30244 bcc:

(See page 3)

Carolina Power 5 Light Company bcc:

H. Christensen, RII N. Le, NRR Document Control Desk MAY I 9 $94 NRC Resident Inspector U. S. Nuclear Regulatory Commission 5421 Shearon Harris Road New Hill, NC 27562-9998 SEND TO PDR?

FC RII:DRP JStarefos:tj HANE

~ /94 ATE No COPY?

OFFICIAL REC RD COPY Ho

/

/94 Yes No

/

/94 Yes DOCUNEHT HANE:

P:iNAR.IIP5 No

/

/94 Yes

/

/94 Yes No