SUBJECT:
DAVIS-BESSE NUCLEAR POWER STATION - PHASE III 71003 LICENSE RENEWAL REPORT 05000346/2022012
Dear Mr. Brown:
On June 13, 2022, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Davis-Besse Nuclear Power Station and discussed the results of this inspection with you and other members of your staff. The results of this inspection are documented in the enclosed report.
No findings or violations of more than minor significance were identified during this inspection.
This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.
Sincerely, Néstor J. Feliz-Adorno, Chief Engineering Branch 1 Division of Reactor Safety Docket No. 05000346 License No. NPF-3
Enclosure:
As stated
Inspection Report
Docket Number:
05000346
License Number:
Report Number:
Enterprise Identifier:
I-2022-012-0016
Licensee:
Energy Harbor Nuclear Corporation
Facility:
Davis-Besse Nuclear Power Station
Location:
Oak Harbor, OH
Inspection Dates:
June 06, 2022 to June 10, 2022
Inspectors:
J. Bozga, Senior Reactor Inspector
E. Fernandez, Reactor Inspector
Approved By:
Néstor J. Feliz-Adorno, Chief
Engineering Branch 1
Division of Reactor Safety
SUMMARY
The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting a Phase III 71003 License Renewal at Davis-Besse Nuclear Power Station, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors.
Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.
List of Findings and Violations
No findings or violations of more than minor significance were identified.
Additional Tracking Items
None.
INSPECTION SCOPES
Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.
OTHER ACTIVITIES
- TEMPORARY INSTRUCTIONS, INFREQUENT AND ABNORMAL
71003 - Post-Approval Site Inspection for License Renewal Post-Approval Site Inspection for License Renewal
- (1) Post-Approval Site Inspection for License Renewal (Phase III) - Inspection Procedure 71003
a. Inspection Scope
Review of Commitment Items that Remained Open During the Phase II Inspection As documented in the U.S. Nuclear Regulatory Commission (NRC)
Post-Approval Site Inspection for License Renewal (Phase II) inspection report (IR) 05000346/2017009 (ML17083A802), Commitment Items 12, 20, 21, 37, 42, 51, and 53 remained open for various reasons. The inspectors reviewed closure documents including correspondence letters with the Office of Nuclear Reactor Regulation (NRR), 50.59 regulatory evaluations, procedures, corrective action documents, completed surveillance records, work orders, and conducted interviews to verify the licensee completed the necessary actions for the closure of these commitments.
1. Masonry Wall Program, Commitment Item 12:
The Masonry Wall Inspection Program is an existing program that, with enhancements, is comparable to the program described in NUREG-1801,Section XI.S5, Masonry Wall Program. The program is implemented as part of the Structural Monitoring Program (SMP) and consists of inspection activities to detect age-related degradation for masonry walls within the scope of license renewal.
During the Phase II inspection, inspectors noted some of the masonry wall inspections and periodic maintenance (PM) tasks were not completed as described in Commitment Item 12. During this Phase IIII inspection, the inspectors verified that the licensee has since completed the applicable masonry wall inspections and PM tasks. The inspectors did not identify any concern with the licensees implementation of Commitment Item 12.
2. Structures Monitoring Program, Commitment Item 20:
The SMP is an existing program that, with enhancements, is comparable to the program described in NUREG-1801,Section XI.S6, Structures Monitoring.
The program consists of periodic walkdowns of plant structures to determine any adverse aging effects on the structures or structural components within the scope of the license renewal.
During the Phase II inspection, inspectors noted some of the structures monitoring program inspections and PM tasks were not completed as described in Commitment Item 20. During this Phase III inspection, the inspectors verified that the licensee has since completed the applicable structures monitoring program inspections and PM tasks. The inspectors did not identify any concern with the licensees implementation of Commitment Item 20.
3. Water Control Structures Inspection Program, Commitment Item 21:
The Water Control Structures Inspection Program is an existing program comparable, with exceptions and enhancements, to the program described in NUREG-1801,Section XI.S7, RG [Regulatory Guide]1.127, Inspection of Water Control Structures Associated with Nuclear Power Plants. The program is implemented as part of the SMP and monitors age-related degradation of the intake structure, fore bay, service water discharge structure, and structural components within the structures.
During the Phase II inspection, inspectors noted some of the water control structures inspection program inspections and PM tasks were not completed as described in Commitment Item 21. During this Phase III inspection, the inspectors verified that the licensee has since completed the applicable water structures inspection program inspections and PM tasks. The inspectors did not identify any concern with the licensees implementation of Commitment Item 21.
4. Core Bores for Impact of Spent Fuel Pool Leakage, Commitment Item 37:
Commitment Item 37, associated with the SMP, involved performing and evaluating core bores of Emergency Core Cooling System Pump Room 1 wall and Room 109 ceiling. The commitment also involved a visual examination of the reinforcing core bore steel and a petrographic examination of the core bore concrete. The first set of core bores was performed in 2014 and the second set of core bores was performed in 2021.
The second set of core bores had not been performed by the time the Phase II inspection was completed. The licensee has since performed the visual and petrographic examination of the second set of core bores. During this Phase III inspection, the inspectors reviewed the information and noted that the licensee did not identify degradation of the concrete or reinforcing steel that affected structural integrity. The inspectors did not identify any concern with the licensees implementation of Commitment Item 37.
5. Fatigue Monitoring Program, Commitment Item 42:
The Fatigue Monitoring Program manages fatigue of primary and secondary components, including the reactor vessel, reactor internals, pressurizer, and steam generators by tracking thermal cycles as required by Technical Specifications 5.5.5, Component Cyclic or Transient Limit. The licensee committed to enhance the Fatigue Monitoring Program by evaluating additional plant-specific component locations in the reactor coolant pressure boundary that may be more limiting than those considered in NUREG/CR-6260. This evaluation included identification of the most limiting fatigue location exposed to reactor coolant for each material type. It also intended to evaluate nickel-based alloy items using NUREG/CR-6909 and the effects of the reactor coolant environment on fatigue usage for each bounding material/location.
During the Phase II inspection, the inspectors noted the licensee had submitted to NRR an evaluation to meet Commitment Item 42 prior to the period of extended operation. However, the NRR review was still ongoing at the time of the Phase II inspection. On August 8, 2017, in letter from NRR to FirstEnergy Nuclear Operating Company (FENOC) (ML17219A018), the NRC staff stated it completed its review and did not identify any issues. The NRC staff determined the actions required by Commitment Item 42 have been completed. The inspectors did not identify any concern with the licensees implementation of Commitment Item 42.
6. Service Level III Coatings and Linings Monitoring Program, Commitment
Item 51:
The Service Level III Coatings and Linings Monitoring Program is a new plant-specific Condition Monitoring Program. It consists of periodic visual inspections of all Service Level III coatings and linings on the internal surfaces of piping, piping components, and tanks in mechanical fluid systems that are within the scope of license renewal.
During the Phase II inspection, the inspectors identified the licensee had improperly excluded a population of in-scope valves from inspection. Since then, the licensee completed additional inspections of in-scope valves except for two service water valves. The licensee performed a 50.59 regulatory evaluation to address the baseline inspection of these service water valves which were not completed prior to the period of extended operation. The inspectors, in consultation with NRR, reviewed the 50.59 regulatory evaluation and did not identify any concerns with implementing the change without prior NRC approval.
The inspectors did not identify any concern with the licensees implementation of Commitment Item 51.
7. Pressurized Water Reactor Vessel Internals Program, Commitment Item 53:
The pressurized water reactor (PWR) Reactor Vessel Internals (RVIs)
Program manages the effects of age-related degradation mechanisms that are applicable in general to the PWR RVI components at Davis-Besse, a Babcock and Wilcox (B & W) designed plant. These aging effects include:
- (a) various forms of cracking, including stress corrosion cracking (SCC), which also encompasses primary water SCC, irradiation-assisted SCC or cracking due to fatigue/cyclical loading;
- (b) loss of material induced by wear;
- (c) loss of fracture toughness due to either thermal aging or neutron irradiation embrittlement; and
- (d) loss of preload due to thermal and irradiation-enhanced stress relaxation or creep.
During the Phase II inspection, the inspectors noted the licensee needed to submit a plant-specific analysis of applicable RVI component items to the NRC for review and approval. The analysis was to be submitted 1 year prior to the inspection of Materials Reliability Program MRP-227-A, Pressurized Water Reactor Internals Inspection and Evaluation Guidelines, of the applicable component items. The licensee submitted the analysis to the NRC for review and approval after the period of extended operation. On December 9, 2021, in letter from NRR to Energy Harbor Nuclear Corporation (ML21322A289), the NRC staff completed its review and concluded that the analysis was approved and Commitment Item 53 was fulfilled.
During the Phase III inspection, the inspectors did not identify any concern with the licensees implementation of Commitment Item
INSPECTION RESULTS
No findings were identified.
EXIT MEETINGS AND DEBRIEFS
The inspectors verified no proprietary information was retained or documented in this report.
On June 13, 2022, the inspectors presented the Phase III 71003 License Renewal results to Terry Brown, Site Vice President and other members of the licensee staff.
DOCUMENTS REVIEWED
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
Calculations
2-9140671-000
Environmentally Assisted Fatigue Cumulative Usage Factor
for the Reactor Vessel IMS Nozzles
04/13/2009
2017-01485
NRC LR PH2: Implementation of Commitment 51 - Service
Level Ill Coatings and Linings Monitoring Program
2/09/2017
22-01281
22 License Renew Phase III-IV Inspection Self
Assessment: Structures Monitoring Tracking Updates
Needed
2/18/2022
22-01420
lncomplete Service Level 3 Coating Inspections - 2022 LR
Phase II Open Items
2/23/2022
22-02445
1R22 - Baffle to Former Bolt (ID 1258) - Recordable
Indication
04/16/2022
Corrective Action
Documents
ATA-2021-15032
Self Assessment for Post-Approval Site Inspection for
License Renewal (Phase 3 & 4)
10/20/2021
Commitment 42 - Regarding the Limiting Components for
Nickel-Base Alloys and Low Alloy Steels for Environmentally
Assisted Fatigue
05/12/2017
2-9119659-001
Final Reports DB-1 Hot Leg Surge Nozzle and Pressurizer
Surge Nozzle EAF Analysis for License Renewal
08/30/2013
ANP-3438NP
ANP-3438NPMRP-227-A Applicant Item 7 Analysis for Davis
Besse Power Station Unit No. 1, Technical Report
Engineering
Evaluations
Commitment 42 - Regarding Component Locations that May
Be More Limiting and Replacements ( or Non-Replacement)
of the Elbows for HPI Nozzles
2/22/2017
50.59 Screening
No. 18-00014
USAR Section 18.1.44
01/11/2018
50.59 Screening
No. 20-01647
License Renewal Commitment Due Date Extension
2/11/2020
50.59 Screening
No. 22-00690
Service Level Ill Coating Baseline Inspection
06/01/2022
71003
Miscellaneous
Letter from Brian
D. Boles
(FENOC) to U.S.
Reply to Request for Additional Information Related to
License Renewal Commitment No. 42
05/12/2017
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
Nuclear
Regulatory
Commission
Letter from Brian
D. Boles
(FENOC) to U.S.
Nuclear
Regulatory
Commission
Reply to Request for Additional Information Related to
License Renewal Commitment No. 42
2/22/2017
Letter from Terry
J. Brown (Site
Vice President,
Davis-Besse
Nuclear) to U.S.
Nuclear
Regulatory
Commission
Submittal of MRP-227-A Applicant/Licensee Action Item 7
Analysis for Davis-Besse Nuclear Power Station Unit No. 1
03/10/2021
Report No.
000110
Petrographic Examination of Concrete Cores from
Davis-Besse Nuclear Power Plant, Oak Harbor, Ohio
03/26/2021
EN-DP-00355
Determination of Allowable Operating Transient Cycles
EN-DP-01511
Structures Monitoring
Procedures
NOP-CC-5004
Pressurized Water Reactor Vessel Internals Program
6