| Title | Failure to Develop a Preventive Maintenance Schedule to Specify Inspection or Replacement of the O-Ring in the High Pressure Core Spray Lower Motor Bearing Drain Plug |
| Description | The inspectors reviewed a self-revealing noncited violation of Technical Specification 5.4.1 for the licensees failure to determine the appropriate preventive maintenance strategy and task frequency for the o-ring in the high pressure core spray lower motor bearing drain plug. As immediate correction action, the licensee replaced the o-ring. At the conclusion of the inspection, the licensee was in the process of determining the appropriate replacement frequency. The licensee entered this issue into their corrective action system as Condition Report CR-RBS-2010-05766.
This finding was more than minor because, if left uncorrected, it had the potential to lead to a more significant safety concern, in that if the licensee did not develop a preventive maintenance schedule for periodically replacing the subject o-ring, degradation of that o-ring due to aging could allow a leak that would drain oil from the lower motor bearing and thus render the high pressure core spray pump inoperable. As described in Inspection Manual 0609 Appendix A, a Phase 2 analysis using the presolved worksheet determined that this finding had very low (Green) risk significance. This finding has a crosscutting aspect in the operating experience component of the problem identification & resolution area because the licensee did not systematically collect, evaluate, and communicate to affected internal stakeholders in a timely manner relevant internal and external operating experience. |
| Site: | River Bend |
|---|---|
| Report | IR 05000458/2010005 Section 1R19 |
| Date counted | Dec 31, 2010 (2010Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | Self-revealing |
| Inspection Procedure: | IP 71111.19 |
| Inspectors (proximate) | B Correll N Greene P Prescott L Carson D Jones A Barrett T Burns R Hagar G Larkin V Gaddy R Latta |
| CCA | P.5, Operating Experience |
| INPO aspect | CL.1 |
| ' | |