Finding | |
|---|---|
| Title | Two Examples of Completing Maintenance that Affected the Performance of Safety-Related Equipment but Was Not Properly Preplanned |
| Description | The inspectors reviewed a two-example self-revealing green noncited violation of Technical Specification 5.4.1 for two occasions on which the licensee completed maintenance that affected the performance of safety-related equipment (high pressure core spray) but was not properly preplanned and performed in accordance with written procedures, documented instructions, or drawings appropriate to the circumstances As a result, the licensee overtorqued the high pressure core spray lower motor bearing drain plug causing the plug to fracture. This fracture resulted in excessive oil leakage that caused the pump to become inoperable. The violation is in the licensees corrective action program as Condition Report CR-RBS-2011-00224
These performance deficiencies were more than minor and therefore constituted a finding because they affected the equipment performance attribute of the Mitigating Systems Cornerstone, and adversely affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. As described in Inspection Manual 0609 Appendix A, a Phase 2 analysis using the presolved worksheet determined that this finding had very low risk significance. The finding has a crosscutting aspect in the resources component of the human performance area because the apparent cause of the finding was a procedure that was not adequate to assure nuclear safety. |
| Site: | River Bend |
|---|---|
| Report | IR 05000458/2010005 Section 1R19 |
| Date counted | Dec 31, 2010 (2010Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | Self-revealing |
| Inspection Procedure: | IP 71111.19 |
| Inspectors (proximate) | B Correll N Greene P Prescott L Carson D Jones A Barrett T Burns R Hagar G Larkin V Gaddy R Latta |
| CCA | H.7, Documentation |
| INPO aspect | WP.3 |
| ' | |