Category:Inservice/Preservice Inspection and Test Report
MONTHYEARML22209A0602022-07-28028 July 2022 2022 Inservice Inspection Summary Report GNRO-2021/00014, Inservice Testing Program Relief Request VRR-GGNS-2021-1 Pressure Isolation Valve Testing Frequency2021-06-0101 June 2021 Inservice Testing Program Relief Request VRR-GGNS-2021-1 Pressure Isolation Valve Testing Frequency GNRO-2019/00014, Snubber Testing Program for Fourth Inspection Interval2019-03-13013 March 2019 Snubber Testing Program for Fourth Inspection Interval GNRO-2018/00054, Relief Request No. GG-ISI-023, Inservice Inspection Impracticality: Limited Coverage Examination During the Third 10-Year Inservice Inspection Interval2018-11-30030 November 2018 Relief Request No. GG-ISI-023, Inservice Inspection Impracticality: Limited Coverage Examination During the Third 10-Year Inservice Inspection Interval GNRO-2018/00047, Submittal of 2018 Inservice Inspection Summary Report2018-10-16016 October 2018 Submittal of 2018 Inservice Inspection Summary Report GNRO-2017/00039, Steam Dryer Visual Inspection Results for the First Two Scheduled Refueling Outages2017-06-30030 June 2017 Steam Dryer Visual Inspection Results for the First Two Scheduled Refueling Outages GNRO-2016/00033, Submittal of 2016 Inservice Inspection Summary Report2016-06-20020 June 2016 Submittal of 2016 Inservice Inspection Summary Report GNRO-2014/00043, Inservice Inspection Summary Report2014-06-12012 June 2014 Inservice Inspection Summary Report GNRO-2012/00110, Submittal of Inservice Inspection Summary Report2012-09-11011 September 2012 Submittal of Inservice Inspection Summary Report GNRO-2009/00070, Supplement to Request to Use Portion of Later Edition to the American Society of Mechanical Engineers Code for Operation and Maintenance of Nuclear Power Plants for Main Steam Safety Relief Valve Inservice Testing2009-12-14014 December 2009 Supplement to Request to Use Portion of Later Edition to the American Society of Mechanical Engineers Code for Operation and Maintenance of Nuclear Power Plants for Main Steam Safety Relief Valve Inservice Testing CNRO-2009-00002, Relief Request CEP-ISI-011 for Third 120 Month Inservice Inspection Interval2009-03-0404 March 2009 Relief Request CEP-ISI-011 for Third 120 Month Inservice Inspection Interval GNRO-2009/00004, Inservice Inspection Summary Report2009-01-19019 January 2009 Inservice Inspection Summary Report GNRO-2008/00071, Inservice Inspection (ISI) Program Third 10-Year Interval, Rev. 02008-10-29029 October 2008 Inservice Inspection (ISI) Program Third 10-Year Interval, Rev. 0 GNRO-2008/00057, Transmittal of Inservice Inspection Program Third 10-Year Interval, Revision 02008-07-31031 July 2008 Transmittal of Inservice Inspection Program Third 10-Year Interval, Revision 0 ML0815700022008-06-27027 June 2008 Relief Request GGNS-ISI-004 to Extend 2nd 10-Year Inservice Inspection Interval 4 Months Beyond 1-year Extension Allowed by ASME Code CNRO-2008-00016, Relief Requests for Third 120 Month Inservice Testing Interval2008-05-20020 May 2008 Relief Requests for Third 120 Month Inservice Testing Interval 1CAN030804, Revised Relief Request for 10 Year Update to the 120 Month Inservice Testing Interval, Arkansas Nuclear One, Unit 12008-03-13013 March 2008 Revised Relief Request for 10 Year Update to the 120 Month Inservice Testing Interval, Arkansas Nuclear One, Unit 1 CNRO-2007-00044, Unit 1 and Arkansas Nuclear One, Units 1 & 2 - Inservice Testing Plan2007-11-30030 November 2007 Unit 1 and Arkansas Nuclear One, Units 1 & 2 - Inservice Testing Plan CNRO-2007-00042, Entergy Operations, Inc. - Relief Requests for 10 Year Updates to the 120 Month Inservice Testing Intervals2007-11-29029 November 2007 Entergy Operations, Inc. - Relief Requests for 10 Year Updates to the 120 Month Inservice Testing Intervals GNRO-2007/00046, Inservice Inspection Summary Report2007-07-10010 July 2007 Inservice Inspection Summary Report GNRO-2006/00044, Corrections to Inservice Inspection Summary Report2006-08-10010 August 2006 Corrections to Inservice Inspection Summary Report GNRO-2006/00002, Lnservice Inspection Summary Report for Grand Gulf Nuclear Station Unit 12006-01-13013 January 2006 Lnservice Inspection Summary Report for Grand Gulf Nuclear Station Unit 1 GNRO-2004/00019, Transmittal of Inservice Inspection Summary Reports2004-03-0808 March 2004 Transmittal of Inservice Inspection Summary Reports ML0404901792003-12-18018 December 2003 to CEP-IST-2, Inservice Testing Plan, Entergy Nuclear South Central Engineering Programs GNRO-2003/00022, Boiling Water Reactor (BWR) Feedwater Nozzle Inservice Inspection Report for Grand Gulf Nuclear Station2003-04-0202 April 2003 Boiling Water Reactor (BWR) Feedwater Nozzle Inservice Inspection Report for Grand Gulf Nuclear Station CNRO-2003-00009, Entergy Operations, Referenced Paper for Request to Use ASME Code Case N-6632003-03-14014 March 2003 Entergy Operations, Referenced Paper for Request to Use ASME Code Case N-663 2022-07-28
[Table view] Category:Letter type:GNRO
MONTHYEARGNRO-2023/00014, License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b2023-06-0606 June 2023 License Amendment Request to Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b GNRO-2023/00015, Application to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors2023-06-0606 June 2023 Application to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors GNRO-2021/00037, 2021 Annual Report of Changes and Errors to 10 CFR 50.46 Analysis Grand Gulf Nuclear Station, Unit 12021-11-30030 November 2021 2021 Annual Report of Changes and Errors to 10 CFR 50.46 Analysis Grand Gulf Nuclear Station, Unit 1 GNRO-2021/00017, Notification of Readiness for Supplemental Inspection2021-06-22022 June 2021 Notification of Readiness for Supplemental Inspection GNRO-2021/00014, Inservice Testing Program Relief Request VRR-GGNS-2021-1 Pressure Isolation Valve Testing Frequency2021-06-0101 June 2021 Inservice Testing Program Relief Request VRR-GGNS-2021-1 Pressure Isolation Valve Testing Frequency GNRO-2021/00015, Annual Radioactive Effluent Release Report2021-04-28028 April 2021 Annual Radioactive Effluent Release Report GNRO-2021/00011, Revision of Original Report of 10CFR50.59 and Commitments Change Evaluations - July 1, 2018 Through May 21, 20202021-04-19019 April 2021 Revision of Original Report of 10CFR50.59 and Commitments Change Evaluations - July 1, 2018 Through May 21, 2020 GNRO-2021/00012, Annual Report of Individual Monitoring - NRC Form 5 for 2020 Per 10 CFR 20.22062021-04-13013 April 2021 Annual Report of Individual Monitoring - NRC Form 5 for 2020 Per 10 CFR 20.2206 GNRO-2020/00045, 2020 Report of Changes and Errors to 10 CFR 50.46 Analysis2020-12-16016 December 2020 2020 Report of Changes and Errors to 10 CFR 50.46 Analysis GNRO-2020/00034, Notification of Spent Fuel Cask Use2020-10-0808 October 2020 Notification of Spent Fuel Cask Use GNRO-2020/00033, Response to NRC Integrated Inspection Report 05000416/20200022020-09-10010 September 2020 Response to NRC Integrated Inspection Report 05000416/2020002 GNRO-2020/00029, Report of 10 CFR 72.48 Evaluations July 1, 2018 Through June 30, 20202020-08-18018 August 2020 Report of 10 CFR 72.48 Evaluations July 1, 2018 Through June 30, 2020 GNRO-2020/00022, Report of Technical Specification Bases Changes2020-07-21021 July 2020 Report of Technical Specification Bases Changes GNRO-2020/00027, Core Operating Limits Report (COLR) Cycle 23 Revision 1 for Grand Gulf Nuclear Station, Unit 1 (GGNS)2020-07-16016 July 2020 Core Operating Limits Report (COLR) Cycle 23 Revision 1 for Grand Gulf Nuclear Station, Unit 1 (GGNS) GNRO-2020/00023, Response to Request for Additional Information - License Amendment Request for Permanent Extension of Appendix J Type a Integrated Leakage Rate Test Frequencies2020-06-26026 June 2020 Response to Request for Additional Information - License Amendment Request for Permanent Extension of Appendix J Type a Integrated Leakage Rate Test Frequencies GNRO-2020/00020, Core Operating Limits Report (COLR) Cycle 23, and Pressure and Temperature Limits Report (PTLR) Update for Grand Gulf Nuclear Station, Unit 1 (GGNS)2020-05-0505 May 2020 Core Operating Limits Report (COLR) Cycle 23, and Pressure and Temperature Limits Report (PTLR) Update for Grand Gulf Nuclear Station, Unit 1 (GGNS) GNRO-2020/00018, Annual Radiological Effluent Release Report2020-04-30030 April 2020 Annual Radiological Effluent Release Report GNRO-2020/00016, Annual Report of Individual Monitoring -NRC Form 5 for 2019 Per 10 CFR 20.22062020-04-16016 April 2020 Annual Report of Individual Monitoring -NRC Form 5 for 2019 Per 10 CFR 20.2206 GNRO-2020/00015, Response to Request for Additional Information - License Amendment Request for One-Cycle Extension of Appendix J Type a Integrated Leakage Rate Test and Drywell Bypass Leakage Rate Test2020-04-0707 April 2020 Response to Request for Additional Information - License Amendment Request for One-Cycle Extension of Appendix J Type a Integrated Leakage Rate Test and Drywell Bypass Leakage Rate Test GNRO-2020/00007, Spent Fuel Storage Radioactive Effluent Release Report for 20192020-02-20020 February 2020 Spent Fuel Storage Radioactive Effluent Release Report for 2019 GNRO-2020/00006, License Amendment Request for Permanent Extension of Appendix J Type a Integrated Leakage Rate Test Frequencies2020-02-19019 February 2020 License Amendment Request for Permanent Extension of Appendix J Type a Integrated Leakage Rate Test Frequencies GNRO-2019/00052, Report of Changes and Errors to 10 CFR 50.46 Analysis2019-12-13013 December 2019 Report of Changes and Errors to 10 CFR 50.46 Analysis GNRO-2019/00051, Notification of Readiness of 92723 Inspection2019-12-11011 December 2019 Notification of Readiness of 92723 Inspection GNRO-2019/00045, Emergency Plan, Revision 792019-10-29029 October 2019 Emergency Plan, Revision 79 GNRO-2019/00037, Notification of Spent Fuel Cask Use2019-09-20020 September 2019 Notification of Spent Fuel Cask Use GNRO-2019/00036, Correction to Gnro 2019-00017 Emergency Plan Revision 782019-08-0808 August 2019 Correction to Gnro 2019-00017 Emergency Plan Revision 78 GNRO-2019/00027, Notification of Readiness of 95001 Supplemental Inspections2019-07-0303 July 2019 Notification of Readiness of 95001 Supplemental Inspections GNRO-2019/00031, Annual Report of Individual Monitoring - NRC Form 5 for 2018 Per 10 CFR 20.2206 - Corrected Report2019-06-25025 June 2019 Annual Report of Individual Monitoring - NRC Form 5 for 2018 Per 10 CFR 20.2206 - Corrected Report GNRO-2019/00028, Supplement to Revise Technical Specification (TS) 3.3.1.1, Reactor Protection System (RPS) Instrumentation, and TS 3.3.4.1, End of Cycle Recirculation Pump Trip (EOC-RPT) Instrumentation.2019-06-13013 June 2019 Supplement to Revise Technical Specification (TS) 3.3.1.1, Reactor Protection System (RPS) Instrumentation, and TS 3.3.4.1, End of Cycle Recirculation Pump Trip (EOC-RPT) Instrumentation. GNRO-2019/00026, Response to Requests for Additional Information Regarding Relief Request Number GG-ISI-023, Inservice Inspection Impracticality - Limited Coverage Examinations During the Third 10-Year Inservice Inspection Interval2019-05-0606 May 2019 Response to Requests for Additional Information Regarding Relief Request Number GG-ISI-023, Inservice Inspection Impracticality - Limited Coverage Examinations During the Third 10-Year Inservice Inspection Interval GNRO-2019/00024, Annual Radioactive Effluent Release Report2019-04-30030 April 2019 Annual Radioactive Effluent Release Report GNRO-2019/00020, Annual Radiological Operating Report (AREOR)2019-04-30030 April 2019 Annual Radiological Operating Report (AREOR) GNRO-2019/00022, Annual Report of Individual Monitoring - NRC Form 5 for 2018 Per 10 CFR 20.22062019-04-22022 April 2019 Annual Report of Individual Monitoring - NRC Form 5 for 2018 Per 10 CFR 20.2206 GNRO-2019/00017, Emergency Plan, Revision 782019-03-14014 March 2019 Emergency Plan, Revision 78 GNRO-2019/00014, Snubber Testing Program for Fourth Inspection Interval2019-03-13013 March 2019 Snubber Testing Program for Fourth Inspection Interval GNRO-2019/00012, Internal Events Probabilistic Risk Assessment (PRA) Sensitivity Study Regarding Risk-Informed Justification for the Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program2019-03-0606 March 2019 Internal Events Probabilistic Risk Assessment (PRA) Sensitivity Study Regarding Risk-Informed Justification for the Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program GNRO-2019/00016, Spent Fuel Storage Radioactive Effluent Release Report for 20182019-02-21021 February 2019 Spent Fuel Storage Radioactive Effluent Release Report for 2018 GNRO-2019/00003, Application to Revise Technical Specification (TS) 3.3.1.1, Reactor Protection System (RPS) Instrumentation, and TS 3.3.4.1, End of Cycle Recirculation Pump Trip (EOC-RPT) Instrumentation2019-01-23023 January 2019 Application to Revise Technical Specification (TS) 3.3.1.1, Reactor Protection System (RPS) Instrumentation, and TS 3.3.4.1, End of Cycle Recirculation Pump Trip (EOC-RPT) Instrumentation GNRO-2018/00057, Submittal of Revision 17 to the Grand Gulf Nuclear Station Physical Security, Safeguards Contingency, and Training and Qualification Plan2018-12-0404 December 2018 Submittal of Revision 17 to the Grand Gulf Nuclear Station Physical Security, Safeguards Contingency, and Training and Qualification Plan GNRO-2018/00055, Response to Request for Additional Information for Technical Specification Change Regarding Risk-Informed Justification for the Relocation of Specific Surveillance Frequency Requirements to a ...2018-11-30030 November 2018 Response to Request for Additional Information for Technical Specification Change Regarding Risk-Informed Justification for the Relocation of Specific Surveillance Frequency Requirements to a ... GNRO-2018/00054, Relief Request No. GG-ISI-023, Inservice Inspection Impracticality: Limited Coverage Examination During the Third 10-Year Inservice Inspection Interval2018-11-30030 November 2018 Relief Request No. GG-ISI-023, Inservice Inspection Impracticality: Limited Coverage Examination During the Third 10-Year Inservice Inspection Interval GNRO-2018/00052, License Amendment Request to Incorporate Tornado Missile Risk Evaluator Into Licensing Basis - Partial Response to Request for Additional Information and Extension of Response to Request for Additional Information2018-10-24024 October 2018 License Amendment Request to Incorporate Tornado Missile Risk Evaluator Into Licensing Basis - Partial Response to Request for Additional Information and Extension of Response to Request for Additional Information GNRO-2018/00051, Supplement to Revise Technical Specifications to Adopt Technical Specification Task Force Traveler TSTF-542, Reactor Pressure Vessel Water Inventory Control2018-10-23023 October 2018 Supplement to Revise Technical Specifications to Adopt Technical Specification Task Force Traveler TSTF-542, Reactor Pressure Vessel Water Inventory Control GNRO-2018/00046, Submittal of 2018 Report of Changes and Errors to 10CFR50.462018-10-16016 October 2018 Submittal of 2018 Report of Changes and Errors to 10CFR50.46 GNRO-2018/00047, Submittal of 2018 Inservice Inspection Summary Report2018-10-16016 October 2018 Submittal of 2018 Inservice Inspection Summary Report GNRO-2018/00048, Response to Request for Additional Information License Amendment Request, Adoption of Emergency Action Level Scheme Pursuant to NEI 99-01, Revision 62018-10-10010 October 2018 Response to Request for Additional Information License Amendment Request, Adoption of Emergency Action Level Scheme Pursuant to NEI 99-01, Revision 6 GNRO-2018/00042, Core Operating Limits Report Cycle 22, Revision 12018-09-18018 September 2018 Core Operating Limits Report Cycle 22, Revision 1 GNRO-2018/00043, Revised Offsite Dose Calculation Manual2018-09-18018 September 2018 Revised Offsite Dose Calculation Manual GNRO-2018/00039, Report of Technical Specification Bases Changes2018-08-20020 August 2018 Report of Technical Specification Bases Changes GNRO-2018/00040, Report of 10CFR50.59 Evaluations and Commitment Change Evaluations - July 1, 2016 Through June 30, 20182018-08-20020 August 2018 Report of 10CFR50.59 Evaluations and Commitment Change Evaluations - July 1, 2016 Through June 30, 2018 2023-06-06
[Table view] |
Text
AE* ..
~* .ntergy Entergy Operations, Inc.
P.O. Box756 Port Gibson, Mississippi 39150 Robert J. Franssen General Manager Plant Operations Grand Gulf Nuclear Station Tel: 601-437-2129 10 CFR50.55(a)
. GNR0-2018/00047 October 16, 2018 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001
SUBJECT:
2018 lnservice Inspection Summary Report
- Grand Gulf Nuclear Station, Unit 1 Docket No. 50-416 License No. NPF-29
Dear Sir or Madam:
Entergy Operations Incorporated is submitting the lnservice Inspection Summary Report, OAR-1-00014, as required by Section XI of the American Society of Mechanical Engineers (ASME) Code. The report was prepared and submitted in accordance with the requirements of ASME Code Case N-532-5 as authorized by the Nucl,ear Regulatory Commission (NRC). The attached report contains an overalJ summary of lnservice Inspections perform_ed from March 2016 to July 2018 which encompasses the Third Period of the Third Interval, as well as the First Period of the Fourth Interval. The Third Period of the Third Interval began in June of 2014 and ended in November of 2017. The First Period of the Fourth Interval began in December of 2017 and ends in November of 2020.
This letter contains no new Regulatory Commitments.
Should you have any questions concerning the content of this letter, please contact Douglas A. Neve, Manager Regulatory Assurance, at 601-437-2103.
GNR0-2018/00047 Page 2 of 2 Sincerely, Robert J. Franssen RJFYrws
Attachment:
lnservice Inspection Summary Report Number OAR-1-00014 cc: NRG Senior Resident Inspector Grand Gulf Nuclear Station Port Gibson, MS 39150 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 U.S. Nuclear Regulatory Commission ATTN: Ms. Jennifer Bridges 1600 East Lamar Boulevard Arlington, TX 76011-4511
REPORT NUMBER OAR-1-00014 INSERVICE INSPECTION
SUMMARY
REPORT FOR
(
GRAND GULF NUCLEAR STATION UNIT 1 BALD HILL ROAD PORT GIBSON, MS. 39150 COMMERCIAL OPERATION DATE: JULY 1, 1985 OWNER/OPERATOR ENTERGY OPERATIONS,' INC.
ECHELON ONE P.O. BOX 31995 JACKSON, MS. 39286-1995 PREPARED BY
~!NEER APPROVED BY DOCUMENT COMPLETION 10 -/(&;-If DATE
FORM OAR-1 OWNER'S ACTIVITY REPORT Plant Grand Gulf Nuclear Station, Bald Hill Road, Port Gibson, MS 39150 Unit No._~_ _Commercial Service Date July l, 1985 Refueling Outage No.__g1_
Current Inspection lnterval~~~~~~~~~4~~-*-*~~~~~~~~~~~~~~~~~~~
Current Inspection Period~~~~~~~~~~1-~~**~~~~~~~~~~~~~~~~~~-
Edition and Addenda of Section XI applicable to the inspection plans 2007 Edition I 2008 Addenda **
Date and revision of Inspection plans SEP-ISI-GGN-001, Rev. 7, Effective Date 7/18/2018; SEP-CISl-102 1 Rev. 2, Effective Date 12/1 /2018.
Edition and Addenda of Section XI applicable to the repair/replacement activities, if different'than the inspection plans i1 **Current Interval/Period started on 12/01/17. This OAR-I includes R/R activities performed in the 3rd Interval I 3r Period in accordance with ASME Section XI 200 I Edition I 2003 Addenda.
Code Cases used: N-532-5, N-416-2 N-240 N-241 1516-2, 1567 1 1 1 CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repair/replacement activities and evaluations supporting the completion of RF21 conform to the requirements of Section XI.
- The NIS-2A form for R/R Plan number GG-502335 could not be signed as documented in CR-GGN-2018-11080.
- The NIS-2A form for R/R Plan number GG-441834 could not be signed as documented in CR-GGN-2018-11081.
- The NIS-2A form for AIR Plan number GG-450214 could not be signed as documented in CR-GGN-2018-11082.
- The NIS-2A form for R/R Plan number GG-488532 could not be signed as documented in CR-GGN~201B-11083.
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by HSBCT of Hartford CT , have inspected the items c;iescribed_in this Owners Activity Report and state that, to the best of my knowledge and belief, the Owner has performed all the activities represented by this report in accordance with the requirements of Section XI. .
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluation described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or co ~i with this_inspection.
ANII Signature: l"~ (Inspectors Signature)
Commissions: _,__..L../.....~'-'-7_'.3_2-=-__/_'&;...ic;...:;.~_._---- (National Board and Endorsement)
Date: ffa/!'&?'.'
TABLE 1 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE I
Examination Category and Item Number Item Description Evaluation Description
~- None None None
TABLE 2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Date Repair/Replacement Code Class Item Description Description of Work Completed 'Plan Number AHR Valves 1E12F018B I 2 1E12F046B Replace valves 4-6.-17 GG-449574 01 P41 G01 OR03 3 Pipe Support Replace strut barrel --*-
9-27-18 GG -448241-09 01 P41G011 C02 01 P41 G01 OR03 Q1P41G011C01
- 3 Pipe. Suoports Replace deqraded pins 9-27-18 GG - 448241-02 1B33C001B Decon Flange 1 Bolting Replace nuts and studs 4-17-18 GG-318755 1 P41 F068A SSW Outl FM RHR HX
- 3 . A (Loop A) Replace valve 9-19 I GG-52583096 Cut out and reinstall valve 2 1G36F106 RWCU (weldinq) 9-20-18 GG-440352-01 2 1G36F106 RWCU Beplacetnent of valve 9-20-18 GG-440352-21 IE J 2C002A RHR Replace cap screws and 2 Pump nuts on suction flange 10-4-18 GG-483308 IE12FI03B/ Delete valves I install bar 2 - -
IE12FI04B stock in place of valves 10-4-18 --t,-***-***
GG - 455804 IEI 2FI03A/ Delete valves I install bar 2 !El2Fl04A stock in place of valves -
9-19-18 GG - 479466
\
I B33F023A RECIRC PMP A \ Seal weld body to bonnet 1 Suclion Valvt! per vendor manual 10~3-18 GG - 365147 1E12F036 AHR Replace valve with blind
- 2. Valve fitting 10-3-18 GG - 471203 1 P41 F001 B SSW Pumps 3 Discharqe Valve Replace valve 10-3-18 GG - 479968 1 821 F016 Inboard Main Steam Line Drain Inboard 1 Drain Valve Cut-out and replace valve 9-26-18 GG - 376662 1P41 F012 Check .)
3 Valve Replace check valve 9-20-18 GG - 467875
5
)
1P41F185A HPCS Diesel Water Cooler 3 Inlet Valve Replace valve and bolting 10-4-18 GG - 369242 1T48D001A Standby Gas Weld conduit support Treatment plate to the 1T 48N014A 2 Charcoal Filter exterior. 7-27-17 GG - 465516 1T48D0018 Standby Gas Weld conduit support Treatment plate to the 1T 48N014B 2 Charcoal Filter exterior. 6-29-17 GG - 465517 Replaced u-bolts and nuts on sparger piping 3 SP418001B supports 9-20-18 GG - 266394 Replaced u-bolts and nuts on sparger piping 3 SP4180018 supports 9-20-18 GG-266395 MSRV Serial # Replaced studs and 1 160841 installed helical coils 12-1-16 G G - 403234/1 O MSRV Serial # Replaced studs and 1 160808 installed helical coils 12-1-16 GG - 403234/12 Replaced studs and nuts 2 1G36F101 Valve due to incorrect material 11-30-16 GG - 455785 1B33G265C01 2 -
Snubber Replaced snubber 9-17-18 GG - 472107 1P53F002 Check
.,.._._ 2 Valve Replaced valve 9-19-18 GG - 500229 1821 G490R03 3 Snubber Replaced snubber 9-14-18 GG - 472082 1821 G372R01 3 Snubber Replaced snubber 9-18-18 GG - 471765 1821 G355R01 3 Snubber Replaced Snubber 9-18-18 GG-470702 1833G322RO 1 2 Snubber Replace Snubber 9-17-18 GG - 472460 01821 G369R01 3 Snubber Replace snubber 9-18-18 GG -471626 1821 G024R07 .
3 Snubber Replace snubber 9-14-18 GG - 472742
6 Q 1821 G026C02 1 Snubber Replace snubber 9-14-18 GG - 470642 1B33G337R02 2 Snubber Replace snubber 9-14-18 GG - 472479 1
1821 G423R01 3 - Snubber Replace Snubber 9-14-18 GG-472077 1E12G012R18 1 Snubber ~lace snubber 8-22-18 GG - 473697 01821 G311R01 3 Snubber Replace snubber 9-18-18 'GG-456678 1E12F046C RHR Removed defects 2 Min Flow Valve identified on valve body 9-20-18 GG - 450207-16 1E12F046C AHR Performed weld repair of 2 Min Flow Valve' defect on bodv -
9-20-18 GG - 450207-17 1E12F018C AHR Removed defects 2 Min Flow Valve identified on valve body 9-20-18 GG - 450208-12 Replaced 4" piping and 4"-HBB-115 RHR elbow downstream of I 2 Pipinq 1E12F018C 9-20-18 .. GG - 499493-01 1E12F018C AHR 2 Min Flow Valve Replace valve ' 9-20-18 GG - 499493-11 1E12F046C AHR 2 Min Flow Valve Replace valve 9-20-18 GG - 499493-12 1E12F046C AHR 2 Min Flow Valve Reassemble valve 9-20-18 GG - 499493-22 1E12F018C RHR 2 Min Flow Valve Reassemble valve 9-20-18 GG - 499493-23 4"-HBB-115 RHR 2 Pipinq Replace weld-o-let 9-20-18 GG - 499493-27 Mechanically remove 1E 12F046C AHR excessive root 2 Min Flow Valve penetration in weld 9-20-18 GG - 499493-34
7 Mechanically remove 2 1E12F018C RHR defects identified in the 1 2 Min Flow Valve radioaraph of weld. 9-20-18 GG - 49 9493-35 1P41F001A SSW Pump A 3 Discharge Valve Replace valve 10-4-18 GG - 407083