IR 05000288/2014202
| ML14363A379 | |
| Person / Time | |
|---|---|
| Site: | Reed College |
| Issue date: | 01/06/2015 |
| From: | Kevin Hsueh Research and Test Reactors Licensing Branch |
| To: | Krahenbuhl M Reed College |
| Bassett, Craig 415-4495 | |
| References | |
| IR-2014202 | |
| Download: ML14363A379 (22) | |
Text
January 6, 2015
SUBJECT:
REED COLLEGE - NRC ROUTINE INSPECTION REPORT NO. 50-288/2014-202
Dear Dr. Krahenbuhl:
From December 8 to 11, 2014, the U.S. Nuclear Regulatory Commission (NRC or the Commission) completed an inspection at the TRIGA Mark-I Reed Research Reactor facility (Inspection Report No. 50-288/2014-202). The enclosed report documents the inspection results, which were discussed on December 11, 2014, with you, with Dr. Nigel Nicholson, Dean of the Faculty, and Kathleen Fisher, Radiation Safety Officer and Campus Environmental Director.
The inspection examined activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license.
The inspector reviewed selected procedures and records, observed various activities, and interviewed personnel. Based on the results of this inspection, no findings of significance were identified. No response to this letter is required.
In accordance with Title 10 of the Code of Federal Regulations Section 2.390, Public inspections, exemptions, and requests for withholding, a copy of this letter, its enclosure, and your response (if any) will be available electronically for public inspection in the NRC Public Document Room or from the NRCs document system (Agencywide Documents Access and Management System (ADAMS)). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). Should you have any questions concerning this inspection, please contact Mr. Craig Bassett at 301-466-4495 or by electronic mail at Craig.Bassett@nrc.gov.
Sincerely,
/RA/
Kevin Hsueh, Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation
Docket No. 50-288 License No. R-112
Enclosure:
NRC Inspection Report No. 50-288/2014-202
cc w/enclosure:
See next page
Reed College Docket No. 50-288
cc:
Mayor of City of Portland 1220 Southwest 5th Avenue Portland, OR 97204
Reed College ATTN: Dr. Patrick McDougal Dean of the Faculty 3203 S.E. Woodstock Boulevard Portland, OR 97202-8199
Reed College ATTN: Mr. John Kroger President 3203 S.E. Woodstock Boulevard Portland, OR 97202-8199
Oregon Department of Energy ATTN: David Stewart-Smith, Director Division of Radiation Control 625 Marion Street, N.E.
Salem, OR 97310
Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611