Finding | |
|---|---|
| Title | |
| Description | The inspectors identified a finding of very low safety significance and an associated Severity Level IV Non-Cited Violation for the failure to perform an adequate 10 CFR 50.59 screening of a temporary modification. Specifically, the licensee failed to recognize the impact of a temporary modification on emergency operating procedures, which resulted in the failure to perform a full evaluation of the modification. The licensees corrective actions included reinforcing the current configuration of the 2B reactor vessel level indication system with operators and revising emergency operating procedures. In addition, the licensee plans to complete a full 10 CFR 50.59 evaluation to determine whether the modification required NRC approval prior to implementation. The inspectors concluded that the violation was more than minor because the inspectors could not reasonably conclude that the modification would not require prior NRC approval based on the 10 CFR 50.59 screening. The inspectors answered no to the Mitigating Systems cornerstone questions in Table 4 and, as a result, the issue screened as one of very low safety significance (Green). This finding is associated with the cross-cutting area component of decision-making in the human performance cross-cutting area. Specifically, when evaluating the operations impact of a new temporary modification on the 2B RVLIS probe, the licensee assumed the impact was unchanged from a prior temporary modification on the same equipment, which resulted in necessary procedure changes that were not identified (H.1(b)) |
| Site: | Braidwood |
|---|---|
| Report | IR 05000456/2010002 Section 1R18 |
| Date counted | Mar 31, 2010 (2010Q1) |
| Type: | TEV: Severity level IV |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.18 |
| Inspectors (proximate) | N Shah R Langstaff J Robbins B Dickson M Perry A Garmoe R Skokowski C Scott |
| CCA | H.14, Conservative Bias |
| INPO aspect | DM.2 |
| ' | |
Finding - Braidwood - IR 05000456/2010002 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Braidwood) @ 2010Q1
Self-Identified List (Braidwood)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||