IR 05000313/1986034

From kanterella
Jump to navigation Jump to search
Partially Withheld Insp Repts 50-313/86-34 & 50-368/86-34 on 861006-10 (Ref 10CFR73.21).Violations Noted:Inadequate Safeguards Contingency Plan Implementation & Inadequate Physical Barriers
ML20215D229
Person / Time
Site: Arkansas Nuclear  
Issue date: 11/28/1986
From: Caldwell R, Earnest A, Joseph Kelly, Yandell L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
Shared Package
ML20215D225 List:
References
50-313-86-34, 50-368-86-34, NUDOCS 8612160283
Download: ML20215D229 (2)


Text

(

.

' APPENDIX B

'

U.S. NUCLEAR REGULATORY COMMISSION

REGION IV

,

~

NRC Inspection Report:

50-313/86-34 Licenses:

DPR-51 50-368/86-34 NPF-6 Dockets:

50-313 50-368 Licensee:

Arkansas Power and Light Company (AP&L)

P.O. Box 55L Little Rock, Arkansas 72203

.

Facility Name:

Arkansas Nuclear One (ANO), Units 1 and 2 Inspection'At:

Russellville, Arkansas

~

Inspection Conducted:

October 6-10, 1986 Inspectors:

w

-

Cb Mobn sl $

J.F.. Kelly p enior Secur A Inspector Date E

ency Preparedness a(d Safeguards rograms Section

-

_

(lM O\\

CL ud

.

82hM M R. n. Caldwell, Phys I al Security Irispector Date EmergencyPreparednegandSafeguards Programs Section 6Eaoa at un htW m

A. B. Earnest, Phys' pal Security Inspector Date'

Emergency Preparedntes and Safeguards Programs Section

'

Approved:

On 2( b\\'Eh L. A. Tandell, Chief, Emergency Preparedness Date'~

and Safeguards Programs Section l

ENCLOSURE CONTAINS

,

1210 '

861g1 O hooog3 UPON SEPARATION THIS

,

,

p PAGE IS DECONTROLLED.

l PDR

-

.

-.. -

.n.__.__-____.____.-_.,.

,

.

'

-2-Inspection Summary Inspection Conducted October 6-10, 1986 (Report 50-313/86-34 and 50-368/86-34)

Areas Inspected:

Routine, unannounced inspection of the safeguards contingency plan (SCP), physical barriers - vital area (VA), security organization, compensatory measures, security training and qualification (T and Q), access control - vehicles, and access control personnel.

Results:

Of the seven areas inspected, two violations were identified (inadequate safeguards contingency plan implementation, paragraph 2; and inadequate physical barriers - VA, paragraph 3).

ENCLOSURE CONTAINS SAFEGUARDS INr3GIATION.

UPON SEPAfM1'ON THIS PAGE IS GEO' W'.t. LED.

._

_

_

. -.

_ _

- -_. _

..

.

-

.