IR 05000275/1996020

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-275/96-20 & 50-323/96-20 on 960818- 0928 & Nov.Violation Involved Failure to Use Latest Rev of Chemistry Procedure When Obtaining Primary Sample
ML16343A452
Person / Time
Site: Diablo Canyon  
Issue date: 10/22/1996
From: Dyer J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Rueger G
PACIFIC GAS & ELECTRIC CO.
Shared Package
ML16342D465 List:
References
NUDOCS 9610290188
Download: ML16343A452 (8)


Text

~

~

,~

~p,R REGS~

c<

Mp0 Cy 0O

~/+

'

/f +>>*++

UNITEDSTATES NUCLEAR REGULATORY COMMI$$ION

REGION IV

611 RYAN PLAZA DRIVE, SUITE 400

SUBJECT:

NRC INSPECTION REPORT 50-275/96-20; 50-323/96-20 AND NOTICE OF

. VIOLATION

Dear Mr. Rueger:

An NRC inspection was conducted August 18 through September 28, 1996, at your Diablo Canyon Nuclear Power Plant, Units 1 and 2, reactor facilities. The enclosed report presents the scope and results of that inspection.

During the inspection period, your conduct of activities at the Diablo Canyon facility was generally characterized by safety conscious operations and good maintenance and engineering practices; however, one violation was identified.

The violation involved the failure to use the latest revision of a chemistry procedure when obtaining a primary sample.

This violation would normally be considered as minor but similar problems were identified by inspectors in NRC Inspection Report 50-275/96-06, and the actions initiated to prevent recurrence were ineffective.

The violation is cited in the enclosed Notice of Violation (Notice), and the circumstances surrounding the violation are desoribed in detail in the enclosed report.

Please note that you are required to respond to this letter and should follow the instructions specified in the enclos'ed Notice when preparing your response.

The NRC will use your response, in part, to determine whether further enforcement action is necessary to ensure compliance with regulatory requirements.

In accordance with 10 CFR 2.790 of the NRC's "Rules of Practice," a copy of this letter, its enclosure, and your response will be placed in the NRC Public Document Room (PDR).

To the extent possible, your response should not include any personal privacy, proprietary, or safeguards information so that it can be placed in the PDR without redaction.

96i0290188 96i022 PDR ADQCK 05000275

PDR

~

/

Should you have any questions concerning this inspection, we will be pleased to discuss them with you.

Sincerely, J. E. Dyer, Director Division of Reactor Projects Docket Nos.:

50-275 50-323 License Nos.:, DPR-80 DPR-82 Enclosure:

NRC Inspection Report 50-275/96-20; 50-323/96-20 cc w/enclosure:

Dr. Richard Ferguson Energy Chair Sierra Club California 1100 lith Street, Suite 311 Sacramento, California 95814 Ms. Nancy Culver San Luis Obispo Mothers for Peace P.O. Box 164 Pismo Beach, California 93448 Chairman San Luis Obispo County Board of Supervisors Room 370 County Government Center San Luis Obispo, California 93408 Mr. Truman Burns)Mr. Robert Kinosian California Public Utilities Commission 505 Van Ness, Rm. 4102 San Francisco, California 94102

C

Pacific Gas and Electric Company

-

-3-Robert R. Wellington, Esq.

Legal Counsel Diablo Canyon Independent Safety Committee 857 Cass Street, Suite D Monterey, California 93940 Mr. Steve Hsu Radiologic Health Branch State Department of Health Services P.O. Box 942732 Sacramento, California 94234 Christopher J. Warner, Esq.

Pacific Gas and Electric Company P.O. Box 7442 San Francisco, California 94120 Robert P. Powers, Vice President and Plant Manager Diablo Canyon Power Plant P.O. Box 56 Avila Beach, California 93424

Pacific Gas and Electric Company-4-E-Mail report to D. Nelson (DJN)

E-Mail report to NRR Event Tracking System (IPAS)

bcc to DMB (IE01)

bcc distrib. by RIV:

L. J. Callan DRP Director Branch Chief (DRP/E, WCFO)

Senior Project Inspector (DRP/E, WCFO)

Branch Chief (DRP/TSS)

Leah Tremper (OC/LFDCB, MS: TWFN 9E10)

Resident Inspector DRS-PSB MIS System RIV File M. Hammond (PAO, WCFO)

2Eog DOCUMENT NAME: R:3 DCiDC620RP.MDT To receive copy of document, indicate in box: "C" = Copy without enclosures

"E" = Copy with enclosures "N"

~ No copy RIV:Rl:DRP/E MDTschiltz 10/1 1/96 C:DRP/E FRHuey 10/1 1/96 D:DRP JEDyer RIV:WCFO KEPerkin 10@M6

96 OFFICIAL RECORD COPY

~

~