IR 05000206/1982001
| ML20053D203 | |
| Person / Time | |
|---|---|
| Site: | San Onofre |
| Issue date: | 03/26/1982 |
| From: | Mortensen W, Schuster M NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V) |
| To: | |
| Shared Package | |
| ML20053D193 | List: |
| References | |
| 50-206-82-01, 50-206-82-1, NUDOCS 8206040179 | |
| Download: ML20053D203 (2) | |
Text
v The uiformation on this page is considered to b appropriate for public disclosure pursucnt to 10 CFR 2.790.
.
U.S. fiUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AfiD Et;FORCEMENT
Region V Report No.
50-206/82-01 (IE-V-481)
Docket f!o.
50-206 (SG)
License No.
npp-l a Safeguards Group Licensee:
Southern California Fdinnn Cnmnany 2244 Walnut Greve Avenno Rosemaad. California 91770 Facility Name':
San Onofre Nuclear Generating Station. Unit #1 Inspection at:
Camp Pendleton, California Inspection Conducted:
January 10.12 and Februarv 8-12. 1982 Date of Last Physical Security Inspection Visit:
Sectomber 14-lR.19R1 Type of Inspection:
Routine. Unannounced. Phvnical Protection
~ e
'
' [4--
,.d 1[ 1782.
Inspectors:
Date Signeo W. #P. Mortensen, Physical Protection Inspector Date Signed Date Signed
,
Approved by: Ah b IC
"$ 26 &
uo t_
M. D. Schuster, Chief, Physical Security Section Date Signed Inspection Summary:
Areas Inspected:
Included Security Ort.anization-Management; Security Organizatiu-Personnel; Security Organization-Respcase; Security Program Audits; Records and Reports; Locks, Keys and Combinaticas; Physical Barriers-Protected Areas; Physical Barriers-Vital Areas; Lighting; Assessment Aids; Access Control-Personnel; Alarm Stations and followup items on previous inspection. The inspection involved 61 inspector hours by one NRC inspector; 20 inspection hours were conducted during off shift periods.
Results: The licensee was found to be in compliance with NRC requirements within the twelve areas examined except for the following seven items:
8206040179 820525 INCLOSURE CONTAI2G DRADOCK05000g.
UPON SEPARATION THISd PAGE IS DE00NTROLLED. __
_. _ _
.
-
Inspection Summa,ry-2-
1.
Security Organization - Personnel: Watchmen did not have written security procedures.
2.
Security Organization - Response: Failure to respond to all intrusion alarms.
3.
Records and Reports: Failure to report security incidents as required by 10 CFR 73.71(c).
4.
Records and Reports: Failure to maintain a record of alarms and response at the secondary alara station.
5.
Access Control - Personnel: Failure to provide positive access control at two vital area portals.
6.
Alarm Stations: Failure to require two acknowledgements of each alarm.
7.
Alarm Stations: Secondary Alarm Station audible alarm signal inoperative for excessive duration.
e