-=~~.Entergy GNRO-2012/00110 September 11,2012 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555-0001 Entergy Operations, Inc.
P.O. Box 756 Port Gibson, Mississippi 39150 Tel: 601-437-2800 Christina Perino Licensing Manager
Subject:
Inservice Inspection Summary Report Grand Gulf Nuclear Station, Unit 1 Docket No. 50-416 License No. NPF-29
Dear Sir or Madam:
Attached is the Owner's Activity Report, OAR-1-00011, as required by Section XI of the American Society for Mechanical Engineers (ASME) Code (Code). The report was prepared and submitted in accordance with the requirements of ASME Code Case N-532-4 as authorized by the Nuclear Regulatory Commission. The report contains an overall summary of Inservice Inspections performed from May 2010 to June 2012 which encompasses portions of the First and Second Periods of the Third Interval. The First Period of the Third Interval began in June 2008 and ended in May 2011. The Second Period of the Third Interval started June 2011. The report has been certified in accordance with Code requirements.
There are no new commitments contained in this submittal. If you have any questions or require additional information, please contact Ernest Rufus at (601) 437-6582.
Sincerely,ay/6 CLP/RRJ
Attachment:
Report Number OAR-1-00011 cc:
(see next page)
GNRO-2012/00110 Page 2 of 2 CC:
NRC Senior Resident Inspector Grand Gulf Nuclear Station Port Gibson, MS 39150 U.S. Nuclear Regulatory Commission ATTN: Mr. Elmo E. Collins, Jr. (w/2)
Region Administrator, Region IV 1600 East Lamar Boulevard Arlington, TX 76011-4511 U. S. Nuclear Regulatory Commission ATTN: Mr. Alan Wang, NRRlDORL (w/2)
Mail Stop OWFN 8 B1 Washington, DC 20555-0001
Attachment To GNRO*2012/00110 Report Number OAR*1*00011
REPORT NUMBER OAR-1-00011 INSERVICE INSPECTION
SUMMARY
REPORT FOR GRAND GULF NUCLEAR STATION UNIT 1 BALD HILL ROAD PORT GIBSON, MS. 39150 COMMERCIAL OPERATION DATE: JULY 1, 1985 OWNER/OPERATOR ENTERGY OPERATIONS, INC.
ECHELON ONE P.O. BOX 31995 JACKSON, MS. 39286-1995 PREPARED BY
~-EE-R-- ~BY ANI! INSPECTOR I DATE DOCUMENT COMPLETION
'1/;012-SUPERVISOR£CODE PROGRAMS
FORM OAR-1 OWNER'S ACTIVITY REPORT Report Number_~O~AR.=.::.-~1-...;-0=0=0'-O;1~1 Plant Grand Gulf Nuclear Station, Bald Hill Road, Port Gibson, MS 39150 Unit No._~1 Commercial Service Date_--,J,-"u~ly~1.1-'"",19~8=5,,---_,Refueling Outage No.~
Curre~lnspe~oni~erv~~~~~~~~3~r~d~~~~~~~~~~~~~~~~~~~~_
Current Inspection period _~~~~~~..:2~n~d~~~~~~~~~~~~~~
Edition and Addenda of Section XI applicable to the inspection plans 2001 Edition with 2003 Addenda Date and revision of Inspection plans,_~J~a~n~ua~ry..L-:.1~6",,",2=..:O.....1:.=2::...:R...:.:e~v~.~O'-_~~_~~_~ __~
Edition and Addenda of Section XI applicable to the repair/replacement activities, if different than the inspection plans NONE Code Cases used:
N-532-4, N-513-2, N-504-4, N-638-4 CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in the this report are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repair/replacement activities and evaluations supporting the completion of RF18 conform to the requirements of Section XI.
R/R Coordinator:
Date:
- 9,I/c~1rz CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of Mississippi and employed by HSB of Hartford. CT
, have inspected the items described in this Owners Activity Report and state that, to the best of my knowledge and belief, the Owner has performed all the activities represented in this report in accordance with the requirements of Section XI.
(Inspectors Signature)
Commissions:
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the activities described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
~ /7 ANII Signature: ~a~
~_.:..#.......;:.~--ttf,-,e'-40Z""'~F-(National Board, State, Province, and Endorsements)
Date:
tI-/O-/~
TABLE 1 ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Category and Item Number Item Description Evaluation Description Finite Element Analysis on 1P41 F299A to determine Standby Service Water "A" end-of-life and minimum Not Applicable Discharae Safety Relief Valve allowable thickness Finite Element Analysis on 1P41 F299B to determine Standby Service Water "B" end-of-life and minimum Not Applicable Discharae Safety Relief Valve allowable thickness Continued service was Standby Service Water Fan evaluated in accordance with Not Applicable "B" Gearbox Vent Line Code Case N-S13-2 Continued service was Standby Service Water Fan evaluated in accordance with Not Applicable "C" Gearbox Vent Line Code Case N-S13-2 Axial oriented flaw identified during lSI Exam and Weld Overlay performed in RHR/LPCI Inlet Nozzle-to-accordance with Code Cases R-A R1.16 Safe End Weld N-S04-4 and N-638-4
TABLE 2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Date Repair/Replacement Code Class Item Description Description of Work Completed Plan Number Standby Service Replace 1P41 C002 3
Water Pump Pump with Rebuilt Spare 5/28/12 209927-01 Plant Chilled Water Isolation Replace 1P71 F149 valve 2
Valve wedae 5/20/12 310720-02 Standby Service Water Fan "A" Gearbox Drain Replace 1P41 C003A Fan 3
Line Gearbox Drain Line 2/9/12 246499-12 Removed and reinstalled Radwaste Supply leak-off line for Header Isolation 1G33F406A during stem 2
Valve replacement 8/27/12 69401-01 Main Steam Line Removed and reinstalled Drain Valve Leak-leak-off line for 1B21 F016 1
off Line Weld durina stem replacement 9/5/12 69249-01 Reactor Nozzle Weld Overlay on Reactor 1
N06B Nozzle to Safe-End Weld 5/30/12 292095-01 "B" High Pressure Core Spray Diesel Replacement of Water Cooler Inlet 1P41F185B and 3
Valves 1P41 F186B 9/5/12 79906-01 Perform Weld Buildup on Standby Service External Portion of Piping 3
Water Piping due of external corrosion 9/5/12 236701-01 Replacement of Standby Service 1P41 F299B Discharge 3
Water Pipina PipinQ 2/9/12 205289-01 ESF Switchgear Room Cooler Supply Line Drain Replacement of 3
Valve 1P41F323 2/9/12 129492-02