IR 05000255/2001016

From kanterella
Jump to navigation Jump to search
IR 05000255/2001-016, Palisades Nuclear Generating Plant, Inspection on 11/20/2001 - 12/29/2001 Related to Adverse Weather Protection and Heat Sink Performance. Three Issues of Very Low Safety Significance Identified
ML020110187
Person / Time
Site: Palisades 
Issue date: 01/11/2002
From: Anton Vegel
Division Reactor Projects III
To: Cooper D
Nuclear Management Co
References
IR-01-016
Download: ML020110187 (35)


Text

January 11, 2002

SUBJECT:

PALISADES NUCLEAR GENERATING PLANT NRC INSPECTION REPORT 50-255/01-16(DRP)

Dear Mr. Cooper:

On December 29, 2001 the NRC completed an inspection at your Palisades Nuclear Generating Plant. The enclosed report documents the inspection findings which were discussed on January 3, 2002, with members of your staff.

The inspection examined activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license.

The inspector reviewed selected procedures and records, observed activities, and interviewed personnel.

Based on the results of this inspection, the inspectors identified three issues of very low safety significance (Green) that were determined to involve violations of NRC requirements. However, because of the very low safety significance and because the issues were entered into your corrective action program, the NRC is treating these issues as Non-Cited Violations in accordance with Section VI.A.1 of the NRC s Enforcement Policy. If you deny these Non-Cited Violations, you should provide a response with a basis for your denial, within 30 days of the date of this inspection report, to the Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington, DC 20555-0001, with copies to the Regional Administrator, Region III; the Director, Office of Enforcement, United States Nuclear Regulatory Commission, Washington, DC 20555-0001; and the NRC Resident Inspector Office at the Palisades facility. In accordance with 10 CFR 2.790 of the NRC's "Rules of Practice," a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/NRC/ADAMS/index.html (the Public Electronic Reading Room).

Sincerely,

/RA/

Anton Vegel, Chief Branch 6 Division of Reactor Projects Docket No. 50-255 License No. DPR-20

Enclosure:

Inspection Report 50-255/01-16(DRP)

REGION III==

Docket No:

50-255 License No:

DPR-20 Report No:

50-255/01-16(DRP)

Licensee:

Nuclear Management Company, LLC Facility:

Palisades Nuclear Generating Plant Location:

27780 Blue Star Memorial Highway Covert, MI 49043-9530 Dates:

November 20 through December 29, 2001 Inspectors:

J. Lennartz, Senior Resident Inspector R. Krsek, Resident Inspector D. Nelson, Radiation Specialist, RIII J. Gavula, Reactor Inspector, RIII K. Coyne, Resident Inspector, D.C. Cook J. Maynen, Resident Inspector, D.C. Cook T. Madeda, Physical Security Inspector Approved by:

Anton Vegel, Chief Branch 6 Division of Reactor Projects

SUMMARY OF FINDINGS IR 05000255/01-16 on 11/20 - 12/29/2001, Nuclear Management Company, LLC, Palisades Nuclear Generating Plant. Adverse weather protection and heat sink performance.

This report covers a 6-week routine inspection, a baseline physical security inspection, a baseline occupational radiation safety inspection, and a baseline biennial heat sink inspection.

The inspections were conducted by resident and specialist inspectors.

A.

Inspector Identified Findings Cornerstone: Mitigating Systems

Green. A Non-Cited Violation of 10 CFR Part 50, Appendix B, Criterion XVI, Corrective Action, was identified for the failure to promptly identify and correct conditions adverse to quality associated with the cold weather protection of the Condensate Storage Tank level instrumentation. The deficiencies associated with the insulation of the level instruments was identified during the previous cold weather inspection conducted by the inspectors in December 2000 and the condition adverse to quality was not corrected.

The finding was considered to be more then minor because this condition was initially identified in December 2000, and the licensee failed to promptly identify and correct the condition adverse to quality. In addition, the failure of the Condensate Storage Tank level instrumentation could have a credible impact on safety. The issue was determined to be of very low significance (Green) by the significance determination process because there was no actual failure of safety-related components associated with the mitigating systems cornerstone.

(Section 1R01).

Cornerstone: Initiating Events

Green. A Non-Cited Violation of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, was identified for failure to follow a preventative maintenance procedure step to inspect the head sprockets and sprocket tooth-inserts on the traveling screens for wear. Failure to follow this step contributed to the failure of the F-4B traveling screen.

The issue was determined to be of very low significance (Green) by the significance determination process because, although the issue is a transient initiator contributor, the issue does not contribute to the likelihood of a primary or secondary system loss of coolant accident initiator, or the increase in likelihood of a fire or flood. (Section 1R07)

Green. A Non-Cited Violation of 10 CFR Part 50, Appendix B, Criterion XVI, Corrective Action, was identified for the failure to promptly identify and correct deficiencies (wear) observed on the F-4B traveling screen boot-plate. Failure to

promptly identify and correct these deficiencies contributed to the failure of the F-4B traveling screen.

The issue was determined to be of very low significance (Green) by the significance determination process because, although the issue is a transient initiator contributor, the issue does not contribute to the likelihood of a primary or secondary system loss of coolant accident initiator, or the increase in likelihood of a fire or flood. (Section 1R07)

Report Details A list of documents reviewed within each inspection area is included at the end of the report.

Summary of Plant Status The plant remained in Cold Shutdown (Mode 5) for a corrective maintenance outage during the entire inspection period. The plant entered Mode 5 on June 21, 2001, because of a small leak from an axial crack on the Control Rod Drive Mechanism 21 pressure housing. The licensee completed root cause evaluations and replaced all 45 control rod drive mechanism pressure housings to correct the problem. Additional scheduled preventative and other required corrective maintenance activities were in progress when the inspection period ended.

1.

REACTOR SAFETY Cornerstones: Initiating Events, Mitigating Systems, Barrier Integrity and Emergency Preparedness 1R01 Adverse Weather Protection (71111.01)

a.

Inspection Scope The inspectors reviewed the implementation of the licensees program for the onset of cold weather conditions. The inspectors walked down portions of the service water, auxiliary feedwater and emergency core cooling systems which were susceptible to the effects of cold weather conditions, and verified that the appropriate protection features were in place and operable for these systems. The inspectors also verified that the implementation of the licensees cold weather protection procedures ensured that components were initially protected from cold weather effects and periodically monitored during the entire cold weather season.

The inspection incorporated discussions with the system engineers and operations personnel, and reviews of the applicable portions of Updated Final Safety Analysis Report.

b.

Findings The inspectors identified a Green finding that is being treated as a Non-Cited Violation of 10 CFR Part 50, Appendix B, Criterion XVI, Corrective Action, for the failure to promptly identify and correct a condition adverse to quality associated with cold weather protection of the Condensate Storage Tank level instrumentation.

In December 2000, the inspectors identified to licensee staff that the insulation for the Condensate Storage Tank level instrumentation was in a degraded condition and may not be adequately protected for cold weather. Licensee staff initiated work requests to correct this condition adverse to quality. The level instrumentation provided a safety function to plant operators for routine Technical Specification surveillances and for the performance of operator actions during certain Emergency Operating Procedures, to

ensure an adequate volume of water was available for the auxiliary feedwater system during normal and accident conditions.

While performing a walkdown of the Condensate Storage Tank level instrumentation in November 2001, the inspectors again identified to licensee staff that the same degraded condition existed for the level instrumentation insulation. Licensee staff determined that while work requests had been written in December 2000 for this condition adverse to quality, the work requests had been canceled without repairing the degraded insulation for the level instrumentation. Licensee Staff initiated a new work request and the degraded insulation was repaired in December 2001.

The failure to promptly identify and correct deficiencies regarding cold weather protection of the Condensate Storage Tank level instrumentation was more than minor, in that, the issue could have a credible impact on safety. Specifically, the degraded insulation could increase the probability that the level transmitters would freeze during the upcoming cold weather season. Consequently, an inaccurate level indication for the safety related condensate storage tank could be used during plant operation including the conduct of Technical Specification surveillances. In addition, the level indications would be used by operators during the performance actions prescribed by certain Emergency Operating Procedures to verify adequate water supply to the auxiliary feedwater system.

The issue was determined to be of very low significance (Green) by the Phase 1 Screening Worksheet for the Mitigating Systems Cornerstone in the significance determination process because no actual loss of a safety function occurred.

10 CFR Part 50, Appendix B, Criterion XVI, Corrective Action, requires, in part, that measures be established to assure that conditions adverse to quality are promptly identified and corrected. Contrary to this, the licensee failed to promptly identify and correct deficiencies associated with the degraded insulation on the condensate storage tank level instrumentation when the issue was initially raised by the inspectors in December 2000. This violation is associated with a NRC identified inspection finding that is characterized by the significance determination process as having very low risk significance (Green) and is being treated as a Non-Cited Violation of 10 CFR Part 50, Appendix B, Criterion XVI, consistent with Section VI.A.1 of the NRC Enforcement Policy (NCV 50-255/01-16-01). This finding is in the licensees corrective action program as Condition Report CPAL0103934.

1R04 Equipment Alignment (71111.04)

.1 Quarterly Equipment Alignment Walkdowns a.

Inspection Scope The inspectors performed partial walkdowns of 125 volt vital DC power and the service water system utilizing plant procedure system checklists to verify proper system lineup while the redundant plant equipment was out of service. The inspectors verified that power was available, that accessible equipment and components were appropriately aligned, and that no discrepancies existed which would impact the safety function of the systems.

The inspectors also reviewed selected condition reports that had been entered into the licensees corrective action program to verify that the corrective actions were reasonable and had been implemented as scheduled.

b.

Findings No findings of significance were identified.

.2 Semiannual Equipment Alignment Walkdown a.

Inspection Scope The inspectors walked down the safety related mitigating plant equipment that was in service to minimize shutdown plant risk. The inspectors utilized the shutdown cooling equipment availability sheets and shutdown operation protected train equipment checklists to verify that the appropriate equipment was in service, and that accessible equipment components were correctly aligned. The inspectors also reviewed active maintenance work requests, active design and engineering issues, including known operator workarounds and temporary modifications, to verify that the safety function of the equipment was not impacted.

b.

Findings No findings of significance were identified.

1R06 Flood Protection a.

Inspection Scope The inspectors reviewed and assessed flood protection measures for internal and external flooding events. The inspectors performed walkdowns of the following risk significant flood areas in the plant:



Auxiliary Feedwater;



Station Batteries;



Charging Pumps;



Containment Spray Pumps;



Emergency Diesel Generators;



480 V Load Centers;



Component Cooling Water Pumps;



480 V Motor Control Centers;



Safety Injection Pumps;



Service Water Pumps; and



2400 V Switchgear.

In addition, the inspectors reviewed applicable sections of the Updated Final Safety Analysis Report, design basis documentation, relevant plant and maintenance procedures, and completed work requests. Further, the inspectors reviewed condition

reports to verify that identified problems associated with flood protection activities were appropriately characterized and entered into the licensees corrective action program.

b.

Findings No findings of significance were identified.

1R07 Heat Sink Performance (71111.07)

a.

Inspection Scope Regional specialist inspectors reviewed documents associated with maintenance, inspection and thermal performance testing of the component cooling water heat exchangers, and the emergency diesel generator jacket water and lube oil coolers.

These heat exchangers and coolers were chosen based on having high risk achievement worths in the station's probabilistic safety assessment. While on site, the inspectors reviewed completed surveillances, associated calculations, instrument calibration records, and maintenance work orders and performed independent calculations to verify that these activities adequately ensured proper heat transfer. The inspector reviewed the documentation to confirm that the test methodology was consistent with accepted industry practices, that test acceptance criteria were consistent with design basis values, and that the test results appropriately considered differences between test and design conditions. The inspector also reviewed documentation to confirm that methods used to inspect the heat exchangers were consistent with expected degradation and that the established acceptance criteria were consistent with accepted industry standards. In addition, the inspectors reviewed condition reports concerning heat exchanger or heat sink performance issues to verify that the licensee had an appropriate threshold for identifying issues and to evaluate the effectiveness of the corrective actions to the identified issues.

b.

Findings The inspectors identified two Green findings that are being treated as Non-Cited Violations of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, for the failure to follow a preventative maintenance procedure, and of 10 CFR Part 50, Appendix B, Criterion XVI, Corrective Action, for the failure to promptly identify and correct a condition adverse to quality.

As part of a licensee initiative, in September 2000, it was identified that a preventative maintenance procedure to perform vendor-recommended inspections on the traveling screens had been canceled in 1990. The corrective actions for this problem included re-initiation of PPAC SWS026, Traveling Screen Preventive Maintenance, which was completed under Work Order 24014799, on April 20, 2001. However, on December 3, 2001, traveling screen F-4B failed when a broken sprocket tooth-insert jammed between the basket carrying chain and the head sprocket.

Step 2 of the preventative maintenance procedure specified that the head sprockets and sprocket tooth-inserts be inspected for wear. After the traveling screen failed, the licensees service water system engineer inspected the components and noted that the

head sprocket had broken through one of the sprocket tooth-insert bolt holes, which allowed the insert to be mispositioned. The condition of the break surface and remaining bolt indicated that this failure occurred several years ago. The NRC inspectors also observed the damaged components and agreed with the system engineers determination. Based on this, the preventative maintenance activities were not accomplished in accordance with the PPAC SWS026 because existing damage had not been identified.

This failure to accomplish activities affecting quality in accordance with documented instructions was more than minor, because the inspectors considered it a contributing factor in the failure of the F-4B traveling screen. This issue could be reasonably viewed as a precursor to a significant event and, if left uncorrected, the same issue under the same conditions could become a more significant safety concern. The inspectors also determined that the failure of the traveling screens could cause or increase the frequency of a loss of service water initiating event.

The issue was determined to be of very low significance (Green) by the significance determination process because, although the issue is a transient initiator contributor, the issue does not contribute to the likelihood of a primary or secondary system loss of coolant accident initiator, or the increase in likelihood of a fire or flood.

10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, requires, in part, that activities affecting quality be accomplished in accordance with the documented instructions. Contrary to this, the licensees inspection of the F-4B traveling screen sprockets and sprocket inserts completed on April 20, 2001, did not identify damaged components indicative of wear as specified in PPAC SWS026, Step 2. This violation is associated with a NRC identified inspection finding that is characterized by the significance determination process as having very low risk significance (Green) and is being treated as a Non-Cited Violation of 10 CFR Part 50, Appendix B, Criterion V, consistent with Section VI.A.1 of the NRC Enforcement Policy (NCV 50-255/01-16-02).

This finding is in the licensees corrective action program as Condition Report CPAL0103970.

Step No. 3 of this preventative maintenance procedure specified the inspection of the traveling screens boot plate for wear. The work order summary noted that wear was observed on the boot plate, and that the long term actions would include its repair or replacement. However, no additional corrective actions were taken to correct the problem and a condition report was not initiated to document this condition adverse to quality.

The failure to promptly identify and correct deficiencies (boot plate wear) on the traveling screens was more than minor in that the inspectors considered it a contributing factor in the failure of the F-4B traveling screen. This issue could be reasonably viewed as a precursor to a significant event and if left uncorrected, the same issue under the same conditions could become a more significant safety concern. The inspectors also determined that the failure of the traveling screens could cause or increase the frequency of a loss of service water initiating event.

The issue was determined to be of very low significance (Green) by the significance determination process because, although the issue is a transient initiator contributor, the issue does not contribute to the likelihood of a primary or secondary system loss of coolant accident initiator, or the increase in likelihood of a fire or flood.

10 CFR Part 50, Appendix B, Criterion XVI, Corrective Action, requires, in part, that measures be established to assure that conditions adverse to quality are promptly identified and corrected. Contrary to this, the licensee failed to promptly identify and correct deficiencies (wear) observed on the F-4B traveling screen boot-plate during maintenance activities performed on April 20, 2001. This violation is associated with a NRC identified inspection finding that is characterized by the significance determination process as having very low risk significance (Green) and is being treated as a Non-Cited Violation of 10 CFR Part 50, Appendix B, Criterion XVI, consistent with Section VI.A.1 of the NRC Enforcement Policy (NCV 50-255/01-16-03). This finding is in the licensees corrective action program as Condition Report CPAL0103865.

1R11 Licensed Operator Requalification Program (71111.11Q)

a.

Inspection Scope The inspectors observed plant simulator training sessions to assess the effectiveness of the licensed operators training. The first training session reviewed recent changes to the Off Normal Procedures for the loss of preferred Alternating Current Buses Y10, Y20, Y30 and Y40. The inspectors verified that the objectives identified in the simulator exercise guides were satisfied during the training session.

The inspectors also observed licensed operator training in the plant simulator that was conducted to familiarize the operators with a plant modification that was completed on the emergency core cooling recirculation actuation system. The training session required the operators to implement revised emergency operating procedures and off normal operating procedures, and to operate new control panel switches that were installed during the modification. The inspectors verified that the training sessions were effective, and assessed the operators ability to implement the revised procedures and ability to operate the new control panel switches in a timely manner to mitigate various simulated accident scenarios.

b.

Findings No findings of significance were identified.

1R12 Maintenance Rule Implementation (71111.12Q)

a.

Inspection Scope The inspectors reviewed the licensees Maintenance Rule Scoping Document for the following plant equipment designated as having high safety significance:



Emergency Diesel Generator 1-2;



Shutdown Cooling;



125 Volt Vital DC Power; and



Service Water Traveling Screens The inspectors reviewed the licensees maintenance rule performance indicators associated with the systems maintenance rule category a(2) status. In addition, the inspectors discussed various technical issues with the applicable system engineer.

Further, the inspectors reviewed selected condition reports to verify that the identified issues were appropriately characterized and were dispositioned in accordance with the licensees Maintenance Rule program. The inspectors reviewed selected condition reports to verify that designated corrective actions were reasonable and had been implemented as scheduled.

b.

Findings No findings of significance were identified.

1R13 Maintenance Risk Assessments and Emergent Work Evaluation (71111.13Q)

a.

Inspection Scope The inspectors reviewed shutdown safety risk assessments, Shift Supervisor logs and maintenance activity schedules to verify that the plant equipment necessary to minimize shutdown plant risk was operable and/or available as required. The inspectors randomly conducted plant tours to verify that the appropriate equipment was available for use during planned and emergent maintenance which included the following activities:



scheduled testing of safety-related 125 volt battery ED-02 during a scheduled outage on the switchyard 345 KV rear bus;



scheduled motor replacement for Service Water Pump P-7C concurrent with emergent corrective maintenance to the service water traveling screens;



scheduled modifications to safety-related containment sump check valves concurrent with a scheduled outage on the switchyard 345 KV rear bus and emergent corrective maintenance to the service water traveling screens; and



scheduled surveillance testing of Emergency Diesel Generator 1-2, concurrent with scheduled modifications to emergency core cooling recirculation actuation circuitry and emergent corrective maintenance to the service water traveling screens.

The inspectors discussed the shutdown operation equipment checklists and plant configuration control for the maintenance activities with operations, maintenance and work control center personnel to verify that necessary steps were taken to control the work activities.

In addition, the inspectors reviewed select condition reports to verify that identified problems regarding maintenance risk assessments and control of emergent work

activities were appropriately characterized and entered into the licensees corrective action program.

b.

Findings No findings of significance were identified.

1R16 Operator Workarounds (71111.16)

a.

Inspection Scope The inspectors reviewed the operator workarounds to identify any potential effect on the functionality of mitigating systems. The inspectors assessed the accumulative effect of identified operator workarounds on the following:



the reliability, availability and potential for misoperation of a system;



the ability of the operators to respond in a correct and timely manner to plant transients and accidents;



the potential to increase an initiating event frequency; and



the potential to effect multiple mitigating systems.

The inspectors also verified that plant equipment was accessible, adequate procedural guidance existed and that tools needed to complete a task were readily available for the operator workarounds that would be required during implementation of the emergency operating procedures.

b.

Findings No findings of significance were identified.

1R17 Permanent Plant Modifications (71111.17)

a.

Inspection Scope The inspectors reviewed the following risk significant permanent plant modification:

Mitigating Systems Cornerstone



Engineering Action Request EAR 2001-0021, Modify packing in CK-ES3166 &

CK-3181 with lower friction design The inspectors reviewed the permanent plant modification, associated 10 CFR 50.59 screening, and associated work orders to verify consistency with the system design bases as described in the Updated Final Safety Analysis Report and the Technical Specifications. The inspectors verified that plant changes did not result in an adverse impact on equipment availability, reliability, or functional capability. The inspectors verified that component procurement documentation and installation instructions were consistent with the modification description. Additionally, the inspectors reviewed post

modification testing requirements to ensure that testing was consistent with equipment functional requirements.

b.

Findings

No findings of significance were identified.

1R19 Post Maintenance Testing (71111.19Q)

a.

Inspection Scope The inspectors observed portions of post maintenance testing and reviewed documented testing activities following scheduled maintenance to determine whether the tests were performed as written. The inspectors also verified that applicable testing prerequisites were met prior to the start of the tests and that the effect of testing on plant conditions was adequately addressed by control room personnel. Post maintenance test activities were reviewed for the following:



Containment Sump Outlet Check Valve CK-ES3166; and



Recirculation Actuation Signal.

The inspectors reviewed post maintenance testing criteria specified in the applicable preventive and corrective work orders to verify that the test criteria was appropriate with respect to the scope of work performed and that the acceptance criteria were clear.

In addition, the inspectors reviewed the completed tests and procedures to verify that the tests adequately verified system operability. Documented test data was reviewed to verify that the data was complete, and that the equipment met the procedure acceptance criteria which demonstrated that the equipment was able to perform the intended safety functions.

Further, the inspectors reviewed condition reports regarding post maintenance testing activities to verify that identified problems were appropriately characterized.

b.

Findings No findings of significance were identified.

1R23 Temporary Plant Modifications a.

Inspection Scope The inspectors reviewed the temporary modification package and associated 10 CFR 50.59 evaluation for the following temporary modification:

TM 2001-014, "Due to damaged detectors, change locations of cabling at the reactor head for the incore detectors to provide the required 16 totally qualified detector installations. Also make corresponding changes to the addresses to provide proper signals to the PPC.

The licensee installed this temporary modification to relocate environmentally qualified cables to undamaged connections on the reactor vessel head.

In addition, the inspectors reviewed condition reports concerning this temporary modification to verify that identified problems were appropriately characterized and evaluated.

b.

Findings No findings of significance were identified.

2.

RADIATION SAFETY Cornerstone: Occupational Radiation Safety 2OS3 Radiation Monitoring Instrumentation (71121.03)

.1 Identification of Radiological Monitors Associated With High/Very High Radiation Areas a.

Inspection Scope The inspector completed walkdowns and reviewed calibration records to verify the accuracy and operability of radiation monitoring instruments used for the protection of occupational workers. Instrumentation included area radiation monitors (ARMs),

continuous air monitors (CAMs), portable survey meters, the whole body counter, portal monitors, and electronic dosimeters.

The Final Safety Analysis Report (FSAR) was reviewed to identify those ARMs and CAMs that were associated with transient high and very high radiation areas. These monitors included, but were not limited to, the following:



Fuel Pool Area Monitor



High Range Containment Monitor



Containment Atmosphere Gas Monitor The inspector performed a walkdown of selected ARMs and CAMs in order to verify that locations were as described in the FSAR.

b.

Findings No findings of significance were identified.

.2 Calibration and Operability of Radiological Instrumentation a.

Inspection Scope The inspector reviewed the most recent calibrations and alarm set points for selected ARMs and CAMs. A representative sample of current calibration records were reviewed

for the whole body counter, personnel contamination monitors, portable radiation survey instruments, electronic dosimeters, and whole body frisking monitors. The inspector observed the calibration process for portable survey instruments and electronic dosimeters, reviewed instrument logs, and observed source checks in order to verify compliance with procedures.

b.

Findings No findings of significance were identified.

.3 Respiratory Protection - Self-Contained Breathing Apparatus a.

Inspection Scope The inspector reviewed the status and surveillance records for self-contained breathing apparatus that was located in various areas onsite, including those units reserved for fire brigade and control room personnel. In addition, the inspector reviewed the licensees training, mask fit, and medical qualification records to verify that applicable emergency response and control room personnel were currently trained and qualified in the use of self-contained breathing apparatus.

b.

Findings No findings of significance were identified.

.4 Problem Identification and Resolution a.

Inspection Scope

The inspector reviewed a self-assessment of the radiation monitoring instrumentation program and the licensees year 2001 condition reports covering radiological incidents involving personnel internal contamination events and radiological instrumentation, to verify that the licensee could identify, track, and correct radiological problems in these areas.

b.

Findings No findings of significance were identified.

3.

SAFEGUARDS Cornerstone: Physical Protection 3PP4 Security Plan Changes (71130.04)

a.

Inspection Scope The inspector reviewed Revision 9 to the Palisades Nuclear Plant Safeguards Contingency Plan to verify that the changes did not decrease the effectiveness of the submitted document. The referenced revision was submitted in accordance with 10 CFR 50.54(p)(2) requirements by licensee letter dated August 30, 2001.

b.

Findings No findings of significance were identified.

4.

OTHER ACTIVITIES (OA)

4OA1 Performance Indicator Verification (71151)

a.

Inspection Scope The inspectors verified the licensees assessment of its performance indicators for the previous four calendar quarters for the occupational and public radiation safety cornerstones as well as the reactor coolant system (RCS) specific activity. No reportable elements were identified by the licensee for the 4th quarter of 2000 and the 1st, 2nd, and 3rd quarters of 2001. The inspector reviewed the 4th quarter 2000 and 1st, 2nd, and 3rd quarter condition reports, public dose records, and RCS specific activity records to verify that there were no occurrences during those quarters concerning the occupational and public radiation safety cornerstones and the RCS specific activity.

b.

Findings No findings of significance were identified.

4OA3 Event Follow-up (71153)

a.

Inspection Scope The inspectors reviewed and verified the accuracy of Event Notification 38535 that licensee personnel reported to the NRC on December 4, 2001, regarding the failure of the emergency response data system during quarterly testing.

b.

Findings No findings of significance were identified.

4OA6 Meeting Exit Meetings The inspectors presented the inspection results to M and other members of licensee management on January 3, 2002, after the inspection period ended. Licensee personnel acknowledged the findings presented. No proprietary information was identified at the exit meeting. The following interim exit meetings were also conducted during the inspection period:

Interim Exit Meeting Senior Official at Exit:

D. J. Malone, Plant General Manager Date:

November 29, 2001 Proprietary:

No Subject:

Radiation Monitoring Instrumentation Interim Exit Meeting Senior Official at Exit:

J. Fletcher, Security Manager Date:

December 3, 2001 Proprietary:

No Subject:

Safeguards Contingency Plan Review Interim Exit Meeting Senior Official at Exit:

D. Cooper, Site Vice President Date:

December 14, 2001 Proprietary:

No Subject:

Biennial Heat Sink

KEY POINTS OF CONTACT Licensee B. Benson, Unit Supervisor T. Brown, Manager, Chemical and Radiological Services M. Carlson, Programs Engineering Manager D. Cooper, Site Vice President D. Crabtree, Systems Engineering Manager B. Dotson, Licensing Analyst J. J. Fletcher, Security Manager P. Harden, Director, Engineering J. Hager, Heat Exchanger Coordinator L. Lahti, Licensing Manager D. G. Malone, Supervisor, Regulatory Assurance D. J. Malone, General Plant Manager G. Packard, Operations Superintendent K. Smith, Operations Manager N. Stacks, Service Water System Engineer E. Tiffany, Maintenance Rule Engineer R. Westerhof, Reliability Section Leader J. Wong, Design Engineer NRC D. Hood, Project Manager, NRR

LIST OF ITEMS OPENED, CLOSED, AND DISCUSSED Opened 50-255/01-16-01 NCV Failure to promptly identify and correct deficiencies associated with the cold weather protection of Level Instrumentation on the Condensate Storage Tank.

50-255/01-16-02 NCV Failure to follow a preventative maintenance procedure step to inspect the head sprockets and sprocket tooth-inserts on the traveling screens for wear.

50-255/01-16-03 NCV Failure to promptly identify and correct deficiencies observed on the F-4B traveling screen boot-plate.

Closed 50-255/01-16-01 NCV Failure to promptly identify and correct deficiencies associated with the cold weather protection of Level Instrumentation on the Condensate Storage Tank.

50-255/01-16-02 NCV Failure to follow a preventative maintenance procedure step to inspect the head sprockets and sprocket tooth-inserts on the traveling screens for wear.

50-255/01-16-03 NCV Failure to promptly identify and correct deficiencies observed on the F-4B traveling screen boot-plate.

LIST OF ACRONYMS USED ARM Area Radiation Monitor CAM Continuous Air Monitor CFR Code of Federal Regulations CR Condition Report CRD Control Rod Drive FSAR Final Safety Analysis Report NCV Non-Cited Violation PPAC Predetermined and Periodic Activity Control PPC Plant Process Computer RCS Reactor Coolant System SCBA Self-Control Breathing Apparatus

LIST OF DOCUMENTS REVIEWED 1R01 Adverse Weather Protection SOP-23 System Operating Procedure -23, Plant Heating System Revision 15 Checklist CL-CWCL-1 Cold Weather Checklist Revision 15 Checklist CL-CWCL-2 Cold Weather Checklist - Electrical Revision 15 SOP-23, CWCL-2 Completed System Operating Procedure 23 -

Plant Heating Systems - Checklist CL-CWCL-2, Cold Weather Checklist - Electrical, dated 11/6/01 Revision 15 SOP-23, CWCL-1 Completed System Operating Procedure 23 -

Plant Heating Systems - Checklist CL-CWCL-1, Cold Weather Checklist Revision 15 WR 277431 Flexible Conduit for heat trace cables is unsupported and does not meet standards -

equipment deficiencies noted during NRC walkdown of Safety Injection Refueling Water Tank WR 277467 Insulation on Condensate Storage Tank Level Instrument Sensing Lines is Degraded - Repair or Replace Condition Reports Reviewed To Assess Problem Identification Characterization CPAL0103844 NRC Noted Weaknesses in the Cold Weather Checklist (SOP-23 Attachment 8, 9, and 14)

CPAL0103859 Heat Tracing Deteriorated CPAL0103860 Insulated Cover for Domestic Water Tank not Properly Installed CPAL0103903 Potential Inadequacies In Plant Cold Weather Preparation Activities CPAL0103934 Insulation on Condensate Storage Tank Level Sensing Lines Not Installed in a Timely Manner

1R04 Equipment Alignment Plant Procedures GOP-14, Attachment 3 Shutdown Cooling Equipment Availability Revision 14 GOP-14, Attachment 6 Maintenance of Vital Auxiliaries - Electric Plant DC Revision 14 GOP-14, Attachment 9 Primary Coolant System Heat Removal Revision 14 GOP-14, Attachment 11 Maintenance of Vital Auxiliaries - Miscellaneous Revision 14 GOP-14, Attachment 15 Shutdown Operation Protected Train Equipment List Revision 14 GOP-14, Attachment 16 Shutdown Operation Equipment Sheets Revision 14 SOP-15, Attachment 2 Service Water System Checklist - Critical Revision 21 SOP-30, Attachment 6 Station Power System Checklist Revision 31 Condition Reports Reviewed To Assess Corrective Actions CPAL0103067 Bus 1C and 1D Voltages Were at Minimum Allowed Values Prior To Power Control Adjustment CPAL0103282 Space Heaters For EMA-1207, Motor For High Pressure Safety Injection Pump P-66A, Not Energized CPAL0103281 Space Heaters For EMA-1209, Motor For Auxiliary Feedwater Pump P-8C, Not Energized 1R06 Flood Protection Plant Operating Procedures SOP-3, Checklist 3.4 Plant Flood Door System Checklist Revision 46 ONP-12 Acts Of Nature Revision 16 AP-6.02 Control Of Equipment Revision 17

ARP-1 Turbine Condenser and Feedwater Scheme EK-01 (C-1)

Revision 51 ARP-8 Safeguards Safety Injection and Isolation Scheme EK-13 (C-13)

Revision 61 Permanent Maintenance Procedures MSM-M-16 Inspection of Watertight Barriers Revision 9 Predetermined and Periodic Activity Control Procedures RWS-215 Test Operation of Turbine Building Sump Level Switches RWS-218 Preventative Maintenance of Diesel Generator Room Floor Drain Check Valves RWS-217 Clean and Inspect Auxiliary Feedwater Pump Room Floor Drain Check Valve MSM-071 Annual Inspection of Watertight Barriers MSM-091 5-Year Inspection of Watertight Barriers Miscellaneous Documents FSAR, Section 2.2 Hydrology Revision 22 FSAR, Section 5.4 Water Level Design Revision 22 DBD 7.08 Plant Protection Against Flooding Revision 3 Condition Reports Reviewed To Assess Problem Identification Characterization CPAL0102857 Reactor Cavity Flooding System Floor Drains Not Protected From Loose Material CPAL0103710 Possible Common Causal Factors Associated With Control of Flood Doors CPAL0103747 Flood Door #141 (Diesel Generator 1-2 Room )

Not Fully Dogged CPAL0102595 Unexpected Alarm EK-0171 Condensate Pump Room Flooding CPAL0102701 Corrosion Found on Connections For Condensate Pump Room Flooding Level Switch LS-5217

CPAL0101745 Flood Door 142 (Bus 1C Switchgear Room)

Found Undogged Upon Entry CPAL0101343 Tygon Tube Routed Through Flood Door 196A in Violation AP 4.02 Requirements CPAL0101025 Communication Error Results in Turbine Building Sump Flooding CPAL0100506 Flood Door 59 East/West ESGR Not Fully Dogged CPAL0103408 Rain Water in North Storage RCA CPAL0103172 Failure to Adequately Address the Extent of Problem Aspects of CR CPAL0100142 CPAL0104063 Noted a Configuration Control Problem While Preparing To Perform MSM-M-16, Inspection of Watertight Barriers 1R07 Heat Sink Performance Calculations EA-GAK-98-002 Verification for 10 CFR Part 50 Appendix R Shutdown Capability with a Single Component Cooling Water Pump in Operation Revision 2 EA-T300-98-03 Methodology for Analyzing Single Tube Test Data on the CCW Heat Exchangers Revision 1 EA-T300-98-05 Analysis of Pre-Cleaning Single Tube Test Data for Determination of Overall (Total) Fouling Factor for CCW Heat Exchanger E-54A Revision 1 EA-T300-98-06 Analysis of Post-Cleaning Single Tube Test Data for Determination of Overall (Total) Fouling Factor for CCW Heat Exchanger E-54A Revision 0 EA-SST-2001-01 Analysis of Pre-Cleaning Single Tube Test Data for Determination of Overall (Total) Fouling Factor for CCW Heat Exchanger E-54A Revision 0 EA-SST-2001-02 Analysis of Post-Cleaning Single Tube Test Data for Determination of Overall (Total) Fouling Factor for CCW Heat Exchanger E-54A Revision 0 EA-TWK-95-01 Increase CCW Hx Tube Wall Loss Plugging Criteria to 70%

Revision 0

Work Orders 24912514 K-6B, Perform Selected Portions of EPS-M-15 Refer to Step 5 for Steps to Be Performed September 20, 1999 24014799 F-4B, Traveling Screen PM April 20, 2001 24112075 F-4B, Insp/Lube Coupling & Shear Pin November 5, 2001 Miscellaneous Documents Component Cooling Water E-54A EC Inspection Report RF015 April 2001 System Health Assessment - 1st/2nd Quarter 2001, Service Water and Ultimate Heat Sink Condition Reports Reviewed To Assess Problem Identification Characterization CPAL9800595 Traveling Screen F-4B Screen Failure CPAL0002830 Inadequate PPAC Inspection of Traveling Screens F-4B and F-4C CPAL0100545 Intake Bay Ice Results in Traveling Screen F-4C Failure and Entering of ONP 6.1 Loss of Service Water CPAL0100650 Endbell Degradation on Emergency Diesel Generator EDG 1-2 CPAL0103803 F-4B Screen Drive Motor Found Running During Rounds but Screen Was Not Moving CPAL0104101 Damage Found To Traveling Screen F-4C Upper Shaft and Sprocket CPAL0103865 Recommended Inspection/Repair of Traveling Screens in Summer 2001 Not Performed Condition Reports/Action Items Generated as a Result of this Inspection CPAL0103938 Discrepancies Noted in CCW Heat Exchanger E-54A Fouling Factor Analysis CPAL0103970 Failure to Follow an Inspection PPACs Written Instructions APAL0100368 EPRI Heat Exchanger Condition Assessment Calculator

1R11 Licensed Operator Requalification Plant Procedures EOP Supplement

Pre and Post RAS Actions Revision 1A EOP-4.0 Loss Of Coolant Accident Recovery Revision 13 ONP-23.1 Primary Coolant Leak Revision 20 ONP 24.1 Off-Normal Procedure - Loss of Preferred AC Bus Y10 Revision 21 ONP 24.2 Off-Normal Procedure - Loss of Preferred AC Bus Y20 Revision 21 ONP 24.3 Off-Normal Procedure - Loss of Preferred AC Bus Y30 Revision 20 ONP 24.4 Off-Normal Procedure - Loss of Preferred AC Bus Y40 Revision 19 Miscellaneous Documents LOR-SU.SEG Simulator Exercise Guide, Startup Training Revision 0 LOR-SU Classroom/Laboratory Lesson Plan, Startup Training Revision 0 1R12 Maintenance Rule Implementation 125 Volt Vital DC Power Maintenance Rule Scoping Document and associated maintenance rule performance indicators Revision 2 Emergency Diesel Generator Maintenance Rule Scoping Document Revision 2 Emergency Diesel Generator System Health Assessments - 1st/2nd/3rd Quarter 2001 Shutdown Cooling System Maintenance Rule Scoping Document Revision 2 Shutdown Cooling System Health Assessment -

1st/2nd/3rd Quarter 2001 EM - 25 Maintenance Rule Program Revision 3

Condition Reports Reviewed To Assess Corrective Actions CPAL002830 Inadequate PPAC Inspection Of Traveling Screens CPAL980488 Potential For Debris Intrusion Into Service Water Bay CPAL970316 SWS Exceeds Maintenance Rule Performance Criteria CPAL961245 Screen Wash Trash Baskets Filled With Debris CPAL970210 Service Water Pump Bay Level Decrease Without Alarm CPAL0003343 Diesel Generator 1-2 Voltage Meter Responding Erratically (K-6B)

CPAL0100156 Emergency Diesel Generator Fuel Pump Support Wear CPAL0103293 Emergency Diesel Generator 1-2 Fuel Pump Inlet Tube Fastener Elongated CPAL0100840 Control Valve CV-3055 Shutdown Cooling Inlet Failed Acceptance Criteria of IST QO-42 CPAL0101324 Shutdown Cooling Inlet to Shutdown Heat Exchanger Control Valve CV-3055 Failed to Actuate CPAL0101379 Boric Acid Inspection Discovers Condition Which May Affect Valve Set-Point Performance 1R13 Maintenance Risk Assessments and Emergent Work Evaluation Plant Procedures GOP-14, Attachment 3 Shutdown Cooling Equipment Availability, November 26 through December 27, 2001 Revisions 53, 54, 58 60, 61, 63, 64 and

GOP-14, Attachment 16 Shutdown Safety Risk Assessments, November 26 through December 27, 2001 Revisions 53, 54, 58 60, 61, 63, 64 and

GOP-14, Attachment 17 Equipment Waiver Sheets, November 26 through December 28, 2001

Other Documents Shift Supervisor Log entries, November 26 through December 27, 2001 Condition Reports Reviewed To Assess Problem Identification Characterization CPAL0103839 GOP-14 Waive Not In Place When Required 1R16 Operator Workarounds Plant Procedures AP-4.12 Operator Work Around Program Revision 0 SOP-16 Component Cooling Water System Revision 22 EOP Supplement

Jumpering CHP For One Containment Spray Valve Revision 0 ONP-6.2 Loss of Component Cooling Water Revision 8 Miscellaneous Documents Palisades Operator Workarounds Palisades Nuclear Plant Control Room Deficiencies Palisades Operator Challenges 1R17 Permanent Plant Modifications Engineering Assistance Request EAR-2001-0021 Modify packing in CK-ES3166 & CK-3181 with a lower friction design November 21, 2001 Work Request #286687 Modify CK-ES3166 packing gland per EAR 2001-0021. Replace existing packing gland/packing with new packing gland O-ring cartridge assembly.

December 3, 2001 Technical Specification 5.5.2 Primary Coolant Sources Outside Containment Technical Specification Surveillance Procedure No. QO-38 Containment Sump Check Valves Inservice Test Revision 4

Administrative Procedure No. 9.28 Engineering Assistance Request Revision 4 Procurement Evaluation Checklist PEC 94-015-006C O-Rings for CK-ES3166 and CK-ES3181 Revision 8 UFSAR Table 5.8-4 Containment Penetrations and Appendix J Test Requirements UFSAR Chapter 6.0 Engineered Safeguards Systems Condition Reports CPAL0100764 Performance of containment sump check valves during post-DBA recirculation mode may not be acceptable CPAL0103563 Containment sump check valve lab testing results are inconsistent with ECCS model CPAL0103818 As found dimension of body bore is too large for O-ring design Condition Reports Reviewed to Assess Problem Identification Characterization CPAL0103825 NRC identified that recirculation sump check valve modification did not delineate review of environmental factors that could impact o-ring seal package performance CPAL0103832 NRC identified that original post maintenance testing acceptance criteria for recirculation sump check valve modification was non-conservative CPAL0104020 NRC identified that potential exits to allow modified equipment to be returned to service prior to receiving an appropriate 50.59 screening review

1R19 Post Maintenance Testing QO-2 Completed Technical Specification Surveillance and Special Test Procedure - Recirculation Actuation System - December24, 2001 Revision 31 QO-2 Completed Technical Specification Surveillance and Special Test Procedure - Recirculation Actuation System - December25, 2001 Revision 31 QO-2 Basis Document - Technical Specification Surveillance and Special Test Procedure -

Recirculation Actuation System Revision 14 WO 24113483 Check Valve CK-ES3166, Modify Packing Gland per EAR2001-021, Replace Existing Packing Gland/Packing with New Packing Gland/O-Ring Cartridge Assembly RT-71L Technical Specification Admin. 5.5.2 Pressure Test of ESS Pump Suction Piping and associated Basis Document Revisions 9 and 5 QO-38 Completed Technical Specification Surveillance and Special Test Procedure - Containment Sump Check Valves Inservice Test Revision 4 Condition Reports Reviewed To Assess Problem Identification Characterization CPAL0101780 Maintenance Repair Workers Failed to Monitor for Contamination at the Nearest Frisker CPAL0104160 Administrative Procedure 7.15 Requirement Not Followed CPAL0103883 Questionable Basis for Improved Technical Specification Administrative Section 5.5.2E and Pressure Test Requirements CPAL0104153 System Conditions Not Optimal to Support Performance of Scheduled Technical Specification Surveillance Test QO-2

1R23 Temporary Plant Modifications TM-2001-014 Due to damaged detectors, change locations of cabling at the reactor head for the incore detectors to provide the required 16 totally qualified detector installations. Also make corresponding changes to the addresses to provide proper signals to the PPC UFSAR Appendix 7C Regulatory Guide 1.97 Revision 3 Parameter Summary Table Revision 23 Procedure 9.31 Temporary Modification Revision 18 EM-04-01 Manually Reading Incore Detectors Revision 18 EM-04-02 Quadrant Power Tilt Revision 22 RI-80 Incore Neutron Monitoring System Calibration Revision 14 MT-10 Core Monitoring Revision 1 Condition Reports Reviewed To Assess Problem Identification Characterization CPAL0102300 Three Incores Found Broken During Inspection CPAL0102304 Two More ICI Connectors Found Broken During ICI Cable Removal CPAL0102295 ICI Connection at Position 4-1 Discovered Broken CPAL0102288 Reactor Incore Reported Broken CPAL0102260 Incore Neutron Detector #35 Flux and CET Indication Failures 2OS3 Radiation Monitoring Instrumentation Plant Procedures RI-86B-9 Fuel Pool Area Monitor RIA-5709 Calibration Revision 4 RI-86G High Range Containment Monitor Calibration Revision 8 RR-9M Containment Atmosphere Gas Monitor RIA-1817 Calibration Revision 2 HP 7.5 Self-Contained Breathing Apparatus (SCBA)

SURVIVAIR Mark-2 Model 9842 Revision 4

HP 9.13 Eberline Model RO-2/RO-2A and Model RO-20 Portable Ion Chambers Revision 9 HP 9.15 Operation and Calibration of the Eberline Model 6112 Teletector and Xetec Model 330A Telescan Revision 9 HP 9.21 Ludlum Model 177 Ratemeter Revision 5 HP 9.67 Operation and Calibration of the MGP Instruments CDM-21 Calibrator and DMC Electronic Dosimeters Revision 9 RIA-I-9 Area Monitor Functional Check Revision 2 MI-6 Area Monitor Operational Check Revision 7 Miscellaneous Documents Calibration of the Canberra Fastscan WBC System February 2, 2001 Self-Assessment Report, Evaluate Adequacy of the Instrument Program October 25, 2001 Certificate Of Calibration Xetec Model 330A Telescan, sn 42124 November 27, 2001 Certificate Of Calibration Ludlum Model 177 Ratemeter, sn 949 November 27, 2001 Certificate Of Calibration Eberline Model RO-2, sn 11112 November 27, 2001 Database Printouts for SCBA location codes as well as training, medical exams, and fit testings records November 11, 2001 3PP4 Security Plan Changes Palisades Safeguards Contingency Plan Revision 9, August 28, 2001 4OA3 Event Follow-up Event Notification#38535, failure of the emergency response data system during quarterly testing December 4, 2001 Condition Reports Reviewed To Assess Problem Identification Characterization CPAL0103826 Failure of Emergency Response Data System to Connect During Quarterly PPAC Performance