Text

UNITED STATES NUCLEAR REGULATORY COMMISSION Docket Nos. 50-272, 50-311 License Nos. DPR-70, DPR-75 Mr. Steven Miltenberger WASHINGTON. D.C. 20555-0001 August 4, 1994 Vice President and Chief Nuclear Officer Public Service Electric and Gas Company P.O. Box 236 Hancocks Bridge, NJ 08038

Dear Mr. Miltenberger:

Subject: NRC PRELIMINARY PERFORMANCE ASSESSMENT RESULTS - SALEM During the period from July 11 through July 29, 1994 a special team under the direction of the Special Inspection Branch of the Office of Nuclear Reactor Regulation completed the first phase of a comprehensive assessment of performance at the Salem Nuclear Generating Station. This assessment is being conducted under a pilot NRC program designed to develop a customized inspection plan based on an objective, integrated review of performance insights confirmed through an on-site assessment.

The pilot process consists of an in-office review of NRC inspection reports, licensee event reports, performance indicators, self assessments, and other documentation followed by the integration of this information and the development of performance insights. A two week on-site assessment will be conducted beginning on August 15, 1994 to validate the team's preliminary assessment results. A final assessment report will then be issued to recommend future inspection activities for the upcoming SALP period.

The results of the preliminary assessment are enclosed with this letter.

The results have been compiled and assembled on a Performance Assessment/

Inspection Planning Tree along with brief summaries of the team's findings regarding each of the tree elements.

The Performance Assessment/Inspection Planning Tree is divided into five individual performance areas: licensee control systems, operations, engineering, maintenance, and plant support.

These performance areas are sub-divided into individual elements.

Each individual element has been assigned a rating based upon the assessment results.

Elements where reduced, normal, and increased NRC inspection appear to be warranted have been assigned green, yellow, and red ratings respectively on the enclosed planning tree.

Elements where insufficient information existed to come to a meaningful conclusion have been assigned a temporary blue rating. Overall performance areas will receive a rating once the on-site portion of the assessment is completed.

The individual ratings provided in this preliminary assessment are based upon the in-office documentation review described above and may change once the team completes its on-site assessment.

Au. 4, 1994 Mr. Steven Miltenberger-2-This preliminary information is being provided for your information only.

No response to this letter or to the preliminary assessment is required or expected.

Should you have any questions concerning this preliminary assessment, or regarding the assessment process in general, please contact Mr. Robert Gallo at (301) 504-2967 or Mr. Jeffrey Jacobson at (301) 504-2977.

Enclosure: As stated cc:

See page 3 DISTRIBUTION:

Sincerely, Original Signed By Steven A. Varga, Director Division of Reactor Projects I/II Office of Nuclear Reactor Regulation DRIL R/F Central Files JBJacobson WTRussell RWCooper ECWenzinger RLSpessard RMGallo ATGody RSIB R/F C!Jo~K~l-~[iles-~5o:;-tz2}'3TP CLMi ller FJMiraglia SAVarga MRJohnson ACThadani RPZimmerman WMDean PDR OCA

  • Previously concurred OFFICE:

AC:RSIB/DRIL c

NAME:

JBJacobson*

DATE:

08/02/94 08/ ::> /94 OFFICIAL RECORD COPY DOCUMENT NAME:

Public Service Electric & Gas Company cc:

Mark J. Wetterhahn, Esquire Winston & Strawn 1400 L Street NW Washington, DC 20005-3502 Richard Fryling, Jr., Esquire Law Department - Tower SE 80 Park Place Newark, NJ 07101 Mr. J. Hagan, Acting General Manager - Salem Operations Salem Generating Station P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. J. Hagan Vice President - Nuclear Operations Nuclear Department P.O. Box 236 Hancocks Bridge, New Jersey 08038 Mr. Charles S. Marschall, Senior Resident Inspector Salem Generating Station U.S. Nuclear Regulatory Commission Drawer I Hancocks Bridge, NJ 08038 Dr. Jill Lipoti, Asst. Director Radiation Protection Programs NJ Department of.Environmental Protection and Energy CN 415 Trenton, NJ 08625-0415 Maryland People's Counsel American Building, 9th Floor 231 East Baltimore Street Baltimore, Maryland 21202 Mr. J. T. Robb, Director Joint Owners Affairs Philadelphia Electric Company 955 Chesterbrook Blvd., SlA-13 Wayne, PA 19087-3-Salem Nuclear Generating Station, Units 1 and 2 Richard Hartung Electric Service Evaluation Board of Regulatory Commissioners 2 Gateway Center, Tenth Floor Newark, NJ 07102 Regional Administrator, Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Lower Alloways Creek Township c/o Mary 0. Henderson, Clerk Municipal Building, P.O. Box 157 Hancocks Bridge, NJ 08038 Mr. Frank X. Thomson, Jr., Manager Licensing and Regulation Nuclear Department P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. David Wersan Assistant Consumer Advocate Office of Consumer Advocate 1425 Strawberry Square Harrisburg, PA 17120 Ms. P. J. Curham MGR. Joint Generation Department Atlantic Electric Company P.O. Box 1500 6801 Black Horse Pike Pleasantville, NJ 08232 Carl D. Schaefer External Operations - Nuclear Delmarva Power & Light Company P.O. Box 231 Wilmington, DE 19899 Public Service Commission of Maryland Engineering Division Chief Engineer 6 St. Paul Centre Baltimore, MD 21202-6806

cc:

(con't)

Mr. S. LaBruna Vice President - Nuclear Engineering Nuclear Department P.O. Box 236 Hancocks Bridge, New Jersey 08038 Mr. Dennis J. Zannoni, Supervisor Bureau of Nuclear Engineering Radiation Protection Programs NJ Department of Environmental Protection and Energy CN 415 Trenton, NJ 08625-0415 Mr. Steven