Title | Potential Clogging of Essential Service Water (SX) Throttle Valves for Pump Room Coolers |
Description | The inspectors identified an NCV of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, having very low safety significance for the licensees failure to include appropriate quantitative or qualitative acceptance criteria for determining that important activities have been satisfactorily accomplished. Specifically, the licensees procedures for flow balancing Essential Service Water (SX) supply to safety-related pump room coolers did not include any precautionary statements to limit the degree to which branch loop throttle valves could be throttled down without introducing concerns about potential clogging from particulate in the service water and resultant flow reduction. The licensee subsequently entered the issue into their corrective action program and performed immediate corrective actions included, engineering evaluation to determine current operability, repositioned all throttle valves to at least 34 turns open and revised the valve throttling procedure to prevent any valve from being throttled to less than 34 turns open in the future. The finding was more than minor because it was associated with the Mitigating Systems cornerstone attribute of procedure quality and affected the cornerstone objective of ensuring the capability of the system to respond to initiating events to prevent undesirable consequences. Specifically, under accident conditions, the position of these throttle valves could have led to a potential degradation of the ability of the room coolers to perform their safety-related function of protecting the emergency core cooling system (ECCS) pumps from elevated environmental temperatures. The finding is of very low safety significance (Green) because the design deficiency did not contribute to the likelihood that mitigating equipment or functions would not be available. The inspectors determined there was no cross-cutting aspect associated with this finding because the deficiency was a legacy procedural issue and, therefore, was not indicative of the plants current performance. |
Site: | Braidwood |
---|---|
Report | IR 05000456/2010007 Section 1R21 |
Date counted | Jun 30, 2010 (2010Q2) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.21 |
Inspectors (proximate) | A Dahbur C Brown C Edwards E Sanchez G Morris J Gilliam L Jones P Lougheed S Edmonds |
INPO aspect | |
' | |
Finding - Braidwood - IR 05000456/2010007 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Braidwood) @ 2010Q2
Self-Identified List (Braidwood)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||