Text
-
..
_
.
.,
.. ~. ~
,
I
.
,
U.S. NUCLEAR REGULATORY COMMISSION
REGION III
l Report No. 50-341/90012(DRSS)
Docket No. 50-341 License No. NPF-43 Licensee: Detroit Ediso.1 Company 2200 Second Avenue Detroit, MI 48226
Facility Name:
Fermi 2 Atomic rowe+ Plant.
Inspection At:
Plant Site Inspection Dates: August 27-31, 1990
Inspector: 9 k k tf T[NIO J. 1. Belanger Date
'
'
Senior Physical Security Approved By: 9 d &#MJ1 M
'7//S/PC Janies R. Creed " Chief Date j
Sareguards Section Inspection Summary Inspection on August 27-31, 1990 (Report No. 50-341/90012(DRSS))
hreas Inspected:
Routine unannounced physical security inspection involving Alarm Stations and Communications; Power Supply; and Security Training and-Qualification. The inspection also covered followup on previous inspection findings.
Results: The licensee was found to be in compliance with NRC requirements within the areas examined. One previously. identified open item relating to security training records and personnel files is considered closed (341/89-031-03(DRSS)).
The inspector concluded that the security program is being well implemented and is well managed. The experience level (of the security force) due to low turnover is considered a program strength. Although the licensee's training and qualificatir'. program meets regulatory requirements, the
-
licensee's training sect'.on has identified the need for hands-on tactical I
response training for its instructors. Tactical response training.for the
'
security force has been limited because of the inexperience of the training staff.
l
)
Enclorure Contains; SAFRCUARDS INFO.'tKi? ION Upon Separation Thia Page Is Decontrolled 9009190123 900913 I
PDR ADOCK 0500
I O
s