B16320, Revised Monthly Operating Rept for Jan 1997 for Millstone Nuclear Power Station,Unit 2

From kanterella
Jump to navigation Jump to search
Revised Monthly Operating Rept for Jan 1997 for Millstone Nuclear Power Station,Unit 2
ML20136H342
Person / Time
Site: Millstone Dominion icon.png
Issue date: 01/31/1997
From: Stark S
NORTHEAST NUCLEAR ENERGY CO.
To:
Shared Package
ML20136H298 List:
References
B16320, NUDOCS 9703190119
Download: ML20136H342 (2)


Text

.- .

Docket No. 50-336 B16320

-l l

Attachment 2 i

Millstone Nuclear Power Station, Unit No. 2  !

l Facility Operating License No. DPR-65 January 1997 Unit Shutdown and Power Reductions (Revised)

March 1997 9703190119 970313 PDR ADOCK 05000336 R PDR

UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. 50-336 -

UNIT NAME Millstone Unit 2 DATE 03/05/97 COMPLETED BY S. Stark -

TELEPHONE (860) 447-1791 EXT 4419 REPORT MONTH: January 1997 (Revised) 2 No. Date Type' Duration Reason Method of License System Component Cause & Corrective (Hours) Shutting Event Code' Code

  • Action to Down Reactor' Report # Prevent Recurrence 97-01 03/07/96 S!F 744* B;D 4 N/A N/A N/A Scheduled: Continued mid cycle surveillance testing from previous year.

Forced: Continued from previous year. NRC Category til facility; NRC Confirmatory Order requiring independent corrective action verification; NRC order requiring third party review of Millstone Station employee concerns program; design basis verification for response to NRC pursuant to 10CRF50.54(fl.

'F: Forced 2

Reason Method 'lEEE Standard 805-1984, S: Scheduled A - Equipment Failure (Explain) 1 - Manual " Recommended Practices B - Maintenance or Test 2 - Manual Scram for System Identification in C - Refueling 3 - Automatic Scram Nuclear Power Plants and D - Regulatory Restriction 4 - Continued from Previous Month Related Facilities" E - Operator Training & License Examination 5 - Power Reduction (Duration = 0)

F - Administrative 6 - Other (Explain) *lEEE Standard 803A-1983, G - Operational Error (Explain) " Recommended Practices H - Other (Explain) for Unique identification in Power Plants and Related '

Facilities - Component

  • Revised due to typographical error Function Identifiers"

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _