Supplements Re NRC Staff Review of Addl Info Provided in Util for Violation C & Example 5 to Violation A,Identified in Insp Rept 50-244/92-02
ML17262A930
Person / Time
Site: Ginna 
Issue date: 07/21/1992
From: Hehl C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Mecredy R
ROCHESTER GAS & ELECTRIC CORP.
References
NUDOCS 9207300088
Download: ML17262A930 (6)


Text

'

JUL 3i )992 Docket No. 50-244 Dr. Robert Vice President Ginna Nuclear Production Rochester Gas and Electric Corporation 89 East Avenue Rochester, New York 14649

Dear Dr. Mecredy:

SUBJECT:

INSPECTION REPORT NO. 50-244/92-02 This letter supplements our letter of June 15, 1992, regarding the NRC staff review of the additional information provided in the RG&E letter dated May 4, 1992, for Violation C and Example 5 to Violation A, identified in the subject inspection report.

With regards to Violation C, the staff concluded that your response does not adequately address the issue for which the violation was written. Specifically, RG&E did not substantiate that pre-operational test results were reviewed prior to making changes to the service water system (SWS) configuration and operation to determine ifadditional testing of the modified system would be necessary to support its original design capabilities.

Since the Ginna Technical Specifications requires at least two service water pumps to be operable, a single active failure could result in only one service water pump being available during the'accident condition, Additionally, ifthe LOCA occurs without a loss ofoff-site power, the non-safety-related (NSR)

loads would not be isolated.

Therefore, the SWS must be able to remove heat from safety-related components during both the injection and recirculation phases of a LOCA with only one service water pump operating while also supplying NSR loads.

This capability had not been demo'nstrated.

Therefore, this violation stands as written.

The.NRC staff is also evaluating w'hether common mode passive failures such as pipe crack/break scenarios should have been evaluated for the cross-connected configuration.

Regarding the information provided by RG&E for disagreeing that Example 5 to Violation was an appropriate example for the stated violation, the staff does not concur with RG&E's assessment.

Your response does not substantiate that using an inlet service water temperature of75'F in the design analysis for establishing a minimum diesel generator jacket cooler and lube oil cooler service water flow requirements is more conservative than using a service water temperature of 80'F.

Please recognize that much of the information contained in your letter is based on recent analysis by RG&E in response to NRC concerns and is considered corrective action.

Accordingly, it cannot be credited for refuting a violation.

9207300088

'P2072i PDR ADOCK 05000244 ur'x.xCXALRECORD COPY

Dr. Robert ~

~

JUL 2i 1932 Although no further response to this letter is required, it is our expectation that you will take actions to address the concerns reiterated in this letter.

Your corrective actions to, these violations, as well as your overall actions to avoid further violations, willbe reviewed during a future inspection of your licensed program.

Your cooperation with us in this matter is appreciated.

Sincerely, QRGWAL 81CNEO By:

Charles W. Hehl, Director Division of Reactor Projects CC:

R. Smith, Senior Vice President, Production and Engineering Central Records (4 copies)

Director, Power Division State of New York, Department of Law (w/cy of Licensee's Response Letter)

N. Reynolds, Esquire (w/cy of Licensee's Response Letter)

Public Document Room (PDR) (w/cy of Licensee's Response Letter)

Local Public Document Room (LPDR) (w/cy of Licensee's Response Letter)

Nuclear Safety Information Center (NSIC) (w/cy of Licensee's Response Letter)

NRC Resident Inspector (w/cy of Licensee's Response Letter)

State of New York, SLO Designee (w/cy of Licensee's Response Letter)

'

Dr. Robert ~

~

bcc w/cy of Licensee's Response Letter:

W. Lazarus, DRP J. Linville, DRP A. Johnson, PM, NRR T. Moslak, SRI - Ginna JUL 2119K RI:DRP Knutson/meo 7/11/92 RI:D RI:

RI:D v le 7(s 9~

OFFICIALRECORD COPY A:REP9202A.MEO