November 10, 2021

SUBJECT:

JOSEPH M. FARLEY NUCLEAR PLANT - INTEGRATED INSPECTION REPORT 05000348/2021003, 05000364/2021003, AND 07200042/2021001

Dear Ms. Gayheart:

On September 30, 2021, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Joseph M. Farley Nuclear Plant. On October 18, 2021, the NRC inspectors discussed the results of this inspection with Charles Kharrl and other members of your staff.

The results of this inspection are documented in the enclosed report.

One finding of very low safety significance (Green) is documented in this report. This finding involved a violation of NRC requirements. We are treating this violation as a non-cited violation (NCV) consistent with Section 2.3.2 of the Enforcement Policy.

If you contest the violation or the significance or severity of the violation documented in this inspection report, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the U.S. Nuclear Regulatory Commission, ATTN:

Document Control Desk, Washington, DC 20555-0001; with copies to the Regional Administrator, Region II; the Director, Office of Enforcement; and the NRC Resident Inspector at Joseph M. Farley Nuclear Plant.

This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.

Sincerely,

/RA/

Alan J. Blamey, Chief Reactor Projects Branch 2 Division of Reactor Projects

Docket Nos. 05000348, 05000364, and 07200042 License Nos. NPF-2 and NPF-8

Enclosure:

As stated

Inspection Report

Docket Numbers:

05000348, 05000364, and 07200042

License Numbers:

NPF-2 and NPF-8

Report Numbers:

05000348/2021003, 05000364/2021003, and 07200042/2021001

Enterprise Identifier: I-2021-003-0009 and I-2021-001-0154

Licensee:

Southern Nuclear Company

Facility:

Joseph M. Farley Nuclear Plant

Location:

Columbia, AL

Inspection Dates:

July 01, 2021 to September 30, 2021

Inspectors:

D. Bacon, Senior Operations Engineer

P. Cooper, Senior Reactor Inspector

C. Fontana, Emergency Preparedness Inspector

D. Lanyi, Senior Operations Engineer

M. Learn, Transportation and Storage Inspector

P. Meier, Senior Resident Inspector

S. Sanchez, Senior Emergency Preparedness Inspector

S. Temple, Resident Inspector

J. Walker, Emergency Response Inspector

Approved By:

Alan J. Blamey, Chief

Reactor Projects Branch 2

Division of Reactor Projects

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees

performance by conducting an integrated inspection at Joseph M. Farley Nuclear Plant, in

accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs

program for overseeing the safe operation of commercial nuclear power reactors. Refer to

https://www.nrc.gov/reactors/operating/oversight.html for more information.

List of Findings and Violations

Failure to Incorporate Acceptance Criteria for the Spent Fuel Bridge Crane

Cornerstone

Significance

Cross-Cutting

Aspect

Report

Section

Mitigating

Systems

Green

NCV 05000348,05000364/2021003-01

Open/Closed

None (NPP)

60855

The inspectors identified a Green finding and associated non-cited violation (NCV) of 10 CFR Part 50, Appendix B, Criterion III, "Design Control," for the licensee's failure to assure that

applicable regulatory requirements and the design basis are correctly translated into

specifications, drawings, procedures, and instructions. Specifically, the licensee failed to

incorporate acceptance criteria for the Spent Fuel Bridge Crane lower runway and upper

railway into FNP-0-MP-30.3, Spent Fuel Cask Crane Periodic Mechanical Check, to ensure

it can respond to design basis events.

Additional Tracking Items

Type

Issue Number

Title

Report Section

Status

URI

05000348,05000364/20

21003-02

Cask Transfer Operations

Outside of the Fuel Handling

Building

60855

Open

PLANT STATUS

Unit 1 began the report period at approximately 100 percent rated thermal power (RTP) and

remained at or near 100 percent RTP through the end of the report period.

Unit 2 began the report period at approximately 100 percent RTP. On September 14, 2021,

power was reduced to approximately 90 percent RTP for turbine valve testing. Subsequently,

power was increased back to approximately 100 percent RTP on the same day, September 14,

2021, and remained at or near 100 percent RTP through the end of the report period.

INSPECTION SCOPES

Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in

effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with

their attached revision histories are located on the public website at http://www.nrc.gov/reading-

rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared

complete when the IP requirements most appropriate to the inspection activity were met

consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection

Program - Operations Phase. The inspectors reviewed selected procedures and records,

observed activities, and interviewed personnel to assess licensee performance and compliance

with Commission rules and regulations, license conditions, site procedures, and standards.

Starting on March 20, 2020, in response to the National Emergency declared by the President

of the United States on the public health risks of the coronavirus (COVID-19), resident and

regional inspectors were directed to begin telework and to remotely access licensee information

using available technology. During this time, the resident inspectors performed periodic site

visits each week, increasing the amount of time on site as local COVID-19 conditions permitted.

As part of their onsite activities, resident inspectors conducted plant status activities as

described in IMC 2515, Appendix D; observed risk significant activities; and completed on site

portions of IPs. In addition, resident and regional baseline inspections were evaluated to

determine if all or a portion of the objectives and requirements stated in the IP could be

performed remotely. If the inspections could be performed remotely, they were conducted per

the applicable IP. In some cases, portions of an IP were completed remotely and on site. The

inspections documented below met the objectives and requirements for completion of the IP.

REACTOR SAFETY

71111.01 - Adverse Weather Protection

External Flooding Sample (IP Section 03.03) (1 Sample)

(1)

The inspectors reviewed flood protection barriers, mitigation plans, procedures, and

equipment to verify they were consistent with the licensees design requirements and

risk analysis assumptions for coping with external flooding (FNP-0-AOP-21.0).

71111.04 - Equipment Alignment

Partial Walkdown Sample (IP Section 03.01) (4 Samples)

The inspectors evaluated system configurations during partial walkdowns of the following

systems/trains:

(1)

Unit 1 'B' emergency diesel generator with the 'A' air compressor cross-connected to

the 'B' air compressor while the 'B' air compressor back pressure valve was

inoperable on July 14, 2021 (CR 10812386, FNP-0-SOP-38.0, A181005, D170806)

(2)

Number 1 diesel driven fire pump and motor driven pump alignment during the

Number 2 diesel driven fire pump maintenance outage during the week of August 2,

2021 (Dwg D170366)

(3)

Unit 2 component cooling water system during the Unit 2 'A' component cooling water

pump quarterly test on September 2, 2021 (FNP-2-SOP-023, D205002)

(4)

Unit 1 'B' motor driven auxiliary system during the Unit 1 'A' motor driven auxiliary

system maintenance outage on September 8, 2021 (FNP-1-SOP-22.0, D175007)

Complete Walkdown Sample (IP Section 03.02) (1 Sample)

(1)

The inspectors evaluated system configurations during a complete walkdown of the

Unit 2 component cooling water system on August 26, 2021 (D205002, D205023,

FNP-2-SOP-023).

71111.05 - Fire Protection

Fire Area Walkdown and Inspection Sample (IP Section 03.01) (5 Samples)

The inspectors evaluated the implementation of the fire protection program by conducting a

walkdown and performing a review to verify program compliance, equipment functionality,

material condition, and operational readiness of the following fire areas:

(1)

'A' train emergency diesel generator switchgear room (fire zone DGB-56A)

on September 22, 2021

(2)

'B' train emergency diesel generator switchgear room (fire zone DGB-56B)

on September 22, 2021

(3)

Unit 1 turbine building (fire area 1-TB) on September 22, 2021

(4)

Control rod drive mechanism room (fire zone 346) on September 23, 2021

(5)

Unit 1 'A' motor control center area (fire zone 332) on September 23, 2021

71111.06 - Flood Protection Measures

Inspection Activities - Internal Flooding (IP Section 03.01) (1 Sample)

The inspectors evaluated internal flooding mitigation protections in the:

(1)

Unit 1 cable spreading room (calculation BM-99-1932-001, F-RIE-IF-U00-006)

71111.11B - Licensed Operator Requalification Program and Licensed Operator Performance

Licensed Operator Requalification Program (IP Section 03.04) (1 Sample)

(1)

Administration of an Annual Requalification Operating Test

The inspectors evaluated the effectiveness of the facility licensee in administering

requalification operating tests required by 10 CFR 55.59(a)(2) and that the facility

licensee is effectively evaluating their licensed operators for mastery of training

objectives.

Requalification Examination Security

The inspectors evaluated the ability of the facility licensee to safeguard examination

material, such that the examination is not compromised.

Control Room Simulator

The inspectors evaluated the adequacy of the facility licensees control room

simulator in modeling the actual plant, and for meeting the requirements contained in

10 CFR 55.46.

The inspectors completed the inspection sample that was partially completed during

the second quarter of 2020 due to pandemic related travel restrictions.

71111.11Q - Licensed Operator Requalification Program and Licensed Operator Performance

Licensed Operator Performance in the Actual Plant/Main Control Room (IP Section 03.01) (1

Sample)

1)

The inspectors observed and evaluated licensed operator performance in the control

room for the following activities (NMP-OS-007):

  • Unit 2 dilution and operator response to various control room alarms on

August 19, 2021

Unit 1 nuclear instrumentation calibration and testing and operator response

to associated alarms on September 9, 2021

Licensed Operator Requalification Training/Examinations (IP Section 03.02) (1 Sample)

(1)

The inspectors observed and evaluated operator training practice exercise on the

simulator involving a reactor trip and large break loss of coolant accident on July 27,

2021.

71111.12 - Maintenance Effectiveness

Maintenance Effectiveness (IP Section 03.01) (2 Samples)

The inspectors evaluated the effectiveness of maintenance to ensure the following

structures, systems, and components (SSCs) remain capable of performing their intended

function:

(1)

Unit 1 'C' charging pump balancing line leak identified on July 23, 2021 (condition

report (CR) 10815070)

(2)

Unit 2 anticipated transient without scram (ATWS) mitigation system actuation

circuitry (AMSAC) system indication issue identified on June 30, 2021 (CR 10719169)

71111.13 - Maintenance Risk Assessments and Emergent Work Control

Risk Assessment and Management Sample (IP Section 03.01) (4 Samples)

The inspectors evaluated the accuracy and completeness of risk assessments for the

following planned and emergent work activities to ensure configuration changes and

appropriate work controls were addressed:

(1)

Unit 1 'B' residual heat removal pump room cooler out of service for planned

maintenance resulting in yellow risk on July 6, 2021 (NMP-DP-001)

(2)

High voltage switchyard modification work coincident with the Unit 1 'A' residual heat

removal pump out of service for planned maintenance on July 13, 2021 (NMP-DP-

001; NMP-GM-021)

(3)

Unit 1 'C' service water 'B' train breaker cubicle work with the 'B' train supplying the in

service loads for the turbine building and reactor coolant pumps and the site

operating under a conservative system operating conditions due to high summer

temperatures on July 28, 2021 (NMP-DP-001)

(4)

Unit 1 risk with the 2C emergency diesel generator (station blackout generator)

unavailable and the 1D load center cooler out of service on August 23, 2021 (NMP-

DP-001)

71111.15 - Operability Determinations and Functionality Assessments

Operability Determination or Functionality Assessment (IP Section 03.01) (6 Samples)

The inspectors evaluated the licensee's justifications and actions associated with the

following operability determinations and functionality assessments:

(1)

Unit 1 'B' emergency diesel generator 'B' air receiver low pressure due to issues with

the 'B' emergency diesel generator air compressor identified on July 13, 2021 (CR

10812386)

(2)

Unit 1 turbine driven auxiliary feedwater pump due to issues with the 'A' emergency

air compressor identified on July 14, 2021 (CR 10812836)

(3)

Unit 1 'C' charging pump with a leaking balancing line due to a cracked weld identified

on July 23, 2021 (CR 10815070)

(4)

Unit 2 service water pumps 'C' and 'D' with lower motor bearing oil leaks identified on

August 13, 2021 (CRs 10820112 and 10820122)

(5)

1-2A emergency diesel generator turbo charger high oil level identified during a 24-

hour surveillance run on August 18, 2021 (CR 10821117)

(6)

Unit 2 'C' steam loop high flow calibration issue identified during a surveillance on

August 30, 2021 (CR 10823782)

71111.19 - Post-Maintenance Testing

Post-Maintenance Test Sample (IP Section 03.01) (9 Samples)

The inspectors evaluated the following post-maintenance test activities to verify system

operability and functionality:

(1)

1-2A emergency diesel generator roll-up fire door testing following fusible link

installations performed on May 10, 2021 (Work Order (WO) SNC1140375)

(2)

Unit 1 'B' residual heat removal pump inservice test following system maintenance on

July 8, 2021 (WO SNC1135115, FNP-1-STP-11.2)

(3)

Unit 2 turbine driven auxiliary feedwater system valve test following valve actuator

diaphragm replacement on July 8, 2021 (WO SNC1165861, FNP-2-STP-21.3)

(4)

Number 2 diesel fire pump battery testing following replacement on July 21, 2021

(WO SNC1044166)

(5)

Number 2 diesel driven fire pump functional test following a planned maintenance

outage on August 2 through August 6, 2021 (WO SNC1081516; FNP-0-FSP-203.6)

(6)

Unit 1 'C' charging pump testing following balancing line weld repair on August 13,

2021 (WO SNC1169344, FNP-1-STP-4.3)

(7)

Unit 2 'A' component cooling water pump testing following pump control room selector

switch replacement on September 2, 2021 (WO SNC1001934)

(8)

Unit 1 'C' service water pump 'B' electrical train breaker testing following racking

mechanism and breaker replacement on September 2, 2021 (WO SNC1153800,

FNP-SOP-24.0, FNP-0-SOP-36.6)

(9)

Unit 2 'B' component cooling water pump testing following valve and pump motor

routine maintenance on September 15, 2021 (WO SNC1146235, FNP-2-STP-23.2)

71111.22 - Surveillance Testing

The inspectors evaluated the following surveillance tests:

Surveillance Tests (other) (IP Section 03.01) (3 Samples)

(1)

Unit 1 'B' charging pump quarterly surveillance on July 30, 2021 (WO SNC1134098,

FNP-1-STP-4.2)

(2)

Unit 2 primary coolant system gross activity determination on September 16, 2021

(FNP-2-STP-741.0, FNP-2-CCP-651.1)

(3)

Unit 2 main turbine valve testing on September 14, 2021 (FNP-2-STP-62.0)

Inservice Testing (IP Section 03.01) (1 Sample)

(1)

Unit 2 'A' motor driven auxiliary feedwater pump quarterly in-service test on July 21,

2021 (FNP-2-STP-22.1)

FLEX Testing (IP Section 03.02) (1 Sample)

(1)

FLEX diesel generator testing (600V, 480V) on July 26, 2021 (WO SNC1102122,

SNC1101732)

71114.01 - Exercise Evaluation

Inspection Review (IP Section 02.01-02.11) (1 Sample)

(1)

The inspectors evaluated the biennial emergency plan exercise during the week of

September 20, 2021. The exercise scenario simulated an earthquake that caused

multiple alarms in the simulator control room, including a small fuel failure caused by

foreign material in the reactor vessel. This met the conditions for declaration of an

Unusual Event. A short time later, the 1A startup transformer tripped offline, followed

by a turbine generator trip (but no reactor trip, until tripped remotely), along with a trip

of the 1-2A emergency diesel generator, the 1B motor driven auxiliary feedwater

pump (AFWP), and the turbine driven AFWP. This resulted in a loss of heat sink and

met the conditions for declaration of a Site Area Emergency. Lastly, a containment

penetration failure created a pathway for a radiological release to the environment

and met the conditions for declaration of a General Emergency, which allowed the

Offsite Response Organizations to demonstrate their ability to implement emergency

actions. This exercise scenario also included a beyond design basis demonstration

related to feeding the steam generators from an alternate water supply.

71114.04 - Emergency Action Level and Emergency Plan Changes

Inspection Review (IP Section 02.01-02.03) (1 Sample)

(1)

The inspectors evaluated submitted Emergency Action Level, Emergency Plan, and

Emergency Plan Implementing Procedure changes during the week of September 20,

2021. This evaluation does not constitute NRC approval.

71114.08 - Exercise Evaluation Scenario Review

Inspection Review (IP Section 02.01 - 02.04) (1 Sample)

(1)

The inspectors reviewed and evaluated in-office, the proposed scenario for the

biennial emergency plan exercise at least 30 days prior to the day of the exercise.

OTHER ACTIVITIES - BASELINE

71151 - Performance Indicator Verification

The inspectors verified licensee performance indicators submittals listed below:

MS05: Safety System Functional Failures (SSFFs) Sample (IP Section 02.04) (2 Samples)

(1)

Unit 1 (July 1, 2020 through June 30, 2021)

(2)

Unit 2 (July 1, 2020 through June 30, 2021)

BI01: Reactor Coolant System (RCS) Specific Activity Sample (IP Section 02.10) (2 Samples)

(1)

Unit 1 (July 1, 2020 through June 30, 2021)

(2)

Unit 2 (July 1, 2020 through June 30, 2021)

BI02: RCS Leak Rate Sample (IP Section 02.11) (2 Samples)

(1)

Unit 1 (July 1, 2020 through June 30, 2021)

(2)

Unit 2 (July 1, 2020 through June 30, 2021)

EP01: Drill/Exercise Performance (DEP) Sample (IP Section 02.12) (1 Sample)

(1)

Unit 1 (July 1, 2020 through June 30, 2021)

Unit 2 (July 1, 2020 through June 30, 2021)

EP02: Emergency Response Organization (ERO) Drill Participation (IP Section 02.13) (1

Sample)

(1)

Unit 1 (July 1, 2020 through June 30, 2021)

Unit 2 (July 1, 2020 through June 30, 2021)

EP03: Alert And Notification System (ANS) Reliability Sample (IP Section 02.14) (1 Sample)

(1)

Unit 1 (July 1, 2020 through June 30, 2021)

Unit 2 (July 1, 2020 through June 30, 2021)

71152 - Problem Identification and Resolution

Semiannual Trend Review (IP Section 02.02) (1 Sample)

(1)

The inspectors reviewed the licensees corrective action program for potential

adverse trends from August 1, 2019 through July 31, 2021, associated with clappers

used in fire protection preaction sprinkler systems designated as high safety

significant that might be indicative of a more significant safety issue (CR1078284,

1074662).

Annual Follow-up of Selected Issues (IP Section 02.03) (2 Samples)

The inspectors reviewed the licensees implementation of its corrective action program

related to the following issues:

(1)

Unit 1 'C' service water pump 'B' train breaker racking failures and repairs from April

to September 2021. This issue was selected for review due to the multiple racking

issues, complicated repairs, and eventual replacement of the racking mechanism.

The scope of the review included verification of the licensees repair processes to

ensure timely corrective actions were taken and causal evaluations considered

equipment degradation (CRs 10790220, 10793414, 10816305).

(2)

A concern with the in-service testing classification of residual heat removal valves

potentially required while in mode 4. The issue was identified by the licensee via

industry operating experience and identified on August 26, 2021. This issue was

selected based on the safety significance of the residual heat removal system and to

review the licensee's response to industry operating experience (CRs 10823116,

10821309).

OTHER ACTIVITIES - TEMPORARY INSTRUCTIONS, INFREQUENT AND ABNORMAL

60855 - Operation Of An ISFSI

Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in

effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with

their attached revision histories are located on the public website at http://www.nrc.gov/reading-

rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared

complete when the IP requirements most appropriate to the inspection activity were met

consistent with Inspection Manual Chapter (IMC) 2690, Inspection Program for Storage of

Spent Reactor Fuel and Reactor-Related Greater-than-Class C Waste at Independent Spent

Fuel Storage Installations (ISFSI) and for 10 CFR Part 71 Transportation Packaging."

Operation Of An ISFSI (1 Sample)

(1)

Operation of an Independent Spent Fuel Storage Installation

From July 19 through July 23, 2021, the inspectors performed a review of the

licensees ISFSI activities to verify compliance with regulatory requirements. During

the on-site inspection, the inspectors observed and reviewed licensee activities in

each of the five safety focus areas including occupational exposure, public exposure,

fuel damage, confinement, and impact to plant operations.

The inspectors reviewed selected procedures and records, observed activities, and

interviewed personnel to assess licensee performance and compliance with

Commission rules and regulations, license conditions, site procedures, and

standards. Additionally, the inspectors performed independent walkdowns of the

heavy load lifting equipment and the ISFSI haul path. The inspector also performed

an independent radiation survey of the ISFSI pad.

INSPECTION RESULTS

Failure to Incorporate Acceptance Criteria for the Spent Fuel Bridge Crane

Cornerstone

Significance

Cross-Cutting

Aspect

Report

Section

Mitigating

Systems

Green

NCV 05000348,05000364/2021003-01

Open/Closed

None (NPP)

60855

The inspectors identified a Green finding and associated non-cited violation (NCV) of 10 CFR Part 50, Appendix B, Criterion III, "Design Control," for the licensee's failure to assure that

applicable regulatory requirements and the design basis are correctly translated into

specifications, drawings, procedures, and instructions. Specifically, the licensee failed to

incorporate acceptance criteria for the Spent Fuel Bridge Crane lower runway and upper

railway into FNP-0-MP-30.3, Spent Fuel Cask Crane Periodic Mechanical Check, to ensure

it can respond to design basis events.

Description: As described in UFSAR Section 9.1.4.3.2 Spent-Fuel Cask Crane Design

Evaluation, the spent-fuel cask crane is a Seismic Category I component and is designed to

withstand, without loss of load carrying function, the forces resulting from a safe shutdown

earthquake (SSE) when the crane is handling the full-rated load. The crane lower runway and

upper railway provide the structural foundation for the spent fuel cask crane to ensure the

crane design features will respond as designed to prevent a loss of function.

FNP-0-MP-30.3, Spent Fuel Cask Crane Periodic Mechanical Check, is the plant procedure

that establishes the periodic (yearly) maintenance checks to be performed on the Spent Fuel

Cask Crane. This procedure incorporates acceptance criteria associated with vendor

drawings U169215 and U169461 as well as calculation SC-SNC1137180-001. This

procedure also satisfies the Technical Requirements Manual (TRS 13.9.5.2) for periodic

checks and is credited for managing the aging effects of the crane and its associated

components. The inspectors identified two examples where the acceptance criteria were not

correctly translated into procedure FNP-0-MP-30.3 Spent Fuel Cask Crane Periodic

Maintenance Check.

The inspector identified the first example during the review of the licensees design equivalent

change package, SNC1137180 Cask Crane Degraded Runway Rail Clip Anchor Bolts. This

package modified the lower runway by adding stainless-steel anchor bolts to support the

carbon steel bolts that could no longer perform their intended function and to subsequently

submerge the rail bolts and clips in a concrete/grout mixture. The modification of the lower

runway to include dissimilar metals introduced the potential for galvanic corrosion if the

components were to become wet. The inspector identified that the procedure FNP-0-MP-

30.3, Spent Fuel Cask Crane Periodic Mechanical Check, did not include acceptance

criteria to identify areas of water intrusion to prevent the potential for unmonitored

degradation of the lower runway. Additionally, FNP-0-MP-30.3, Spent Fuel Cask Crane

Periodic Mechanical Check, also implements the aging management program Overhead

and Refueling Crane Inspection Program, (UFSAR Section 18.2.7) which requires the

inspection for loss of preload of the spent fuel bridge crane rail clips and bolting. The

inspector identified that by submerging the rail clips and bolting in the concrete/grout mixture,

the current inspection method to look for loose and missing fasteners would no longer be

applicable. As a result, the licensee failed to include an alternative acceptance criteria or

alternative inspection method to identify the loss of preload of the lower runway rail clips and

bolting.

The inspector identified the second example when comparing the as found condition of the

upper railway, the spent fuel cask crane design drawings, and the criteria described

in procedure FNP-0-MP-30.3, Spent Fuel Cask Crane Periodic Mechanical Check. When

reviewing the FNP-0-MP-30.3, Spent Fuel Cask Crane Periodic Mechanical Check, the

inspector noted that Step 4.29, Upper Railway, states to check the rail fasteners for proper

installation and condition. However, the procedure did not include any acceptance criteria to

accomplish this step, such as the minimum required thread engagement. Through interviews

with plant personnel, it was noted that skill of the craft was used to identify deficiencies.

During a walkdown of the upper railway the inspector identified several crane rail bolts and

fasteners had less than 50% thread engagement which was contrary to the design drawings

of 100% thread engagement. The licensee reviewed past inspection results and identified

that the lack of thread engagement was previously identified and entered into the corrective

action program in 2005. However, the deficiency of having approximately 30% of the rail clips

and bolting with less than 100% thread engagement had not been evaluated.

The inspector concluded that the deficiency had not been subsequently identified by FNP-0-

MP-30.3, Spent Fuel Cask Crane Periodic Mechanical Check, due to the lack of acceptance

criteria within the procedure. Had the procedure had the specific acceptance criteria, it is the

inspectors position that the deficiency would have been identified in the subsequent yearly

inspections and would have prevented the crane from being used while in an unanalyzed

configuration.

Corrective Actions: The licensee performed a preliminary evaluation, assuming a minimum of

two threads of engagement, and determined the crane runway and railway could continue to

perform its intended function.

Corrective Action References: CR 10815116 and CR 10815118

Performance Assessment:

Performance Deficiency: The inspector determined that the licensee failure to incorporate

acceptance criteria for the Spent Fuel Bridge Crane lower runway and upper railway into

FNP-0-MP-30.3, Spent Fuel Cask Crane Periodic Mechanical Check, to ensure it can

respond to design basis events was a performance deficiency.

Screening: The inspectors determined the performance deficiency was more than minor

because if left uncorrected, it would have the potential to lead to a more significant safety

concern. Specifically, the failure to identify deficiencies of the rail clip fasteners could

compromise the cranes ability to withstand, without loss of load carrying function, the forces

resulting from an SSE when the crane is handling the full-rated load.

Significance: The inspectors assessed the significance of the finding using Appendix A, The

Significance Determination Process (SDP) for Findings At-Power. The inspector determined

the finding to be of very low safety significance (Green) because it did not represent an actual

loss of function of one or more non-technical specification trains of equipment designated as

high safety-significant in accordance with the licensees maintenance rule program for

greater than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

Cross-Cutting Aspect: Not Present Performance. No cross-cutting aspect was assigned to

this finding because the inspectors determined the finding did not reflect present licensee

performance.

Enforcement:

Violation: 10 CFR Part 50, Appendix B, Criterion III, requires in part that measures shall be

established to assure that applicable regulatory requirements and the design basis, are

correctly translated into procedures, and instructions.

Contrary to the above, the licensee failed to ensure that applicable regulatory requirements

and the design basis were correctly translated into specifications, drawings, procedures, and

instructions. Specifically, the acceptance criteria that ensures the cranes ability to withstand,

without loss of load carrying function, the forces resulting from an SSE when the crane is

handling the full-rated load supports was not incorporated for the lower runway and upper

railway into inspection procedure FNP-0-MP-30.3 Spent Fuel Cask Crane Periodic

Maintenance Check.

Enforcement Action: This violation is being treated as a non-cited violation, consistent with

Section 2.3.2 of the Enforcement Policy.

Unresolved Item

(Open)

Cask Transfer Operations Outside of the Fuel Handling

Building

URI 05000348,05000364/2021003-02

60855

Description: The inspectors are reviewing information related to an issue of concern related

to 10 CFR 72.48 associated with the licensees decision to mitigate the potential for tornado

missiles from striking an MPC in a HI-STORM with the HI-STORM lid removed, through a

combination of administrative controls rather than design against the effects of natural

phenomena as required by 10 CFR 72.122 (b)(6).

10 CFR 72.212 (b)(6), states that the general licensee must, review the Safety Analysis

Report referenced in the Certificate of Compliance (CoC) or amended CoC and the related

NRC Safety Evaluation Report, prior to use of the general license, to determine whether or

not the reactor site parameters, including analyses of earthquake intensity and tornado

missiles, are enveloped by the cask design bases considered in these reports. The

inspectors reviewed the Joseph M. Farley Nuclear Plant Independent Spent Fuel Storage

Installation, 10 CFR 72.212 Report, (72.212 report) and identified that in section 7.2.c

Tornados, the licensee states that...the multi-purpose canister (MPC) transfer operations

are performed in the east alleyway behind the auxiliary building using equipment governed by

the requirements of Part 50. Additionally, the 72.212 report states...to minimize the

potential for a tornado missile to impact the HI-TRAC 125 or HI-STORM 100 during MPC

transfer operations, a loaded HI-TRAC 125 transfer cask will not be moved outside the FNP

auxiliary building during inclement weather. The inspectors identified that since this operation

is performed outside the fuel handling building, the HI-STORM and MPC within the HI-

STORM is subject to natural phenomena, such as tornados.

Additionally, during transfer operation with the MPC lid removed, the inspector identified that

the HI-STORM is in a configuration that is different than that discussed in the HI-STORM

100 Safety Analysis Report, HI-2002444 (HI-STORM FSAR), Section 11.2.6.2 Tornado

Analysis, and Section 3.1.4.8 Tornado Missile Evaluation. The inspectors noted that

NUREG-2215, Section 4.5.3.3.3, states that, the NRC does not accept the presumption that

there will be sufficient warning of tornadoes so that operations, such as transfer between the

fuel transfer facility and storage site, may never be exposed to tornado effects.

This unresolved item is being opened, as it relates to the licensees approach to use

administrative controls in lieu of performing a deterministic evaluation, to determine if:

the licensee has adequately reviewed the Safety Analysis Report referenced in the

CoC or amended CoC and the related NRC Safety Evaluation Report, to determine

whether or not the reactor site parameters, including analyses of tornado missiles, are

enveloped by the cask design bases considered in these reports.

the licensee is in compliance with 10 CFR 72.48.

other onsite ISFSI operations utilize a similar approach to evaluation.

Planned Closure Actions: Region II will coordinate with the Division of Fuel Management in

the NRC Office of Nuclear Materials Safety and Safeguards and with the licensee to discuss

and evaluate additional information.

EXIT MEETINGS AND DEBRIEFS

The inspectors verified no proprietary information was retained or documented in this report.

Exercise Inspection results to Mr. D. Erb and other members of the licensee staff.

On October 18, 2021, the inspectors presented the integrated inspection results to Mr.

Charles Kharrl and other members of the licensee staff.