Text

___-_

'I

  • <

'k# "'IOk UNITED STATES

,8 j,

NUCLEAR REGULATORY COMMISSION

,

.t'

o REGION 11

$

230 PEACHTREE STREET, N.W.sulTE B18

'

e

f o

ATLANTA, GEORGI A 30303

-

!

'%,.....

.

Report Nos.:

50-269/78-12, 50-270/78-11 and 50-287/78-11 Docket Nos.: 50-269, 50-270 and 50-287 License Nos.:

DPR-38, DPR-47 and DPR-55 Licensee:

Duke Power Company P. O. Box 2178 422 South Church Street Charlotte, North Carolina 28242 Facility Name:

Oconee Units 1, 2 and 3

Inspection at:

Seneca, South Carolina Inspection conducted:

May 9-12, 1978 i

,

Inspectors:

J. E. Ouzts D. R. McGuire C. L. Davis l

Accompanying Perso

P. J p 11ogg Approved by:

.!/

6. 4 P.

s we '

g, chief ~

/Dat'e Nuclear upport Se(tion No. 2 Reactor Operations and Nuclear Support Branch Inspection Summary Inspection on May 9-12, 1978 (Report Nos. (50-269/78-12, 50-270/78-11 and 50-287/78-11)

Areas Inspected:

Routine, unannounced inspection of instrument cali-bration, chemistry laboratory, control room operations, surveillance test program and followup of Immediate Action Letter sent to Licensee by RII on March 17, 1978, for Units 1, 2 and 3.

The inspection involved 53 inspector-hours onsite by four NRC inspectors.

Results:

Within the five areas inspected, no items of noncompliance were identified in four areas; one apparent item of noncompliance i

(infraction - failure to provide direct surveillance of a high radiation area) was identified in one area.

...