June 15, 2022
SUBJECT:
REED COLLEGE - U.S. NUCLEAR REGULATORY COMMISSION ROUTINE SAFETY INSPECTION REPORT NO. 05000288/2022202
Dear Mr. Newhouse:
From April 25-27, 2022, the U.S. Nuclear Regulatory Commission (NRC) staff conducted an inspection at the Reed Research Reactor facility. The enclosed report presents the results of that inspection, which were discussed on April 27, 2022, with you and members of your staff.
The inspection examined activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license.
The inspector reviewed selected procedures and records, observed various activities, and interviewed personnel. Based on the results of this inspection, no findings of significance were identified. No response to this letter is required.
In accordance with Title 10 of the Code of Federal Regulations Section 2.390, Public inspections, exemptions, requests for withholding, a copy of this letter, its enclosure, and your response (if any) will be available electronically for public inspection in the NRC Public Document Room or from the NRCs document system (Agencywide Documents Access and Management System (ADAMS)). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). If you have any questions concerning this inspection, please contact Kevin Roche at (301) 415-1554, or by electronic mail at Kevin.Roche@nrc.gov.
Sincerely, Travis L. Tate, Chief Non-Power Production and Utilization Facility Oversight Branch Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation
Docket No. 50-288 License No. R-112
Enclosure:
As stated
cc: w/enclosure: See next page
Reed College
Docket No. 50-288
cc:
Mayor of the City of Portland 1220 Southwest 5th Avenue Portland, OR 97204
Dr. Kathryn C. Olsen, Dean of Faculty Reed College 3203 SE Woodstock Boulevard Portland, OR 97202-8199
Dr. Audrey Bilger, President Reed College 3203 SE Woodstock Boulevard Portland, OR 97202-8199
Mr. Maxwell Woods, Assistant Director for Nuclear Safety & Emergency Preparedness Oregon Department of Energy 550 Capitol Street N.E.
Salem, OR 97301
Program Director Radiation Protection Services Public Health Division Oregon Health Authority 800 NE Oregon Street, Suite 640 Portland, OR 97232-2162
Test, Research and Training Reactor Newsletter Attention: Ms. Amber Johnson Dept of Materials Science and Engineering University of Maryland 4418 Stadium Drive College Park, MD 20742-2115
NRC-002 OFFICE NRR/DANU/UNPO NRR/DANU: LA NRR/DANU/UNPO: BC NAME KRoche CSmith TTate DATE 06/06/2022 06/13/2022 06/15/2022
Enclosure
U.S. NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION
Docket No:
50-288
License No:
R-112
Report No:
Licensee:
Reed College
Facility:
Reed Research Reactor
Location:
Portland, OR
Dates:
April 25-27, 2022
Inspector:
Approved by:
Travis L. Tate, Chief Non-Power Production and Utilization Facility Oversight Branch Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation
- 2 -
EXECUTIVE SUMMARY
Reed College Reed Research Reactor Report No. 05000288/2022202
The primary focus of this routine, announced inspection was the onsite review of selected aspects of the Reed College (the licensees) Class II 250 kilowatt research reactor safety program including: (1) procedures, (2) health physics, (3) design changes, (4) committees, audits and reviews, and (5) transportation, since the last U.S. Nuclear Regulatory Commission (NRC) inspection of these areas. The licensees program was acceptably directed toward the protection of public health and safety and was generally in compliance with NRC requirements.
Procedures
- Facility procedures were acceptably reviewed, approved, and implemented as required by the Standard Operating Procedure.
Health Physics
- Surveys were accurately completed and documented to permit evaluation of the radiation hazards present as required by Technical Specifications (TSs) and the radiation protection program.
- Postings met the regulatory requirements specified in Title 10 of the Code of Federal Regulations (10 CFR) Parts 19, Notices, Instructions and Reports To Workers: Inspection and Investigations, and 20, Standards for Protection against Radiation.
- Personnel dosimetry was worn as required and doses were within the licensees procedural action levels and NRCs regulatory limits.
- Radiation monitoring equipment was maintained and calibrated as required by TSs.
- Acceptable radiation protection training was provided to the licensee personnel in accordance with the radiation protection program.
- The radiation protection program was implemented by the licensee and satisfied regulatory requirements.
- Effluent monitoring satisfied the licensee and regulatory requirements.
- Releases were within the specified regulatory and TS limits.
Design Change Functions
- The inspector found that changes to the facility were evaluated using the criteria specified in 10 CFR Section 50.59, Changes, tests and experiments, and were reviewed and approved by the Reactor Operations Committee (ROC) as required by TSs.
- 3 -
Committees, Audits and Reviews
- The review and the audit program was conducted by the Reactor Oversight Committee (ROC), as required by TSs.
- The ROC composition and meeting frequency satisfied the requirements specified in the TSs.
Transportation Activities
- The program for shipping radioactive material has satisfied regulatory requirements.
- 4 -
REPORT DETAILS
Summary of Facility Status
The Reed College (the licensees) Class II 250 kilowatt TRIGA Mark-I research reactor is operated in support of undergraduate instruction, laboratory experiments, reactor operator training, and various types of research. During the inspection, the reactor was operated for training.
1. Procedures
a. Inspection Scope (IP 69001)
The inspector reviewed the following to verify compliance with TS Section 6.4:
- selected Reed Research Reactor (RRR) facility procedures
procedural implementation and compliance
recent minor and substantive procedural changes
ROC and Radiation Safety Committee (RSC) meeting minutes for 2020 and 2021
Standard Operating Procedure (SOP) 61, Procedure Writing and Use, dated August 26, 2016
SOP 62, Changes, Tests, and Experiments, dated May 10, 2017
b. Observations and Findings
Administrative control of changes to procedures, and the associated review and approval process, were stipulated by RRR SOP 61. Substantive changes to procedures were required to be reviewed and approved by the ROC. The inspector verified that this process was being followed and that training of personnel on procedures and changes was acceptable.
c. Conclusion
The inspector determined that facility procedures were acceptably reviewed, approved, and implemented in accordance with the SOP.
2. Health Physics
a. Inspection Scope (IP 69001)
The inspector verified compliance with 10 CFR Parts 19 and 20, and TS Sections 3.5 and 4.5 and reviewed the following:
- radiological signs and posting
contamination reports and personnel contamination forms
personnel dosimetry records for 2021 and 2022 to date
daily reactor startup and shutdown checklists for 2021 and 2022 to date
external audits of the radiation safety program conducted for the ROC and RSC for the academic years 2020-2021
- 5 -
selected routine surveys and monitoring records for 2021 and 2022 to date including biweekly, bimonthly, and semiannual checklists
records of maintenance and calibration of radiation survey and monitoring instruments
the as low as reasonably achievable (ALARA) program, as described in the Radioactive Materials Policy and Procedures Manual
various RRR SOPs dealing with radiation monitors, health physics, and radiation work permits
Reed College Radioactive Materials Policy and Procedures Manual, dated June 2016
RRR annual reports for the last two reporting periods
airborne release calculation records
environmental counting and analysis records
various RRR SOPs dealing with environmental sampling and radioactive waste handling and disposal
ROC minutes for 2021 through present
selected routine surveys and monitoring records for 2021 and 2022 to date
b. Observations and Findings
The inspector toured the facility and observed maintenance activities. The inspector found practices regarding the use of dosimetry, radiation monitoring equipment, placement of radiological signs and postings, use of protective clothing, and the handling and storing of radioactive material or contaminated equipment was in accordance with regulations and the licensees written radiation protection program. The inspector also verified that the licensee performed and documented annual self-assessments of the program as a tool for assuring that radiation exposure was maintained ALARA.
The inspector found radiation surveys conducted were within the limits specified by the facility postings. The inspector did not observe any unmarked radioactive material in the facility. The inspector found the licensee posted a copy of the current NRC Form 3 notice to radiation workers required by 10 CFR Part 19, at the entrance to the control room and the reactor bay. The inspector determined that doses to facility occupants was minimal. The inspector found that radiation monitoring devices were calibrated within the frequencies specified in the procedures.
The inspector noted, from records, that training was provided for radiation workers assigned to the facility and individuals were not issued dosimetry or given access until the training was successfully completed. The annual reports referenced above, described the gaseous, liquid, and solid waste generated at the facility, with gaseous Argon-41 produced by the irradiation of atmospheric air was the most significant isotope noted. The inspector found the licensee also reported the results of air sampling and thermoluminescent dosimeters placed at locations around the facility as environmental radiation monitors. Surface water and vegetation were analyzed by the licensee for indications of environmental impacts and the inspector verified they showed no significant difference from background levels.
- 6 -
c. Conclusion
The inspector determined that the radiation protection program being implemented by the licensee satisfied regulatory requirements.
3. Design Changes
a. Inspection Scope (IP 69001)
The inspector reviewed the following to verify compliance with 10 CFR 50.59, regarding design change control:
- recent changes initiated by the licensee using the RRR 10 CFR 50.59 screen forms
minutes of the meetings held by the ROC and the RSC from 2021 to the present
RRR annual reports for the last two reporting periods
RRR biweekly checklists
RRR maintenance log
b. Observations and Findings
Observations
The inspector found the licensee completed several 10 CFR 50.59 screens since the last inspection. The licensee used 10 CFR 50.59 screen forms to determine whether a full evaluation of a change was needed. The inspector noted that no evaluations were required to be completed. The inspector determined that the facility design change screens contained adequate supporting documentation and information required by procedure.
c. Conclusion
The inspector determined that changes to the facility were evaluated using the 10 CFR 50.59 criteria and were reviewed and approved by the ROC, as required by TSs.
4. Committees, Audits and Reviews
a. Inspection Scope (IP 69001)
In order to verify that the licensee had an oversight committee that conducted reviews and audits as required in TS Section 6.4, the inspector reviewed the following:
Safety review and audit records for academic years 2020-2021
RRR Annual Reports for the last two reporting periods
- 7 -
b. Observations and Findings
The inspector confirmed that the ROC met as required by the TS and a quorum was present. The inspector confirmed that the safety reviews and audits conducted by the committee or designated individuals were completed at the TS-required frequency and topics of these reviews were also consistent with TS requirements and provided guidance, direction, and oversight of the reactor.
c. Conclusion
The inspector concluded that the ROC provided the oversight required by the TS.
5. Transportation of Radioactive Materials
a. Inspection Scope (IP 86740)
The inspector reviewed the following records to verify compliance with 10 CFR 71.5, Transportation of licensed materials. and procedural requirements for the transfer or shipment of licensed radioactive material:
- Records of radioactive material shipments completed from 2021 and to the present
SOP 54, Radioactive Materials Handling and Disposal, dated September 19, 2018
SOP 84, Shipping Radioactive Materials, dated March 22, 2019
RRR annual reports for the last two reporting periods
b. Observations and Findings
The inspector found that the licensee appropriately documented shipments of radioactive material made from 2018 to 2020.
c. Conclusion
The inspector determined that the program for shipping radioactive material satisfied regulatory requirements.
6. Exit Interview
The inspection scope and results were summarized on April 27, 2022, with members of the licensee management. The inspector described the areas inspected and discussed in detail the inspection findings. No proprietary material was reviewed by the inspector during the inspection.
- 8 -
PARTIAL LIST OF PERSONS CONTACTED
Licensee Personnel
T. Ellis Reactor Operations Manager Facility Director K. Oleson Dean of the Faculty, Reed College A. Sams Radiation Safety Officer and Campus Environmental Director
INSPECTION PROCEDURES USED
IP 69001:
Class II Non-Power Reactors IP 86740:
Inspection of Transportation Activities
ITEMS OPENED, CLOSED, AND DISCUSSED
Opened
None
Closed
None