IR 05000346/2022403

From kanterella
Jump to navigation Jump to search
– Security Baseline Inspection Report 05000346/2022403
ML23020A138
Person / Time
Site: Davis Besse 
(NPF-003)
Issue date: 01/23/2023
From: Steven Orth
NRC/RGN-III/DRSS
To: Tony Brown
Energy Harbor Nuclear Corp
References
IR 2022403
Download: ML23020A138 (1)


Text

SUBJECT:

DAVIS-BESSE NUCLEAR POWER STATION - SECURITY BASELINE INSPECTION REPORT 05000346/2022403

Dear Terry Brown:

On December 31, 2022, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Davis-Besse Nuclear Power Station. On January 12, 2023, the NRC inspectors discussed the results of this inspection with you and other members of your staff. The results of this inspection are documented in the enclosed report.

No findings or violations of more than minor significance were identified during this inspection.

This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.

Sincerely, Steven K. Orth, Chief Security, Emergency Preparedness, & Incident Response Branch Division of Radiological Safety and Security Docket No. 05000346 License No. NPF-3

Enclosure:

As stated

Inspection Report

Docket Number:

05000346

License Number:

NPF-3

Report Number:

05000346/2022403

Enterprise Identifier:

I-2022-403-0035

Licensee:

Energy Harbor Nuclear Corp.

Facility:

Davis-Besse Nuclear Power Station

Location:

Oak Harbor, OH

Inspection Dates:

November 01, 2022 to December 31, 2022

Inspectors:

N. Egan, Sr Physical Security Inspector

M. Ziolkowski, Sr Physical Security Inspector

Approved By:

Steven K. Orth, Chief

Security, Emergency Preparedness & Incident Response Branch

Division of Radiological Safety and Security

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting a security baseline inspection at Davis-Besse Nuclear Power Station, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors.

Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.

List of Findings and Violations

No findings or violations of more than minor significance were identified.

Additional Tracking Items

None.

INSPECTION SCOPES

Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2201, Security Inspection Program for Commercial Nuclear Power Reactors. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.

SAFEGUARDS

71130.04 - Equipment Performance, Testing, and Maintenance

The inspectors evaluated the security equipment testing and maintenance program. The following elements were evaluated:

Equipment Performance, Testing, and Maintenance (1 Sample)

(1) Tier I: All requirements

Tier II: 02.09 (a), 02.11 (c-d), 02.13

(a) Tier III: 02.15 (a-b)

71130.09 - Security Plan Changes

The inspectors evaluated the security plan changes through completion of the following procedure elements:

Security Plan Changes (1 Partial)

(1)

(Partial)

The opportunity to apply this procedure was not available in accordance with Inspection Manual Chapter 0306. This sample was not available because the licensee did not conduct the activity covered by this IP. Specifically, the licensee has not initiated a physical security plan change in accordance with Title 10 of the Code of Federal Regulations, Part 50.54(p)(2) since the implementation of this IP.

71130.14 - Review of Power Reactor Target Sets

The inspectors evaluated the Security Target Set Program. The following elements were evaluated:

Review of Power Reactor Target Sets

(1)02.02 (a-d); 02.03; 02.04; (a-b);

OTHER ACTIVITIES - BASELINE

===71151 - Performance Indicator Verification The inspectors verified licensee performance indicators submittals listed below:

PP01: Protected Area Security Equipment Performance Index Sample (IP Section 02.17)

=

(1) September 1, 2021 through September 1,

INSPECTION RESULTS

No findings were identified.

EXIT MEETINGS AND DEBRIEFS

The inspectors verified no proprietary information was retained or documented in this report.

On January 12, 2023, the inspectors presented the security baseline inspection results to Terry Brown and other members of the licensee staff.

DOCUMENTS REVIEWED

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

CR-2022-08837

NRC Equipment Inspection - Weekly Performance Testing

11/17/2022

Corrective Action

Documents

Resulting from

Inspection

CR-2022-08838

NRC Equipment Inspection: Early Warning System

11/17/2022

IS-DP-004001

Operational Test for Walk-Through Metal Detector

IS-DP-004002

Performance Test for the Walk-Through Metal Detector

IS-DP-004003

Performance Test for the X-Ray Device

IS-DP-004005

Performance and Operational Test for the Walk-Through

Explosive Detector

IS-DP-004011

Inspection of the Passive Vehicle Barrier System

IS-DP-00501

Testing and Maintenance of Security Systems

IS-DP-00503

Security Communications

IS-DP-00513

Weapons Program

IS-DP-04013

Quarterly Testing of the Hand Geometry Readers and the

Red Hot Buttons

IS-DP-04016

Semi-Automatic Rifle Inspection

IS-DP-04018

Operability Testing of X-Ray Devices

IS-DP-04021

Performance and Operability Testing of Itemizer

IS-DP-04907

Intrusion Detection Equipment

IS-DP-04917

Weekly IDS and Active VBS Operability Testing

IS-DP-04920

Nuclear Security Weekly Operability Testing

IS-DP-04922

Quarterly Testing of Security Alarms and Tampers

IS-DP-04931

ROCA Intrusion Detection Equipment

IS-DP-04933

Annual ROCA Alarms and Tampers Test

Procedures

IS-DP-04934

Monthly ROCA Operability Test

71130.04

Work Orders

DB-ME4001-001

SB Capacity Test Battery SB Capacity Test

10/31/2018

71130.09

Miscellaneous

Physical Security Plan, Training and Qualification Plan, and

Safeguards Contingency Plan, for the Davis-Besse Nuclear

Power Station

71130.14

Corrective Action

Documents

Resulting from

CR-2022-08831

NRC Target Set Inspection

11/17/2022

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

Inspection

Miscellaneous

Davis Besse Target Set Manual

NOP-1101-05

Security Periodic Review, Target Set Manual

2/08/2021

NOP-CC-204

Design Interface Reviews and Evaluations

Procedures

NOP-LP-1106

Target Set Programs

Self-Assessments

ATA-2022-17779

NRC Inspection 71130.14, Davis Besse Target Set

Inspection

11/08/2022