IR 05000373/2009002
Download: ML091280150
Text
May 7, 2009
Mr. Charles Senior Vice President, Exelon Generation Company, LLC President and Chief Nuclear Officer (CNO), Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555
SUBJECT: LASALLE COUNTY STATION, UNITS 1 AND 2 NRC INTEGRATED INSPECTION REPORT 05000373/2009002; 05000374/2009002
Dear Mr. Pardee:
On March 31, 2009, the U.S. Nuclear Regulatory Commission (NRC) completed an integrated inspection at your LaSalle County Station, Units 1 and 2. The enclosed report documents the results of this inspection, which were discussed on April 16, 2009, with Plant Manager, Mr. Dave Rhoades, and other members of your staff. The inspection examined activities conducted under your license as they relate to safety and compliance with the Commission's rules and regulations and with the conditions of your license. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel. Based on the results of this inspection, no NRC-identified or self-revealed findings of safety significance were identified. One licensee-identified violation is listed in Section 4OA7 of this report. In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter, its enclosure, and your response (if any) will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system (ADAMS). ADAMS is accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
Sincerely,/RA/ Kenneth Riemer, Chief Branch 2 Division of Reactor Projects Docket Nos. 50-373; 50-374 License Nos. NPF-11; NPF-18
Enclosure:
Inspection Report 05000373/2009002; 05000374/2009002
w/Attachment:
Supplemental Information cc w/encl: Site Vice President - LaSalle County Station Plant Manager - LaSalle County Station Manager Regulatory Assurance - LaSalle County Station Senior Vice President - Midwest Operations Senior Vice President - Operations Support Vice President - Licensing and Regulatory Affairs Director - Licensing and Regulatory Affairs Manager Licensing - Braidwood, Byron and LaSalle Associate General Counsel Document Control Desk - Licensing Assistant Attorney General J. Klinger, State Liaison Officer, Illinois Emergency Management Agency Chairman, Illinois Commerce Commission
SUMMARY OF FINDINGS
......................................................................................................... 1
REPORT DETAILS
..................................................................................................................... 2 Summary of Plant Status.........................................................................................................
REACTOR SAFETY
..................................................................................................... 2
1R04 Equipment Alignment
............................................................... 2
1R05 Fire Protection
......................................................................... 3
1R08 Inservice Inspection (ISI) Activities
.......................................... 4
1R11 Licensed Operator Requalification Program
............................. 5
1R12 Maintenance Effectiveness
...................................................... 6
1R13 Maintenance Risk Assessments and Emergent Work Control
.. 7
1R15 Operability Evaluations
............................................................ 7
1R18 Plant Modifications
................................................................... 8
1R19 Post-Maintenance Testing (PMT)
............................................ 9
1R20 Outage Activities
.................................................................... 10
1R22 Surveillance Testing
.............................................................. 11
1EP2 Alert and Notification System (ANS) Evaluation
..................... 12
1EP3 Emergency Response Organization Augmentation Testing
... 13
1EP5 Correction of Emergency Preparedness Weaknesses and Deficiencies
RADIATION SAFETY
................................................................................................. 14 2OS1 Access Control to Radiologically Significant Areas (71121.01) ................ 14 2OS2 As-Low-As-Is-Reasonably-Achievable Planning and Controls (ALARA) (71121.02) ............................................................................................... 19 2PS1 Radioactive Gaseous And Liquid Effluent Treatment And Monitoring Systems (71122.01)
OTHER ACTIVITIES
.................................................................................................. 24
4OA1 Performance Indicator Verification
.............................................. 24
4OA2 Identification and Resolution of Problems
................................... 27
4OA5 Other Activities......................................................................................... 28 4OA6
Management Meetings ............................................................................ 29 4OA7 Licensee-Identified Violations .................................................................. 29
SUPPLEMENTAL INFORMATION
KEY POINTS OF CONTACT
Licensee
- D. Enright, Site Vice President prior to March 2, 2009
- D. Wozniak, Site Vice President after March 2, 2009
- D. Rhoades, Plant Manager
- K. Aleshire, Exelon EP Programs Manager
- D. Amezaga, GL 89-13 Program Owner
- J. Bashor, Site Engineering Director
- L. Blunk, Operations Training Manager
- J.C. Feeney, NOS Lead Assessor
- B. Ginter, Engineering Programs Manager
- F. Gogliotti, System Engineering Senior Manager
- D. Henly, Design Engineer
- W. Hilton, Engineering Supervisor - Mechanical/Structural
- K. Ihnen, Nuclear Oversight Manager
- R. Leasure, Radiation Protection Manager
- S. Marik, Operations Director
- B. Rash, Maintenance Director
- J. Rommel, Design Engineering Senior Manager
- K. Rusley, Emergency Preparedness Manager
- J. Shields, ISI Program Supervisor
- T. Simpkin, Regulatory Assurance Manager
- K. Taber, Work Management Director
- J. Vegara, Regulatory Assurance
- H. Vinyard, Shift Operations Superintendent
- J. White, Site Training Director
- G. Wilhelmsen, Design Manager
- S. Wilkinson, Chemistry Manager
- C. Wilson, Station Security Manager
Nuclear Regulatory Commission
- D. Anthony, NDE Level III
- K. Riemer, Chief, Reactor Projects Branch 2
Attachment
LIST OF ITEMS
OPENED, CLOSED AND DISCUSSED Opened None. Closed Temporary Instruction
2515/175 TI Emergency Response Organization, Drill/Exercise Performance Indicator, Program Review" Discussed None.
Attachment
LIST OF DOCUMENTS REVIEWED
The following is a partial list of documents reviewed during the inspection.
- Inclusion on this list does not imply that the NRC inspector reviewed the documents in their entirety, but rather that selected sections or portions of the documents were evaluated as part of the overall inspection effort.
- Inclusion of a document on this list does not imply NRC acceptance of the document or any part of it, unless this is stated in the body of the inspection report. 1R04 Equipment Alignment PROCEDURES Number Description or Title Date or Revision
- LOP-DG-03E Unit 0 DG Electrical Checklist Rev. 9
- LOP-DG-03M Unit 0 DG Mechanical Checklist Rev. 8
- LOP-LP-02E Unit 2 Low Pressure Core Spray System Electrical Checklist Rev. 5
- LOP-LP-02M Unit 2 Low Pressure Core Spray System Mechanical Checklist Rev. 12
- LOP-RH-2BM Unit 2 B RHR System Mechanical Checklist Rev. 2
- 1R05 Fire Protection
- MISCELLANEOUS Number Description or Title Date or Revision
- LSCS-FPR LaSalle Fire Protection Report Revs. 2 & 3
- 1R08 Inservice Inspection Activities CAP DOCUMENTS Number Description or Title Date or Revision
- Welds 10/30/2008
- 869885 Indication Identified in Steam Dryer During IVVI Examinations 1/22/2009
- NDE PROCEDURES Number Description or Title Date or Revision
- VT-1 Visual Examination Rev. 4
- GE-MT-100 Magnetic Particle Examination Version 8
- GEH-PDI-UT-1 PDI Generic Procedure for the Ultrasonic Examination of Ferritic Pipe Welds Rev. 6
- Attachment MISCELLANEOUS Number Description or Title Date or Revision 2R11-008 GE Examination Summary Sheet
- 1R12 Maintenance Effectiveness
- PROCEDURES Number Description or Title Date or Revision
- ER-AA-310 Implementation of the Maintenance Rule Rev. 6
- CAP DOCUMENTS Number Description or Title Date or Revision
- 577150 Recorder Drive Belt is Broken 1/9/2007
- 578215 Paper jam on 1D21-R600B 1/11/2007
- 579102 MCR Recorder Paper Carriage Broken 1/15/2007
- 579880 0D21-R600CC Arm Point 3-14 Erratic 1/17/2007
- 580874
- RM-23 Effluent Flow Light Not Lit 1/19/2007
- 581029
- LIS-PR-054/055 WGRM Functional Test Creates Nuisance Alarms 1/19/2007
- 583057 OOT (Failed), 2D18-K699A, Trend Code B3 1/25/2007
- 588645 Audio Alarm Not Working 2/7/2007
- 590606 NOS ID: Numerous Inaccuracies in IR#
- 588042 2/12/2007
- 2876 VC Intake Rad Monitor 2D18-K751A Failure 2/18/2007
- 596811 Trend Code B4 - 2D18-K601A Discrim Found Out of Tolerance 2/27/2007
- 596815 Trend Code B4 - 2D18-K601A H.V. Found Out of Tolerance 2/27/2007
- 597050 Trend Code B4 - 2D18-K601B H.V. Found Out of Tolerance 2/28/2007
- 597690
- LOA-AR-201 Entry 3/1/2007
- 602128 VC Rad Area Detector's and System Issues/Questions 3/11/2007
- 603068 0D21-K602K RW Arm Alarmed Downscale 3/13/2007
- 603367 0D21-K602K "Radwaste Arm Down Scale" Alarm 3/13/2007
- 610977 Verify Calibration of
- 621281 Incorrect Arm Setpoints in Passport 4/24/2007
- 628637 Control Room Vent Ammonia Detector is Showing Fault 17 5/12/2007
- 662052 0B VC "C" Minitor Instrument Failure 8/18/2007
- 662052 0B VC "C" Monitor Instrument Failure 8/18/2007
- Attachment CAP DOCUMENTS Number Description or Title Date or Revision
- 668162 Results of 2B VC troubleshooting / Detector Replacement 9/5/2007
- 669671 Unit 1 Main Steam Line High Rad Alarms 9/10/2007
- 670651 B VC/VE Netdaq Bad Readings 9/12/2007
- 716315 'A' VC RAD monitors A and B Step Change 12/28/2007
- 717023 Refuel Floor Hi Range Rad Monitor Downscale Alarm 1/1/2008
- 717628 Off Gas Bldg Charcoal Valve Aisle Arm Oscillating Indication 1/3/2008
- 724616 Refuel Floor Hi Range Arm Downscale Alarm 1/19/2008
- 731386 RB High Rad Alarm 2/4/2008
- 745578 Radwaste Arm Down Scale Alarm 3/6/2008
- 751109 Modification would Result in Three Wires at One Term Point 3/18/2008
- 758944 Bearing Degradation Identified on 0VC01CA 4/3/2008
- 759978 Area Rad Recorder 2D21-R600C 4/7/2008
- 841704 Received Downscale Alarm 11/7/2008
- 2524 Area Rad Monitor Causing Spurious RW control Room Alarms 11/9/2008
- 846168 0D21-K601O Arm Downscale Alarm 11/17/2008
- 848374 Arm 1D21-K602E Hi and Downscale bypass Switches Malfunction 11/21/2008
- 850120 U-1 WS PRM Failed Source Check 11/27/2008
- 852431 Maintenance Rule Performance Criteria (A)(2) at Risk 12/4/2008
- 852431 Maintenance Rule Performance Criteria (A)(2) at Risk 12/4/2008
- 859950 'C' VC Rad Monitor Failure 12/24/2008
- LOS-PR-M2 12/26/2008
- 862290 "C" VC Rad Monitor Failed Downscale 1/2/2009
- 873216 Shaw - 2DG01P Bolting Issue 1/28/2009
- MISCELLANEOUS Number Description or Title Date or Revision
- 2008 Failure Report [Process Radiation Monitoring (PR)] 2008
- Maintenance Rule Scoping (misc) [PR] 1/6/2009
- Performance Criteria Report For PR 1/6/2009
- Risk Significance Summary (misc) [PR] 1/6/2009
- Attachment
- WORK DOCUMENTS Number Description or Title Date or Revision
- WO 1100429 2A DG Cooling Water Pump Inservice Test 4/29/2008
- WO 1131013 2A DG Cooling Water Pump Inservice Test 7/29/2008
- WO 1156762 2A DG Cooling Water Pump Inservice Test 10/28/2008
- WO 1181966 2A DG Cooling Water Pump Inservice Test 1/13/2009
- 1R13 Maintenance Risk Assessments and Emergent Work Control PROCEDURES Number Description or Title Date or Revision
- LFP-100-1 Master Refuel Procedure Rev. 46
- LOA-FH-001 Irradiated Fuel Assembly Damage Rev. 2
- CAP DOCUMENTS Number Description or Title Date or Revision
- 719194 Door Alarm Not Working 1/8/2008
- 814742 Security- Door 494 Will Not Throw Strike 9/6/2008
- 2750 Unit 2 RFB Mast -Braided Wire Load Cable 1 of 2 Failed 1/28/2009
- WORK DOCUMENTS Number Description or Title Date or Revision
- Operations Log Entries 1/28/2009
- Operations Log Entries 3/16-17/2009
- Protected Equipment List 2/19/2009
- WO 652137 MM Disassemble, Inspect Heat Exchanger 4/14/2008
- Attachment DRAWINGS Number Description or Title Date or RevisionB-39968-3/ 22127-1 General Arrangement:
- DLW Transfer System Rev. E D-01677101-C Cable, Assy:
- Main Hoist Rev. 4
- 1R15 Operability Evaluations
- PROCEDURES Number Description or Title Date or RevisionLLP-2009-02 Special Procedure:
- LOP-RH-01 Filling and Venting the RHR System Rev. 40
- LOP-SC-05 Changing Sodium Penaborate Concentration in SBLC Solution Tank Rev. 20
- LOR-2H13-P601 -C509 Reactor Vessel Head Flange O-Ring Seal Leaking Rev. 1
- LOS-AA-S101 Unit 1 Shiftly Surveillance Rev. 54
- LOS-RI-M1 Reactor Core Isolation Cooling System Inservice Test in Modes 1, 2, & 3 Rev. 15
- CAP DOCUMENTS Number Description or Title Date or Revision
- 798176 NRC
- GL 2008-01 Gas Intrusion Field Activities (1E22-F026) 7/18/2008
- 798178 NRC
- GL 2008-01 Gas Intrusion Field Activities (2E22-F026) 7/18/2008
- 798182 NRC
- GL 2008-01 Gas Intrusion Field Activities (1E12-F340) 7/18/2008
- 798184 NRC
- GL 2008-01 Gas Intrusion Field Activities (2E12-F340) 7/18/2008
- 798186 NRC
- GL 2008-01 Gas Intrusion Field Activities (1E12-F053A) 7/18/2008
- 798198 NRC
- GL 2008-01 Gas Intrusion Field Activities (2E12-F053A) 7/18/2008
- 811220 NRC
- GL 2008-01 Tech Evals -Fleet Wide Gaps 8/26/2008
- 816204 Air Pocket Detected in High Point of HPCS System Piping 9/10/2008
- 864756 Preoutage Snubber Failure:
- Snubber 2RH53-2848S 1/9/2009
- 864756 Preoutage Snubber Failure:
- Snubber 2RH53-2848S 1/9/2009
- 867935 Snubber 2RH53-2816S Failed Functional Test 1/16/2009
- Attachment CAP DOCUMENTS Number Description or Title Date or Revision
- 869857 L1C13 PPLX Core Monitoring System Vulnerability 1/22/2009
- 876414 U-1 SBLC % Sodium Pentaborate and SBLC Tank Level 2/5/2009
- 882880 High Fuel Liftoff (Oxide & Crud) Measured on LS AREVA Fuel 2/19/2009
- Chk; 6 DPM leak from stem 3/16/2009
- 893704 RCIC Pipe believed to not be Completely Filled with Water 3/16/2009
- WORK DOCUMENTS Number Description or Title Date or Revision
- WO 1010301 IM 2E31-No34 Drain / Blow Out RX VSL Head Flange Instr for RXS 5/16/2008
- Outage Control Center Log (Nights) 2/5/2009
- OPERABILITY EVALUATIONS Number Description or Title Date or Revision
- EC 37316, Rev 0; Evaluation of RHR Snubber Failure 2RH53-2816S & 2RH53-2848S Rev. 10
- EC 374170 Evaluate Degraded / Plugged Line from Reactor vessel O-Ring Leak Off Monitoring System Rev. 0 OE08-003 HPCS System (HP/E22):
- Description of degradation or nonconforming condition of SSCs Rev. 0
- OE 09-001 RCIC packing leak on injection outboard check valve (IR 891474) Rev. 0
- OE 00-001 Operability Determination:
- RCIC pump injection valve leak Rev. 5
- TECHNICAL EVALUATIONS Number Description or Title Date or Revision
- Attachment TECHNICAL EVALUATIONS Number Description or Title Date or Revision
- EC 374170 Evaluate Degraded / Plugged Line from Reactor Vessel O-Ring Leak Off Monitoring System Rev. 0
- MISCELLANEOUS Number Description or Title Date or Revision
- ER-AA-335-007 Ultrasonic Water Solid Sedimentation Calibration Sheet 2/9/2009
- IR 869141 Apparent Cause Evaluation:
- U2 RPV Head Lift Stopped due to High Weight Indication (LS-AA-125-1003) 2/26/2009
- LaSalle Unit 2 Cycle 13 Core Operating Limits Report Rev. 0
- IR 869141 Equipment Prompt Investigation Report:
- U2 RPV Head Lift Stopped due to High Weight Indication
- Rev. 13
- LSCS-UFSAR In-place Annealing of the Reactor Vessel is Unnecessary Rev. 13
- LSCS-UFSAR 7.7.15.2.6 Safety/Relief Valve Leak Detection Rev. 15
- DRAWINGS Number Description or Title Date or Revision
- ISI-RH-1002 Inservice Inspection Isometric RHR System Rev. A
- ISI-RH-1005 Inservice Inspection Isometric RHR System Rev. A
- ISI-RH-1006 Inservice Inspection Isometric RHR System Rev. A M-142 P & ID Residual Heat Removal System Rev. AZ
- 5660-06 Sargent & Lundy Contractor Construction Approval Drawing :
- 6"-900" Tilt Disc Check Valve Pressure Seal, Butt Weld Ends, Exercisable from Closed Position 5/1/1977
- Attachment 1R18 Plant Modifications CAP DOCUMENTS Number Description or Title Date or Revision
- 786131 1A RVDT Failure Alarm Reflashed 6/13/2008
- 791320 Results of Des Eng Review of RVDT Troubleshooting Plan 6/27/2008
- 870486 Additional Coordination Problems for RCMS Circuits 1/23/2009
- 870672 U2 RCMS Issue 1/23/2009
- 870679 RCMS Issue with LPRM Indication 1/23/2009
- 870963 Annunciator Tile Inputs Swapped During RCMS Installation 1/23/2009
- 871406 Control rod 58-31 Lost Position Indication 1/25/2009
- 871608 Rod Block Monitor A Inconsistency 1/26/2009
- 871608 Rod Block Monitor A Inconsistency 1/26/2009
- 871641 42-03 Shows XX for Position 1/26/2009
- 871735 Plant Process Computer Not Showing Correct Rod Position 1/26/2009
- 871740 Low Power Setpoint and Alarm on PPC Labeled Wrong 1/26/2009
- 871778 22-55 RPIS Issue 1/26/2009
- 872112
- 872113
- 874133 Trolley Joystick malfunctions on Unit 2 Refueling Bridge
- 874564 RCMS Controller Minor Software Error Identified 1/31/2009
- 874670 U2 RFB Main Grapple Redundant Z-Axis Encoder Failure 2/1/2009
- 874773 Joy Stick Failure for Up and Down of Mast 2/1/2009
- 874872 Refuel Bridge Issue 2/2/2009
- 875342 Control Rod 10-19 Missing Position 02,12,22,32, and 42 2/3/2009
- 875566 Control Rod Missing Multiple Positions 2/3/2009
- 875572 Control Rod 38-19 Missing Multiple Positions 2/3/2009
- 875728 Control Rod 10-31 Missing Multiple Positions 2/3/2009
- 875730 Control Rod 06-35 Missing FI Indication 2/3/2009
- 875737 Control Rod 14-27 Missing Multiple Positions 2/3/2009
- Attachment CAP DOCUMENTS Number Description or Title Date or Revision
- 875851 Rod 58-31 Exhibited Two Odd Notches between 14 and 16 2/4/2009
- 875885 RCMS Scram Time Test Signal 2/4/2009
- 876559 PPC Issues with RCMS Testing 2/5/2009
- 876617 RCMS Rod Withdraw Issue During Post Installation testing 2/5/2009
- 876617 RCMS Rod Withdraw Issue During Post Installation Testing 2/5/2009
- 878000 RCMS Trouble/Test Alarm 2/8/2009
- DRAWINGS Number Description or Title Date or Revision UFSAR G.5.2-1 Configuration of the RRFC System Rev. 15 UFSAR G.5.2-2 Valve Actuator Hydraulic Power Unit Rev. 0
- WORK DOCUMENTS Number Description or Title Date or Revision
- EC 365184 Modify Unit 2 Main Turbine Bypass Valve #1 Position Alarm Logic 4/24/2007
- The RVDT Signal has Degraded. 10/3/2008
- LST-2005-027 Work Verifications / GANG Sequences 1/26/2009 TCCP
- 337725 Bypass the Reactor Recirc Flow Control Valve RVDT Mismatch Alarm Rev. 0
- WO 1113726 IM 1B33-N452A Replace RVDT on 1A RR FCV 3/12/2008
- MISCELLANEOUS Number Description or Title Date or Revision
- LSCS-UFSAR Feedwater Control System Instrumentation and Controls Rev. 15
- LSCS-UFSAR Recirculation Flow Control System Instrumentation Rev. 15
- Attachment 1R19 Post-Maintenance Testing CAP DOCUMENTS Number Description or Title Date or Revision
- 839987 Review IR Database for Seasonal Pattern 12/31/2008
- 872155 FME Found in Main Steam Piping During SRV Flange Inspection 1/26/2009
- 876280 2A FCV Actuator Stroke Length Shorter Than Proc. Allowable 2/4/2009
- 891599 New WRGM Pump from Stores Failed to Produce Rated Pressure 3/11/2009
- PROCEDURES Number Description or Title Date or Revision
- LIS-PR-055 Standby Gas Treatment System Wide Range Gas Monitor Functional Test Rev. 25
- LIS-RR-210A Unit 2 Recirculation HPU Loop A Control and 2B33-F060A Limit Switch Calibration Rev. 5
- LOP-VP-02 Startup, Operation and Shutdown of Primary Containment Chilled Water and Ventilation System Rev. 33
- LTS-300-2 Drywell Personnel Air Lock Local Leak Rate Test Rev. 15
- WORK DOCUMENTS Number Description or Title Date or Revision
- WO 1058185 ES Integrated Division 1 ECCS Response Time Pumps and Diesel 1/24/2009
- WO 1058266 Unit 2 Main Steam Safety Relief Valve Operability Test 1/30/2009
- WO 1063570 DW Personnel Air Lock LLRT (Barrel) 11/26/2008
- Attachment 1R20 Outage Activities
- PROCEDURES Number Description or Title Date or Revision
- LGP-2-1 Normal Unit Shutdown Rev. 79
- CAP DOCUMENTS Number Description or Title Date or Revision
- 868501 Control Rod 34-59 Took 20 Minutes to Insert 1/19/2009
- 868668 Contamination of Three Boilermakers 1/19/2009
- 868704 Elevated Dose Rates Identified during L2R12 1/19/2009
- 868736 RX Cavity Workers Receive Dose Rate Alarms 1/20/2009
- 868768 Unit 2 Plant Process Computer Shut Down 1/20/2009
- 868773 Operators Observed Oil Pouring Out of Motor on Start 1/20/2009
- 869001 Packing Leak on 2B21-F022D MSIV 1/20/2009
- 869141 U2 RPV Head Lift Stopped Due to High Weight Indication 1/20/2009
- 869235 Control Rod Settle Issues during L2C12 S/D 1/20/2009
- 869856 Alarm Panel S-Switch Inadvertently Bumped Off 1/22/2009
- 869857 L1C13 PPLX Core monitoring System Vulnerability 1/22/2009
- 869942 Lesson Learned: Refuel Bridge Delays Fuel Movement 1/22/2009
- 869948 Single Blade Guides will not Grapple with U2 RFB 1/22/2009
- 870368 2B21-F032A Check Valve Fails LLRT 1/22/2009
- 870634 Security-Declared Contraband at Security Checkpoint 1/23/2009
- 871310 Slight Increase in Cobalt 60 Observed in a Chemistry Sample 1/24/2009
- 871319 Low DIV 1 SWGR Temps Entered
- LOA-VX-201 1/24/2009
- 871353 Sipping Results Indicate Fuel Leaker 1/25/2009
- 871560 Unit Crane #1 has Inadvertently Dropped the Load Three Feet 1/25/2009
- 871632 Jet Pump 15 main Wedge Wear
- INR 09-07 1/26/2009
- 871998 Deformation on Vessel guide Rod at 180 degrees;
- INR 09-11 1/26/2009
- 872347 FME Removed During Suppression Pool Inspection 1/27/2009
- 872457 U-2 RCIC Trip and Throttle Valve Failed to Trip 1/27/2009
- 872750 U2 RFB Mast - Braided Wire Load Cable 1 of 2 Failed 1/28/2009
- 872798 2A VP Chiller Trips on High Motor Temp. 1/28/2009
- Attachment CAP DOCUMENTS Number Description or Title Date or Revision
- 872887 As Left Leakrate of 2VQ026 Exceeds Warning Limit 15 SCFH 1/28/2009
- 874244 Shaw - Lost Ed in DW 1/30/2009
- 874413 Increased Exposure Observed after Shielding Installed 1/30/2009
- 874657 Shaw - Sea Van Slides off of Truck Backing into Refuel Pad 2/1/2009
- 874803 Contaminated Flashlight Found in MAF 2/1/2009
- 875318 Cracks Found in Body of Valve 2/3/2009
- 875366 Floor Drain in Bullpen Reading 2 Rem/Hr 2/3/2009
- 875502 Shaw - 4 PCE's on Refuel Floor 2/3/2009
- 875829 Knurled Knob for Garden Sprayer Missing in RX Cavity 2/4/2009
- 875841 2RE08 Overflow in 673 RCIC Room 2/4/2009
- 875842 L2R12 - FME Identified in Dryer Sep Pit and Cavity Wall 2/4/2009
- 875845 IRM "A" Spiked Full Scale Causing a Half Scram 2/4/2009
- 875852 Found 2RE013A Stuck Open 2/4/2009
- 876412 2H IRM Spiked Causing Half Scram 2/5/2009
- 878001 Minor Issues from U-2 Drywell Closeout with NRC 2/8/2009
- 878589 Coordination Issue between Turbine Roll and Switching 2/10/2009
- DRAWINGS Number Description or Title Date or Revision BIF DWG 8-236275 Reactor Water Cleanup System Rev. A
- ISI-RT-2001 Inservice Inspection Isometric Reactor Water Clean-up System Rev. A J-2961 Universal Venturi Tube Rev. B M-143 P & ID Reactor Water Clean-Up Rev. AK
- MISCELLANEOUS Number Description or Title Date or Revision
- L2R12 Scope deletion/deferral list (since start of L2R12) 1/27/2009
- Shutdown Load Profile
- IR 868704 Equipment Issue Report: Dose Rates in Containment higher than Expected 1/21/2009
- Attachment MISCELLANEOUS Number Description or Title Date or Revision
- IR 868768 Equipment Issue Report: Unexpected Shutdown of Unit 2 PPC 1/20/2009
- IR 869837 Human Performance Issue: Error in L1C13 POWERPLEX-III input deck. Rev. 13
- OU-LA-104 Shutdown Safety Management Program Rev. 11
- 1R22 Surveillance Testing PROCEDURES Number Description or Title Date or Revision
- LES-DC-103A Division 1 Battery Charger Capacity Test Rev. 17
- LOS-DG-M3 1B (2B) Diesel Generator Operability Test Rev. 69
- LOS-HP-Q1 HPCS System Inservice Test Rev. 60
- LOS-NB-R2 Unit 2 Reactor Vessel Leakage Test Rev. 03
- LOS-RI-M1 Reactor Core Isolation Cooling System Inservice Test in Modes 1, 2, & 3 Rev. 15
- LOS-RI-Q5 Reactor Core Isolation Cooling (RCIC) System Pump Operability, Valve Inservice Tests in Modes
- 1,2,3 and Cold Quick Start Rev. 30
- LOS-RI-R3 Reactor Core Isolation Cooling System Pump Operability Test Rev. 32
- LTS-100-35 RHR Shutdown Cooling Suction Isolation Valves Local Leak Rate Test Rev. 16
- LTS-300-4 Primary Containment Integrated Leak Rate Test Rev. 26
- CAP DOCUMENTS Number Description or Title Date or Revision
- 872887 As Left Leakrate of 2VQ026 Exceeds Warning Limit 15 SCFH 1/28/2009
- 875874 2C Outboard MSIV Packing Leak 2/4/2009
- 875875 Packing Leaking Steady Stream of Water 2/4/2009
- 876556
- LOS-NR-R2
- HCU-D5027-107 Leak 2/5/2009
- 876558
- LOS-NR-R2
- 876568
- LOS-NR-R2
- 876572
- LOS-NR-R2 2E31-N013-LLD Leaks 2 Drops per Minute 2/5/2009
- Attachment CAP DOCUMENTS Number Description or Title Date or Revision
- 876632
- LOS-NR-R2
- 876636
- LOS-NB-R2
- HCU 14-19 107 Valve Seat Leakage 1 Drop/Sec 2/5/2009
- 876673
- LOS-NB-R22
- 876679
- LOS-NB-R2
- 876830 Dilution Trash Rake Cable Disconnected from Rail 2/5/2009
- 876859 2B33-F023B has Moisture Noted at Packing During Hydro 2/5/2009
- 876991 Packing Leakage Detected During System Leakage Test 2/5/2009
- 876993 Valve Packing Leak 2/5/2009
- WORK DOCUMENTS Number Description or Title Date or Revision
- LOS-HP-Q1 Tech Spec Surveillance Unit 1 HPCS Pump Run, Att. 1A 1/9/2009
- WO 1051264 Inspect Div 1 125 Volt battery Charger 11/11/20008
- WO 1051593 U-2 Div 1 125 VDC Battery Charger Capacity Test 11/11/2008
- WO 1126100 LLRT, 2E12-F009 11/7/2008
- LOS-RI-Q5 U1 RCIC Cold-Quick Start 1/13/2009
- Attachment MISCELLANEOUS Number Description or Title Date or Revision Fig. RCS P/T Limits 3.4.11-4 P-T Curves for Hydrostatic or Leak Testing up to 20 EFPY
- LOS-NB-R2 Visual Inspection Location Record: Leakage and Abnormalities Inspection 6/9/2008
- 1EP2 Alert and Notification (ANS) Evaluation CAP DOCUMENTS Number Description or Title Date or Revision
- 564530 LaSalle Alert and Notification System Reached a 25 Percent Outage 12/2/2006
- 806699 Midwest Siren Outage 8/13/2008
- 860464 LaSalle Alert Notification System Reached an Outage Greater than 25 Percent 12/27/2008
- MISCELLANEOUS Number Description or Title Date or Revision
- Design Report Updated, Upgraded Public Alert and Notification System (ANS), LaSalle Nuclear Power Plant (LNPP), Final 10/31/2008
- LaSalle Monthly Siren Availability Report (Telemetry) 1/2008 - 12/2008
- LaSalle Monthly Siren Availability Report (Telemetry) 1/2007 - 12/2007
- LaSalle Off-Site Siren Test Plan 12/2008
- LaSalle Plant, Warning System Maintenance and Operational Report 1/9/2007 - 3/1/2007
- LaSalle Plant, Warning System Maintenance and Operational Report 12/17/2007 - 1/25/2008 LaSalle Siren Daily Operability Reports 1/2008 - 12/2008
- LaSalle Siren Daily Operability Reports 1/2007 - 12/2007
- Attachment
- 1EP3 Emergency Response Organization (ERO) Augmentation Testing CAP DOCUMENTS Number Description or Title Date or Revision
- 619412 NOS ID:
- 796802 EP Call-In Drill Duty Team Members Did Not Respond 7/15/2008
- 843943 - Deficiency in Staffing Response Time 12/16/2008
- 843943 - Deficiency in Augmentation Drills Time/Day 12/16/2008
- MISCELLANEOUS Number Description or Title Date or Revision
- ERO Augmentation Memo, Call-In Augmentation Drill Results, Site and Corporate 7/2007 - 12/2008
- Exelon Nuclear Corporate Emergency Preparedness, Radiation Emergency Response, St. Mary's Hospital, Streator, IL Radiation Emergency Response, Fire Department/EMS/Hospital Training 3/3/2005
- LaSalle Station ERO Roster 1/9/2009
- Letters of Agreement between Exelon and Off-Site Medical and Fire Agencies 2008
- EP-AA-1000 Exelon Nuclear Standardized Radiological Emergency Plan Rev. 19
- Exelon Nuclear Standardized Radiological Emergency Plan, Table B-1:
- Minimum Staffing Requirements for the Exelon ERO Rev. 19
- 1EP5 Correction of Emergency Preparedness Weaknesses and Deficiencies CAP DOCUMENTS Number Description or Title Date or Revision
- 619217 NOS ID EP Corrective Action Narrowly Focused 4/19/2007
- 660465 FASA Results:
- Maintenance Schedule Adherence 8/14/2007
- Attachment CAP DOCUMENTS Number Description or Title Date or Revision
- 672939 Off-Year Exercise - Unsatisfactory OSC Demo Criteria 9/19/2007
- 718948 01/07/08 High Temperature Reading of 84 Degrees in the TSC 1/7/2008
- 725732 TSC Room Temp HI Alarm 1/23/2008
- 749602 Control Room Habitability Review of
- NEI 99-03 Reveals Deltas 3/14/2008
- 758605 EP Pre-Exercise Simulator Demonstration Criteria Failure 4/3/2008
- 764322 NOS Identified Obsolete PING Running in Old OSC 4/17/2008
- 764375 NOS ID:
- 765070 NOS ID:
- EP 1Q08 Performance Rated as Yellow 4/18/2008
- 767316 EP Procedures and Expectations Are Not Fully Aligned 4/24/2008
- 815733 NOS Identified Issue Regarding EP Equipment Status 9/9/2008
- 822349 TSC PING Fails Source Check 9/25/2008
- 843943 - Deficiency in ERO Participation 12/16/2008
- 865133 TSC Room HI Temp Alarm 1/10/2009
- 881701 EP NRC Concerns with Detection Limits Associated with Radioiodines and Thyroid Dose Assessment 2/17/2009
- PROCEDURES Number Description or Title Date or Revision
- EP-AA-112-500- F-01
- Field Monitoring Team Checklist
- Rev. D
- Personnel Protective Actions, Attachment 4
- Rev. 4
- EP-AA-113 Personnel Protective Actions
- Rev. 9
- EP-MW-110-200 Dose Assessment
- Rev. 5
- EP-MW-123- 1002 Dose Assessment and Protective Action Recommendation (DAPAR) Program Technical Basis
- Rev. 3
- Attachment PROCEDURES Number Description or Title Date or Revision
- LS-AA-126-1001 FASA Self-Assessment Report, Emergency Preparedness, NRC EP Exercise Inspection Readiness, #
- 707324, Attachment 2
- 3/24/2008
- LS-AA-126-1005 Check-In Self-Assessment Report, Emergency Preparedness, 2009 NRC Baseline Program Inspection, #
- 843943, Attachment 2
- 12/17/2008
- MISCELLANEOUS Number Description or Title Date or Revision
- Emergency Preparedness Audit
- NOSA-LAS-07-04, AR#
- 576578, LaSalle Station
- 4/16 - 4/20/2007
- Emergency Preparedness Audit
- NOSA-LAS-08-03, AR#
- 713024, LaSalle County Station
- 4/14 - 4/18/2008
- GPU Nuclear
- Memorandum, Subject: Evaluation of the Front Loaded Iodine Cartridge Using Various Survey Equipment 5/12/1988
- NOS Objective Evidence Report, 2007 Emergency Preparedness Audit, Offsite Agency Interface, AR #
- 574311-11
- 5/18/2007
- NOS Objective Evidence Report, 2008 Emergency Preparedness Audit, Offsite Agency Interface, AR#
- 713024-13
- 4/14 - 4/18/2008
- Root Cause Investigation Report, Untimely Emergency (EP) Event Classification Due to Inconsistent Use of the EAL Basis, #
- 752478 3/19/2008
- 2OS1 Access Control to Radiologically Significant Areas
- CAP DOCUMENTS Number Description or Title Date or Revision
- 832223 Radioactive Material Container Not Posted 10/13/2008
- 854228 NOS Identified: Radiological Posting and Boundary Issues 12/9/2008
- 835637 High Rad Rounds Not Proactive Enough 10/24/2009
- 836939 NOS Identified: Clean Island Missing Radiological Postings 10/28/2008
- 856456 Chemistry Personnel Contamination During Sampling 12/15/2009
- 868654 Issues Identified by Radiation Protection Behavior Correction Specialist 1/19/2009
- 868668 Contamination of Three Boilermakers in Reactor 1/19/2009
- Attachment CAP DOCUMENTS Number Description or Title Date or Revision Cavity
- 867955 L2R12 Scaffold Issues Preventing Locked High Radiation Controls 1/16/2009
- 868736 Reactor Cavity Workers Receive Dost Rate Alarms 1/19/2009
- 868742 NOS Identified Individuals Bypassed Greeters 1/19/2009
- 869144 Dose Rate Alarm in RHR Corner Room 1/20/2009
- 869175 Standards Team - Radiation Protection Posting Issue 1/20/2009
- 869227 Luse Worker Contamination Events 1/20/2009
- 869786 Shaw Insulator Dose Rate Alarm in Drywell 1/21/2009
- 870346 Standards Team Identifies Radiation Worker Practice Issues 1/22/2009
- 870926 Master-Lee Individual Received Contamination 1/23/2009
- 872082 L2R12 Reactor Building Dose Rate Alarm 1/26/2009
- 2094 Shaw - Two Carpenters Received Dose Rate Alarms in Drywell 1/26/2009
- 873922 Personnel Contamination - Shaw Laborer Contaminated in Clean Area 1/30/2009
- 874803 Contaminated Flashlight Found in Main Access Facility 2/1/2009
- 875366 Floor Drain in Bullpen Reading 2 Rem per Hour 2/3/2009
- 875502 Shaw - Four Personnel Contaminations on the Refuel Floor 2/3/2009
- 832223 Radioactive Material Container Not Posted 10/13/2008
- RADIATION WORK PERMITS REVIEWED Number Description or Title Date or Revision
- 10009379 L2R12 RT Suction Flow Orifice Weld In-Service Inspection Rev. 0
- 10009393 Drywell Reactor Recirculation Motor Activities Rev. 1
- 10009413 L2E12 Refuel Floor IVVI Activities Rev. 0
- Attachment 2OS2 ALARA Planning and Controls CAP DOCUMENTS Number Description or Title Date or Revision
- 869666 Higher Dose Rates Found in the Suppression Pool L2R12
- 1/21/2009
- 873749 Extra Dose Moving Control Rod Drive Boxes to the Refuel Floor
- 1/29/2009
- 874413 Increased Exposure Observed After Shielding Installed
- 1/30/2009
- PROCEDURES Number Description or Title Date or Revision
- MA-AA-716-017 Equipment Readiness and Reliability Revision 1
- OU-AA-101-1007 Outage Scope Control Revision 5
- WC-AA-101-1002 On Line Scheduling Process Revision 8
- MISCELLANEOUS Number Description or Title Date or Revision Assignment Number
- 804909-08 Access Control to Radiologically Significant Areas and ALARA Planning and Controls Self-Assessment Report 11/6/2008
- RADIATION WORK PERMITS REVIEWED Number Description or Title Date or Revision
- 10009369 ALARA Work-In-Progress Review: L2R12 Dry Well General Electric In-Service Inspection 1/23/2009
- 10009379
- Rev. 0
- 10009381 ALARA Plan: L2R12 Dry Well Safety Relief Valve Activities Rev. 0
- 10009386 ALARA Plan: L2R12 Dry Well Scaffolding Rev. 0
- 10009395 ALARA Plan: L2R12 Control Rod Drive Pull/Put Activities Rev. 0
- 10009412 ALARA Plan: L2R12 Reactor Vessel Disassembly/Reassembly Rev. 0
- Attachment 2PS1 Radioactive Gaseous And Liquid Effluent Treatment And Monitoring Systems PROCEDURES Number Description or Title Date or Revision
- CY-LA-170-000 Radioactive Effluent and Environmental Monitoring Programs
- Rev. 3
- Rev. 2
- CY-LA-170-200 Radioactive Effluent Controls Program
- Rev. 1
- CY-AA-170-310 Offsite Dose Calculation Manual Administration
- Rev. 2
- CY-LA-170-1100 Quality Assurance for Radiolo0gical Monitoring Programs
- Rev. 1
- CY-LA-170-2000 Annual Radioactive Effluent Release Report
- Rev. 2
- CY-LA-170-2100 Estimated Errors of Effluent Measurements
- Rev. 0
- Rev. 3
- CY-LA-170-4160 Radioactive Groundwater Protective Program Scheduling and Notification
- Rev. 1
- LOP-WX-32 Interim Radioactive Storage Facility General Use Procedure
- Rev. 10
- LRP-5820-30 Wide Range Gas Monitor Low Range Detector Calibration
- Rev. 6
- LRP-5820-30 Wide Range Gas Monitor Low Range Detector Calibration
- Rev. 7
- LRP-5820-31 Wide Range Gas Monitor Mid/ High Range Detector Calibration
- Rev. 9
- LRP-5820-31 Wide Range Gas Monitor Mid/ High Range Detector Calibration
- Rev. 10
- LRP-5820-33 Station Vent Stack and Standby Gas Treatment Stack Wide Range Gas Monitor Effluent Release Alarm and Trip Set-Points
- Rev. 2
- LRP-5820-34 Off-Gas Post Treatment Monitor Alarm and Trip Set-Points
- Rev. 10
- LS-AA-1120 Industry Groundwater Protection Initiative Voluntary Communication
- Rev. 10
- RP-AA-228 10
- CFR 75(g) and 10
- CFR 72.20 Documentation Requirements
- Rev. 0
- LCP-810-30 Gamma Spectrometer Systems Calibration
- Rev. 5
- CAP DOCUMENTS Number Description or Title Date or Revision
- 606826 Off-Gas Pre-Treat Sample Trouble Alarm Received in the Main Control Room 3/21/2007
- 627381 Potentially Degraded Barrels Identified 5/9/2007
- Attachment CAP DOCUMENTS Number Description or Title Date or Revision
- 641290 Declared Unit-1 WS Process Radiation Monitor Inoperable 6/17/2007
- 651040 Step Change in WS Radiation Monitor 7/18/2007
- 654533 Found Evidence of Oil Intrusion Inside the Stack Wide Range Gas Monitor Skid 7/27/2007
- 668677 Service Water Process Radiation Monitor Has No Flow 9/6/2007
- 707332-02 Radiological Groundwater Protection Program (Tritium Management) Focused Area Self-Assessment 12/16/2008
- 713026
- NOSA-LAS-08-04 Chemistry, Radwaste, Effluent and Environmental Monitoring Audit Report 4/2/2008
- 782742 Actions Needed to Address Source Detector Orientation 6/4/2008
- 792943 Unexpected Control Room Alarm: WS Effluent Radiation High 7/2/2008
- 821548 Unplanned Entry ODCM REC/TRM Action Statements - SVS Wide Range Gas Monitor 9/24/2008
- 839987 SVS Wide Range Gas Monitor Was Found Non-Isokinetic 11/4/2008
- 843954 Transition of Radiation Protection Setpoint Determination Procedures 11/12/2008
- 885878 Nuclear Oversight Identified Chemistry Focused Area Self-Assessment Issues 2/26/2009
- WORK ORDERS Number Description or Title Date or Revision
- WO 881152 Stand-by Gas Treatment System Wide Range Gas Monitor Calibration 6/27/2007
- WO 889083 Station Vent Monitor Stack Wide Range Gas Monitor
- 7/27/2007
- WO 996431 Stand-by Gas Treatment System Flow Rate Monitor Calibration
- 8/5/2008
- WO 998337 Main Stack Effluent and Sampler Flow Calibration
- 7/31/2008
- WO 1170747 Stand-by Gas Treatment System Wide Range Gas Monitor Calibration
- 12/22/2008
- WO 1180721 Station Vent Monitor Stack Wide Range Gas Monitor
- 1/12/2009
- MISCELLANEOUS Number Description or Title Date or Revision
- LaSalle County Station Update Final Safety Analysis Section 11 Rev. 13
- Attachment 4OA1 Performance Indicator Verification PROCEDURES Number Description or Title Date or Revision
- LS-AA-2010 Monthly Data Elements for NRC/WANO for Unit/Reactor Shutdown Occurrences July - December, 2008
- LS-AA-2030 Monthly Data Elements for NRC for Unplanned Power Changes per 7000 Critical Hours July - December, 2008
- MISCELLANEOUS Number Description or Title Date or Revision
- Performance Indicator Data for Unplanned Scrams per 7000 Critical Hours July - December, 2008
- Performance Indicator Data for Unplanned Power Changes per 7000 Critical Hours July - December, 2008
- Performance Indicator Data for Unplanned Power Fluctuations July - December, 2008
- 4OA2 Identification and Resolution of Problems PROCEDURES Number Description or Title Date or Revision
- LIS-PC-207B Unit 2 Post Accident Containment Hydrogen and Oxygen Monitoring System Panel 2PL77J (Div 2) Calibration and Gas Bottle Replacement Rev. 8
- LS-AA-2110 Monthly Data Elements for NRC Emergency Response Organization Drill Participation, Attachment 1 4/2008 - 9/2008
- LS-AA-2120 Monthly Data Elements for NRC Drill/Exercise Performance, Attachment 1 4/2008 - 9/2008
- LS-AA-2130 Monthly PI Elements for NRC Alert and Notification System Reliability, Attachment 1 4/2008 - 9/2008
- LOS-SC-R1 Unit 2 SBLC Injection Test Rev. 28
- CAP DOCUMENTS Number Description or Title Date or Revision
- 868501 Control Rod 34-59 Took 20 minutes to Insert
- 1/18/2009
- 871870 LPRM 40-09A Upscale 1/26/2009
- Attachment CAP DOCUMENTS Number Description or Title Date or Revision
- 872599 2B33-F345B Abnormal Indication When Opening 2/26/2009
- 870124 Broken Connector on 2C41-F004B 1/22/2009
- 2457 U-2 RCIC trip and Throttle Valve Failed to Trip 1/27/2009
- 874114 L2R12 2B21-F032A Disc Rotation 1/30/2009
- 874417 L2R12 LL Safety Relief Valve (SRV) Testing 1/30/2009
- 868937 Duct Tape found on CRD Line in Drywell 1/20/2009
- 2155 FME Found in Main Steam Piping During SrV Flange Inspection 1/26/2009
- 874692 Bonnet Cap Screws on Valve Torqued Higher than Required 1/31/2009
- 873406 2IN035 Required Adjustment During
- LOS-IN-R3 1/28/2009
- 872416 2B33-F344B Displayed Abnormal Indications in Open Direction 1/27/2009
- 874804 RF Pumpdown Functional Test Failed to Shutdown when Expected 2/1/2009
- 888664 Issues on Final Clear of 2FP136 3/3/2009
- 886819 2C CD/CB min Flow Failed Open, MCR Unexpected Alarm 2/28/2009
- MISCELLANEOUS Number Description or Title Date or Revision
- EP Memo, Designation of NRC DEP (Drill and Exercise Performance) Opportunities for LORT 07/06 - 08/06
- OPERABILITY EVALUATIONS Number Description or Title Date or Revision
- EC 373825 Evaluation of Lost Parts During L2R12 Rev. 0
- EC 374122 Pressure Regulator 2IN035, Evaluation of Lower Regulated Pressure Rev. 0
- WORK ORDERS Number Description or Title Date or Revision
- 1165382 Div II PA Containment 02 & H2 Mon Panel 2PL77J 11/11/2008
- 1191860 Div II PA Containment 02 & H2 Mon Panel 2PL77J 2/10/2009
- Attachment 4OA5 Other Activities CAP DOCUMENTS GENERATED DURING INSPECTION Number Description or Title Date or Revision
- 874097 NRC Identified Exposed Cable in Drywell 1/30/2009
- 878001 Minor Issues from U2 Drywell Closeout with NRC 2/8/2009
- 873789 NRC Identified Sparks Leaving Weld Area in LPHB during L2R12 1/29/2009
- 876842 NRC ID 2E12-F090A has small packing leak 2/5/2009
- 876846 NRC ID 2E12-F090B has one drop/minute leak 2/5/2009
- 876850 NRC ID 2E51-F063 has a one drop/minute packing leak 2/5/2009
- 882312 NRC ID - Minor surface corrosion on 1B RHRWS Line 2/18/2009
- 889612 Scaffold stacked higher than the storage rack 3/6/2009
- 890575 NRC ID - 1PL76J "Power on" Light Burned Out 3/9/2009
- Attachment
LIST OF ACRONYMS
- USED [[]]
- LO [[]]
- NRC [[]]
UFSAR Updated Final Safety Analysis Report
Attachment